i200x/i201x & i250x/i251x Submittal Data Date: Project Name: Project #: City/St/ZIP: Engineer: Contractor: Bid Date: Model Selected: i200x i250x i201x i251x Fuel Type: Natural Gas Propane Accessories: Under-sink recirculation valve Key Features Stainless (316L) domestic water heat exchanger Flexible-floating design, stress relieving and thermal shock capable ASME U-rated brazed plate-type heat exhanger. Operates on gas pressures range of 2.5"-14" w.c. ASME-H compliant (i201x & i251x) Built-in domestic recirculation: use under-sink valve part # IGT-SPR0061 Heating & Domestic Hot Water Performance Model 1 Space Heating input(mbh) Heating Capacity 2 DHW Capacity @ AFUE (%) Min Max (MBH) 77 F (GPM) i200x / i201x 30 142 125 90.2 5.0 i250x / i251x 30 142 125 n/a 6.0 1 Ratings are the same for Natural Gas or if field converted to Propane. 2 Capacity is based on tests caried out by a nationally accredited lab and tested in accordance to the U.S. Department of Energy (DOE) test procedure 10CFR Section 430.23(n).
Space Heating Side - Pressure Drop 10 4.3 PRESSURE DROP (FT OF HEAD) 8 3.5 6 2.6 4 1.7 2.86 (PSI) 0 0 0 2 4 6 8 10 12 FLOW RATE (GPM) Clearances Side Back Top Side Required Mounting Clearances Location From From Non- Service Combustibles Combustibles Clearance 1 Top 6" (15.2cm) 20" (50.8cm) 12" (30.4cm) Back 2 5/8" (15.8mm) 5/8" (15.8mm) 5/8" (15.8mm) Sides 1" (25.4mm) 1/2" (12.7mm) 5/8" (15.8mm) Front 2" (5.1cm) 2" (5.1cm) 30" (76.2cm) Bottom 12" (30.4cm) 12" (30.4cm) 12" (30.4cm) 1 Service clearances are suggested to allow for normal service 2 Mounting bracket automatically sets this dimension Front Bottom
Electrical Data Electrical power required for the water heater is 120V AC, 60 Hz. The circuit breaker shall be a minimum of 5 amps. Only one water heater should be plugged into an outlet. Please ensure correct polarity of outlet before plugging in heater. Dimensional Specifications TOP VIEW BOTTOM SPACE HEATING: SUPPLY - 1 NPT SPACE HEATING: RETURN - 1 NPT WEIGHT: 98 LBS. FRONT VIEW SIDE VIEW
Space Heating Sizing Please use the following charts to evaluate the application type and unit performance MARINE San Francisco. Seattle. Boise. Billings. Santa Fe Los Angeles.. HOT-DRY / MIXED-DRY.Denver VERY COLD Minneapolis. Dallas. Chicago. COLD. Boston. New York.Washington D.C. St. Louis. Richmond. Nashville. Atlanta. MIXED-HUMID HOT-HUMID. Miami 1. Locate your area on the map. Note the corresponding climate region. 2. Refer to the table below to look up the total area of house allowed for each type of application in that region, along with the insulation situation. Well- (typ > R-17) Adequately- (typ ~ R-13) Poorly- (typ < R-10) Climate Area High-Temp Baseboard Typ temp 180/160, 5 GPM Total House Area (Sq. ft.) Air-Coil In-Floor Radiant Low Mass Radiant Typ temp 160/140, 6 GPM Typ temp 120/100, 12 GPM Very Cold 2,050 2,500 4,950 4,100 Cold 2,600 3,100 6,150 5,150 Mixed-Humid 3,200 3,800 7,600 6,350 Mixed-Dry/Hot-Dry 5,000 6,000 11,950 10,000 Hot-Humid 6,750 8,050 16,100 13,450 Marine 3,650 4,400 8,750 7,300 Typ temp 140/120, 10 GPM Very Cold 1,750 2,100 4,200 3,500 Cold 2,200 2,650 5,250 4,350 Mixed-Humid 2,700 3,250 6,450 5,400 Mixed-Dry/Hot-Dry 4,250 5,100 10,200 8,500 Hot-Humid 5,750 6,850 13,700 11,450 Marine 3,100 3,750 7,450 6,200 Very Cold 1,550 1,850 3,650 3,050 Cold 1,900 2,300 4,550 3,800 Mixed-Humid 2,350 2,850 5,650 4,700 Mixed-Dry/Hot-Dry 3,700 4,450 8,850 7,400 Hot-Humid 5,000 5,950 11,900 9,950 Marine 2,700 3,250 6,450 5,400 Note: Table is computed based on housing and BTU data collected by the U.S. Energy Information Administration (EIA) & Intellihot performance. Please contact your local contractor or Intellihot representative for individualized applications.
