Similar documents
Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Ultrasonic Switches. Features & Benefits

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

CAPITAL CONTROLS SERIES 480

Section K CHLORINATION EQUIPMENT

PRODUCT LINE. Highest Quality, Best Service

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Two-Channel Gas Controller

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

HIGH CAPACITY PRODUCT LINE

ESSEX ENGINEERING CORPORATION

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Ultrasonic Point Level Switches

HIGH CAPACITY PRODUCT LINE

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation.

High Pressure Conductivity Monitor

Nov 08 PRODUCT SPECIFICATION SHEET

Dräger Polytron 8000 Stationary gas detector (EC)

Electronic Flow Switches

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System

Low Temperature Zirconia Oxygen Analyzer

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor...

Water Technologies. V600 Disinfection Controller

Temperature Controllers

Mark 25 Ultrapure Water Conductivity Analyzer

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SX65 and SX75. Electronic process controllers

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Free Chlorine Measuring System

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Accuracy by Design Products for the HVAC Professional

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Analog Room Pressure Monitor RPC Series

Process Alarm Module RTA 421

CP CP

Toxic Gas Detection. Model F12. Toxic Gas Detection

V600 DISINFECTION CONTROLLER

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

T7079A,B Solid State Remote Temperature Controllers

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Series Temperature Controller Instruction Sheet

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

DT968C C.T. BATH CONTROLLER

SEC 2000 Millenium Infrared Gas Detector

ALTAIR 5X Multigas Detector Product Specification

I/A Series 716C 1/16 DIN Temperature Controller

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Series 5000 Hydrazine Analyzer Model 60002

Dissolved Oxygen Analyzers

ULTIMA X5000. MSAX5000.com

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Dräger Polytron 8000 Stationary gas detector (EC)

DIGITAL METERS Large Display Temperature Meters Instruction Manual

UDC100 Universal Digital Controller Specifications

Stand Alone DYNAGARD SP Operation Manual

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Pioneer-R16 Gas Monitor Operator s Manual

Installation and Operating Instructions

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Duct and Rough Service Carbon Monoxide Sensor

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Toroidal Conductivity Transmitters Series APT4000 Specifications

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Table of Contents SECTION PAGE

3M Oldham OLCT 100. Description. Fixed Gas Detector

CLARITY II TURBIDIMETER

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

WASTEWATER Online UV%Transmission Analyzer

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

ELECTRONIC HUMIDISTAT: H270

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

T6590 Series FAN-COIL CONTROLLER

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

7EF/7HF/7EC/7ES Temperature Controllers

Inductive Conductivity

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

1 INTRODUCTION SYSTEM DESCRIPTION... 3

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Model D12-IR. Digital Gas Transmitter...

Transcription:

www.severntrentservices.com CAPITAL CONTROLS Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve The Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve is designed to control chemical feed in water or wastewater applications. The valve is wall mounted, responds to multiple process signals from a water fl ow transmitter and/or chlorine residual analyzer and is integrated with a microprocessor-based controller. Automatic control eliminates the need for continuous operator monitoring and manual adjustment of the gas feed rate with changes in fl ow or residual, especially where chemical discharge levels are regulated. And since manual system feed rates are based on peak process conditions, automatic feed will reduce gas consumption. The integrated microprocessor-based controller eliminates the need for a separate controller to regulate your gas feed system. The intelligent valve is fi eld confi gurable for fl ow proportioning, residual, compound loop or feed forward control. Residual control is accomplished by a single-mode integral control loop with adjustable process lag time. All setup, tuning and control adjustment is achieved from the pushbutton panel. Standard features include: built-in multiplier for feed forward control; automatic transfer from compound loop control when either the residual or fl ow signal is lost; bumpless transfer between manual and automatic control; digital vacuum fl uorescent display; alarm indication; user confi gurable alarm contacts; control switch inputs and fl ow transmitter output signal. The 70CV3000 Valve incorporates a unique 11 point valve plug characterization feature that matches the valve plug characteristic to the gas fl ow rotameter. This insures a true gas fl ow retransmission signal to remote monitoring instruments such as a recorder or SCADA system without the need for auxiliary differential pressure devices; which eliminates the problem of dual fl ow indications not reading alike. Microprocessor-based integral controller, preconfigured for easy operation NEMA 4X enclosure Valve operates at sonic conditions, no D/P regulator is required Valve can be mounted upside down for ease of installation Electronically characterized valve plug with up to 11-point calibration for superb accuracy Capacities up to 3000 PPD (60 kg/h) Accepts 3 inputs for maximum control Stepping motor for precise valve plug positioning Four gases: Chlorine, Sulfur Dioxide, Ammonia, Carbon Dioxide 4-20 madc gas flow rate output standard 100.0320.0

The valve may be mounted with either the valve body below or above the operator housing for ease of installation. A simple operator choice at the pushbuttons allows the display to indicate in the upright position in either mounting position. Similar units of different materials may be used for feeding ammonia, carbon dioxide and sulfur dioxide gases. The maximum capacities for these feeders are approximately 50%, 75%, and 100% respectively of the chlorinator capacity. The 70CV3000 valve is used in conjunction with a vacuum regulator, gas fl owmeter and an ejector to provide a complete system. (See Figure 1). Figure 1 www.severntrentservices.com

