TEHNIAL MANUAL AL MBV Blowers efer to Service Manual S0000 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual. efer to the appropriate Parts atalog for part number information. Models listed on page. This manual is to be used by qualified, professionally trained HVA technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. T00 September 00 opyright 00 Goodman Manufacturing ompany, L.P.
PODUT IDENTIFIATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. MBV00AA-AA MBV00AA-AA MBV000AA-AA MB V 00 A A DESIGN SEIES: MB: Modular Blower FATOY HEAT: 00: No Heat DESIGN SEIES: A: First Series MOTO TYPE: V: Variable Speed OMMUNIATION FEATUE: : -wire ommunication eady AILOW DELIVEED: : 00 FM : 00 FM 0: 000 FM IUIT BEAKE: A: No ircuit Breaker B: ircuit Breaker ELETIAL SUPPLY: : 0-0V/0HZ/ phase WANING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. WANING Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WANING Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician" as specified by the Air-onditioning, Heating, and efrigeration Institute (AHI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WANING The United States Environmental Protection Agency ( EPA ) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. WANING Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WANING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.
PODUT DESIGN GENEAL INFOMATION The MBV Blower abinets are used in combination with a cased evaporator coil for a two-piece blower and coil combination. This combination of blower and coil functions as the indoor part of a split air-conditioning system, and may be matched with a remote condensing or heat pump unit and allows for a variety of mix-matching possibilities. The blower cabinet can also function as an electric furnace when used with an electric heater. NOTE: The electric heating elements for electric furnace installation are not shipped with the cabinet and are fieldinstalled. Electric heater kits (HK) are available as sales accessories for supplemental electric heat. Systems should be properly sized by heat gain and loss calculations made according to methods of the Air onditioning ontractors Association (AA) or equivalent. It is the contractor s responsibility to ensure the system has adequate capacity to heat or cool the conditioned space. The MBV blower cabinet uses a variable speed motor that maintains a constant airflow with a higher duct static. It is approved for applications with cooling coils of up to 0. inches W.. external static pressure and includes a feature that allows airflow to be changed to + 0%. The MBV blower cabinets, with proper coil matches, can be positioned for upflow, counterflow, horizontal right or horizontal left operation. All units are constructed with -. insulation. In areas of extreme humidity (greater than 0% consistently), insulate the exterior of the blower with insulation having a vapor barrier equivalent to ductwork insulation, providing local codes permit. The APX/HPX coils are equipped with a thermostatic expansion valve that has a built-in internal check valve for refrigerant metering. The AF/APF/HPF coils are equipped with a fixed restrictor orifice. The coils are designed for upflow, counterflow, or horizontal application, using EM motors on the MBV models. FEATUES This modular blower is a part of the omfortnet family of products. It may be installed as part of a legacy system using a standard VA thermostat. However, with the TK0AA omfortnet thermostat kit, this modular blower may be installed as part of a digitally communicating system. The omfortnet system provides automatic airflow configuration, enhanced setup features, and enhanced diagnostics. It also reduces the number of thermostat wires to a maximum of four. OMFOTNET SYSTEM OVEVIEW The omfortnet system (or T system) is a system that includes a omfortnet compatible modular blower and air conditioner or heat pump with a TK0AA thermostat. Any other system configurations are considered invalid omfortnet systems and must be connected as a traditional (or legacy) system. The table below compares the valid T systems. T compatible Modular Blower T compatible Modular Blower T compatible Air onditioner T compatible Heat Pump Full T system benefits & features Full T system benefits & features A omfortnet heating/air conditioning system differs from a legacy/traditional system in the manner in which the indoor unit, outdoor unit and thermostat interact with one another. In a traditional system, the thermostat sends commands to the indoor and outdoor units via analog VA signals. It is a one-way communication path in that the indoor and outdoor units typically do not return information to the thermostat. On the other hand, the indoor unit, outdoor unit, and thermostat comprising a omfortnet system communicate digitally with one another. It is now a two-way communications path. The thermostat still sends commands to the indoor and outdoor units. However, the thermostat may also request and receive information from both the indoor and outdoor units. This information may be displayed on the T thermostat. The indoor and outdoor units also interact with one another. The outdoor unit may send commands to or request information from the indoor unit. This two-way digital communications between the thermostat and subsystems (indoor/outdoor unit) and between subsystems is the key to unlocking the benefits and features of the omfortnet system. Two-way digital communications is accomplished using only two wires. The thermostat and subsystem controls are powered with VA Thus, a maximum of wires between the equipment and thermostat is all that is required to operate the system.
