Refrigerant Glide and Effect on Performances Declaration

Similar documents
Refrigerants and lubricants

Pressure Enthalpy Charts

BRA FACT FINDER Number 19

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Low GWP Refrigerants for Air Conditioning Applications

2016 Annual Conference

Low Global Warming Refrigerants For Commercial Refrigeration Systems

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Technical Note. EHPA Quality Label Model Range Definition Version

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

(Refer Slide Time: 00:00:40 min)

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

R-407A R-448A R-449A

Modeling and Testing of an R-23/R-134a Mixed Refrigerant System for Low Temperature Refrigeration

REFRIGERANT CHANGEOVER

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

HVAC Fundamentals & Refrigeration Cycle

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

CHAPTER 1 INTRODUCTION

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

System Considerations for Refrigerant Blends with Temperature Glide

Designing evaporators and condensers for refrigerant mixtures with high temperature

A Comparison Between Refrigerants Used In Air Conditioning

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Negative Superheat? Time to Check Your Tools

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

The Refrigeration Cycle

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

The Refrigeration Cycle

Embraco Position Paper: Light Commercial Refrigeration

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

System Design, Commissioning, Operation

The Essentials Of Working With R-410A

Refrigeration Systems

ISSN Vol.08,Issue.21, November-2016, Pages:

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Enhancement of COP in Vapour Compression Refrigeration System

DOE and EPA Impacts to Commercial Refrigeration

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

January 16 th, 2014 New York City

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

II. OBJECTIVE OF RESEARCH

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Technical Bulletin (TB-0037)

Fundamentals of Refrigeration Part 2 Refrigeration 1

Air-Cooled Heat Exchanger Performance for R410A

AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Chapter 2. Alternatives to HCFCs and their Characteristics

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Week 9. Refrigeration Cycles I. GENESYS Laboratory

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Performance Assessment of Three Eco-Friendly Hydro-Fluorocarbon and Hydrocarbon Refrigerant Mixtures as R22 Alternatives in Refrigeration Systems

Study of R161 Refrigerant for Residential Airconditioning

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

TEST REPORT #6. Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP)

ADVANCES in NATURAL and APPLIED SCIENCES

Technical Information

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Technical Information

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Comparative Performance of HFO Blends in a Condenser

Oyelami S., Bolaji B. O.

Transcription:

Refrigerant Glide and Effect on Performances Declaration Scope and Purpose As a consequence of the EU regulation 517/2014 (F-gas), the future synthetic refrigerants with a low global warming potential will be to a large degree nonazeotropic mixtures with a significant temperature glide (some over 6 K). These refrigerants change temperature during the evaporating and condensing process at constant pressure. Many works comparing the performances of different refrigerants have been published referring to mid-point temperature where no evident correlation between mid-point and pressure can be easily determined. The scope of this guideline is to give an overview of the relation between the dew and mid temperature for non-azeotropic mixtures, highlight the difference in performance and give a recommendation for converting the performance of the compressor regulated by the existing standards to mid-temperature performance. In this case, any misunderstanding and wrong interpretations of the result are avoided. 1. Refrigerant Mixtures Classification Refrigerant blends are mixtures of two (binary) or more pure refrigerant fluids. The refrigerant mixtures can be divided into: 1. Azeotropic refrigerant mixtures 2. Near-azeotropic refrigerant mixtures 3. Non-azeotropic refrigerant mixtures, also known as zeotropic mixtures Near-azeotropic mixtures are mixtures with small temperature variation during phase change and a small difference in composition in liquid and vapour phases at equilibrium. The widely used refrigerants R404A and R410A belong to this class. a) Azeotropic Mixtures The azeotropic (refrigerant) mixtures are usually binary mixtures that behave like a pure fluid, i.e., under constant pressure they condense and evaporate at a constant temperature and the composition of the mixture in the vapour and liquid phases are considered to be the same. In a refrigeration cycle represented in a p-h diagram (figure 1), the compressor raises the pressures from the evaporating to the condensing pressure. Evaporation and condensation happen at constant pressure during the process change. A single temperature defines either the evaporation or the condensing pressure. 1 / 11

