Medium Dut y Advanced Heating & Hot Water Systems Single Phase or 3 Phase Operation Field Convertible Models: to 1 Gal. Large Volume 3 Phase Commercial Point of Use Single Phase Only Junction Box & Terminal Block for Easy Wiring & Conversion ( Large Volume 3 Phase Models) Industry Best Year Commercial Warranty
The Everlast Commercial Electric Water Heater combines high quality stainless steel construction and energy efficient operation, providing long draws of hot water without consuming large amounts of energy. Durable components, low standby heat losses, high recovery rates, and the industry s strongest warranty make the Everlast Commercial Electric Water Heater an ideal choice for electric water heating needs. Thermostat and high limit controls: Adjustable temperature range up to 1º F on all models The finest protection: Laser welded with a concentrated heat source producing high quality, long-lasting welded joints. 3L stainless steel tank (lightweight) - Superior corrosion resistance, eliminates the need for anode rods, protects against harsh water conditions for a lifetime of durability against leaks - Limited year warranty (with online registration, 5 if not registered) Minimal heat loss: Heavy-duty insulation 3" on the top & 2" on the sides ADE RODS NEEDED RESISTS SCALE BUILD UP LIGHT WEIGHT Incoloy & Stainless steel elements: Low watt density, incoloy sheathed and stainless steel screw plugs increase corrosion resistance and helps prevent scale build-up for longer element life versus conventional elements - % efficient heat transfer STANDARD FEATURES - 3L Stainless Steel Tank - Heavy Duty Insulation - Heat Traps - Incoloy & Stainless Steel Elements - Electrical Connection Box - Limited year warranty (with online registration, 5 year warranty if not registered) IN THE BOX - T&P Relief Valve - Installation Manual - Brass Full Port Drain Valve - Dip Tube & Outlet Nipple (--50--0-1 Models) Combination Cold Inlet & Drain Fitting (-- Models) Thermostat and high limit controls / Adjustable temperature range Provides the finest protection against harsh water conditions with the best warranty in the industry Directs cold water to the bottom of the tank and minimizes mixing of cold water providing long draws of hot water Single phase or 3 phase operation Field convertible (--50--0-1 Models)
RE E EVERLAST MD COMMERCIAL Large volume 3 Phase EVC0, EVC0, EVC050 EVC0, EVC0 & EVC1 Standard: Two 2 volt, three phase, non-simultaneous (unbalanced) configuration with 4500W elements (available in other configurations) Water heaters can be converted to single phase and/or simultaneous operation in the field (dual element models only). Top inlet with dip tube directs cold water to the bottom of the tank, minimizing the mixing of cold and heated water and providing long draws of hot water 3/4 inlet and outlet nipples constructed of durable brass HOT WATER OUTLET E COLD WATER INLET T&P Valve T&P Valve - Alternate Two Stainless Steel Incoloy Elements Electrical Junction Box & Terminal Block Cold Inlet ELECTRICAL ACCESS PANEL Drain 45.00 45.00 T & STAT D Product Ships with Installed Elements C TEMPERATURE PRESSURE RELIEF VALVE B ELEMENT & THERMOSTAT ACCESS TANK DRAIN Specifications and Dimensions (3 Phase Option) Water Temperature Ratings Models Gal. A B C D E Shipping Hot/Cold Minimum Maximum High Weight Water Delivered Delivered Temp. Est. Inlets Temp. Temp. Limit EVC0C2T045 6 42. 1.5 lbs EVC0C2T045 6 E 46 54. 1.5 4 lbs EVC050C2T045 50 6 5 66.5 1.5 1 lbs HOT WATER COLD WATER ¾ 1 F. F 0 F EVC0C2T045 6.5 60" 6. 1 lbs NPT 4. C 2.1 C 3.3 C OUTLET INLET EVC0C2T045 0. 52" 61 2 6 lbs EVC1C2T045 1. 60 6 2 4 lbs ELECTRICAL # Elements and Non-Simultaneous Simultaneous ACCESS PANEL 1 2 2 4 # Thermostats Elements and Non-Simultaneous Simultaneous 1 2 2 4 Thermostats 3,000 6,000 YES YES YES 3,000 3,500 6,000,000 YES YES YES,, 50, 4,000 3,500,000,000 YES YES YES YES,,, 0, 50, 2 4,000 4,500,000,000 YES YES YES YES, 1 0, 2 5,000 4,500,000,000 YES YES YES YES 1 5,000 5,500,000 45.00 45.00,000 YES YES YES YES 6,000 5,500,000,000 YES YES YES 6,000,000 YES YES YES Single and Three Phase Non- AMPERAGES Simultaneous Operation Input Single Simultaneous and Three Operation Phase Non- Input Volts 2 Simultaneous Volts Operation 2 Volts 4 Volts Wattage Input Simultaneous 2 Operation 2 4 Wattage Input Single Volts Three Single 2 Volts Three Single 2 Volts Three Single 4 Volts Three Wattage Volts Volts 2 Volts 2 Volts 4 Wattage Single Phase Phase Three Single Phase Phase Three Single Phase Phase Three Single Phase Phase Three 3,000 Volts.4 Volts.5 Volts. Volts 6.3 6,000 Phase. Phase Phase Phase 21.6 Phase 24.1 Phase. Phase.5 Phase. 