Experimental Performance Evaluation Of Vapour Compression Refrigeration System using R134a and R152a Refrigerants, A review

Similar documents
Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

CHAPTER 1 INTRODUCTION

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

η second law = Second law efficiency

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

A Comparison Between Refrigerants Used In Air Conditioning

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

CHAPTER 1 INTRODUCTION

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Thermodynamics I. Refrigeration and Heat Pump Cycles

Experimental investigation on the performance of air conditioner using R32 Refrigerant

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Department of MCE, Islamic University of Technology 2. Abstract

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Chapter 10. Refrigeration and Heat Pump Systems

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

DEEPAK PALIWAL, S.P.S.RAJPUT

Study of R161 Refrigerant for Residential Airconditioning

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

International Journal of Advance Engineering and Research Development

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

*Corresponding author;

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

ADVANCES in NATURAL and APPLIED SCIENCES

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Thermodynamics II Chapter 5 Refrigeration

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Oyelami S., Bolaji B. O.

Enhancement of COP in Vapour Compression Refrigeration System

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

HFCs or the Old Refrigerants - what is the best Choice?

Evaluation of HCFC Alternative Refrigerants

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Chapter 11 REFRIGERATION CYCLES

Environment Protection Engineering

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Chapter 2. Alternatives to HCFCs and their Characteristics

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

Transcription:

ISSN 2395-1621 Experimental Performance Evaluation Of Vapour Compression Refrigeration System using R134a and R152a Refrigerants, A review #1 Shivprasad S. Surve, #2 V.W.Bhatkar, #3 M.R.Dange #1 ME. Student, Genba Sopanrao Moze College of Engineering, Balewadi, Pune #2 Professor, Marathwada Mitra Mandal's College of Engineering, Pune #3 Head of Department, Genba Sopanrao Moze College of Engineering, Balewadi, Pune ABSTRACT There is increasing concern in India and other countries that global warming is growing in its effect. The global warming impact of a refrigerant relative to CO2 can be measured by its GWP. R134a was initially assessed as having a GWP of 1300 (IPCC 2001) and later assessed to have a GWP of 1430 (IPCC 2007). This is thought to be disconcertingly high and has prompted a search for alternatives. The European Union (EU) is one body that has taken the course of proceeding down the legislative path in order to try to address possible future consequences of global warming. Under the legislation, the replacement refrigerants must have a GWP of less than 150 (Vainio 2006). Industry has begun searching for alternatives with a lower global warming potential (GWP). So there is urgent need of alternative refrigerants to R134a. R-152a is a more environmentally benign refrigerant compared to R-134a with a GWP of 120. Both refrigerants are hydro-fluorocarbons(hfcs) - (contain no chlorine) and hence, have zero ozone depletion potential. R152a have some flammability issues but have no ozone depletion potential and have a significantly lower GWP. R152a is energy efficient than R134a. Project work will deal with test a Vapor Compression Refrigeration System using the two likely drop-in candidate refrigerants R134a and R152a in representative environments under controlled conditions. Performance Parameters such as COP, Cooling capacity, condenser capacity, energy efficiency etc. will be analyzed. Comparison of various properties for refrigerants R152a and R134a will be done for a Vapor Compression Refrigeration System. ARTICLE INFO Article History Received :18 th November 2015 Received in revised form : 19 th November 2015 Accepted : 21 st November, 2015 Published online : 22 nd November 2015 I. INTRODUCTION A vapor compression refrigeration system is an improved type of air refrigeration system in which a suitable working substance, termed as refrigerant is used. It condensed and evaporates at temperatures and pressures close to the atmospheric conditions. Compression refrigeration cycles take advantage of the fact that highly compressed fluids at a certain temperature tend to get colder when they are allowed to expand. If the pressure change is high enough, then the compressed gas will be hotter than our source of cooling (outside air, for instance) and the expanded gas will be cooler than our desired cold temperature. In this case, fluid is used to cool a low temperature environment and reject the heat to a high temperature environment. In the general vapor compression system four processes are involved. In the first process isentropic compression of the refrigerant in compressor takes place. In the second process constant pressure heat rejection of refrigerant in condenser takes place. In the third process Isenthalpic expansion of refrigerant in expansion device takes place. In the fourth process Constant pressure heat absorption in evaporator takes place. Fig-1 Schematic of the Vapor Compression Refrigeration System[1] 2015, IERJ All Rights Reserved Page 1