Pressure [kpa] t 2d p 2 t 2d 2 t 1d t 1 p 1 t 1d 1 Enthalpy [kj/kg] Figure 1: p h diagram for azeotropic mixture evaporating pressure: p 1 (t 1d ), condensing pressure: p 2 (t 2d ) b) Non-Azeotropic Mixtures Non-azeotropic (refrigerant) mixtures, also known as zeotropic mixtures, exhibit a significant temperature variation during constant pressure phase change, such as condensation and evaporation. Also, at equilibrium the composition in vapour and liquid phases will be different. The term "glide" is widely used to describe the temperature change during the evaporation and condensation process. Figure 2 shows a p-h diagram representing the refrigeration cycle with a nonazeotropic mixture. The condensing pressure p2 and evaporating pressure p1 are considered to be constant throughout the change of state process. The lines of constant temperature are sloping, as illustrated in the figure. The temperature at which condensation starts is called the dew point, denoted here as t2d. As condensation progresses, the temperature falls to t2f (bubble point). During the evaporation process, the temperature changes from the temperature at the inlet of the evaporator t1e to the dew point temperature t1d. Superheat occurs after evaporation is complete, raising the temperature to t1 (suction temperature at the compressor inlet). Compressors are rated according to this cycle, with the evaporating and condensing pressures expressed as dew point temperatures. 2 / 11

Pressure [kpa] t 2m p 2 2 f 2 d 2 t 1 t 2d t 1m t t 2m 2f p 1 1e 1 d 1 t 1d t 1m t 1e Enthalpy [kj/kg] Figure 2: p-h diagram for non-azeotropic mixture The question then arises as to which temperature along each change of state process should be used to define the evaporating and condensing temperatures. A mean temperature may be defined for purposes of analysis to represent the actual system performance or for comparing blends with pure refrigerants. Compressor standards agree for using dew point temperatures because they allow for a clear correlation between pressures and temperatures. 2. Performances Declaration a) Dew Point Protocol The evaporating and condensing temperatures are defined as the dew temperatures t1d and t2d as reported in figure 2. A single temperature now defines the compressor inlet (evaporation) pressure and it is independent of the condensation process. The definition of superheat is easily calculated as the difference between compressor suction temperature and evaporating temperature. The liquid sub-cooling is however still calculated with respect to the bubble point. 3 / 11

b) Mid-point Protocol The condensing temperature could be defined as the arithmetic mean of dew t2d and bubble temperatures t2f, and the evaporating temperature is likewise defined as the arithmetic mean of t1e and t1d. For condensing, at given discharge pressure the dew temperature t2d and the bubble temperature t2f are fixed, hence the mid temperature is only pressure dependent. Therefore, reference can be easily made for the mid temperature: t2m = (t2f + t2d) / 2. The average evaporating temperature t1m is the average temperature between the inlet temperature in the evaporator t1e and saturated vapour temperature t1d: t1m = (t1e + t1d) / 2. The evaporator inlet temperature, and hence mid evaporating temperature, changes with the condensing pressure as illustrated in Figure 3. Similarly, the mid evaporating temperature is also dependent on the extent of sub-cooling. Measurement of the evaporating pressure is thus no longer sufficient to define the mid evaporating temperature and t1e is expressed as function of the evaporating pressure, the condensing pressure and the sub-cooling t1e = f(p1, p2, sub-cooling). Superheat definition can also be misinterpreted when using mid-point data. Superheat is the difference between the temperature at the compressor suction inlet, t1 and the (dew point) temperature at the end of the evaporation process, t1d. When the evaporating temperature is defined as mid-point, the dew point temperature has to be calculated before the superheat can be found t1d = t1e + 2(t1m t1e). Obviously, the lack of correlation between the evaporating temperature and the evaporating pressure renders this approach somewhat difficult. Hence, it is obvious that any performance related to mid-point temperature could create a misunderstanding if insufficient information is given. 4 / 11

Pressure [kpa] 3.6 p 2 Sub-Cooling Increase 2 f 2 p' 2 3 Discharge Pressure Decrease 2' t 1e p 1 2.4 Shift in t 1e (inlet evap) due to pressure or sub-cooling Enthalpy [kj/kg] 1 Figure 3: Effect of condensing pressure or the sub-cooling on evaporating mid-temperature When an economizer cycle is applied (Fig. 4), the mid-temperature t 1m depends on the outlet temperature t10 of the economizer liquid sub-cooler. Hence, the midtemperature is changing with the sub-cooling at the same evaporating and condensing pressure. Thus, referring to mid-temperature introduces a further complication for economizer application. 5 / 11