4,000 3,000 1..4.5..4. 6.3.3,000 6,000. 3..4 33.3. 21.6. 24.1..5..4. 4,000 4,500 1. 21.6....4.4.3,000,000 43.3 3..4 3.4 3.5 33.3. 32.4. 33. 2.1...2.4 5,000 4,500. 21.6....4.4,000,000 45. 43.3 3.5 3.4 41. 3.5 32.4.1 33. 2.1.2...2 5,000 5,500. -.. 1.2.4.5,000,000 45. - 3.5-45. 41. 3. 3.5.1.2 33.3.. 1. 6,000 5,500 -. 1.2 21.6.5.5,000,000 - - 4. 45. 43.2 3. 3.5 43.3 3.4 33.3. 1. 21. 6,000-21.6.5,000 - - 4. 43.2 43.3 3.4 21. A
EVERLAST MD COMMERCIAL Point of Use Single Phase EVC0, EVC0 & EVC0 Standard: Single Phase, 2V Configuration with 4500W Element Electric Junction Box located on top of water heater for easy wiring and installation 3/4 inlet and outlet nipples constructed of stainless steel Bottom cold water inlet directs cold water to the bottom of the tank, minimizing the mixing of cold and heated water and providing long draws of hot water 3L Stainless Steel Tank Connection Box Stainless Steel Incoloy Element T& P Valve - Alternate Stainless Steel Screw-in Plug Cold Inlet & Drain Fitting EVC0, EVC0, EVC0 HOT WATER OUTLET Product Ships with Installed Elements Specifications and Dimensions ( Single Phase Only) Models Gal. A B C D Shipping Weight Est. Hot/Cold Water Inlets Water Temperature Ratings Minimum Delivered Temp. Maximum Delivered Temp. High Temp. Limit UEF EVC0C1X045 4.5..5 1.5 42 lbs TBD 1 F. F 0 F ¾ EVC0C1X045 4.5..5 1.5 46 lbs NPT 4. C 2. C 3.3 C. EVC0C1X045 4.5 21.5 2 1.5 50 lbs.2 4.5 60.00 ELECTRICAL ACCESS PANEL # of Elements Available Wattage Voltage (and Element Part #) 1 2 2 Phase TEMP/PRESSURE RELIEF VALVE 3/4" F-NPT D 1,500 A1X0N B1X0N C1X0N D1X0N 2,000 A1X0N B1X0N C1X0N D1X0N 2,500 A1X0N B1X0N C1X0N D1X0N 1 3,000 A1X0N B1X0N C1X0N D1X0N 3,500 - B1X035N C1X035N D1X035N 1 4,000 - B1X0N C1X0N D1X0N 4,500 - B1X045N C1X045N D1X045N 5,000 - B1X050N C1X050N D1X050N C B Input AMPERAGES - Single Phase Operation / Non-Simultaneous Operation Wattage 1 2 2 1,500 6 2,000 2,500 21 3,000.4.5. A COLD WATER INLET ELEMENT AND THERMOSTAT ACCESS 3,500 -.3.6.1 4,000 -- 1...4 4,500-21.6.. 5,000 --..
Commercial Electric RecoverY Recovery Table for Commercial Electric Water Heater (US per Hour) Input Temperature Rises (deg. F) W 50 60 0 0 0 1 BTU 00 51 6 5 00 624 00 5 00 6 24 3500 42 35 00 64 41 32 2 4500 355 46 26 5000 061 51 2 5500 6 56 3 24 6000 43 61 4 41 2 24 0 56 4 35 000 5 00 22 64 53 46 32 2 000 0 0 2 60 51 45 33 000 1 0 6 5 50 100 35 1 3 63 55 4 0 46 1 6 6 60 53 4 Commercial Many Commercial Applications 1 5 0 5 6 1 4 6 2 33 3 3 26 2
Our Components are Made of Durable Materials: 3L Stainless Steel Tank Construction Stainless Steel Incoloy Element Inlet and Outlets Constructed of Durable Brass (--50--0-1 Models) Stainless Steel Dual Port Outlets (-- Models) The Advantages Stainless Steel VS Glass-Lined HTP s Stainless Steel Tank Lightweight Top Competitor s Glass-lined Tank Very Heavy Minimizes Scale Build Up Prolongs Tank Life No Need for Anode Rods Lightweight Construction Anode Rods Needed! All coated tanks require anodes to delay the inevitable corrosion and tank failure. The average coated water heater lasts about years. The Everlast stainless steel tank will outlast any coated steel tank in the market. SCALE BUILD UP MODEL NUMBERS Everlast Commercial Electric Stainless EVC 0 Volume In Product ordering information Rated Voltage A = 1 B = C = 2 D= 2 E = 4 C2X0N Number of Elements Input Rating (0 s of Watts) Element Construction N = Stainless Steel Screw-In Phase/Operation X = Single Phase - Staged W = Single Phase - Simultaneous T = 3 Phase Total Wattage Recovery at 0 F Rise First Hour Delivery / / 1,500 /.5 / 21 / / 2,000 / 1.5 / / / 3,000 21 / 24.5 / / / 4,000 /.5 / 32 / / 4,500 2 /.5 / / / 5,000 / 33.5 / 3 //50//0/1 6,000 2 4/55/62/3//.5 //50//0/1,000 41 62/6/6//4/1.5 //50//0/1,000 46 6/4/1/2/6/6.5 //50//0/1,000 55 6/3/0/1/1/5 22 Duchaine Blvd, New Bedford, MA 0245 www.htproducts.com MKTLIT-4 05 / HTP In accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice.