Webinar November 12, 2014

Similar documents
DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

HOW TO CHOOSE THE RIGHT PROTECTION FOR FIRES, FLASH FIRES & ARC FLASHES

The Basics Arc Flash Protection

Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE

Flame Resistant Clothing: Statistics, Standards and Safety

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Using Disposable Garments in Arc Flash Exposures

AN UNCOMPROMISING COMMITMENT TO SAFETY

NFPA 70E Electrical Safety in the Workplace

Combustible Dust with FR Clothing June Service Experience Trust Quality Flexibility

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

AN UNCOMPROMISING COMMITMENT TO SAFETY

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NFPA 70E Electrical Safety & Arc Flash Training

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

WELCOME. NOMEX Protective Apparel Solutions Seeheim, 6/7 th April DuPont s registered trademark. TM DuPont s trademark.

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

NFPA 70E Edition Update

DON T GET BURNED BY THE CONFUSION:

NECA S System Approach to Electrical Safety for NFPA 70E

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Brian McCauley December 2017

Electrical Safety Compliance: NFPA 70E

Technical Committee on Flash Fire Protective Garments

NECA S System Approach to Electrical Safety for NFPA 70E

6/23/ National Electrical Contractors Association and Intec, Inc.

Applying the 2012 NFPA 70E. Arc Flash Standard

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

Safety Meeting Topic #37 NFPA 70E What is it?

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

Electrical Hazards and NFPA-70E: Protecting Your Employees

NECA. Standard for Electrical Safety in the Workplace

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

Flame retardant. Protectivewear fabrics by Klopman International

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

NFPA Overview. International Titanium 2014 Conference Chicago Kevin L. Kreitman

Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics

Committee on NFPA 2113

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Arc Fault Detection Devices (AFDDs) Protecting People and Property

NFEC FIRE SAFETY SEMINAR Krish Mysore

UL Conference Atlanta May 21 22, 2014 Polyurethane Foam Association presentation

PROTECTING AGAINST ARC FLASH HAZARDS

Arc Flash Protection Training - NFPA 70e Electrical Safety

SALISBURY ASSESSMENT SOLUTIONS

Honeywell Salisbury PrismShield Colors within Sight, Safety on Site

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

7.1 Smoke Detector Performance

Fire Safety in a Laser Lab

FLAME RESISTANT WORKWEAR (FRW) A Program Development Guideline

How many time has your company been asked by an owner or customer to work on equipment energized?

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

2660 Horizon Drive SE Grand Rapids, MI FIRE PREVENTION FACILITATOR S GUIDE

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION actoolsupply.com

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

DuPont NFPA Certified Attire

COMBUSTIBLE DUST AN EXPLOSIVE ISSUE NFPA 654

2014 National Electrical Code & NFPA 70E/Arc Flash

IEC and CENELEC standards used to protect the electrical worker against an Arc Flash

OBERON USER GUIDE Arc Flash Suit Care & Use

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Electric Fire Pump Controller Inspection, Test & Maintenance Arc Flash Hazard White Paper

MACHINERY & EQUIPMENT INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat.

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Electrical Safety Program.

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

The safe way to verify the absence of voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

Fire Prevention Plan Program

EMERGENCY PHONE: or (651) (24 hours)

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

NFPA 70E Elevates Safety. with Heightened Risk Awareness

LIGHTING in Hazardous (Classified) Locations

PROTEK PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR

Transcription:

Webinar November 12, 2014 Dennis L. Mater dennis.l.mater@dupont.com FR Apparel Sales Technical Leader North America

Webinar Overview Introduction Hazard Risk Types Contrast Short Duration Fire and Arc Flash Hazard Characteristics Industry Standards and Test Methods Garment Performance Conclusions and Summation Questions and Answers 2

3

Introduction Hazard Risk Types Is Your Primary Hazard Fire? Short Duration Fires Fuel Sources Flash - Rapid Burning of Vapor Cloud Jet - Burning of Pressurized Fuel Supply Pool - Burning of Flammable Liquid Spill BLEVE - Explosion & Fireball from Catastrophic Failure of Contained Liquid - Flammable Liquids - Flammable Gases - Combustible Dusts Can Ignite / Melt Typical Work Clothing Burn Unprotected Skin Which Type of Fire Hazard Do You Have? 4