Figure-2 Pressure-enthalpy graph for vapor compression refrigeration system[10] Process 1 2: Isentropic compression in compressor. The vapor refrigerant at low pressure p1 and temperature T1 is compressed isentropically to dry saturated vapor as shown by the vertical line 1-2 on T-s diagram and by the curve 1-2 on p-h diagram. The pressure and temperature rises from 1 to 2. The work done during isentropic compression is given by: Process 2 3: Constant pressure heat rejection in condenser. The high pressure and temperature vapor refrigerant from the compressor is passed through the condenser where it is completely condensed at constant pressure p2 and temperature T2. The vapor refrigerant is changed into liquid refrigerant. The refrigerant while passing through the condenser, gives its latent heat to the surrounding condensing medium. Process 3 4: Isenthalpic expansion in expansion device. The liquid refrigerant at pressure p3=p2 expanded by throttling process through the expansion valve to a low pressure p4=p1 and temperature T4=T1. Some of the liquid refrigerant evaporates as it passes through expansion valve, but the greater portion is vaporized in the evaporator. During the throttling process no heat is absorbed or rejected by the liquid refrigerant. Process 4 1: Constant pressure heat absorption in evaporator. The liquid vapor mixture of the refrigerant at pressure p4=p1 and temperature T4=T1 is evaporated and changed into vapor refrigerant at constant pressure and temperature. During evaporation, the liquid vapor refrigerant absorbs its latent heat of vaporization from medium (air, water or brine) which is to be cooled. II. LITERATURE REVIEW Yinhai Zhu, Peixue Jiang[1] developed which combines a basic vapor compression refrigeration cycle with an ejector cooling cycle. The ejector cooling cycle is driven by the waste heat from the condenser in the vapor compression refrigeration cycle. The additional cooling capacity from the ejector cycle is directly input into the evaporator of the vapor compression refrigeration cycle. The results show that the COP is improved by 9.1% for R22 system. Ankit Tiwari[2] performances of four ozone-friendly Hydro fluorocarbon (HFC) refrigerants (R125, R134a, R143a and R152a) selected to replace R12 in a vapor compression refrigeration system were investigated experimentally and compared. The performances were evaluated for the investigated refrigerants at various evaporating and condensing temperatures. The results obtained showed that the investigated refrigerants confirmed that R152a and R134a have approximately the same thermodynamic performances similar to R12 while deviation of R125 and R143a were very large. But the best performance was obtained from the used of R152a in the system. As a result, R152a could be used as a drop-in replacement for R134a in vapor compression refrigeration system. The COP of R152a obtained was higher than those of R12, R125, R134a, R143a. Bukola Olalekan Bolaji[3] performance of alternative refrigerants in an adiabatic capillary tube was investigated experimentally in a vapor compression refrigeration system. The mass flow rate was determined at a series of condensing temperatures, varying degree of sub-cooling, and at various lengths of capillary tube. The average mass flow rate of R152a and R134a were 1.2 % lower and 1.9 % higher than that of R12 respectively, under the same operating conditions. The coefficient of performance (COP) obtained using R134a and R152a refrigerants was very close to that of R12 with only 2.6 % and 1.3 % reduction, respectively, while the COPs obtained using R23, R32 and R143a were significantly very low. The performance obtained in a refrigeration system differs among individual selected alternative refrigerants. The differences are larger for R143a, R32 and R23, and the deviation from the performance of R12 is in that order, while the differences are smaller or negligible for R134a and R152a. The best overall performance is obtained using R152a. Gaurav, Raj Kumar[4] The paper analyzes the domestic refrigerator with alternative refrigerants for computing coefficient of performance, exergy destruction ratio, exergy efficiency and efficiency defect. The method of exergy provides a measure to judge the magnitude of energy waste in relation to the energy supplied or transformed in the total plant and in the component being analyzed, a measure for the quality (or usefulness) of energy from the thermodynamic viewpoint and a variable to define rational efficiencies for energy systems. Mahmoud Ghodbane[5] describes simulated performance of R152a and hydrocarbon refrigerants and their potential as alternative refrigerants to HFC-134a in mobile air conditioning systems. In addition, a comparative assessment of the performance of a secondary loop system using these refrigerants is provided. The secondary loop system delivers the same performance and comfort (i.e. cooling capacity) as the R134a baseline system with a small increase in energy usage. Depending on the ambient and driving conditions (i.e. road load and idle), the secondary loop system COPs with R152a as a primary refrigerant and 50/50 ethylene / water mixture as a secondary refrigerant are lower than the baseline by 5 to 12 %. Dr Matthew Bryson[6] focused on developing experience and gaining data with the most likely synthetic drop-in replacement candidates, R152a and HFO-1234yf. The testing regime involved both laboratory bench testing, in a purpose-designed laboratory test bed, and also in-car testing. Both the bench and in-car testing were initially performed using the current industry standard mobile air conditioning refrigerant (R134a) to ascertain a base level of performance of the systems. Both of the replacement refrigerants had COPs and cooling capacities similar to R134a, with R152 having slightly higher values and HFO-1234yf slightly lower. 2015, IERJ All Rights Reserved Page 2

