T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion kits available. Four position -- upflow/downflow/horizontal installation. Vent pipe can be run horizontally or vertically. Internal condensate drain system. Service Self diagnostics. Entire blower assembly mounted on rails. Comfort Adjustable timed blower Off delay. Thermal lined, one piece steel cabinet for noise reduction. Insulated blower compartment. 24 and 115VAC humidifier terminals. Electronic air cleaner terminal. Dehumidification option. Efficiency 92.1% AFUE efficiency range. Two stage gas valve operation. Two stage integrated control. BPM Variable speed DC motor. Induced draft blower. In--shot burners. Quality RPJ III Stainless steel heat exchanger. Stainless steel secondary heat exchanger. High temperature limit control prevents overheating. Direct ignition with Silicon Nitride ignitor. Flame roll--out sensors standard. External filter rack with permanent filters. Stainless steel solid doors. Parts warranty 7 years. No Hassle 1 year replacement warranty. Representative drawing only, some models may vary in appearance. WARNING This furnace is not designed for use inside mobile homes, trailers, or recreational vehicles. Such use could result in property damage, bodily injury, and/or death. THIS MODEL 92.1 UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Model Number Heat Exchangers * Dimensions HxWxD(In.) Input (MBTUH) Efficiency AFUE Cooling Cap. @.5 In. W.C. T9MPV5F12C Lifetime 4 x 19 1 / 8 x29 5 92.1 1.5-3. TON T9MPV75F12C Lifetime 4 x 19 1 / 8 x29 75 92.1 1.5-3.5 TON T9MPVJ2C Lifetime 4 x 22 3 / 4 x29 92.1 3-5.TON T9MPV125L2C Lifetime 4 x 24 1 / 2 x29 125 92.1 3-5.TON * LIMITED LIFETIME WARRANTY. Price 44 21 216 2 (5/26)
FURNACE SPECIFICATIONS Model Number *9MPV5F12 *9MPV75F12 *9MPVJ2 *9MPV125L2 INPUT HIGH FIRE(BTUH) LOW FIRE (BTUH) HTG. CAP. HIGH FIRE (BTUH) LOW FIRE (BTUH) 5, 35, 46, 32, 75, 52,5 7, 48,, 7, 93, 65, AFUE % (ICS) 92.1 92.1 92.1 92.1 TEMP. RISE RANGE High Fire ( o F) Low Fire ( o F) 35-65 35-65 VENT SIZE^ 2 OD 2-3 OD 2-3 OD 3 OD 125, 87,5 118, 82, VOLTS/HZ/PH 115/6/1 115/6/1 115/6/1 115/6/1 RATING PLATE AMPS. 9.5 11.4 14.6 15.4 MIN./MAX. VOLTAGE 14/127 14/127 14/127 14/127 TRANSFORMER (V.A.) 4 4 4 4 GAS PIPE SIZE (IN.) 1/2 1/2 1/2 1/2 COOLING CAP. (TONS) 3. 3. 5. 5. HIGH ALTITUDE PRESSURE SWITCH 3165 3165 3165 3157 FILTER SIZE (IN.) 16X25X1(1) 16X25X1(1) 16X25X1(2) 16X25X1(2) DIMENSIONS (in.) WIDTH X DEPTH X HEIGHT 19 1 / 8 x29x4 19 1 / 8 x29x4 22 3 / 4 x29x4 24 1 / 2 x29x4 WEIGHT (Lbs.) 15 168 187 23 ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. * Denotes Brand (T, H or C) MODEL NUMBER IDENTIFICATION GUIDE * 9 MP V 75 F 12 C # Brand Identifier Engineering Rev. * = Brand Denotes minor changes Marketing Digit