CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Similar documents
OLF-5-TAK Tank connection kit 2.0

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating.

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

EN Z Subject to change due to technical improvements! Operating instructions

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

SCHMIDT LED Measured Value Display MD Instructions for Use

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

FluidAqua Mobil FAM 15/30 ATEX

Installation and operation manual

3-way switching valve

Operating Manual SEVi 160 Series

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Read these instructions before using and keep them available at all times!

Test Unit GTL 100 for Fire Detectors

FluidAqua Mobil FAM Economy Series

FP120-Z1 Power supply kit A (70 W) Technical Manual

Energy management function at adsorption dryer PDAD

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

VISY-X. Technical Documentation. VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch. Edition: Version: 6 Art.

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

FluidAqua Mobil FAM 5

Explosion Protection Enclosure with integrated measuring system

Functional Safety Manual June pointek CLS500/LC500

Installation and assembly instructions. for standard configuration radial blowers

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Original operating instructions Safety switch with guard locking AC901S AC902S

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

User manual UV Flash Dry C1

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Vacuum Controller with Control Unit VC 900

Operating instructions

Air Comfort. Installation instructions (English) A

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Diplomat Inverter/Diplomat Duo Inverter

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

TECHNICAL NOTICE GH/GHO/GAE V

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

READ AND SAVE THESE INSTRUCTIONS

Chore-Tronics Load Cell Indicator

Oracle Communications Performance Intelligence Center

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Operator s manual. Battery charger C 48/ en / 03

235L G. Original-Gebrauchsanleitung V1/1115

Alarm System SECURE AS 302

Supplement to operating and installation manual no for the VR 81 remote control unit

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

User instructions DHP-AT

RTO. User guide 05/

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

FluidAqua Mobil FAM Economy Series

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

APC BC300 Series 40kW 208/450/480V User Guide

Operating instructions

Digital Heat Block User Manual

USERS MANUAL FOR GAS BOILERS

Operating instructions

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Control of the system, MLP RO pump station

MANUAL Overflow sensor NVF-104/34-PF

VR 90 Remote control unit

VS2000V Veterinary Vital Signs Monitor Operation Manual

Operating instructions

READ AND SAVE THESE INSTRUCTIONS

Electronic Temperature Controller 70304,

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operation Manual. HTV10L Hand tool TAB2.8 SWS HTV10L crimping head TAB2.8 - SWS

Operating instructions

Detailed operating instructions

Original instructions Sense7-series Non-contact coded safety switch

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

EHA Hoffmann International GmbH

Compact Ultra Low Temperature Chamber

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

OPERATING MANUAL Enertronic Control System 2

SCAN200E USER S MANUAL

Operating instructions

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.6

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Transcription:

Operating Manual English (translation of original instructions) Documentation no.: 3404207a

Trademarks The trademarks of other companies are exclusively used for the products of those companies. Copyright 2008 by HYDAC Filtertechnik GmbH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the explicit written agreement from HYDAC Filtertechnik. Contraventions are liable to compensation. Exclusion of liability We made every endeavor to ensure the accuracy of the contents of this document. However, errors cannot be ruled out. Consequently, we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors. The content of the manual is checked regularly. Any corrections required will be incorporated in future editions. The content of the manual is checked regularly. We welcome any suggestions for improvements. All details are subject to technical modifications. Technical specifications are subject to change without notice. HYDAC Filtertechnik GmbH Industriegebiet D-66280 Sulzbach / Saar Germany Tel.: ++49 (0) 6897 / 509-01 Fax: ++49 (0) 6897 509 846 HYDAC Filtertechnik GmbH en Page 2

