ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Similar documents
ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Eclipse AirHeat Burners

Eclipse AirHeat Burner

Series LV AIRFLO. In-duct firing line burner

Specifications of V-Line burners

"NP" & "RG" AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

"HC" AIRFLO. In-duct firing line burner

V-Line. Nozzle-mix line burner

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

DELTA-TE III. Nozzle-mix line burner

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

Eclipse ER Indirect Air Heater

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

ECLIPSE INFORMATION GUIDE

INDITHERM. Low temperature gas burners

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

ECLIPSE INFORMATION GUIDE

C1050ES Tankless Water Heater

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Residential/Commercial Gas Condensing Tankless Models

NMC Nozzle Mix Gas/Oil Combination Burners

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

INDITHERM. Low temperature gas burners

C1210ES Tankless Water Heater

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Direct Fired Heater Model AD Specification

iq251, Gen II Submittal Data

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

OPERATING AND MAINTENANCE MANUAL

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

TUBE-O-THERM Low Temperature Gas Burners

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Tankless Condensing High Efficiency Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

SUBMITTAL SCHEDULE & DATA

940ES Tankless Water Heater

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

940ES Tankless Water Heater

Residential Gas Tankless Water Heater

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

INFRARED RADIANT HEATERS

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Design and Application Details

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Eclipse 90 UV Scanner Model A Version 1

Specifications of MULTIFIRE burners

Commercial Tankless Rack System

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

Installation Instructions

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

DIVISION FINNED WATER-TUBE BOILERS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

Commercial Tankless Rack System

Eclipse RatioMatic Burners

DIVISION FINNED WATER-TUBE WATER HEATERS

STR-Series Indirect-Fired Air Turnover Units

Boiler Basics. Design and operation

CSD-1 COMMERCIAL BOILER CONTROLS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

FLAT FLAME AND EXCESS AIR BURNERS

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

Triton Series High Efficiency Boiler

PRE-PLANNING GUIDE for the Linear Burner System

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

U n i t H e at e r s

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

DIVISION FINNED WATER-TUBE WATER HEATERS

High efficiency, cast-iron gas boiler

C1210ESC Tankless Water Heater

Commercial Tankless Rack System

esfr dry pendent sprinkler Vk502 (k14.0)

FIREYE FLAME SCANNERS

Commercial Tankless Rack System

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Transcription:

Bulletin 16C 8/ ECLIPSE AH-MA BURNERS Air Make-Up Burners Designed for trouble-free make-up or process air heating. Eclipse AH-MA burners produce a uniform, odorless, and smokeless flame ideal for heating fresh air in make-up and process air heating applications. The AH-MA design provides stable operation over a wide range of velocities, inputs and fuels. AH-MA easily passes all global standards for indoor air quality through a wide operational range. It is ETL listed, complying with ANSI Z21.2 design standards, and is used in systems which meet ANSI Z83.4 / CGA 3.7 emissions standards for NOx and CO. The new aluminum burner body creates a lightweight, corrosion resistant burner. Cast iron and corrosion resistant cast iron bodies are also available. Divergent air wings are made of stainless steel. The burner bodies supply fuel to the center of the air wings to control the air and fuel mixture inside the burner and to optimize emissions and efficiency. Low pressure models require only a 6." w.c. ΔP natural gas at 8, Btu/hr/LF, making them ideal for use with the Maxitrol Selectra control valve. Ready for the world AH-MA burners combine advanced engineering with installation and operational features that are truly world class. Assembled from straight sections, tees and crosses to produce nearly any configuration required. Inputs up to 1,2, Btu/hr/LF Up to 3:1 turndown Up to 45 F upstream air temperature. Up to 85 F downstream air temperature. Multi-fuel capability (natural gas, propane and butane) In addition to the many user-preferred features of AH-MA, Eclipse offers you a comprehensive, global network of service with more years of air-heating experience than any other burner manufacturer. E C L I P S E

AH-MA Burners Ideal for make-up air heating applications Adjustable Profile Plate Uniform Air Flow Flame Length Burner Body Gas Feed Pipe Heated Air Uniform Air Flow Air WIng Adjustable Profile Plate Bulletin 16C 8/ Litho in USA

