CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Similar documents
Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE


CAPITAL CONTROLS SERIES 480

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation.

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

PRODUCT LINE. Highest Quality, Best Service

Section K CHLORINATION EQUIPMENT

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

HIGH CAPACITY PRODUCT LINE

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

HIGH CAPACITY PRODUCT LINE

ESSEX ENGINEERING CORPORATION

Model Q45P/R. ph/orp Monitor...

Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Model Q45P/R. ph/orp Monitor...

Electronic Flow Switches

Low Temperature Zirconia Oxygen Analyzer

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Two-Channel Gas Controller

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Ultrasonic Point Level Switches

High Pressure Conductivity Monitor

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Series 5000 Hydrazine Analyzer Model 60002

SIL 2. Ultima X Series Gas Monitors CERTIFIED

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

C1N & C2N SERIES Fluid heating for light industrial applications

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Dräger Polytron 8000 Stationary gas detector (EC)

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

Dissolved Oxygen Analyzers

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Oxygen (O2) Single-Point Gas Detection System

Water Technologies. V600 Disinfection Controller

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

SX65 and SX75. Electronic process controllers

Using the DewTrak II Dew Point/ Humidity Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Inductive Conductivity

Installation and Operating Instructions

Temperature Controllers

Instruction Manual Series 1650/1660 Gas Detector Sensor CAPITAL CONTROLS

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Series Temperature Controller Instruction Sheet

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Ultrasonic Switches. Features & Benefits

Nov 08 PRODUCT SPECIFICATION SHEET

Model D12-IR. Digital Gas Transmitter...

Electrochemical Chlorine Sensor Module Addition or Replacement Series 1610B And 1620B

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Process Alarm Module RTA 421

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Toxic Gas Detection. Model F12. Toxic Gas Detection

TEC210x-2 Series Networked Thermostats

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

HFID Heated Total Hydrocarbon Analyzer Module

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

I/A Series 716C 1/16 DIN Temperature Controller

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Free Chlorine Measuring System

TECHNICAL. Series 18. Pump Packages

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

DRINKING WATER WORKS PERMIT

Dräger Polytron 7000 Fixed gas detector

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Mark 25 Ultrapure Water Conductivity Analyzer

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

ULTIMA X5000. MSAX5000.com

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

clean, dry compressed air

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

PolyGard 2-channel Gas Controller MGC-03

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

V600 DISINFECTION CONTROLLER

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

CLEAN, DRY COMPRESSED AIR

Duct and Rough Service Carbon Monoxide Sensor

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

LC2200 Level Controller Installation and Maintenance Instructions

Transcription:

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS The Capital Controls Series WP70CV3 gas feeders are wall panel mounted and vacuum operated. Easy to install, each Series WP70CV3 wall panel feeder is factory tested and needs no field adjustment prior to start-up. Eleven different flowmeter capacities ranging from 5 to 3000 PPD (100 g/h to 60 kg/h) provide versatility in meeting gas flow requirements. The WP70CV3 wall panel feeder includes the Capital Controls Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve, gas flow indicator and a vacuum gauge mounted on a corrosion-resistent, heavy-duty panel. The WP70CV3 wall panel feeder can be provided with integrally mounted and wired high and low vacuum switches. The control valve receives signals from a water flow transmitter and/or chlorine residual analyzer. Automatic switchover is available to provide for uninterrupted service. A complete wall panel gas feeder system consists of a wall panel, vacuum regulator and an ejector, or chemical induction unit. Safe, reliable all-vacuum operation Front access service Space-saving wall panel design Superior materials of construction Variable capacities up to 3000 PPD (60 kg/h) Sonic operation - no D/P regulator required Microprocessor-based automatic control For more information on Capital Controls gas feeders visit www.denora.com

We Understand Gas Feeders Applications For process water, wastewater treatment and water treatment in the municipal or industrial marketplace Disinfection: potable water, municipal wastewater Dechlorination: textiles, wastewater effluent Slime and algae control: irrigation systems, cooling towers Process water: chemical and pharmaceutical manufacture, food (washdown, canning, bleaching, taste and odor control) Cyanide, chromium removal: metal finishing wastes Zebra mussel control Design Features Modern Design: Superior materials of construction provide durability. Reliable: Over 50 years of experience with all vacuum operation, integral venting system. Safe: Remote vacuum regulator enhances safety of installation. Vacuum regulator has a separate independent vent and integral pressure relief device. Versatile: Cylinder, wall or ton container mounting of vacuum regulator. Automatic Switchover: Each vacuum regulator has a built-in automatic switchover function permitting uninterrupted operation. A switchover lever provides visual indication of which gas source is on line. An optional out of gas switch can be provided to remotely indicate switchover status. Figure 1 Figure 1 - Automatic Gas Feed System 2 De Nora Water Technologies

