CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Similar documents
Unvented Electric Water Heater 10/15 litre Undersink

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Powerflow Unvented water heater

Installation and User Instructions HS10U, HS15U.

INSTANTANEOUS ELECTRIC SHOWER

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented water heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

HOTFLO 10 / 15. Fitting Instructions and User Guide

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

Unvented water heater

ZIP VARIPOINT II Direct unvented water heaters.

Quantum. Installation, User and Service Manual. Hot Spring

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

MULTIPOINT 30 & 50 Litre

Alpha CombiMax 350 and 600

SEALED THERMAL STORE

Bath Shower Mixer

Oltis thermostatic bar mixer

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Dene Bath Shower Mixer

Installation, Operating and Maintenance Guide

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Dove Eco thermostatic bar mixer shower

Sema thermostatic bar mixer Installation and operating instructions

HOTFLO 10 / 15. Fitting Instructions and User Guide

Instructions for Use Installation and Servicing

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Multipoint Technical Data

MULTIPOINT SS H 50/80 & 100

Thermostatic Concealed Shower Valve

Unvented Direct & Indirect Hot Water Cylinders (400L L)

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Thermostatic bar mixer shower. Installation and Operating Instructions. Installers please note these instructions are to be left with the user

RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions

HW3 Handwash Installation and Operating Instructions

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

USER INSTRUCTION MANUAL. Autofill Water Boiler

MEGAFLO HE Iss 1

Technical and Installation manual All Models

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Thames thermostatic bar mixer with diverter Installation and operating instructions

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Autofill counter top water boiler

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Schuco SS-TC/SC Cylinders

Installation & User Instructions

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Installation and Commissioning Manual

TH100 Three in One Instant Hot Water Tap

User's Instructions. Alpha CB50

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Thermostatic Shower Tower Installation and Operating Instructions

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower. Installers please note these instructions are to be left with the user

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

POWER SHOWERS Models 4500M 5002M 4500T 5002T

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Streamline Undersink. Fitting Instructions and User Guide

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

Installation, operating and servicing instructions

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Mimosa dual control mixer shower Installation and operating instructions

Alcor dual control mixer shower

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Leona thermostatic bar mixer shower pole Installation and operating instructions

Installation, Operating and Maintenance Guide

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

Unvented water heating

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Transcription:

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1

DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm 370mm Model CPU10/CPOS10 CPU15/CPOS15 Nominal Capacity Litres 10 15 Height / Width / Depth - mm 410 x 370 x 250 410 x 370 x 310 Power - kw 2 2 Voltage v 240 240 Heat Up Time Δt = 50ºC - mins 17 26 Maximum Operating Pressure - Bar 6 6 Insulation mm 19 19 Switch On / Off Yes Yes Adjustable Thermostat Yes Yes Magnesium Anode Yes Yes Safety Valve ½ x 6 Bar ½ x 6 Bar Net Weight kg 6.50 8.50 Pipe Connections BSP ½ ½ 2

INSTALLATION General The Crown undersink water heater is manufactured to a very high quality and provides a glasslined steel water cylinder for long lasting and hygienic supply of hot water direct to one or more water outlets. The water may be stored at a high temperature (>68 C) to avoid bacterial build up and mixed down using either the optional mixer valve or a mixer tap, to provide higher volumes of lower temperature/hand-hot water. Contents Crown Compact Rapid Flow Water Heater Use and Installation Guide 6Bar Expansion Relief Valve Wall Mounting Hooks Insulating Pipework Adapters and Washers Foot Pads (Under Sink Only) Important Information Please read these instructions prior to installing your water heater Do not operate the unit if you suspect that it is frozen If water is seen discharging from the safety valve, the unit should be switched off from the mains electricity supply immediately and contact Crown Water Heaters Ltd on 01902 310678 The water stored within the unit may be set to high temperatures. For handwash purposes the thermostat may be fixed to a mid-range temperature or supplied via a mixer valve. WARNING THIS APPLIANCE MUST BE EARTHED This appliance is supplied with a pre-wired electric cable. If the supply cable becomes damaged, it must be replaced by a qualified electrician. The water heater MUST be fitted with the expansion relief valve supplied. The safety valve must not be plugged, removed or replaced with any other device. Only genuine Crown accessories should be used with the water heater. The Crown guarantee will be invalidated and the installation may fail to operate correctly or could be dangerous should other components be used. The unit is not fitted with a drain plug. To empty the water from the unit, the unit should be disconnected from the mains water and electricity supplies and removed from its location. See the Maintenance section for safe removal of the unit. The unit is designed to be fitted directly to the cold mains water supply. 3

