T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Similar documents
H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

T9MPV SmartComfort VS90 Product Specifications

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

TSTAT0101SC Recommended (order separately)

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0201CW Recommended (sold separately)

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MULTI POSITION GAS FURNACE

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Rheem Classic Series Multi-position Gas Furnaces

RG7D 1-Stage Heat Series

Multi-Position Gas Furnaces

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Ruud Achiever Plus Series Multi-position Gas Furnaces

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

MULTI POSITION GAS FURNACE

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Energy Saving. Space Saving.

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Classic Plus Series Multi position Gas Furnaces

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

Downflow/Horizontal Right Induced Draft Gas Furnace

GMS9/GCS9 SERIES 93% AFUE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Multi-Position Gas Furnaces

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Comfort, Quality and Efficiency.

MERIT SERIES Downflow

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Transcription:

T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion kits available. Four position -- upflow/downflow/horizontal installation. Vent pipe can be run horizontally or vertically. Internal condensate drain system. Service Self diagnostics. Entire blower assembly mounted on rails. Comfort Adjustable timed blower Off delay. Thermal lined, one piece steel cabinet for noise reduction. Insulated blower compartment. 24 and 115VAC humidifier terminals. Electronic air cleaner terminal. Dehumidification option. Efficiency 92.1% AFUE efficiency range. Two stage gas valve operation. Two stage integrated control. BPM Variable speed DC motor. Induced draft blower. In--shot burners. Quality RPJ III Stainless steel heat exchanger. Stainless steel secondary heat exchanger. High temperature limit control prevents overheating. Direct ignition with Silicon Nitride ignitor. Flame roll--out sensors standard. External filter rack with permanent filters. Stainless steel solid doors. Parts warranty 7 years. No Hassle 1 year replacement warranty. Representative drawing only, some models may vary in appearance. WARNING This furnace is not designed for use inside mobile homes, trailers, or recreational vehicles. Such use could result in property damage, bodily injury, and/or death. THIS MODEL 92.1 UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Model Number Heat Exchangers * Dimensions HxWxD(In.) Input (MBTUH) Efficiency AFUE Cooling Cap. @.5 In. W.C. T9MPV5F12C Lifetime 4 x 19 1 / 8 x29 5 92.1 1.5-3. TON T9MPV75F12C Lifetime 4 x 19 1 / 8 x29 75 92.1 1.5-3.5 TON T9MPVJ2C Lifetime 4 x 22 3 / 4 x29 92.1 3-5.TON T9MPV125L2C Lifetime 4 x 24 1 / 2 x29 125 92.1 3-5.TON * LIMITED LIFETIME WARRANTY. Price 44 21 216 2 (5/26)

FURNACE SPECIFICATIONS Model Number *9MPV5F12 *9MPV75F12 *9MPVJ2 *9MPV125L2 INPUT HIGH FIRE(BTUH) LOW FIRE (BTUH) HTG. CAP. HIGH FIRE (BTUH) LOW FIRE (BTUH) 5, 35, 46, 32, 75, 52,5 7, 48,, 7, 93, 65, AFUE % (ICS) 92.1 92.1 92.1 92.1 TEMP. RISE RANGE High Fire ( o F) Low Fire ( o F) 35-65 35-65 VENT SIZE^ 2 OD 2-3 OD 2-3 OD 3 OD 125, 87,5 118, 82, VOLTS/HZ/PH 115/6/1 115/6/1 115/6/1 115/6/1 RATING PLATE AMPS. 9.5 11.4 14.6 15.4 MIN./MAX. VOLTAGE 14/127 14/127 14/127 14/127 TRANSFORMER (V.A.) 4 4 4 4 GAS PIPE SIZE (IN.) 1/2 1/2 1/2 1/2 COOLING CAP. (TONS) 3. 3. 5. 5. HIGH ALTITUDE PRESSURE SWITCH 3165 3165 3165 3157 FILTER SIZE (IN.) 16X25X1(1) 16X25X1(1) 16X25X1(2) 16X25X1(2) DIMENSIONS (in.) WIDTH X DEPTH X HEIGHT 19 1 / 8 x29x4 19 1 / 8 x29x4 22 3 / 4 x29x4 24 1 / 2 x29x4 WEIGHT (Lbs.) 15 168 187 23 ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. * Denotes Brand (T, H or C) MODEL NUMBER IDENTIFICATION GUIDE * 9 MP V 75 F 12 C # Brand Identifier Engineering Rev. * = Brand Denotes minor changes Marketing Digit Model Efficiency Denotes major change 8 = Non--Condensing, 8+% Gas Furnace Cooling Airflow 9 = Condensing, 9+% Gas Furnace 8 = 8 12 = Installation Configuration 14 = 14 UP = Upflow DN = Downflow UH = Upflow/Horizontal 16 = 16 HZ = Horizontal DH = Downflow/Horizontal 2 = 2 MP = Multiposition, Up/Down/Horizontal Cabinet Width Major Design Feature B = 15.5 Wide 1 = One (Single) Pipe N = Single Stage F = 19.1 Wide 2=TwoPipe P=PVCVent J = 22.8 Wide D = 1 or 2 Pipe T = Two Stage L = 24.5 Wide L = Low NOx V = Variable Speed Input (Nominal MBTUH)