Model Efficiency Denotes major change 8 = Non--Condensing, 8+% Gas Furnace Cooling Airflow 9 = Condensing, 9+% Gas Furnace 8 = 8 12 = Installation Configuration 14 = 14 UP = Upflow DN = Downflow UH = Upflow/Horizontal 16 = 16 HZ = Horizontal DH = Downflow/Horizontal 2 = 2 MP = Multiposition, Up/Down/Horizontal Cabinet Width Major Design Feature B = 15.5 Wide 1 = One (Single) Pipe N = Single Stage F = 19.1 Wide 2=TwoPipe P=PVCVent J = 22.8 Wide D = 1 or 2 Pipe T = Two Stage L = 24.5 Wide L = Low NOx V = Variable Speed Input (Nominal MBTUH)
ACCESSORIES Model Number Description Used With Models NAHA2NG Gas Conversion Kits (2--Stage) -- LP (Propane) to natural gas conversion *9MPV (1172961*) kit. Allows field conversion to natural gas. NAHA2LP (1172959*) Gas Conversion Kits (2--Stage) -- Natural gas to LP (propane) conversion Kit (includes low pressure switch). Allows field conversion to LP (propane) gas. NAHAFF Filter Kits -- External filter frame. 16 x25 Side Return (All Furnaces) Bottom Return (All F 19 1 / 8 Furnaces under NAHAFP External filter frame. 16 x25 (Bulk Pack Kit -- Qty 1) 16 ) *9MPV NAHA2FF Filter Kits -- Bottom return filter frame kit 2 x25 (All J 22 3 / 4 Furnaces) NAHA2FP Bottom return filter frame kit 2 x25 (Bulk Pack Kit -- Qty 1) NAHATK Duct Standoff Filter Kit -- To adapt 2 x25 filter for single side return. Side Return (All single return applications with 16 or greater) Bottom Return (All F 19 1 / 8 Furnaces under 16 ) NAHANK Condensate Neutralizer Kit -- for condensing gas furnaces All *9MPV Furnaces if Required 612833 ^ NAHH2SB Combustible Floor Subbase -- Subbase Furnace ONLY: All 19 1 / 4 wide furnace models *9MPV5/75 NAHH3SB NAHHSB Combustible Floor Subbase -- Subbase Furnace ONLY: All 22 3 / 4 wide furnace models Combustible Floor Subbase -- Subbase Furnace ONLY: All 24 1 / 2 wide furnace models *9MPV *9MPV125 NAHH5SB Subbase -- Furnace w/19 1 / 4 cased coil *9MPV5/75 Counterflow furnace w/19 1 / 4 cased coil NAHH6SB Subbase -- Furnace w/22 3 / 4 cased coil *9MPV Counterflow furnace w/22 3 / 4 cased coil NAHH9SB Subbase Furnace w/24 1 / 2 cased coil *9MPV125 Counterflow furnace w/24 1 / 2 cased coil 3165^ High Altitude Pressure Switch Kit *9MPV5, 75 & 3157^ High Altitude Pressure Switch Kit *9MPV125 NAHACV 3 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct *9MPV/125 1129^ vent applications (9+). NAHA2CV 2 Concentric Vent Kit -- allows single wall penetration for 2 pipe direct vent applications (9+). *9MPV5/75 NAHACA Coil Adapter for Downflow Furnaces All Downflow Models NAHA2WL To replace Warning Labels, Operating Instructions & Wiring Labels on *9MPV Blower Door when needed ^ Must be ordered from Service Parts * Denotes Brand