Contents Preface...5 Customer Service...6 Modifications to the Product...6 Warranty...6 Using the documentation...7 1 General Safety Guidelines...8 1.1 Obligations and Liability...8 1.2 Explanation of Symbols and Warnings...9 1.2.1 Basic Symbols...9 1.3 Proper/Designated Use...9 1.4 Improper Use...9 1.5 Informal Safety Precautions...10 1.6 Training and Instruction of Personnel...10 1.7 Electrical Hazards...11 1.8 Modifications to the CoMo-Control...11 2 Checking the scope of delivery...12 3 Function description...13 3.1 CoMo display elements...13 3.2 Function plan...14 3.3 Checking CS 1000 settings...15 4 Warnings/Alarms/Messages...15 4.1 Switching contacts in the controller...15 4.1.1 Collective malfunction (K0.0)...15 4.1.2 Malfunction (K0.2)...15 4.2 Setting ISO code alarm...16 4.2.1 ISO Code alarm - delete/reset...16 4.3 Checking/setting water content alarm...17 4.3.1 Water content alarm - delete/reset...17 4.4 Warning filter clogged...18 4.5 Alarm filter clogged...18 4.6 Messages...18 5 Address overview of the Profibus interfaces...20 6 Operating the CoMo...22 6.1 Text display - TD 200...22 6.1.1 Key assignment - TD200...22 6.2 Text display SIMATIC PANEL...23 6.3 Display screen in operation...24 6.4 SETUP Menu Text display TD200...25 6.5 SETUP Menu - SIMATIC PANEL...26 7 Starting up the CoMo...27 HYDAC Filtertechnik GmbH en Page 3

8 Factory default settings...27 9 Maintenance...27 9.1 Disposing of the CoMo...27 10 Technical data...28 HYDAC Filtertechnik GmbH en Page 4

Preface For you, as the owner of a product manufactured by us, we have produced this manual, comprising the most important instructions for its operation and maintenance. It will acquaint you with the product and assist you in using it as intended in an optimal manner. Keep it in the vicinity of the product so it is always available. Note that the information on the unit's engineering contained in the documentation was that available at the time of publication. There may be deviations in technical details, figures, and dimensions as a result. If you discover errors while reading the documentation or have additional comments or suggestions, contact us at: HYDAC Filtertechnik GmbH Division Service technology / Filter systems Technical Documentation Department Postfach 12 51 66273 Sulzbach/Saar - Germany Fax: ++49 (0) 6897 509 846 Email: filtersysteme@hydac.com We look forward to receiving your input. Putting experience into practice HYDAC Filtertechnik GmbH en Page 5

Customer Service Contact our technical sales department if you have any questions on our product. When contacting us, please always include the model/type designation, serial no. and part-no. of the product: Fax: ++49 (0) 6897 509 846 Email: filtersysteme@hydac.com Modifications to the Product We would like to point out that changes to the product (e.g. purchasing additional options, etc.) may mean that the information in the operating instructions is no longer applicable or adequate. After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician. Please notify us immediately of any modifications made to the product whether by you or a third party. Warranty For the warranty provided by us, please refer to the General Terms of Sale and Delivery of HYDAC Filtertechnik GmbH. They are available at: www.hydac.com Legal information. HYDAC Filtertechnik GmbH en Page 6

Using the documentation Note that the method described for locating specific information does not release you from your responsibility of carefully reading these instructions prior to starting the unit up for the first time and at regular intervals in the future. What do I want to know? I assign the information I require to a subject area. Where can I find the information I m looking for? The documentation has a table of contents at the beginning. There, I select the chapter I'm looking for and the corresponding page number. Product Page number Edition date Documentation no. with index/ file name Document language The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index is incremented every time the manual is revised or changed. HYDAC Filtertechnik GmbH en Page 7

1 General Safety Guidelines These operating instructions contain the most important information for operating the CoMo-Control in a proper, safe manner. 1.1 Obligations and Liability The basic prerequisite for the safe and proper handling and operation of the CoMo- Control is knowledge of the safety instructions and warnings. These operating instructions in general, and the safety precautions in particular, are to be adhered by all those who work with the CoMo-Control. Adherence is to be maintained to pertinent accident prevention regulations applicable at the site where the product is used. The safety guidelines listed here are restricted to use of the CoMo-Control. The CoMo-Control has been designed and constructed in accordance with the current state of the art and recognized safety regulations. Nevertheless, hazards may be posed to the life and limb of the individual using the product or to third parties. Risk of damage may be posed to the product or other equipment and property. The CoMo controller is only to be used as follows: solely for its designated use only when in a safe, perfect condition any faults or malfunctions which might impair safety are to be properly repaired or remedied immediately. Our General Terms and Conditions apply. They are made available to the owner upon concluding purchase of the unit at the latest. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes: improper use of the CoMo-Control or use deviating from its designated use improper assembly, installation, commissioning, operation and maintenance of the CoMo Control operating the CoMo Control when the system equipment or systems are defective modifications to the CoMo-Control made by the user or purchaser improper monitoring of product components subject to wear and tear improperly performed repair work HYDAC Filtertechnik GmbH en Page 8