Technical Specifications Cylinder Capacity Electrical Rating Power Glass-Lined Mild Steel 10 or 15 Litres 230/240V 50Hz Single Phase 2kw Weight Full Empty 10 Litre 16.5kg 6.5kg 15 Litre 23.5kg 8.5kg Maximum Rated Pressure Minimum Supply Pressure 6 Bar 0.8 Bar at low supply pressures the performance of the unit will be reduced. Configurations Mains Water Pressure greater than 4bar Both the expansion and pressure reducing kits (purchased separately) must be installed In some cases mains water pressure is not constant and can increase at times of low demand, i.e. night time and weekends Mains Water Pressure less than 4bar Installation options as per table below Cold water take-off beyond minimum distances (see installation requirements) Cold water take-off within minimum distances (see installation requirements) Non-return valve or similar function in mains water supply Expansion kit required Expansion kit required No non-return valve or similar function in mains water supply No additional kits required Expansion kit required Installation Requirements Standard unit as supplies allows expansion back into the mains under the following conditions: Static mains water supply pressure must be continuously at 4bar or lower The nearest cold water take-off must be at least: - 2.8m from the 10 litre unit - 4.2m from the 15 litre unit There should be no non-return function or device in the mains water supply e.g. water meter or stop cock 4

Where these parameters cannot be satisfied the following kits should be installed a) Expansion Kit A (Purchased Separately) 2L Expansion Vessel Non Return Valve b) Pressure Reducing Kit B (Purchased Separately) Pressure Reducing Valve with Gauge For all installations where the static mains water supply exceeds 4bar. Note: the use of a pressure reducing valve will require the installation of an expansion kit above. Location The unit is designed to be mounted near to the point of use. Where the unit is to provide water to a bathroom area, the unit should be mounted so as to conform to the wiring regulations for bathroom areas. The unit should be wall mounted vertically with the inlet and outlet pipes at the top of the unit. Care should be taken to mount the unit so that water cannot be splashed or dripped onto the unit. If the undersink water heater is to be floor standing, fit the two adhesive rubber pads provided to the bottom front edge 100mm apart. Sufficient space should be allowed around the unit to provide access for servicing and maintenance. The mounting surface should be sufficiently strong to carry the weight of the unit when full of water see technical specification. The unit may stand on the floor of the undersink cabinet to assist with the weight handling, but the unit should also be fixed to the wall. The unit must not be installed in a location where it is likely to encounter excessively low temperatures that may cause the unit to freeze. The undersink water heater is to be fitted with a tundish and discharge pipe. The discharge pipe must be installed in a continuous downward slope and should terminate in a safe place with the end left open to the atmosphere. The unit should be sited to allow for suitable routing and termination of the discharge pipe. Sufficient room should be allowed for the mounting of any additional expansion or pressure reducing kit that may be required, The cold water inlet of the unit is marked with a blue collar and should be connected to the mains water supply, the hot water outlet is marked with a red collar. Plumbing The unit should be plumbed into position prior to connecting to the electrical supply. The unit is designed for connection to the cold mains water supply. Install a service valve in the mains water supply to allow the unit to be isolated from the mains water supply in case of servicing or fault. 5