Data 16 11/7/4 AirHeat Burners AH-MA Series Version 2.2 Main Specifications Parameter Description Input (Btu/hr./ft.) Combustion Airstream Pressure Drop/Velocity Ignition Pilot Integral Pilot Capacities 1,2, maximum.2" to 1.4"w.c. Direct spark ignition (6VAC). Interruptible pilot for natural gas, propane or butane. 2, Btu/hr. Burner Bodies Standard Aluminum Low Pressure Aluminum* Standard Cast Iron Corrosion Resistant, EN Plated Cast Iron Low Pressure Cast Iron* Burner Section Sizes 15mm (6") straight section 3mm (12") straight section 3mm (12") straight section with back inlet 3mm (12") straight section with pilot 15mm (6") by 3mm (12") tee section 15mm (6") by 3mm (12") tee section with pilot 3mm (12") by 3mm (12") cross section Pipe Threads N.P.T. or B.S.P. Maximum Upstream Air Temp. 45 F (232 C) Maximum Downstream Air Temp. 85 F (454 C) Maximum Temperature Rise 75 F (4 C) Minimum Inlet Air Oxygen (O2) 18% Flame Detection** Flame rod or scanner. Fuels Natural gas, propane or butane. * For use with Natural Gas only. ** Burners over 5 lineal feet include flame supervision at the far end. If pilot ignition is being used, two flame supervision units are required; one for the pilot and one for the far end. If using direct spark on the main flame, only flame supervision at the far end is required providing ignition can be accomplished within 15 seconds. (Reference NFPA Requirement 5-9.2.2) Eclipse reserves the right to change the construction and/or configurations of our products at any time without being obliged to adjust earlier supplies accordingly. All information is based on laboratory testing. Different chamber size and air flow conditions may affect the data. All information is based on standard conditions (7 F at sea level). Contact Eclipse for performance data above ambient temperature. All inputs based on gross caloric values.

Operating Range & Duct Pressure Measurement 1,3, 1,2, 1,1, 1,, Heat Input (Btu/hr./ft.) 9, 8, 7, 6, 5, 4, 3, 3, Maximum Heat Input Natural Gas Propane/Butane 25, 2, 15, Minimum Heat Input 1, 5,.2.4.6.8 1. 1.2 1.4 ("w.c.) @ 7 F Air Inlet Inlet Air Temperature Correction Air Press. Drop @ Air Temp. = Air Press. Drop from Oper. Range Chart x Correction Factor Air Inlet Temp. ( F) 3 7 15 2 25 3 35 4 45 Correction Factor.87.92 1. 1.15 1.25 1.34 1.43 1.53 1.62 1.72 Air Velocity Calculation Air Velocity (fpm) = 196.2 ("w.c.) Air Density (lbs./cubic ft.) 2 Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4

Differential Pressure Measurement & Burner Gas Pressure Drops "A" Tap On Inlet Gas Piping Main gas differential pressure measured between A and D 1-2" D (254-58mm) Gas Pressure Drop ("w.c.), Burner Inlet to Duct 3 25 2 15 1 5 Natural Gas* Propane* Butane* Natural Gas (Low Press.)* * 2 4 6 8 1, 1,2 Heat Input (1 s Btu/hr./ft.) * 2.mm gas ports. * * 2.4mm gas ports Flame Lengths Flame Length Note: Flame length may vary slightly from these values depending on actual fuel, air handling system, duct configuratons and profile plates uses. Flame Length (Inches) 7 6 5 4 3 2 1.4"w.c..7"w.c. 1."w.c. 1 2 3 4 5 6 7 8 9 1, 1,1 1,2 Heat Input (1 s Btu/hr./ft.) Emissions Data NOx (ppmvd @ 3% O2) 1 9 8 7 6 5 4.4"w.c. 3.7"w.c. 2 1."w.c. 1 2 4 6 8 1, 1,2 Input (1 s Btu/hr./ft.) CO (ppmvd @ 3% O2) 18 16 14 12 1 8 6 4 2.4"w.c..7"w.c. 1."w.c. 2 4 6 8 1, 1,2 Input (1 s Btu/hr./ft.) Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4 3