1.2 Explanation of Symbols and Warnings The following designations and symbols are used in this manual to designate hazards, etc.: 1.2.1 Basic Symbols DANGER WARNING CAUTION NOTE DANGER denotes situations which can lead to death if safety precautions are not observed. WARNING denotes situations which can lead to death if safety precautions are not observed. CAUTION denotes situations which can lead to severe injuries if safety precautions are not observed. TIP denotes situations which can lead to property damage if safety precautions are not observed. 1.3 Proper/Designated Use The CoMo-Control was developed for the continuous monitoring of particulate contamination in hydraulic systems. 1.4 Improper Use Improper use may result in hazard to life and limb. HYDAC Filtertechnik GmbH en Page 9

1.5 Informal Safety Precautions Make sure to always keep the operating instructions in the vicinity of the product. In addition to the manual, the general and local regulations concerning accident prevention and protection of the environment should be available and observed. The electrical components of the CoMo Control are to also be regularly checked (visual check once a month). Any loose connections or damaged cables are to be replaced immediately. 1.6 Training and Instruction of Personnel The CoMo-Control may only be operated by properly trained and instructed personnel. The areas of responsibility of your staff must be established in a clear-cut manner. Staff undergoing training may not use the CoMo-Control unless supervised by an experienced staff member. Individuals Activity Individuals undergoing training Individuals with technical training/ engineering background Electrician Supervisor with the appropriate authority Packing Transportation X X X Commissioning X X X Operation X X X X Troubleshootin g / locating the source of malfunction X X X Remedying mechanical problem X X Troubleshootin g, electrical problem X X Maintenance X X X X Repair work Decommissioni ng / Storage X X X X X HYDAC Filtertechnik GmbH en Page 10

1.7 Electrical Hazards WARNING Electric shock The power plug must be pulled before performing work on live parts 1.8 Modifications to the CoMo-Control Do not make any modifications (design modifications, extensions) to the CoMo- Control without the prior consent of the manufacturer. Immediately replace any unit components which are not in perfect condition. Use only original spare parts (OEM). When using non-oem components it cannot be ensured that they have been designed and manufactured so as to comply with loading and safety requirements. HYDAC Filtertechnik GmbH en Page 11

2 Checking the scope of delivery Upon receiving the CoMo-Control check it for any damage in transit. Only a perfectly functioning CoMo controller may be put into operation. Any damage in transit is to be reported to the forwarding agent or the department in charge immediately; the unit may not be commissioned until this damage is properly remedied. The following items are supplied: Item Qty Description 1 1 CoMo-Control - 1 Operating Manual 1 The sensor is not included in the scope of delivery. HYDAC Filtertechnik GmbH en Page 12

3 Function description The CoMo-Control is used for continuous monitoring of hydraulic and lubrication systems. The sensor connected to the CoMo-Control supplies measured values to the SPS Siemens S7-200/300. In the SPS the measured values are permanently compared with the limit values set by the customer. The following are triggered when the limit values are exceeded: Plain text message in text display Illumination of the alarm lamp and Collective malfunction to a relay contact On the basis of the text messages, inspection and maintenance work can be performed on the hydraulics and lubrication system before increased component wear can result in a system breakdown. The following measured values are monitored: Contamination of the oil with solid substances/water Function of the cooling water valve Filter clogging indicator (filter element replacement required) The Profibus connection can be used for linkage with an external S7 Master controller. 3.1 CoMo display elements [2] [1] Item Designation [1] Alarm lamp/signal lamp [2] Text display (TD200/SIMATIC PANEL) HYDAC Filtertechnik GmbH en Page 13

3.2 Function plan K A 4 20 ma J CS 1000 B AS 1000 2x 4 20 ma I C VD2LZ.1 2x I/O D 24 V DC G H E F Item Description A 4... 20 ma input for CS 1000 as ISO Signal B 4 20 ma input for AS 1000 C Switching input for filter contamination display 70% Warning/100% Alarm D 24 V DC input Voltage supply E Switching contact Cooling water valve F Switching contact Flow monitor G Switching contact Pressure switch (operation) H I J Switching contact (K0.0) Switching contact (K0.2) Switching contact (K0.1) Collective malfunction for master display Pressure switch (No pressure) for alarm lamp K Bus connection Profibus HYDAC Filtertechnik GmbH en Page 14