OPERATION Vacuum Regulator Water flowing through the ejector venturi, creates a vacuum which opens the check valve in the remote ejector. The vacuum is carried through the vacuum line to the vacuum regulator where the differential pressure causes the inlet valve on the vacuum regulator to open, initiating gas flow. A spring opposed diaphragm in the vacuum regulator, regulates the vacuum. The gas passes under vacuum through the panel mounted flowmeter and rate control valve. Sonic operation maintains a constant differential across the rate control valve without the need for a differential pressure regulator. Gas flows through the vacuum line and to the ejector where the gas is thoroughly mixed with the water and applied as a solution. (Figure 1) The system is completely under vacuum from the ejector to the vacuum regulator inlet safety valve. If the water supply to the ejector stops or vacuum is lost for any reason, the spring loaded inlet safety valve immediately closes and isolates the pressure gas supply. If the gas source is depleted, the unit seals to prevent moisture from being drawn back into the gas source. Automatic Control The wall panel is designed for automatic control when variable flow and residual demand conditions are present. The Capital Controls 70CV3000 automatic valve will open and close in proportion to a signal received from the internal microprocessor-based control module. The controller receives electrical input signals from a flow meter and/or residual analyzer, along with a remote set-point signal causing the controller to automatically reposition the control valve to maintain the desired gas feed rate or chlorine residual. The Capital Controls 70CV3000 control valve is field configurable for three chlorination and two dechlorination control modes: Flow: Proportioning valve position to process flow. Residual: Single, integral action, adjusting valve based on the difference between the process and the residual set point. Compound Loop: Simultaneous proportioning valve position to a combination of flow proportioning and residual control. If one signal is lost, the controller automatically controls based on remaining signal. Feed Forward: Valve position control directly proportional to flow signal multiplied by the residual signal. Automatic wall panel units include: automatic control valve with integral controller, flowmeter, vacuum gauge and optional vacuum switches. For uninterrupted gas feeding on a round-the-clock basis, an automatic switchover system is provided. Gas flows under vacuum from the regulator in service until that source is depleted, then the switchover function automatically switches service to the standby source. The standby supply will not be accessed until the in-service supply is exhausted. De Nora Water Technologies 3

We Understand Gas Feeders TECHNICAL DATA Quality Standards: ISO 9001 Certified Appovals: Actuator - CE, CSA Capacities: Standard maximum capacities are: 5, 10, 25, 50, 100, 200, 300, 500, 1000, 2000 and 3000 PPD (100, 200 and 500 g/h; 1, 2, 4, 6, 10, 20, 40 and 60 kg/h) of chlorine gas. Process Connections: 200 PPD Max; 3/8, 1/2 or 5/8 tubing 500 PPD Max; 5/8 tubing 3000 PPD Max; 1 NPT Power: Voltage Requirements: 100-250 Vac; +10%/-15% Frequency: 50-60 Hz Quiescent power consumption: 12 VA maximum Operating power consumption: 38.5 VA maximum Electrical Characteristics: Inputs: Residual analyzer and/or Flow Transmitter: two (2) 4-20 madc or 1-5 Vdc (field selectable) with dampening adjustable from 0-25.5 seconds (field selectable) (isolated) Remote set point (local/remote): one (1) 4-20 madc or 1-5 Vdc (field selectable) (isolated) Vacuum switch alarm contact, one (1) Remote standby switch contact, one(1) Outputs: Relay contacts: three (3) 5A resistive at 120 Vac SPDT field configurable for NO/NC. Contacts field configurable for: fault alarm (malfunction or power failure), auto/manual state, local/remote set point, residual HI, residual LO, set point deviation HI, set point deviation LO, water low flow, valve position HI, valve position LO, valve stall, standy, vacuum HI/LO. Calibrated Gas Flow Transmission: one (1) 4-20 madc, maximum load 1000 ohms Electrical Connections: (6) ¾ NPT Internally Threaded Conduit Entrances Field Terminals: Up to 14 AWG Environmental Limits: Ambient Temperature: 40 F to 125 F (4 C to 52 C) Shipping Temperature: -20 F to 125 F (-29 C to 52 C) Control: Modes of Operation: Auto/Manual: Auto - run by control mode, Manual - use up/down pushbuttons Local/Remote: Local set point adjusted at controller, Remote corresponds to input signal Control Modes: Field selectable for flow proportional, residual, compound loop and feed forward Dosage Control: Output: Input Ratio of 0.2:1 to 2.0:1 Manual Override: Manual Control Knob (multi-turn) provided to position valve plug when dosage control is in off position or if power fails. Display: 2x16 characters, vacuum fluorescent display Displays operational parameters as well as alarm conditions Four pushbuttons for display and parameter setup Data Retention: Parameters and calibration profiling are stored in EEPROM 4 De Nora Water Technologies