MBV OWE SPEIFIATIONS D / / () KNOKOUTS...0. KNOKOUT ( PLAES) H / W MBV00/00/000 MODEL Blower Wheel (D x W) Physical Information Blower Motor (HP) MBV00 0X /. MBV00 0X /. MBV000 X0 /. Dimensions, inches (mm) MA MOP W H D ½ () () ½ () (0) 0 () 0 () () () () Shipping Weight lbs.(kg) (.) (.) (.) Minimum ircuit Ampacity (MA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. efer to unit nameplate for MA and MOP with approved accessory heaters installed.
MBV OWE SPEIFIATIONS OWE OPENING DIMENSIONS (TOP VIEW) 0-/ -/ 0-/ -/ -/ 0-/ -/ -/ SMALL MEDIUM LAGE MBV00/00/000 HK HEATE DATA OWE HEATE KIT NO HEAT KIT HK-0* HK0-()* HK-0* HK-0()* MBV 00AA-AA X X X X X 00AA-AA X X X X X 000AA-AA X X X X X ^ = ircuit : Single Phase for Air Handler Motor * = evision level that my or may not be designated ircuit : -Phase for HK Heater Kits = ircuit Breaker option X = Allowable combinations ~ = estricted combinations OWE HEATE KIT HK-0()* HK-* HK-0* HK-* MBV 00AA-AA X X ~ ~ 00AA-AA X X ~ ~ 000AA-AA X X X ~ ^ = ircuit : Single Phase for Air Handler Motor * = evision level that my or may not be desig ircuit : -Phase for HK Heater Kits = ircuit Breaker option X = Allowable combinations ~ = estricted combinations
OWE PEFOMANE DATA HT kw MBV00* MBV00* MBV000* SWITH SWITH 0 SWITH 00 00 00 ON ON ON 00 00 00 ON ON OFF 00 00 ON OFF ON 0 000 000 ON OFF OFF 0 000 000 00 OFF ON ON 00 00 00 OFF ON OFF 0 N N 000 OFF OFF ON N N N ON^ ON^ ON^ ^ Factory setting MODEL MBV00 MBV00 MBV000 LOW STAGE OOL HIGH STAGE OOL OOL SELETION SWITHES ADJUST SELETION SWITHES POFILE SELETION SWITHES 00 00 OFF OFF OFF OFF OFF OFF 0 00 ON OFF ON OFF ON OFF 0 000 OFF ON OFF ON OFF ON 00 00 ON ON ON ON ON ON 0 000 OFF OFF OFF OFF OFF OFF 00 00 ON OFF ON OFF ON OFF 0 00 OFF ON OFF ON OFF ON 00 00 ON ON ON ON ON ON 00 00 OFF OFF OFF OFF OFF OFF 00 00 ON OFF ON OFF ON OFF 00 00 OFF ON OFF ON OFF ON 0 000 ON ON ON ON ON ON Locate the blower speed selection DIP switches on the integrated control module. Select the desired cooling speed tap by positioning switches and appropriately. Select the desired adjust tap by positioning switches and appropriately. efer to the following figure for switch positions and their corresponding taps. Verify FM by counting the number of times the green FM LED blinks. Normal* +0% -0% Normal OFF ON OFF ON OFF ON OFF ON Air flow Adjust Taps (*indicates factory setting) Thermostat "Fan Only" Mode During "Fan Only" operations, the FM output is 0% of the maximum FM capability. FM Trim Adjust Minor adjustments can be made through the dipswitch combination of -.