ACCESSORIES Model Number Description Used With Models NAHA2NG Gas Conversion Kits (2--Stage) -- LP (Propane) to natural gas conversion *9MPV (1172961*) kit. Allows field conversion to natural gas. NAHA2LP (1172959*) Gas Conversion Kits (2--Stage) -- Natural gas to LP (propane) conversion Kit (includes low pressure switch). Allows field conversion to LP (propane) gas. NAHAFF Filter Kits -- External filter frame. 16 x25 Side Return (All Furnaces) Bottom Return (All F 19 1 / 8 Furnaces under NAHAFP External filter frame. 16 x25 (Bulk Pack Kit -- Qty 1) 16 ) *9MPV NAHA2FF Filter Kits -- Bottom return filter frame kit 2 x25 (All J 22 3 / 4 Furnaces) NAHA2FP Bottom return filter frame kit 2 x25 (Bulk Pack Kit -- Qty 1) NAHATK Duct Standoff Filter Kit -- To adapt 2 x25 filter for single side return. Side Return (All single return applications with 16 or greater) Bottom Return (All F 19 1 / 8 Furnaces under 16 ) NAHANK Condensate Neutralizer Kit -- for condensing gas furnaces All *9MPV Furnaces if Required 612833 ^ NAHH2SB Combustible Floor Subbase -- Subbase Furnace ONLY: All 19 1 / 4 wide furnace models *9MPV5/75 NAHH3SB NAHHSB Combustible Floor Subbase -- Subbase Furnace ONLY: All 22 3 / 4 wide furnace models Combustible Floor Subbase -- Subbase Furnace ONLY: All 24 1 / 2 wide furnace models *9MPV *9MPV125 NAHH5SB Subbase -- Furnace w/19 1 / 4 cased coil *9MPV5/75 Counterflow furnace w/19 1 / 4 cased coil NAHH6SB Subbase -- Furnace w/22 3 / 4 cased coil *9MPV Counterflow furnace w/22 3 / 4 cased coil NAHH9SB Subbase Furnace w/24 1 / 2 cased coil *9MPV125 Counterflow furnace w/24 1 / 2 cased coil 3165^ High Altitude Pressure Switch Kit *9MPV5, 75 & 3157^ High Altitude Pressure Switch Kit *9MPV125 NAHACV 3 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct *9MPV/125 1129^ vent applications (9+). NAHA2CV 2 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct vent applications (9+). *9MPV5/75 NAHACA Coil Adapter for Downflow Furnaces All Downflow Models NAHA2WL To replace Warning Labels, Operating Instructions & Wiring Labels on *9MPV Blower Door when needed ^ Must be ordered from Service Parts * Denotes Brand