R S Mishra[7] Detailed energy and exergy analysis of multi-evaporators at different temperatures with single compressor and single expansion valve using liquid vapor heat exchanger vapor compression refrigeration systems have been done in terms of performance parameter for R507a, R125, R134a, R290, R600, R600a, R1234ze, R1234yf, R410a, R407c, R707, R404a and R152a refrigerants. The numerical computations have been carried out for both systems. It was observed that first law and second law efficiency improved by 20% using liquid vapor heat exchanger in the vapor compression refrigeration systems. It was also observed that performance of both systems using R717 is higher but R600 and R152a nearly matching same values under the accuracy of 5% can be used in the above system. D.Sendil Kumar, Dr.R.Elansezhian[8] In this paper an experimental investigation was made to reduce the usage of HFC 134a with the Hydrocarbon Refrigerant mixtures (HCM) of R134a and R152a refrigerants in the proportion of 30:70, 50:50, and 70:30 by mass. Experiments were conducted by continuous running tests under an ambient temperature of 32 C. The overall performance of the system proved that the HCM could be a long term alternative for R134a. Jitendra Kumar Verma[9] A refrigerant is a substance used in a heat cycle usually for enhancing efficiency, by a reversible phase transition from a liquid to a gas. Traditionally, fluorocarbons, especially chlorofluorocarbons, were used as refrigerants, but they are being phased out because of their ozone depletion effects. Other common refrigerants used in various applications are ammonia, sulfur dioxide, and non-halogenated hydrocarbons such as propane. R134a is an inert gas used primarily as a high-temperature refrigerant for domestic refrigeration and automobile air conditioners. Contact of R134a with flames or hot surfaces have toxic and hazardous effect on the humans and environment. Sandip P. Chavhan[10] various obstacles faced in working of different refrigerants due to their environmental impact (R11, R12), toxicity (NH3), flammability (HC) and high pressure (CO2); which makes them more hazardous than other working fluids according to safety and environmental issues. We observed the performance of different environmental friendly refrigerants and their mixtures in different proportions. We also observed the effect of working parameters like dimensions of capillary tube, working pressures and working temperatures, which affect the coefficient of performance (COP) of vapour compression refrigeration system. A.Baskaran[11] performance analysis on a vapor compression refrigeration system with various eco-friendly refrigerants of HFC152a, HFC32, HC290, HC1270, HC600a and RE170 were done and their results were compared with R134a as possible alternative replacement. The results showed that the alternative refrigerants investigated in the analysis RE170, R152a and R600a have a slightly higher performance coefficient (COP) than R134a for the condensation temperature of 50⁰ C and evaporating temperatures ranging between -30⁰ C and 10⁰ C.Refrigerant RE170 instead of R134a was found to be a replacement refrigerant among other alternatives. The effects of the main parameters of performance analysis such as refrigerant type, degree of sub cooling and super heating on the refrigerating effect, coefficient of performance and volumetric refrigeration capacity were also investigated for various evaporating temperatures. Ali Kilicarslan[12] Water as a refrigerant (R718) is compared with some current natural (R717 and R290) and synthetic refrigerants (R134a, R12, R22, and R152a) regarding environmental issues including ozone depletion potential (ODP) and global warming potential (GWP), safety (toxicity and flammability), operating cost, refrigeration capacity and coefficient of performance (COP). A computer code simulating a simple vapour compression cycle was developed to calculate COPs, pressure ratios, outlet temperatures of the refrigerants from the compressor, and evaporator temperatures above which water theoretically yields better COPs than the other refrigerants investigated. Bukola O. Bolaji[13] The effects of evaporator temperature on the coefficient of performance (COP), exergy flow destruction, exergetic efficiency and efficiency defect in the four major components of the cycle for R12, R134a and R152a were experimentally investigated. The results obtained showed that the average COP of R152a was very close to that of R12 with only 1.4% reduction, while 18.2% reduction was obtained for R134a in comparison with that of R12. The highest average exergetic efficiency of the system (41.5%) was obtained using R152a at evaporator temperature of -3.0oC. S.Vandaarkuzhali[14] evaluated R152a, hydrocarbon candidates and their potential as a replacement for R134a in mobile air conditioning systems. The performances of R152a in comparison with R22 are presented, from the theoretical as well as from an experimental point of view. The influence of R152a on compressor reliability has been also evaluated analyzing the bearing load and considering both the materials compatibility and the oil solubility; the lower operating temperature has a positive impact on compressor reliability. Some considerations of safety and why we are choosing R152a for our research are also presented. III. REFRIGERANT PROPERTIES Refrigerant properties are necessary to describe the operating characteristics of the refrigerant within a system. In particular, physical properties of refrigerants are useful for determining the applicability of a refrigerant under design operating conditions. Thermodynamic and transport properties of refrigerants are necessary for predicting system behavior and performance of components. Basic properties are provided in Table for more comprehensive data the refrigerant supplier or reference texts should be consulted. 2015, IERJ All Rights Reserved Page 3