Specifications PARAMETERS MODEL i200x/i201x* i250x/i251x* Type Fuel Indoor, Wall-Hung, Fully Condensing, Direct Ignition Preset for NG / LP Convertible Minimum / Maximum Input (Btu/h) 30,000 / 199,950 30,000 / 250,000 Thermal Efficiency 94% 92% Energy Factor 0.93 N/A Appliance Annual Fuel Utilization Efficiency (AFUE) 90.2% N/A Combined Appliance Annual Fuel Utilization Efficiency (CAFUE) 91.4% N/A Dimensions H X W X D (inches) Weight Water and Gas Connections Space Heating Connections Minimum Flow Rate Venting Materials 26 X 17.4 X 14.9 (3.9 cu. ft) 98 lbs 3/4 NPT 1 NPT No minimum flow rate in learned or programed modes Sch. 40 PVC, Sch. 40 CPVC, Polypropylene, Stainless Steel Max 3 Vent Length - Single Pipe / Power Vent 200 ft, deduct 5 ft per 90 elbow 130 ft, deduct 5 ft per 90 elbow Max 3 Vent Length - Two Pipe / Direct Vent 100 ft, deduct 5 ft per 90 elbow 65 ft, deduct 5 ft per 90 elbow Max 2 Vent Length - Single Pipe / Power Vent 26 ft, deduct 5 ft per 90 elbow N/A (2 not allowed at elevations above 4,000 ft) Max 2 Vent Length - Two Pipe / Direct Vent (2 not allowed at elevations above 4,000 ft) 21 ft, deduct 5 ft per 90 elbow N/A Safety Flame Rod, Thermal Fuse, Overheat Prevention Device, Fan Speed Monitor, Flue Temperature Monitor, Blocked Vent Detector, Water Shut-Off Valve, 2X10A Fuse, Dual Flame Sensing Water Pressure Min / Max (PSI) 30 / 150 NG/LP - Minimum Static Gas Pressure 1/2 Black Iron (non-corrugated) 5 6 NG/LP - Minimum Static Gas Pressure 3/4 Black Iron 2.5 (non-corrugated) NG/LP - Maximum Static Gas Pressure Gas Pressure for Adjustments Electrical Power Consumption 14 8 for NG, 11 for LP 120V AC, 60 Hz 500W (Max 4.2 Amps), 8W (Standby) FEATURES & PERFORMANCE i200x/i201x* i250x/i251x* Space Heating Heat Exchanger Domestic Water Heat Exchanger Stainless Brazed Plate, Stainless 316L Hot Water Capacity (35F Rise) 10.8 13.2 Hot Water Capacity (45F Rise) 8.4 10.3 Hot Water Capacity (77F Rise) 5.0 6.0 Domestic Hot Water Temperature Settings 100 140 F Space Heating Temperature Settings 100 180 F Note: Due to Intellihot s policy of continuous product improvements, design and technical specifications are subject to change without notice. WARRANTY (with recirculation) Residential: Heat Exchanger Coil 12 years, Parts 3 years, Labor 1 year Commercial: Heat Exchanger Coil 6 years, Parts 1 year *ASME H certified Intellihot Green Technologies Inc. 2900 W. Main Street, Galesburg, IL 61401 phone: 877.835.1705 email: sales@intellihot.com www.intellihot.com (i201x & i251x) (i201x)