Physical arc is created when electricity conducts unpredictably between exposed phases or to ground Arc Flash can occur in low voltage (LV) and high voltage (HV) electrical systems Arc flash events can be caused by: Human error or improper training Poorly maintained equipment Equipment failure Poorly designed electrical systems Can Ignite / Melt Typical Work Clothing Burn Unprotected Skin Introduction- Hazard Risk Types Is Your Primary Hazard Electrical? Arc Flash Are The Majority of Your Workers Exposed to Arc Flash Risks? 5

Introduction Hazard Risk Types Do You Have A True Dual Hazard Risk? Full understanding of the true hazard risk is imperative Short duration fires and arc flash events pose different hazards Proper worker PPE (Personal Protective Equipment) must match recognized hazards Risk of any hazard event is specific to the individual organization, location, process, equipment, etc. Necessity for self-analysis of hazard and risk analysis Easy decision may not give the best protection for your specific hazard risk True Dual Hazard Risk Worker exposed to both hazards MYTH Higher Arc Flash Rating Equals Increased Fire Protection 6

Introduction Hazard Risk Types OSHA Regulations to Industrial Standards and Test Methods Key U.S. Government Regulations (OSHA) U.S. Code, Title 29 Chapter 15 654 (General Duty) 29 CFR 1910.132 (PPE General Requirements) Industry Standards and Test Methods Tools to comply with OSHA Fire NFPA 2112 (CGSB 155.20) ASTM F 1930 NFPA 2113 (CGSB 155.21) Electric Arc NFPA 70E ASTM F 1506 NESC ASTM F 1959 7

Introduction Hazard Risk Types 8

Overview Industry Standards NFPA 2113: Selection, Care, Use, and Maintenance of Flame-Resistant Garments for Protection of Industrial Personnel Against Short-Duration Thermal Exposures From Fire. Standard Primarily for End-Users OSHA Recognized Tool for 29 CFR 1910.132 Perform Fire / Exposure Hazard Analysis Protective Clothing Selection Meet Minimum NFPA 2112 Specifications Meet Required Protection Identified in Hazard Analysis Based on Specific Work Tasks Wearing / Training Information Care & Maintenance Information Neck, Face, Head, Hand & Foot Coverings PPE Have You Performed a Comprehensive Fire Hazard and Risk Analysis? 9

Overview Industry Standards NFPA 2112: Standard on Flame Resistant Garments for Protection of Industrial Personnel Against Flash Fire Standard Primarily for Manufacturers, not End-Users Provides Minimum Requirements for Design, Construction, Evaluation, and Certification of FR Garments Qualified Garment must exhibit 50% or Less Total Predicted Burn Injury (TPBI) Required Tests (3rd Party Certified) Instrumented Thermal Manikin (ASTM F 1930) Vertical Flammability (New and 100x IL) Heat Transfer Performance (HTP) Thermal Shrinkage Resistance Heat Resistance Sewing Thread Melting 10

Predicted % Survivability Do I Need Dual Hazard Protection? Overview Test Methods 25% Body Burn 50% Body Burn 75% Body Burn 120 100 Chances of surviving a fire decrease 80 Burn Injury 60 Age 40 20 0 20-29 30-39 40-49 50-59 Age Bracket Source: American Burn Association 2011 study 11

Overview Industry Standards NFPA 70E: Standard For Electrical Safety In the Workplace Standard encompasses guidance for making hazard identification and risk assessments PPE and Clothing Selection Assists in complying with OSHA 1910 Subpart S and OSHA 1926 Subpart K Establishes Arc flash boundaries Establishes Arc flash PPE categories Arc PPE categories range from 1 to 4. Arc PPE category is used to determine the necessary arc rating of a garment for a specific job task 12

Arc Flash Protection Boundary Energized Source Flash Protection Boundary Calculated for Each Task Outside Inside 2nd Degree Burn Injury Not Expected FR PPE Not Required Burn Injury Can Occur 2nd+ Degree Burn Injury Predicted FR PPE Required PPE Needs May Differ For Body Parts Arms & Hands 13

Overview Industry Standards NFPA 70E Methods for Arc Flash Clothing Selection Method A [Section 130.5(C)(1) and Annex D, H: Incident energy analysis method Method B [Section 130.7(C)(15)(A)(b) and 130.7(C)(16)]: Arc flash PPE categories method Arc PPE Category 1 2 3 4 Minimum Arc Rating (cal/cm 2 ) 4 8 25 40 Category 1 Category 4 14