It is recommended that the water heater is fitted with a check valve and expansion vessel (Crown Expansion Kit A ). However, expansion may be accommodated directly in the cold water supply pipe work. See Configurations. Do not use plumber s compound as this could prevent correct operation of the safety valves and will invalidate the warranty. Having located the site in which the unit is to be mounted, mark the position of the holes through the mounting bracket. Ensuring there are no pipes, cables or other services within the wall to be drilled. MAINS WATER SUPPLY Pressure Reducing Valve If a pressure reducing valve is required, a Crown Kit B should be fitted to the mains water supply pipe, making sure that the directions indicator on the side of the valve points in the direction of the water flow. If installing a pressure reducing valve, the Crown Expansion Kit A must also be installed. Expansion Vessel Where an expansion vessel is required, this must be fitted using a T-piece in the cold water supply on the water heater side of the check valve. See Connection diagram. The expansion vessel should be charged to 3.5Bar when cold. This should be checked prior to installation using a pressure gauge and topped-up using a foot or hand pump. Expansion Relief Valve It is a statutory requirement that an expansion relief valve is fitted to the cold water supply just before the cold water inlet via a T-compression joint and that outlet of this valve be taken to the 15mm discharge pipe. 6

Hot Water Outlet The hot water outlet (marked red) should be routed directly to an ordinary tap at the point(s) of use. Note there is no requirement for a special vented tap for use with this unit. Mixer Valve Where the temperature of the water at the tap is required to be controlled to a specific temperature, a mixer valve may be incorporated in the hot water outlet pipework to provide a regulated water temperature at the tap. The valve should be connected between the cold water supply and the hot water outlet following the instructions supplied with the valve. Discharge Pipework Note: Water discharged from the safety valve outlet may be very near boiling point and exit at a high flow rate. The unit comes with an expansion relief valve. A tundish must be mounted vertically and be in a visible location beside the water heater see connection diagram. Run a length of 15mm copper pipe form the outlet of the temperature and pressure relief valve to the location of the tundish so that the pipe runs vertically downward beside the water heating unit. The outlet of the expansion relief valve should then be T d into this pipe. Connect the tundish to this vertical pipe (D1) and run a vertical drop of 300mm of 22mm copper pipe, or larger (See D2 in table) form the exit of the tundish. Continue the length of D2 discharge pipe using minimal bends and a continuous fall to discharge water to a safe and visible position. The resistance to flow of the discharge pipe should be less than 9 metres of straight pipe. To work out the minimum diameter of discharge pipe to be used: From table 1 calculate the resistance to flow created by the number of bends required in the discharge pipe from tundish to end of the pipe. For example: 4 x 22mm elbows = 4 x 0.8m = 3.2m From table 1, the maximum length of straight 22mm pipe is 9.0m. Subtracting the resistance of the elbow: 7

9.0m - 3.2m = 5.8m, hence the maximum total length of 22mm copper pipe with 4 elbows will be 5.8m. Where a longer run is required, a larger diameter discharge pipe D2 and tundish will be required. In these cases the above calculation should be repeated for 28mm and 35mm pipe to check that the maximum pipe length is not exceeded in a similar manner. Valve Outlet Size G1/2 (Supplied) Table 1: Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes Minimum size of Minimum size of discharge pipe discharge pipe D1 D2 from Tundish 15mm 22mm 28mm 35mm Maximum resistance allowed, expressed as a length of straight pipe (i.e. no elbows or bends) Up to 9m Up to 18m Up to 27m Resistance created by elbow or bend 0.8m 1.0m 1.4m Discharge Pipework Connection It is required that the end of the discharge pipe be no more than 100mm above ground level of the pipe discharged into a gully with the pipe end being below a fixed grating. High level discharge may be done by discharging into a metal hopper and down-pipe of at least one size larger that the discharge pipe. Connect the cold mains water supply to the blue pipe of the water heaters using a standard 15mm compression fitting (not supplied). Thermostat Setting The thermostat can be set to provide temperatures between 18 C and 68 C. Setting at high temperatures prevents bacterial growth in the stored water and allows the water to be mixed down to lower temperatures using a mixer valve. Electrical Supply The unit must be supplied via a double pole isolating switch with a contact separation of at least 3mm in both poles. The supply should be fused with a 13 amp fuse. Run the wire from the isolating switch to the connector within the unit. The connections should be made as follows:- i) Connect the Green and Yellow wire to the Earth terminal marked with the symbol ii) Connect the Blue wire to the terminal marked with N Neutral iii) Connect the Brown wire to the terminal marked with L Live Warning! DO NOT switch on the electricity supply until the commissioning procedure below has been completed! The unit must be full of water BEFORE attempting to switch on the electricity supply. 8