Heating, Cooling & Continuous Airflow Settings Continuous Blower () @.1 Static Lo Heat Air Temperature Adjustment ( F)** #1 #2 5K 75K K 125K * * 56 576 766 888 1 691 697 955 8 1 819 825 1139 1195 1 1 948 931 1327 1373 *Factory Setting Hi Heat Air Temperature Adjustment ( F)** #3 #4 #5 5K 75K K 125K * * * 1 +6 +3 +4 +5 1 +6 +3 +4 +5 1 1 +14 +6 +9 +12 1 +17 +11 +12 +13 1 1 -- 7 -- 4 -- 2 -- 3 1 1 -- 1 -- 6 -- 6 -- 6 1 1 1 -- 15 -- 4 -- 9 -- 5 *Factory setting **Approximate air temperature change from factory setting @.2 static on high heat ). MAX s Filter Size 14 X25 14 16 X25 16 2 X25 2 24 X25 25 Max based on 6 FPM #3 #4 #5 5K 75K K 125K * * * 1 +4 +2 +1 +8 1 +4 +2 +1 +8 1 1 +1 +5 +5 +14 1 +13 +7 +8 +17 1 1 -- 5 -- 4 -- 3 -- 3 1 1 -- 8 -- 6 -- 7 -- 6 1 1 1 -- 16 -- 9 -- 11 -- 6 *Factory setting **Approximate air temperature change from factory setting @.2 static on high heat ). Cooling () @.5 Static (1) #6 #7 #8 5K 75K K 125K * * * 1212 1392 293 282 1 7 1197 1872 1829 1 5 4 172 1798 1 1 914 2 1541 1728 1 836 924 135 153 1 1 743 827 163 134 1 1 67 677 857 3 1 1 1 593 572 751 893 NOTE: (1) Data based on Bottom Only or One Side return. -- Cubic Feet per Minute airflow. Filter required for each return--air inlet. Airflow performance includes 1 washable (6 FPM max) filter media. *Factory setting Blower Motor Settings 25-24 -76 *EXAMPLE Cooling Airflows Switches 6, 7 & 8: 3.5 Ton 3. Ton 2.5 Ton 2. Ton *See Technical Support Manual for correct airflow rates.
Figure 1 Cooling Airflow Settings *9MPV5F12C COOLING 14 8 6 4 2.2.4.6.8 1 Figure 2 *9MPV75F12C COOLING 16 14 8 6 4 2.2.4.6.8 1
Circulation Air Blower Data - *9MPV Figure 3 Cooling Airflow Settings *9MPVJ2C COOLING 24 2 18 15 9 6 3.2.4.6.8 1 Figure 4 *9MPV125L2C COOLING 24 2 16 8 4.2.4.6.8 1
DIMENSIONS 41/ 2 Cabinet to Combustible Clearances TOP BOT. RH LH BACK FRNT FLUE 1 3 TOP AIR INTAKE VENT E A B 4 3/ 8 D FRONT LEFT SIDE 6 11 / 16 TRAP (DOWNFLOW) GAS 1 1 /4 ELECTRICAL 1 1 /16 VENT AIR INTAKE (ALTERNATE) TRAP UPFLOW/HORIZONTAL 4 13 / 16 1 3 / 8 13 11 / 16 2 1 /4 THERMOSTAT 7 28 3 / 4 17 5 / 16 29 7 /8 131/ 4 1 7 / 8 (KO) 1 11 / 16 24 1 / 16 31 11 /16 19 13 /16 4 5 / 16 2 3 / 8 28 1 / 2 18 1 /2 3/4 TYP. 1 1 /16 215 / 8 4 7 / 8 24 GAS RIGHT SIDE TRAP (DOWNFLOW) ELECTRICAL C BOTTOM 11 3 /16 4 13 / 16 AIR INTAKE (ALTERNATE) VENT 4 23 1/ 8 3 7 / 8 33 11 /16 29 7 /8 7 1 1 /16 TRAP (UPFLOW/HORIZONTAL) THERMOSTAT 2 1 / 4 19 13 / 16 27 3 /16 17 5 / 16 ALL DIMENSIONS IN INCHES 21 5 / 8 13 1 / 4 (KO) /16 Unit Cabinet Bottom Top Capacity A B C D E *9MPV5F12A 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 KO = Knockout 4 7 / 8 24 21 5 / 8 1 7 / 8 25--23--36A *9MPV75F12A 19 1 / 8 17 5 / 8 14 3 / 4 2 1 / 2 9 1 / 2 *9MPVJ2A 22 3 / 4 21 1 / 4 18 3 / 4 2 5 / 8 11 3 / 8 *9MPV125L2A 24 1 / 2 23 23 2 1 / 4 12 1 / 4 * Denotes Brand