Introduction Hazard Risk Types 15

Regulations & Standards Primary Standard Test Methods Overview Test Methods Fire ASTM F-1930 Electric Arc Flash ASTM F-1959 Used to Certify fabrics in NFPA 2112 - Pass / Fail Assessment (6 cal/cm 2 Exposure) ASTM Coverall Pattern Evaluated Average of 3 Exposures Sensors Measure Transmitted Heat - Variable Acquisition Period (ca. 120 s) - Predicted Burn Injury & Probability of Survival Jet Fire Exposure - 2 cal/cm 2 s Heat Flux & Variable Duration Determine Arc Rating of FR System Specimens Tested On Flat Panels Minimum 20 Panels Test Sensors Measure Heat from Arc - Incident Energy of Arc - Energy Transmitted Through Specimen Fixed Fault Current (8 ka) with Adjustable Duration 16

Developed by U.S. Military and DuPont Used to Certify Fabrics in NFPA 2112 Pass / Fail Assessment (6 cal/cm 2 Exposure) Total Predicted Burn Injury (TPBI) must fall below 50% Average of 3 Exposures Sensors Measure Transmitted Heat Collects data for 60 seconds (@ 10 times a second) Predicted Burn Injury & Probability of Survival Jet Fire Exposure Variable Duration & Heat Flux Overview Test Methods Fire - THERMAL MANIKIN TEST (ASTM F 1930) Three Commercial Facilities in N.A. 17

Overview Test Methods Nomex IIIA Untreated Cotton/Poly Untreated Cotton Do You Know What Your Workers Are Wearing? 18

Overview Test Methods Industry misconceptions may influence FR clothing selection The purpose of flame resistant clothing is to only protect workers from Flash Fire hazards All, or most, Flash Fire hazards: Are Short Duration (3 seconds or less) Have the Same Intensity (2 cal/cm 2 s) Intensity Matters 19

Overview Test Methods Question: WHAT ARE TYPICAL INDUSTRIAL FIRES? Answer: THERE ARE NO TYPICAL INDUSTRIAL FIRES. Three (3) Main Variables (Duration X Intensity = Magnitude) Duration (Exposure Time, seconds) - 1 sec to Time to Escape Intensity (Heat Flux) - <1 to >7 cal/cm 2 s Magnitude (Total Exposure Energy) - <1 to >20 cal/cm 2 It is the employer s responsibility to assess the hazard and identify appropriate FR clothing to protect the workers Reference: OSHA 29 CFR 1910.32 Select PPE that will provide a level of protection greater than the minimum required to protect employees from hazards. Reference: OSHA 3151-12R 2003 Question: Have You Fully Assessed Your Exposure to Fire Risk? 20

Determine Arc Rating (cal/cm 2 ) of FR System The Energy Level predicting a 2nd Degree Burn Occurring. Referred to as Arc Thermal Performance Value (ATPV) or the Energy Level to Break-open The Fabric(s) (Ebt) Specimens Tested On Flat Panels Minimum 20 Panels Test Sensors Measure Heat from Arc Incident Energy of Arc Overview - Test Methods ASTM F-1959 Arc Flash Test Method Energy Transmitted Through Specimen 21

Overview Test Methods Non-FR Fabrics Can Ignite and Burn and Melt When Exposed to An Electric Arc Examples: Cotton Wool Polypropylene Polyester Nylon Do You Know What Your Workers Are Wearing? 22

THREATS INSIDE THE ARC FLASH PROTECTION BOUNDARY An arc event presents many types of hazards Intense Radiant Energy > 1.5 cal/cm 2 2nd & 3rd Degree Burns for Unprotected Skin Minimum Ignition Energy for non-fr Clothing Typically Lasts Less Than 1 Second Molten Metal Splatter / Hot Gases / Smoke Secondary Fire (Transformer Oils..) Battery Acids Potential Concussive Forces / Projectiles Damaging Sound Pressure Level 23

Introduction Hazard Risk Types 24

Quick Summary Differentiation Hazard Risk Types Hazards Key End- Users Exposures Temp Limits Exposure Time Key Performance / Attribute Standards Convective Energy Fire Industrial Workers Exposure Time Smoke / Fumes Re-Ignition Potential ~1000 C Seconds NFPA 2112 / 2113 Arc Electricians Utility Workers High Radiant Energy Concussive Forces Smoke / Fumes Molten Metal Splatter ~6000 ºC << 1 sec NFPA 70E / NESC 25