Heating, Cooling & Continuous Airflow Settings Continuous Blower () @.1 Static Lo Heat Air Temperature Adjustment ( F)** #1 #2 5K 75K K 125K * * 56 576 766 888 1 691 697 955 8 1 819 825 1139 1195 1 1 948 931 1327 1373 *Factory Setting Hi Heat Air Temperature Adjustment ( F)** #3 #4 #5 5K 75K K 125K * * * 1 +6 +3 +4 +5 1 +6 +3 +4 +5 1 1 +14 +6 +9 +12 1 +17 +11 +12 +13 1 1 -- 7 -- 4 -- 2 -- 3 1 1 -- 1 -- 6 -- 6 -- 6 1 1 1 -- 15 -- 4 -- 9 -- 5 *Factory setting **Approximate air temperature change from factory setting @.2 static on high heat ). MAX s Filter Size 14 X25 14 16 X25 16 2 X25 2 24 X25 25 Max based on 6 FPM #3 #4 #5 5K 75K K 125K * * * 1 +4 +2 +1 +8 1 +4 +2 +1 +8 1 1 +1 +5 +5 +14 1 +13 +7 +8 +17 1 1 -- 5 -- 4 -- 3 -- 3 1 1 -- 8 -- 6 -- 7 -- 6 1 1 1 -- 16 -- 9 -- 11 -- 6 *Factory setting **Approximate air temperature change from factory setting @.2 static on high heat ). Cooling () @.5 Static (1) #6 #7 #8 5K 75K K 125K * * * 1212 1392 293 282 1 7 1197 1872 1829 1 5 4 172 1798 1 1 914 2 1541 1728 1 836 924 135 153 1 1 743 827 163 134 1 1 67 677 857 3 1 1 1 593 572 751 893 NOTE: (1) Data based on Bottom Only or One Side return. -- Cubic Feet per Minute airflow. Filter required for each return--air inlet. Airflow performance includes 1 washable (6 FPM max) filter media. *Factory setting Blower Motor Settings 25-24 -76 *EXAMPLE Cooling Airflows Switches 6, 7 & 8: 3.5 Ton 3. Ton 2.5 Ton 2. Ton *See Technical Support Manual for correct airflow rates.

Figure 1 Cooling Airflow Settings *9MPV5F12C COOLING 14 8 6 4 2.2.4.6.8 1 Figure 2 *9MPV75F12C COOLING 16 14 8 6 4 2.2.4.6.8 1

Circulation Air Blower Data - *9MPV Figure 3 Cooling Airflow Settings *9MPVJ2C COOLING 24 2 18 15 9 6 3.2.4.6.8 1 Figure 4 *9MPV125L2C COOLING 24 2 16 8 4.2.4.6.8 1

DIMENSIONS 41/ 2 Cabinet to Combustible Clearances TOP BOT. RH LH BACK FRNT FLUE 1 3 TOP AIR INTAKE VENT E A B 4 3/ 8 D FRONT LEFT SIDE 6 11 / 16 TRAP (DOWNFLOW) GAS 1 1 /4 ELECTRICAL 1 1 /16 VENT AIR INTAKE (ALTERNATE) TRAP UPFLOW/HORIZONTAL 4 13 / 16 1 3 / 8 13 11 / 16 2 1 /4 THERMOSTAT 7 28 3 / 4 17 5 / 16 29 7 /8 131/ 4 1 7 / 8 (KO) 1 11 / 16 24 1 / 16 31 11 /16 19 13 /16 4 5 / 16 2 3 / 8 28 1 / 2 18 1 /2 3/4 TYP. 1 1 /16 215 / 8 4 7 / 8 24 GAS RIGHT SIDE TRAP (DOWNFLOW) ELECTRICAL C BOTTOM 11 3 /16 4 13 / 16 AIR INTAKE (ALTERNATE) VENT 4 23 1/ 8 3 7 / 8 33 11 /16 29 7 /8 7 1 1 /16 TRAP (UPFLOW/HORIZONTAL) THERMOSTAT 2 1 / 4 19 13 / 16 27 3 /16 17 5 / 16 ALL DIMENSIONS IN INCHES 21 5 / 8 13 1 / 4 (KO) /16 Unit Cabinet Bottom Top Capacity A B C D E *9MPV5F12A 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 KO = Knockout 4 7 / 8 24 21 5 / 8 1 7 / 8 25--23--36A *9MPV75F12A 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 *9MPVJ2A 22 3 / 4 21 1 / 4 18 3 / 4 2 5 / 8 11 3 / 8 *9MPV125L2A 24 1 / 2 23 23 2 1 / 4 12 1 / 4 * Denotes Brand