WIING DIAGAMS THEMOSTATS HIGH VOLTAGE! DISONNET ALL POWE BEFOE SEVIING O INSTALLING THIS UNIT. MULTIPLE POWE SOUES MAY BE PESENT. FAILUE TO DO SO MAY AUSE POPETY DAMAGE, PESONAL INJUY O DEATH. G W W Y Y Typical Two-Stage ool, Two-Stage Heat Thermostat G W W Y Y O DEHUM Modular Blower Integrated ontrol Module * Y Y emote ondensing Unit (Two-Stage A) NEU HOT Dehumidistat [Optional] Typical Two-Stage ooling with Two-Stage Heating G EM W O Y Y Typical Two-Stage ool, Two-Stage Heat Heat Pump Thermostat G W W Y Y O DEHUM * Modular Blower Integrated ontrol Module W Y Y emote ondensing Unit (Two-Stage HP) O NEU HOT Dehumidistat [Optional] Typical Two Stage Heat Pump heating and Auxiliary/Emergency Heating Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
- WIING DIAGAMS HIGH VOLTAGE! DISONNET ALL POWE BEFOE SEVIING O INSTALLING THIS UNIT. MULTIPLE POWE SOUES MAY BE PESENT. FAILUE TO DO SO MAY AUSE POPETY DAMAGE, PESONAL INJUY O DEATH. HT TL M M PU PLM HT TL HT TL M M M M PU PLM HT TL HT TL HT TL PU M M M M M M PLM B HT TL HT TL HT TL HT TL PU M M M M M M M M B PLM L L ONE () ELEMENT OWS L L TWO () ELEMENT OWS L L L L THEE () ELEMENT OWS FOU () ELEMENT OWS L L L L NOTE: EN INSTALLING HEATE KIT, ENSUE SPEED TAP DOES NOT EXEED MINIMUM OWE SPEED (MBS) SPEIFIED FO THE AIHANDLE/HEATE KIT OMBINATION ON THIS UNIT'S S& PLATE. AFTE INSTALLING OPTIONAL HEAT KIT, MAK AN "X" IN THE POVIDED ABOVE. MAK AOING TO NUMBE OF HEATE ELEMENT OWS INSTALLED. NO MAK INDIATES NO HEAT KIT INSTALLED. B K D PL PL SEE NOTE 0 VA TANSFOME, SEE NOTE 0 VA GND 0 VA VA OM B LEAN FM LED OOL SEE NOTE ADJUST DELAY BIAS DEHUM UNUSED ELE HEAT AF BIAS TEM SEE NOTE GN TH T OM FUSE V A DEHUM O Y Y DIP SWITHES W EM MOTO HANESS IUIT HEATE ONNETO DIAGNOSTI LED STATUS LED X LED W TWO-STAGE INTEGATED ONTOL MODULE G TX () GY G IULATO OWE V THEMOSTAT ONNETIONS V THEMOSTAT ONNETIONS W W Y Y O DISONNET L FUSE A TO MIO W () +VD () X () HEAT SEQUENE GND DEHUM GND () GN T OM INTEGATED ONTOL MODULE L TH W () GND INDOO AI IULATO W 0/0 VA VA L GND 0 VA TANSFOME HEAT SEQUENE L INDOO AI IULATO W GND NOTES:. PLAE ED WIE ON TANSFOME TEMINAL FO 0 VA OPEATION.. MANUFATUE'S SPEIFIED EPLAEMENT PATS MUST BE USED EN SEVIING.. IF ANY OF THE OIGINAL WIE AS SUPPLIED WITH THE OWE MUST BE EPLAED, IT MUST BE EPLAED WITH WIING MATEIAL HAVING A TEMPEATUE ATING OF AT LEAST 0. USE OPPE ONDUTOS ONLY.. UNIT MUST BE PEMANENTLY GOUNDED AND ONFOM TO N.E.. AND LOAL ODES.. TO EALL THE LAST FAULTS, MOST EENT TO LEAST EENT, DEPESS SWITH FO MOE THAN SEONDS ILE IN STANDBY (N THEMOSTAT INPUTS).. BIAS AND TEM DIPSWITHES MUST BE IN "ON" POSITION. ED STATUS LED POVIDES NETWOK STATUS. GEEN X LED INDIATES NETWOK TAFFI. USE LEAN BUTTON TO ESET NETWOK.. DISA ONNETO PL EN INSTALLING OPTIONAL HEAT KIT. 00A000 EV. A OLO ODES: PK PINK B BOWN ITE UE GY GAY ED YELLOW O OANGE VT VIOLET GN GEEN AK LOW VOLTAGE (V) LOW VOLTAGE FIELD HI VOLTAGE (0V) HI VOLTAGE FIELD JUNTION TEMINAL INTENAL TO INTEGATED ONTOL EQUIPMENT GND FIELD GND FIELD SPLIE ESISTE OVEUENT POT. DEVIE PLUG ONNETION Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.