OPERATION The unit has three major components, the metering valve, the electric operator and the microprocessor-based controller. The control valve consists of a housing, a shaped precision plug and a corrosion resistant plastic seat. The plug is positioned by the valve operator to provide precise control of gas feed rates between 1 and 3000 PPD (20 g/h and 60 kg/h) under sonic flow conditions. The control valve operator consists of solid state circuitry, a stepping motor, and a mechanism to position the control valve plug. The valve operator is designed to respond to a flow and/or residual analyzer input signals, either 4-20 madc or 1-5 Vdc. The stepping motor provides precise control of the valve plug with 3200 positions over the full stroke length. The microprocessor-based controller provides the control to take the input signals and control the valve as the chemical demand changes. The modes of controller operation include auto/manual; local/remote and control modes. Auto/Manual: In auto, it is controlled by the control mode selected (see below). In manual mode the up/down pushbuttons on the front of the controller allow for manually positioning of the valve. A manual control knob (multi-turn) on top of the valve is provided to position the valve plug if power fails. Local/Remote: In local, the set point is adjusted by accessing the SP parameter in the control function of the controller. In remote, it corresponds to a setpoint signal, provided from a remote source. Control Modes: Flow Proportional control is in direct proportion to a flow meter signal Residual control is in response to the user set control level and the process residual analyzer signal Compound Loop control is in response to both a flow meter signal and the residual analyzer signal Feed Forward control is achieved by an algorithm utilizing the flow meter and residual analyzer signals to proportion the gas feed based on their combined magnitudes. The choice of control modes are user configurable.

TECHNICAL DATA Quality Standards: ISO 9001 Certifi ed Capacities: Standard maximum capacities are: 10, 25, 50, 100, 200, 300, 500, 1000, 2000 and 3000 PPD (200 and 500 g/h; 1, 2, 4, 6, 10, 20, 40 and 60 kg/h) of chlorine gas. Process Connections: 5/8 inlet and outlet vacuum tubing connector up to 500 PPD (10 kg/h) 1 NPT Threaded inlet and outlet connections for 1000-3000 PPD (20-60 kg/h) Power: Voltage Requirements: 100-240 Vac; 47-63 Hz (Auto Ranging) Quiescent power consumption: 12 VA maximum Operating power consumption: 38.5 VA maximum Electrical Characteristics: Inputs: Residual analyzer and/or Flow Transmitter: two (2) 4-20 madc or 1-5 Vdc (fi eld selectable) with dampening adjustable from 0-25.5 seconds (fi eld selectable) (isolated) Remote set point (local/remote): one (1) 4-20 madc or 1-5 Vdc (fi eld selectable) (isolated) Vacuum switch alarm contact, one (1) Remote standby switch contact, one(1) Outputs: Relay contacts: three (3) 5A resistive at 240 Vac SPDT fi eld confi gurable for NO/NC. Contacts fi eld confi gurable for: fault alarm (malfunction or power failure), auto/manual state, local/remote set point, residual HI, residual LO, set point deviation HI, set point deviation LO, water low fl ow, valve position HI, valve position LO, valve stall, standy, vacuum HI/LO. Calibrated Gas Flow Transmission: one (1) 4-20 madc, maximum load 1000 ohms Electrical Connections: (6) ¾ inch NPT Internally Threaded Conduit Entrances Field Terminals: Up to 14 AWG Environmental Limits: Ambient Temperature: 40 F to 125 F (4 C to 52 C) Shipping Temperature: -20 F to 125 F (-29 C to 52 C) www.severntrentservices.com

Control: Modes of Operation: Auto/Manual: Auto - run by control mode, Manual - use up/down pushbuttons Local/Remote: Local set point adjusted at controller, Remote corresponds to input signal Control Modes: Field selectable for fl ow proportional, residual, compound loop and feed forward Dosage Control: Output: Input Ratio of 0.2:1 to 2.0:1 Manual Override: Manual Control Knob (multi-turn) provided to position valve plug when dosage control is in off position or if power fails. Display: 2X16 characters, vacuum fl uorescent display Displays operational parameters as well as alarm conditions Four pushbuttons for display and parameter setup Data Retention: Parameters and calibration profi ling are stored in EEPROM Physical Characteristics: Outline Dimension: Approx. 16 inch H x 7-3/4 inch W x 8 inch D (41 cm H x 20 cm W x 21 cm D) Weight: 15 lb. (6.8 kg) Enclosure Classification: NEMA 4X; IP 66 Materials of Construction: Main Housing & Cover: Cast aluminum with fusion bonded epoxy powder coat Valve Plug: Silver, Kynar, PVC or Austenitic Stainless Steel (capacity and gas type dependent) Orifice: Fluorosint (Mica fi lled Tefl on)