Resetting The Unit If the unit is switched on but is supplying cold water, check the power supply to the unit and check if the neon light is on. If the neon light is not on turn the temperature regulator to increase the temperature. If nothing happens and the neon light is still not on, it may be that the unit has tripped and may need resetting. This should be done by a competent person. 1) Switch off the electrical supply 2) Unscrew the cross head screw retaining the access cover and remove it. 3) Check for any water in the unit and for any loose electrical connections 4) Press the reset button 5) Replace the access cover and reinstall the unit 6) Check for leaks around the pipe connections and then restore the electrical supply 7) The neon light should then light 8) If the unit continues to trip isolate the unit and contact Crown Water Heaters technical support NB The neon light only lights up when the unit is calling for heat. When the unit has reached temperature the light will go out. On no account should the unit be removed without first contacting Crown Water Heaters on Tel: 01902 310678 Commissioning Before switching on the cold supply, visually inspect the installation to check that it complies with the requirements for expansion, pressure reduction and that the discharge pipe is unobstructed and will discharge water to a safe visible place. Visually check the wiring and test that there is a good earth connection to the unit. If the installation is correct, open the hot tap and the services valve to allow water to fill the cylinder and run freely through the tap. Allow the water to run to flush out any dirt from the pipework. Close the hot tap and check the unit and pipework for leaks. Twist the top of the expansion relief valve and ensure water is discharged into the tundish. Turn the thermostat fully anti-clockwise to its minimum setting. Switch on the electrical supply and ensure that the upper and lower LED s light up. After a short while, when the temperature set at the thermostat has been reached, the lower LED should extinguish. Increasing the temperature setting by turning the temperature dial clockwise should cause the LED to re-light until the new temperature has been reached. Maintenance and Servicing It is recommended that the unit be serviced regularly to ensure that all safety devices are functioning properly and that the expansion vessel is charged to the correct level. Servicing should be carried out by an authorised Crown engineer. Servicing should as a minimum include, the manual operation of all safety valves, check and recharge of the expansion vessel and operation of the thermostat. All joints should be checked for leaks and the discharge pipe checked by expelling water from the safety valves for a period to check that water freely flows to a safe and visible place. 9

The charge in the expansion vessel should be checked: this may be done by isolating the electrical supply and mains water supply. Open the hot tap to depressurize the system. Using a pressure gauge check the pressure at the valve on the expansion vessel. This should read 3Bar. If the pressure is lower than this, pump up the pressure to 3.5Bar using a suitable foot or hand pump. In hard water areas scale may form within the cylinder reducing the product s efficiency. It is advisable to occasionally switch off and disconnect the unit from the supplies and remove the unit from its installed position. The flanged heating element may then be removed to allow access to the vessel for removal of limescale Removal of Element Plate After disconnecting the unit from the mains water and electricity supplies, remove the top cover using a screwdriver. If required, the electric cable may be removed from the terminal block to aid removal of the immersion heater. Remove the electrical connections to the element. The element plate is removed by undoing the six retaining screws and lifting flanged element from the cylinder. When refitting the element plate it is advisable to replace the gasket. Checking and Replacing the Anode The anode can be checked and replaced if necessary by disconnecting the unit from the mains water and electricity supplies, remove the top cover using a screwdriver. If required, the electric cable may be removed from the terminal block to aid removal of the immersion heater. Remove the electrical connections to the element. The element plate is removed by undoing the six retaining screws and lifting the plate and element from the cylinder. The anode can then be unscrewed and replaced with a new anode obtainable from Crown Water Heaters Ltd on 01902 310678. Optional Accessories Expansion Kit A Pressure Reducing Kit B Vessel Mounting System kit GA 2 Litre Expansion Vessel Check Valve 3.5Bar Pressure Reducing Valve with Gauge 2 Litre Expansion Vessel Check Valve Vessel Mounting Bracket 10