3.3 Checking CS 1000 settings In order for the CoMo-Control to be able to evaluate the data of the CS 1000, the analog output (ANA.OUT) must be set to ISO (time-coded). 4 Warnings/Alarms/Messages The CoMo-Control distinguishes between warnings/alarms and system malfunctions. Warnings are displayed by the flashing of the signal lamp and as plain text on the text display. Diese Warnings can be deleted by acknowledging with the F1/RESET key. If no change is made, then another warning will ensue after 50 minutes. The triggering of a warning ensues as soon as a filter is 75% or 100% clogged. This means that the clogging indicator is announcing a clogging of 75% during a 5- minute period. (The 75% message must be activated beforehand in the Setup Menu.) Alarms are displayed by the flashing of the signal lamp and as plain text on the text display. The cause of the alarm must be eliminated. The alarm can be deleted afterwards by acknowledging with the F1/RESET key. The triggering of an alarm takes place as soon as one of the set values > the set ISO value for each channel or saturation in % has been reached for at least 5 minutes. Messages are malfunctions during which the CoMo-Control controller receives no signals from the system. The sensors and the system must be inspected in such cases. 4.1 Switching contacts in the controller 4.1.1 Collective malfunction (K0.0) The malfunction switching contact is designed as a potential-free directional contact. The directional contact switches the relay K0.0 (X1: 1,2,3) as soon as a warning, an alarm or a system malfunction occurs. The signal is to be processed by an external system controller. 4.1.2 Malfunction (K0.2) The malfunction swtiching contact is designed as a potential-free directional contact. The relay K0.2 (X1: 5,6,7) is switched after a 1-minute time delay whenever as the pressure falls below the set minimum pressure (B0.5) or exceeds the minimum pressure (B0.6). The signal is to be processed by an external system controller, e.g. for switching off the conveyor pump. HYDAC Filtertechnik GmbH en Page 15

4.2 Setting ISO code alarm For example, an alarm is triggered by: ISO channels 4µ 6µ 16µ ISO limit value TGT 16 14 12 ISO actual value ACT 18 14 11 The ISO actual value "ACT" is updated in accordance with the measuring intervals of the CS. The alarm cannot be reset unless the CS limit value in all channels is greater than the ISO actual value. If the limit value is set to a particular value, then the values of the CS 1000 and the display screen can be time-delayed by 5 minutes and varied by +/- 1 class because of the analogue-digital conversion. In the event of a modification of the limit values - ISO Code on the SIEMENS text display, all 3 channels (4µ/6µ/14 µ) in the menu must be run through. It is not until the AS-MAX is displayed that the SETUP Menu can be exited with the F2 key (Setup). This is the only way to guarantee that all modifications to the ISO values will be applied. In addition, the values will be monitored logically, so that the values for the individual channels 4 µm > 6 µm > 14 µm must correspond. 4.2.1 ISO Code alarm - delete/reset The alarm which was triggered when the limit values were reached can be reset by: Filter change on the fluid filter CS 1000 reports cleaner values Set ISO limit values higer in SETUP Every alarm can be reset or deleted by actuating the F1/RESET key. HYDAC Filtertechnik GmbH en Page 16

4.3 Checking/setting water content alarm The alarm will be triggered if the set limit value is > the actual value for a period of 5 minutes. For example, an alarm is triggered by: Water content % limit value TGT 50 % % actual value ACT 60 % The AquaSensor AS continues to supply actual values to the CoMo-Control controller on a permanent basis. HYDAC also offers corresponding dewatering units for continuous reduction of water content. Please contact us for more information. 4.3.1 Water content alarm - delete/reset The water content alarm can be reset only when actual value > limit value. This means that either: The AS 1000 reports a lesser actual value or The limit values % in the SETUP Menu is to be set higher. Every alarm can be reset or deleted by actuating the F1/RESET key. HYDAC Filtertechnik GmbH en Page 17