Quick Summary Differentiation Hazard Risk Types NFPA 2112 - ASTM F-1930 NFPA 70e ASTM F-1959 Finished Garment Subjected to Jet Fire Engulfment Fireball 2 cal/cm 2 s Heat Flux at 3 seconds duration 6 cal/cm 2 total Energy Exposure TPBI Total Predicted Body Injury Minimum Performance Standard Pass/Fail Garment Must Not Exhibit > 50% TPBI Fabric Sample Subjected to Arc Flash < 1 second Arc of Intense Energy > 1.5 cal/cm 2 ATPV Arc Thermal Performance Value EBT Energy Break Open Threshold Energy that results in second degree burns or break open Does Not Predict a TPBI 26

Introduction Hazard Risk Types 27

Garment Evaluations NOMEX IIIA - 6 oz/yd 2 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 10.7% Predicted Body Burn Injury 88/12 FR Treated Cotton / Nylon 7 oz/yd 2 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 15.6% Predicted Body Burn Injury 28

NOMEX IIIA, 6 oz/yd 2 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 Predicted Burn Injury: 10.7% 88/12 FR Treated Cotton / Nylon, 7 oz/yd 2 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 Predicted Burn Injury: 15.6%

NOMEX IIIA, 6 oz/yd 2 Predicted Burn Injury Survivability Test Data 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 Predicted Burn Injury: 10.7% 88/12 FR Treated Cotton / Nylon, 7 oz/yd 2 3 seconds @ 2.0 cal/cm 2 s Total Exposure: 6.0 cal/cm 2 Predicted Burn Injury: 15.6%

DURATION AND PREDICTED BODY BURN INJURY % Garment Evaluations NOMEX IIIA - 6 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 34.4% Predicted Body Burn Injury 88/12 FR Treated Cotton / Nylon 7 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 69.7% Predicted Body Burn Injury 31

NOMEX IIIA, 6 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 Predicted Burn Injury: 34.4% 88/12 FR Treated Cotton / Nylon, 7 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 Predicted Burn Injury: 69.7%

NOMEX IIIA, 6 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 Predicted Burn Injury: 34.4% Predicted Burn Injury Survivability Test Data 88/12 FR Treated Cotton / Nylon, 7 oz/yd 2 4 seconds @ 2.0 cal/cm 2 s Total Exposure: 8.0 cal/cm 2 Predicted Burn Injury: 69.7%

TPBI % Do I Need Dual Hazard Protection? 80.00% Garment Evaluations Thermo-Man ASTM F-1930 Comparison 70.00% 60.00% 69.70% 50.00% 40.00% 30.00% 34.40% 20.00% 10.00% 10.70% 15.60% Arc Flash 0.00% Nomex IIIA 6 oz 88/12 FRT Cotton Nylon 7 oz PPE Category 1 PPE Category 2 ASTM F-1930 2.0 Cal/cm2-3s ASTM F-1930 2.0 Cal/cm2-4s 34

Garment Evaluations Is Your Current PPE Program The BEST Fit For Your Risk Assessment? Are your current PPE choices the BEST fit for your risk assessment? There are true Dual Hazard Protection PPE choices Engineered blends available that demonstrate protection for both hazard types. Chose the solution that best fits your assessment needs Cannot Infer short duration fire performance based on ATPV or electrical arc categories, and vice vs 35

36

Summation - Takeaways Have You Fully Assessed Your Hazard Risks? NFPA 2112 Short Duration Fires Intensity Matters Heat Flux vs. Duration NFPA 70e Arc Flash Are All Your Employees at Risk? Proper worker PPE must match recognized hazards within the individual organization and equipment utilized Necessity for self-analysis of risk assessment Consider the tradeoffs of protection not needed. 37

Summation - Takeaways Is Your Current PPE Program Optimized For All Important Characteristics? Hazard Risk NFPA 2112 Short Duration Fires NFPA 70E Arc Flash Wearer Comfort Durability Flame Resistant Properties Wear Properties and Wear Life Cost Considerations Initial Cost vs. Total Life Cycle Cost Ease of Care and Long Term Appearance 38

39

40