Troubleshooting By Service Engineer Problem Possible Causes Action No hot water No electricity supply Check power LED is lit up Warm water dripping into tundish during warm-up Warm water dripping into tundish when system cold High volume hot water discharge into tundish (from temperature and pressure valve) Thermostat turned down Thermal cut-out operated Blocked strainer on pressure reducing valve Expansion vessel has lost charge Expansion down mains water supply not effective Pressure reducing valve not fitted or faulty Expansion relief valve faulty Both thermostat and thermal cut-out failed Turn the thermostat up and check heat-up LED lights up Check electrical components and replace thermostat Break connection on inlet side and clear debris from gauze strainer Recharge expansion vessel to 3Bar Fit expansion kit Fit pressure reducing kit or replace faulty unit Replace expansion relief valve Replace thermostat and thermal cut-out devices USER INSTRUCTIONS Operation The Crown undersink water heater is a highly insulated product that is designed to be left switched on for extensive periods, providing hot water when required. The thermostat will vary the water temperature stored between 5 C and 68 C. For hand washing purposes the thermostat should be set to mid-range position to avoid scalding. If a mixer valve is installed in the hot water outlet the thermostat should be set at maximum setting. The use of high temperatures (>63 C) reduce bacterial build-ups in stored valves. When the mains electricity to the unit is switched on the upper LED will illuminate. When the thermostat switches the element on, the heat-up lower LED illuminates to show that the water is being heated. 11

Importance Notice If water is seen discharging from any part of the system, switch off the electricity supply and the water supply and contact the Crown Customer Services team:- Tel: 01902 310678. Fax: 01902 425707 Email: service@crownwaterheaters.co.uk Warranty This warranty does not affect your statutory rights as a consumer. This Crown water heater is made from the highest quality materials and should provide numerous years of trouble-free operation. Crown guarantee all components for two years, provided the unit is installed and maintained in accordance with these instructions; only safety controls and valves supplied by Crown are used; the unit is regularly serviced as detailed within this manual and any fault that should occur is reported and rectified at the earliest time by Crown service agents. The guarantee does not cover damage due to effects of limescale build-up. The unit must be connected to a mains cold water supply as provided by the local water authority. The warranty does not cover the unit when connected to other water sources. 12

CROWN WATER HEATERS SERVICES POLICY/GUARANTEE In the event of you needing to contact the Crown Customer Service Department the following procedures should be followed: 1 Before contacting the Crown Customer Services Department you should ensure that you have the model number, power rating, serial number and date of purchase. 2 The Crown Customer Services Department will be able to inform you whether the fault can be rectified by the provision of a replacement part or replacement unit on a supply only basis. CUSTOMER SERVICES TEL 01902 310678 GUARANTEE Crown Water Heaters Ltd guarantee the unit for a period of two years, from the date of purchase, against mechanical and electrical defects arising from materials or manufacturing defects, providing the product has been installed by a competent person in accordance with the fitting instructions. Crown Water Heaters Ltd undertake to repair or replace, at their discretion, without charge provided the product has been properly maintained, installed and operated in accordance with the operating instructions. Any component found to be defective during this period, as a result of misuse or damage, or the effects of scaling, will not be covered by this guarantee. This product must not be modified, repaired or taken apart except by a person authorized by Crown Water Heaters Ltd. The Guarantee is only valid within the United Kingdom and does not cover product used commercially. This Guarantee does not affect your statutory rights. Crown Water Heaters Ltd Sunbeam Studios, Sunbeam Street, Wolverhampton WV2 4PF Tel: 01902 310678 Fax: 01902 425707 13