Table-1 Physical, safety and Environmental Properties of HFC152a [5] Properties HFC152a HFC134a Chemical CH3CHF2 CH2FCF3 Formula Molecular 66.05 102.03 Mass Critical 235.90 214.00 Temperature ( F) Critical 656.00 589.00 Pressure (psia) Normal Boiling -11.20-15.00 Point ( F) Lubricant N/A POE/PAG Stability Stable Stable OSHA 1000 1000 Permissible Exposure Limit (ppm) Lower Flammability (% Volume in Air) 4.80 None Heat of 7481 1806 Combustion (Btu/lbm) Safety Group A2 A1 Auto Ignition 851 1418 Temperature ( F) Atmospheric 2 14 Life (yr.) Ozone 0 0 Depletion Potential Global Warming 120 1430 Potential (100 yr.) countries have been provided a grace period of ten years i.e. phase out by 2040. 3) Global warming is another serious issue. Some naturally occurring substances mainly cause this but CFCs have very large global warming potential. Kyoto Protocol Kyoto protocol aims at phasing out of substances that will lead to global warming. And R134a is used in domestic refrigerator and other vapour compression systems as it was identified as a replacement to CFC-12, keeping in view its zero ozone depleting potential. R134a has 1300 global warming potential per 100 year, which is very high. The sale of R134a reported to AFEAS 1970-2003 [21] is significantly increasing during the past two decades. The increased emission of R134a to the atmosphere are steadily increasing the concentration of green house gases via leaks and mostly, in an indirect way, via energetic performance of refrigeration plant. This will lead to adverse climatic problem. Hence, R134a is one of the six chemicals in the basket that are to be phased out in the near future under Kyoto protocol[9]. Environmental concern There are two major concern of environmental concern. 1) The first major concern is depletion of ozone layer. Ozone layer is a layer which protects the earth from ultraviolet rays. Ozone depletion potential is evaluated on a scale that uses CFC-11 as a benchmark. All the other components are based on how damaging to the ozone they are in relation to CFC-11[9]. 2) The second major concern is global warming. Global warming is the increase in global earth surface temperature due to the absorption of infrared emission from earth surface. Global warming potential is evaluated on a scale that uses CO2 as the bench mark i.e. CO2 is assigned a value and other components are compared to CO2[9]. Results from Literature survey Need for Alternatives of R134A Since 2010 to onwards be the fourth generation is being focusing on refrigerants that do not contribute to global warming, ozone layer depletion, efficient, non flammable and non toxic with good stability. But the outlook for discovery or synthesis of these ideal refrigerants is extremely unlikely. Therefore, trade-off among desired objectives is necessary to achieve the balanced solution [9]. Montreal Protocol The United Nations environment programme conference held in Montreal in September 1987 the decision taken to phase out ozone depleting substances (ODS) within a fixed time period is known as Montreal Protocol. Some of the feature of MP is as follows[9]. Fig.3. Refrigerating effect Vs evaporating temperature[11] 1) Developed countries will phase out CFCs by 1996. 2) Developing countries will phase out CFCs by 2010 with freeze in 1999 and gradual reduction thereafter. Developed countries will phase out HCFCs by 2030 while developing 2015, IERJ All Rights Reserved Page 4