Series 70CV3000 Chloromatic TM Valve 70CV3 1 1 A FEATURE A B C D POSITION POSITION FEATURE DESCRIPTION A Power Requirements 1 110-240 VAC; 47-63 Hz B Chloromatic Valve 1 No Options C Design Level A Design Level D Maximum Valve Capacity BA 5 PPD, (100 g/h) - NH 3 and Gas BC 10 PPD, (200 g/h) - Cl 2 BS 10 PPD, (200 g/h) - SO 2 CA 10 PPD, (200 g/h) - NH 3 CB 18.75 PPD, (375 g/h) - CO 2 CC 25 PPD, (500 g/h) - Cl 2 CS 25 PPD, (500 g/h) - SO 2 DA 25 PPD, (500 g/h) - NH 3 DB 37.5 PPD, (750 g/h) - CO 2 DC 50 PPD, (1 kg/h) - Cl 2 DS 50 PPD, (1 kg/h) - SO 2 FA 50 PPD, (1 kg/h) - NH 3 FB 75 PPD, (1.5 kg/h) - CO 2 FC 100 PPD, (2 kg/h) - Cl 2 FS 100 PPD, (2 kg/h) - SO 2 GA 100 PPD, (2 kg/h) - NH 3 GB 150 PPD, (3 kg/h) - CO 2 GC 200 PPD, (4 kg/h) - Cl 2 GS 200 PPD, (4 kg/h) - SO 2 HA 150 PPD, (3 kg/h) - CO 2 HB 225 PPD, (4.5 kg/h) - CO 2 HC 300 PPD, (6 kg/h) - Cl 2 HS 300 PPD, (6 kg/h) - SO 2 JA 250 PPD, (5 kg/h) - NH 3 JB 375 PPD, (7.5 kg/h) - CO 2 JC 500 PPD, (10 kg/h) - Cl 2 JS 500 PPD, (10 kg/h) - SO 2 TA 500 PPD, (10 kg/h) - NH 3 TB 750 PPD, (15 kg/h) - CO 2 TC 1000 PPD, (20 kg/h) - Cl 2 TS 1000 PPD, (20 kg/h) - SO 2 UA 1000 PPD, (20 kg/h) - NH 3 UC 2000 PPD, (40 kg/h) - Cl 2 US 2000 PPD, (40 kg/h) - SO 2 VA 1500 PPD, (30 kg/h) - CO 2 VB 2250 PPD, (45 kg/h) - CO 2 VC 3000 PPD, (60 kg/h) - Cl 2 VS 3000 PPD, (60 kg/h) - SO 2 www.severntrentservices.com

Brief Specification The Gas Flow Control Valve shall be stepping motor operated with the motor and electronic components mounted in a NEMA 4X enclosure. The valve shall be integrated with a microprocessor-based controller designed to control chemical feed. The valve shall be fi eld confi gurable for fl ow proportioning, residual, compound loop or feed forward control. The compound loop control feature shall have the capability of automatic variable lag time adjustment. All setup, tuning and control adjustment shall be achieved from the pushbutton panel. Standard features shall include: built-in multiplier for feed forward control: automatic transfer from compound loop control when either the residual or fl ow signal is lost; bumpless transfer between manual and automatic control, digital vacuum fl uorescent display; alarm indication; user confi gurable alarm contacts; control switch inputs; and a 4-20 madc fl ow transmitter output signal. The valve shall incorporate a unique 11 point valve plug characterization feature that matches the valve plug characteristic to the gas fl ow meter. This shall insure a true gas fl ow retransmission signal to remote monitoring instruments such as a recorder or SCADA system without the need for limited range auxiliary differential pressure metering devices. The valve shall operate under sonic gas fl ow conditions. The valve shall be able to accept three (3) either 4-20 madc or 1-5 Vdc inputs. Inputs shall be fi eld selectable, two (2) for fl ow transmitter and/or residual analyzer and one (1) for remote set point. There shall be two (2) contact inputs one shall be for vacuum switch alarm and the other for a remote standby switch. The display shall be a 2-line, 16 character vacuum fl uorescent display. Display shall display operational parameters as well as alarm conditions. The valve shall be powered by 100-240 Vac, 47-63 Hz and shall be auto-ranging. The valve shall be equipped with a manual control knob (multi-turn) available to position the valve plug when dosage control is in off position or if power fails. The valve shall be able to be mounted with either the valve body below or above the operator housing for ease of installation. The valve shall be able to feed chlorine, sulfur dioxide, ammonia or carbon dioxide gases. The maximum feed rate (as chlorine) shall be 3,000 PPD (60 kg/h). The intelligent gas flow control valve shall be Severn Trent Services Capital Controls Series 70CV3000 Chloromatic Valve.

Warranty and Capability Severn Trent Services warrants its auto valves for eighteen (18) months from date of invoice, or twelve (12) months from date of installation. Severn Trent Services is ISO 9001 certifi ed to provide quality and precision materials. Disinfection technologies, water quality monitors and instrumentation for water and wastewater are areas of specialization. Over 35 years of industrial and municipal application experience in the water and wastewater industries is incorporated into the equipment design to provide high quality comprehensive solutions for the global market. Severn Trent Services 3000 Advance Lane Colmar, PA 18915 United States Tel +1 215 997 4000 Fax +1 215 997 4062 marketing@severntrentservices.com 100.0320.0 NOV/09 www.severntrentservices.com