Pressure [kpa] 3.6 p 2 Sub-Cooling at (Economizer.) 10 2 f 2 3.2 p 7 7 2.8 p 1 t' 1m t 1m 1 2.4 Enthalpy [kj/kg] c) Compressor Performances Figure 4: Effect of the Economizer outlet temperature on Evaporating mid-point temperature The compressor s performances declaration in Europe and North America are regulated respectively according to the standard EN 12900 and to ARI 540. The declared performance according to these standards shall comprise the refrigerating capacity or mass flow and the absorbed power, at dew points evaporating and condensing temperatures. The polynomial equation reported below is used either by EN 12900 as well by ARI 540 to generate the performances of the compressor: X = C1 +C2 (S) + C3 D +C4 (S 2 ) + C5 (S D) + C6 (D 2 ) + C7 (S 3 ) + C8 (D S 2 ) +C9 (S D 2 ) + C10 (D 3 ) where: X is the refrigerating capacity (only EN 12900), absorbed power or mass flow, current S is the evaporating temperature at suction dew point D is the condensing temperature at discharge dew point, C is a coefficient. 2) Performance Comparison 6 / 11

t mid - t d [K] Figure 5 shows an example of the difference between the mid and dew temperatures for R407C. It proofs how the condensing temperature affects the mid evaporating temperature. The 2 lines are calculated at constant dew evaporating temperature. Mid Temperature Variation with Condensing Temperature Refrigerant : R407C -1.0-1.5-35 C -10 C -2.0-2.5-3.0-3.5-4.0 0 10 20 30 40 50 60 70 Condensing temperature: t 2d [ C] Figure 5: Mid vs. Dew evaporating temperature at various condensing pressure Figure 6 illustrates the performance variation using the two approaches for a typical reciprocating or scroll compressor at -10 C evaporating and 45 C condensing temperatures. It can be seen that the capacity is lower by approximately 5 % for dew temperature reference with no appreciable difference in the COP. The system designer may properly interpret the data from the appropriate definition, but a casual observer may conclude that the compressor delivers less capacity when dew point definitions are used, although this is not the case. 7 / 11

Cooling Capacity Variation 10% Cooling Capacity (Mid vs. Dew) 0K Subcooling 8% 6% 4% 2% 4.7% 5.6% 5.6% 0% 5/50 /15 C -10/45/20 C -10/45/0 C Figure 6: Reciprocating and Scroll Compressor performance variations according to dew and mid temperatures 8 / 11

Pressure [kpa] Recommendations of using Mid-point temperature This is a recommended method to convert dew (point) temperatures to mid-point temperatures. It allows comparing compressor performance data for different refrigerants. Condensing mid temperature: t2m = (t2f + t2d) / 2 Sub-cooling: Dtsub = t2f t5 Evaporating mid temperature: t1m = ( t1e + t1d) / 2 Gas Superheat at the compressor inlet tsh = (t1 t1d) The above temperature conversion provides more than a rough comparison of compressor performance data. p 2 5 2 f 2m 2 d 2 t 1 t 2d t 2m t 2f p 1 1e 1m 1 d 1 t 1d t 1m t 1e Enthalpy [kj/kg] Nomenclature 1 : compressor inlet 2 : compressor outlet d: dew m: mid f: fluid 2f: liquid refrigerant at bubble point corresponding to the compressor discharge pressure 9 / 11

5: refrigerant fluid at the inlet of the expansion device 7: intermediate pressure (economizer) 10: liquid outlet of the economizer t1: refrigerant gas temperature at the inlet of the compressor t1d: dew point temperature at suction pressure t2d: dew point temperature at discharge pressure t1m: mid-point temperature at suction pressure t2m: mid-point temperature at discharge pressure t1e: refrigerant temperature inlet at the evaporator Example mid-point: R407C // -10/45/SH after evap. 5 K total 20 K/SC inside condenser 2 K Example dew point: R407C // -10/45/SH after evap. 5 K total 20 K/SC inside condenser 2 K 10 / 11

Reference EN 12900:2013 - Refrigerant compressors Rating conditions, tolerances and presentation of manufacturer s performance data EN13771-1: 2003- Compressors and condensing units for refrigeration - Performance testing and test methods Part 1: Refrigerant compressors ARI standard 540: 2004 Performance rating of positive displacement refrigerant compressors and compressor units These recommendations are addressed to professionals, industrial, commercial and domestic refrigeration system manufacturers / installers. They have been drafted on the basis of what ASERCOM believes to be the state of scientific and technical knowledge at the time of drafting, however, ASERCOM and its member companies cannot accept any responsibility for and, in particular, cannot assume any reliability with respect to any measures - acts or omissions - taken on the basis of these recommendations. 11 / 11