4.4 Warning filter clogged The 75% filter warning is issued only if: the clogging indicator has a switching point for 75% the warning is activated in the Setup Menu. View Cause(s) Remedy FILTER 1 100% CLOGGED Filter 1 clogged Prepare for change of filter element Prepare for change of FILTER 2 75% CLOGGED Filter 2 clogged filter element Every alarm can be reset or deleted by actuating the F1/RESET key. 4.5 Alarm filter clogged The 100% alarm filter is issued when the clogging indicator reports the contamination. View Cause(s) Remedy FILTER 1 100% CLOGGED FILTER 2 100% CLOGGED Filter 1 clogged Filter 2 clogged Changing the Filter Element Changing the Filter Element 4.6 Messages View Cause(s) Remedy NO COOLING WATER TEMP CABLE BREAK AS CABLE BREAK CS CABLE BREAK The cooling water valve has switched on and the flow monitor displays no flow cooler clogged, cooling water valve defective, cooling water blocked No analogue signal present No analogue signal present No analogue signal present Check cooler and periphery Check supply voltage at AS 1000 and connection cable Check supply voltage at AS 1000 and connection cable Check supply voltage at CS 1000 and connection cable Check ANAOUT for ISO HYDAC Filtertechnik GmbH en Page 18

View Cause(s) Remedy OPERATING PHASE NOT REACHED FILTER 1 75%/100% FILTER 2 75%/100% Pressure switch after the pump does not switch Clogging indicator at Filter 1 is defective Clogging indicator at Filter 1 is defective Check adjustable pressure switch Check function of motorpump assembly Check clogging indicator, replace if necessary Check clogging indicator, replace if necessary CS NOT READY Imprecise SPS read-in RESET key CS VALUE UNDEFINED CS FLOW HIGH CS FLOW LOW Fault with automatic comparison or error in the sensor cell Flow CS 1000 too high Flow CS 1000 too low Perform reset on the CS. (Disconnect CS from the voltage supply and then reconnect.) Check and throttle if necessary the flow at the outlet of the CS1000 Check flow through the CS1000 and/or increase pressure at the CS inlet PUMP ERROR Pressure too low or pressure too high Check motor-pump assembly for proper functioning and leakage Every message can be reset or deleted by actuating the F1/RESET key. HYDAC Filtertechnik GmbH en Page 19

5 Address overview of the Profibus interfaces The CoMo-Control system is a slave at the Profibus DP (Profile: DP; 1.5 Mbit/s; Address 20) and writes 10 WORD starting with Address AW100. YOU CAN READ THE VALUES AT THE FOLLOWING INPUTS ON YOUR DP- MASTER: EW100 AS value physical 0-100% EW102 Temperature physical 25... 100 EW104 ISO Value 14µ EW106 ISO Value 6µ EW108 ISO Value 4µ EW112 Reserve EW112 E112.0 Pump error E112.1 CS cable break E112.2 AS cable break E112.3 Temporary cable break E112.4 Filter 1 hardware error E112.5 Filter 2 hardware error E112.6 Flow monitor E112.7 Collective error AS E113.0 Collective error CS E113.1 Error ISO 14µ E113.2 Error ISO 6µ E113.3 Error ISO 4µ EW114 E114.0 Warning filter 1 70% E114.1 Error filter 1 100% E114.2 Warning filter 2 70% E114.3 Error filter 2 100% E114.4 Warning CS not ready HYDAC Filtertechnik GmbH en Page 20

E114.5 Warning CS value not defined E114.6 Warning CS Flow High E114.7 Warning CS Flow Low E115.0 CS collective malfunction E115.1 AS warning value reached E115.2 CS warning value reached HYDAC Filtertechnik GmbH en Page 21

6 Operating the CoMo Depending on the version, the CoMo-Control is equipped with the text display TD200 or SIMATIC PANEL. 6.1 Text display - TD 200 Text line 1 Text line 2 F5 F6 F7 F8 F1 F2 F3 F4 6.1.1 Key assignment - TD200 Key Description For resetting Warnings/Alarms and error messages To open the SETUP Menu (See Chapter SETUP Menu) Has no function Has no function Increase values Reduce values Has no function The value currently shown on the display will be applied with the ENTER key is pressed HYDAC Filtertechnik GmbH en Page 22