Fig. 4.Compression Work Vs evaporating temperature[11] Fig.5. Coeffiecient of performance Vs Evaporation temperature[11] IV. CONCLUSION From the literature survey it is clear that refrigerant R134a is having higher global worming potential (GDP) than R152a and it can be concluded that, refrigerant R152a have slightly higher COP, Cooling capacity, condenser capacity, energy efficiency than R134a. Hence considering above mentioned protocols and the results obtained from the experimental work refrigerant R152a is a good alternative for R134a. REFERENCES [1] Yinhai Zhu, Peixue Jiang, Hybrid vapor compression refrigeration system with an integrated ejector cooling cycle, international journal of refrigeration,2012 [2] Ankit Tiwari, Prof. S.S Pawar, Asst.Prof. Sachin Baraskar, Variation of Performance of Refrigeration System at different Temperature, International Journal of Engineering Sciences & Research Technology,July, 2014 [3] Bukola Olalekan Bolaji, PERFORMANCE ANALYSIS OF R12 ALTERNATIVES IN ADIABATIC CAPILLARY TUBES OF A REFRIGERATION SYSTEM, Eng. Rev.(2010) [4] Gaurav,Raj Kumar, Performance Analysis of Household Refrigerator with Alternate Refrigerants, International Journal of Innovative Research in Science, Engineering and Technology Vol. 3, Issue 4, April 2014 [5] Mahmoud Ghodbane, An Investigation of R152a and Hydrocarbon Refrigerants in Mobile Air Conditioning, SAE TECHNICAL PAPER SERIES International Congress and Exposition Detroit, Michigan March 1-4, 1999 [6] Dr Matthew Bryson, Chris Dixon etc, Testing of HFO- 1234yf and R152a as mobile air conditioning refrigerant replacements, RMIT University Forum,May 2011 [7] R S Mishra, Thermodynamic Performance Evaluation of Multi-Evaporators Single Compressor and Single Expansion Valve and Liquid Vapour Heat Exchanger in Vapour Compression Refrigeration Systems using Thirteen Ecofriendly Refrigerants for Reducing Global Warming and Ozone Depletion, International Journal of Advance Research and Innovation, ISSN 2347 3258, Volume 1, Issue 3 (2013) 220-228 [8] D.Sendil Kumar, Dr.R.Elansezhian, Investigation of R152a/R134a Mixture in Refrigeration System, International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 6, ISSN: 2277-3754 December 2012 [9] Jitendra Kumar Verma, Ankit Satsangi, Vishal Chaturani, A Review of Alternative to R134a (CH3CH2F) Refrigerant, International Journal of Emerging Technology and Advanced Engineering, ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 1, January 2013 [10] Sandip P. Chavhan, Prof. S. D. Mahajan, A Review of an Alternative to R134a Refrigerant in Domestic Refrigerator, International Journal of Emerging Technology and Advanced Engineering, ISSN 2250-2459, ISO 9001:2008 Certified Journal, Volume 3, Issue 9, September 2013 [11] A.Baskaran, P.Koshy Mathews, A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential, International Journal of Scientific and Research Publications, 1 ISSN 2250-3153,Volume 2, Issue 9, September 2012 [12] Ali Kilicarslan and Norbert M.uller, A comparative study of water as a refrigerant with some current refrigerants, INTERNATIONAL JOURNAL OF ENERGY RESEARCH Int. J. Energy Res. 2005; 29:947 959 Published online 18 July 2005 in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/er.1084 [13] BUKOLA O. BOLAJI, EXERGETIC PERFORMANCE OF A DOMESTIC REFRIGERATOR USING R12 AND ITS ALTERNATIVE REFRIGERANTS, Journal of Engineering Science and Technology Vol. 5, No. 4 (2010) 435-446 School of Engineering, Taylor s University [14] S.Vandaarkuzhali, INVESTIGATION ON R152A AS A SUBSTITUTE FOR R22 IN COMMERCIAL AIR CONDITIONING SYSTEM A REVIEW, Journal of Selected Areas in Mechatronics (JMTC) Singaporean Journal of Scientific Research(SJSR) Vol.6.No.6 2014 Pp. 260-275, Paper Received :05-08-2014,Paper Accepted:23-08-2014 2015, IERJ All Rights Reserved Page 5