Physical Characteristics: Outline Dimension: 200 & 500 PPD (4 & 10 kg/h) w/out vacuum switches; approx. 24 H x 20 W x 8 D (61cm H x 51cm W x 21cm D) 3000 PPD (60 kg/h) w/out vacuum switches; approx. 28 H x 22 W x 8 D (71cm H x 56cm W x 21cm D) 200 & 500 PPD (4 & 10 kg/h) w/vacuum switches; approx. 24 H x 30 W x 8 D (61cm H X 76cm W X 21cm D) 3000 PPD (60 kg/h) w/vacuum switches; 28 H x 28 W x 8 D (71cm H x 71cm W x 21cm D) Weight: 200 & 500 PPD (4 & 10 kg/h) w/out vacuum switches; 26 lbs (12 kg) 3000 PPD (60 kg/h) w/out vacuum switches; 38 lbs (17.3 kg) 200 & 500 PPD (4 & 10 kg/h) w/vacuum switches; 35.5 lbs (16 kg) 3000 PPD (60 kg/h) w/vacuum switches; 46.5 lbs (21 kg) Enclosure Classification: NEMA 4X; IP 66 Materials of Construction: Valve: Main Housing & Cover: Cast aluminum with fusion bonded epoxy powder coat Valve Plug: Silver, Kynar, PVC or Austenitic Stainless Steel (capacity and gas type dependent) Orifice: Fluorosint (Mica filled Teflon) Vacuum Switches: Steel with powder coat Panel: Polyethylene De Nora Water Technologies 5

We Understand Gas Feeders Brief Specification The gas feeder design shall be of the vacuum operated, solution feed type. The polyethylene wall panel shall contain the automatic control valve with integral controller, gas flow indicator and (optional) high and low vacuum switches. The gas feeder shall be constructed of materials suitable for wet or dry gas service. All utility inlets and outlets are located on the base of the panel. The vacuum regulator shall be remotely mounted. The Gas Flow Control Valve shall be stepping motor operated with the motor and electronic components mounted in a NEMA 4X enclosure. The valve shall be integrated with a microprocessor-based controller designed to control chemical feed. The valve shall be field configurable for flow proportioning, residual, compound loop or feed forward control. The compound loop control feature shall have the capability of automatic variable lag time adjustment. All setup, tuning and control adjustment shall be achieved from the pushbutton panel. The display shall be a 2-line, 16 character vacuum fluorescent display. Display shall display operational parameters as well as alarm conditions. The valve shall be powered by 100-250 Vac, 47-66 Hz and shall be auto-ranging. The valve shall be equipped with a manual control knob (multi-turn) available to position the valve plug when dosage control is in off position or if power fails. The optional vacuum switches shall be wired to the automatic control valve and have auxiliary contacts available for remote status indication. The vacuum switches shall monitor the vacuum levels from the vacuum source and the vacuum level between the panel and the vacuum regulator. The gas feed panel shall be able to feed chlorine, sulfur dioxide, ammonia or carbon dioxide gases. The maximum feed rate (as chlorine) shall be 3,000 PPD (60 kg/h). The Intelligent Gas Flow Control Valve shall be De Nora Water Technologies Capital Controls Series WP70CV3. Standard features shall include: built-in multiplier for feed forward control: automatic transfer from compound loop control when either the residual or flow signal is lost; bumpless transfer between manual and automatic control, digital vacuum fluorescent display; alarm indication; user configurable alarm contacts; control switch inputs; and a 4-20 madc flow transmitter output signal. The valve shall incorporate a unique 11 point valve plug characterization feature that matches the valve plug characteristic to the gas flow meter. This shall insure a true gas flow retransmission signal to remote monitoring instruments such as a recorder or SCADA system without the need for limited range auxiliary differential pressure metering devices. The valve shall operate under sonic gas flow conditions. The valve shall be able to accept three (3) either 4-20 madc or 1-5 Vdc inputs. Inputs shall be field selectable, two (2) for flow transmitter and/or residual analyzer and one (1) for remote set point. There shall be two (2) contact inputs, one shall be for vacuum switch alarm and the other for a remote standby switch. 6 De Nora Water Technologies

Warranty and Capability There is a one (1) year limited warranty on Series WP70CV3 equipment. De Nora Water Technologies is ISO 9001 certified to provide quality and precision materials. Disinfection technologies, water quality monitors and instrumentation for water and wastewater are areas of specialization. Over 50 years of industrial and municipal application experience in the water and wastewater industries is incorporated into the equipment design to provide high quality comprehensive solutions for the global market. De Nora Water Technologies 7

De Nora Water Technologies 3000 Advance Lane Colmar, PA 18915 United States T: +1 215 997 4000 F: +1 215 997 4062 E: info.dnwt@denora.com www.denora.com Registered Trademark. 2015. All Rights Reserved. 100.0600.5 SEP2015