6.2 Text display SIMATIC PANEL This key function appears only in the SETUP Menu DEL INS Text line 1 Text line 2 RESET SETUP + - F1 F2 F3 F4 TAB HELP ESC +/- ACK In the event of Warning/Alarm or error message, SHIFT the ENTER following appears when the F4 key is pressed Key F1 F2 F3 F4 RESET SETUP + - Description For resetting Warnings/Alarms and error messages To open the SETUP Menu (See Chapter SETUP Menu) Increase values Reduce values Scroll upwards in the display or jump back one level Scroll downward through display Has no function HELP ESC ACK Has no function SHIFT Has no function HYDAC Filtertechnik GmbH en Page 23

6.3 Display screen in operation HYDAC Operation 27% AS 28 C F5 F6 F7 F8 F1 F2 F3 F4 HYDAC Operation 27 % AS 28 C RESET SETUP In the event of error messages, it is possible to jump back to the text display by pressing the TAB key. HYDAC Filtertechnik GmbH en Page 24

6.4 SETUP Menu Text display TD200 The limit values and the language of the text display can be set in the Setup Menu. ISO Code 4 µ 16 Enter limit value for 4µ channel. ISO Code 6 µ 14 ISO Code 14 µ 12 AS-MAX 80 % TEMP-MAX 99 C ENGLISH -> 0 GERMAN -> 1 Enter limit value for 6µ channel. Enter limit value for 14µ channel. Limit value for water content as saturation percentage This value has no influence on the controller Display language: 0= deactivated 1= activated Display language: 0= deactivated 1= activated Increase current value Reduce current value Application of the currently displayed value Application of the modified value takes place only after the ENTER key has been actuated. Ending the SETUP Menu HYDAC Filtertechnik GmbH en Page 25

6.5 SETUP Menu - SIMATIC PANEL The limit values and the language of the text display can be set in the Setup Menu. SETUP F2 ISO Code 4 µ 16 - + F1 Enter limit value for 4µ channel. ISO Code 6 µ 14 - + F1 Enter limit value for 6µ channel. ISO Code 14 µ 12 - + F1 Enter limit value for 14µ channel. AS-MAX 80 % - + F1 Limit value for water content as saturation percentage ENGLISH -> 0 - + F1 Display language: 0= deactivated 1= activated GERMAN -> 1 - + F1 Display language: 0= deactivated 1= activated Increase current value + F3 Reduce current value - F4 Application of the currently displayed value Ending the SETUP Menu F1 SETUP F2 Application of the modified value takes place only after the F1 key has been actuated. (SAVE - Mode) HYDAC Filtertechnik GmbH en Page 26

7 Starting up the CoMo A constant pressure of at least 1 bar for a period of 1 minute must prevail in the hydraulics system during the commissioning and/or installation of the CoMo-Control. Afterwards, the controller switches automatically from "STARTUP" to "OPERATION". Should this not be the case, then the message "OPERATING PHASE NOT ACHIEVED" will appear on the display after 1 minute. 8 Factory default settings Description Value ISO Code 4 µ 16 ISO Code 6 µ 14 ISO Code 14µ 12 AS-MAX 80 ENGLISH 0 ENGLISH 1 9 Maintenance The CoMo-Control is almost entirely maintenance-free. 9.1 Disposing of the CoMo When decommissioning and/or disposing of the CSM, adherence is to be maintained to local guidelines and regulations pertaining to occupational safety and environmental protection. After disassembling the unit and separating the various materials, they can be reused or disposed of properly in accordance with local regulations. HYDAC Filtertechnik GmbH en Page 27

10 Technical data Power supply voltage 24 V DC +/- 15 % Power consumption Ambient temperature Storage temperature Relative humidity 1.5 A 10... 40 C 10... 40 C min. 5% - max. 95%, non-condensing Switchbox material Lacquered corrugated steel (RAL 7035) IP class IP 54 HYDAC Filtertechnik GmbH en Page 28

Notes

Notes HYDAC Filtertechnik GmbH en Page 30

Notes HYDAC Filtertechnik GmbH en Page 31

HYDAC Filtertechnik GmbH Bereich Servicetechnik / Service Technology Division Industriegebiet Postfach 1251 66280 Sulzbach/Saar 66273 Sulzbach/Saar Germany Germany Tel: +49 (0) 6897 509 01 Fax: +49 (0) 6897 509 846 (Technical Department) Fax: +49 (0) 6897 509 577 (Sales Department) Internet: www.hydac.com E-mail: filtersysteme@hydac.com