EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Similar documents
EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

AV-3008 LED, SOL AV-3008 GSM (for LED keypads)

EasyLoader AV-2005 & AV-2008

EasyLoader AV-2016D, AV-2016DP AV-2055D, AV-2088D. (for LED keypad) Integrated Alarm Control/Communicator. Installation and Operation Manual

EasyLoader. End User Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CC408. Quick Reference Guide Solution 880

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

CC488. Quick Reference Guide Solution Ultima 880

AV-4000 LED, SOL AV-4000 GSM (for LED keypads)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Property of Monitronics Inc

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

AXI LED USER MANUAL (REV. 1.0)

INSTALLATION MANUAL PC25OO

TABLE OF CONTENTS TABLE OF CONTENTS 1

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Control/Communicator Installation Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

VAP304 PRO INSTALLATION & OPERATION MANUAL

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Security System. User Guide for the LED Command Center

Radionics D4112 Program Sheet

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Independent Zone Control (I.Z.C.)

Quick Programmer s Manual

Solution 862 Installation Manual ISSUE 1.30

Control/Communicator

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Watchguard WGAP864 User Manual

CA60Plus. Installation manual

INSTALLATION MANUAL PC15OO

Security System. User s Guide for the Text Command Center

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Solution Ultima Series Operators Manual ISSUE 1.00

2000 Series. Program Entry Guide. Control Panels

Version 1.03 January-2002 USER S MANUAL

Solution Ultima 862 Operators Manual ISSUE 1.10

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

First Alert 1200C Installer Notes M. Leuck

Contents. Glossary

INSTALLATION MANUAL PC56O. Version 1.OA

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

GEM-P800 Programming Instructions

ITI Caretaker Basic Commands

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Installation Manual Premier 412/816/832. Issue 10

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

User s Information Guide R2A

EVO192 v3.0 Fire and Burglary What s New

3 User s settings. 3.3 Internal clock setting

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Property of Monitronics Inc

INSTALLATION MANUAL & PROGRAM RECORD SHEET

System Introduction. 1.1 Specifications

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Series. NX-4-EUR Control Panel. Installation manual

Training Manual Multi-Language with Wireless

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

GEM-P800. Control Panel/Communicator. Installation Instructions

L900 series USER MANUAL

NX-148 LCD CODE PAD TABLE OF CONTENTS

PROGRAMMING INSTRUCTIONS

SECURIT 700L PLUS ENGINEERING MANUAL

PROGRAMMING INSTRUCTIONS

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Using Your. Security System With LED Keypad S5030, S5031, S5032

System Programming Guide

JA-63 Profi User manual

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

SMS8 Alarm Control Panel

JA-63 PROFI Alarm System MGK55402

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

LS800S Intruder Alarm System. Engineering Manual

Transcription:

EasyLoader AV-2004, AV-2048 Integrated Alarm Control/Communicator Year 2000 ready Express Installation and Operation Manual Version 3.06 (with very slow zone) Edition II This product is subject to continual enhancement and therefore specifications may be changed or altered without prior notice Item: 4718_2004 www.av-gad.com

1. INTRODUCTION System planning When the panel reaches you it will be factory programmed. This is done for testing purposes but also can be used for installation if required without first entering to programming. This present program is referred to as Factory Defaults. This is a short format manual. Make sure you are familiar with all the features and options before attempting to install and program. Refer to the full version manual (AV -2005/8 full version), this manual includes glossary and more details. For PRO type, panels refer to the AV-705/707 manual. System supplied with or without transformer according to approval requirements in each country. Order the keypad transformer separately (few types available). Blinking h after power -up, reminds to adjust system s clock and date (see page No. 10). Default arming code is 1, 2, 3, 4. Version 3.00 ( D Suffix): New and improved PCB, DTMF control (arm, disarm, etc) option with D panels, PRO panels available, panel version identifies itself as AV-2004/48D (EasyLoad software), self test at initialization (STI) - Dial LED blinks for the first 50 seconds after power on, new factory defaults, address 052: Set the CS signal test per days, remote text transfer for PRO panels. RS-232 and SVM sockets added. Home Automation features for remote control of output A1. Version 3.02: First alarm indication by DTMF, A1 at Latch mode. Version 3.04: New at 072-4, activate ON output to drive ADSL filter line disconnect, added 999 to exit programming mode, during Answer Now mode keypad display CA, telephone line monitor intervals (add 094) changed to minutes. 3.04A: Zone 4 or 8 as aux. Key. Version 3.06: AV-2048D new zone wiring at 075-2, new feature: Enable Keypad & Sir sounds at Home mode at 075-1. 3.08: Added very slow zone for refrigerator defrosting alarm. Electronic Fuse Overview The Electronic Fuse device is installed as a series element in a circuit. In response to an over current it protects the circuit by going from a low-resistance to a high-resistance state that reduces the current to a level that s safe for the circuit elements. The change in resistance is a result of a rapid increase in the temperature of the device. Like traditional fuses, Electronic Fuse devices interrupt the flow of dangerously high current. However, unlike traditional fuses, they automatically reset after the fault is cleared and power to the circuit is removed. Because they are solidstate, Electronic Fuses are also better able to withstand mechanical shock and vibration, and provide reliable protection in a wide variety of applications. In case of over current, carefully touch the fuse body (yellow round disc), hot body means the Electronic Fuse in protection mode, disconnect the load and wait 2-3 minutes until the fuse body get cooler. 2

2. MOUNTING THE CONTROL PANEL Refer to detailed wiring diagram. Note: h is displayed after power-up to remind installer to set the time; h will be removed after time setting (by using keys 0 and 1 refer to page 10). Select a mounting location as following: 1. A continuously powered (non -switched) AC power source, compatible with step-down supplied transformer. Make sure the mains (110 or 220V) are fused. 2. A cold water pipe Ground, ideally no more than 3 meters (10 feet) from the panel. Use 16 AWG or 0.5 mm 2 wires. 3. Telephone line socket. Always install the control panel box in a hard-to-access location Locate one of the Keypads near the Entrance/Exit door. Install a tamper-switch to secure the control panel box. Connect the tamper-switch to a 24H zone (is active at all times). Zone Wiring Mode: Your system provides few ways of zone wiring: Non EOL resistor loop, EOL resistor loop. The EOL loop protects the zone lines against tampering. It s recommended to use the EOL mode; it s safer and keeps lower EMI and RFI interference. Via programming, select either End-Of-Line (EOL.) resistor protection, or non-eol mode. The EOL is defined at address 029; the default program is set at non-eol for all zones. To select EOL mode enter at address 029 the required zone to be EOL, or enter 0 to enable all zones as EOL. Note: Address 029 at the AV-2048 is blocked. Only EOL mode is available. If EOL mode is selected (recommended), install the EOL resistor (2.2K/0.25 or 0.5W) inside the detection device (e.g. PIR, Magnetic Switch). Maximum zone wiring length is 200 meters using 0.5-mm 2 wires, EOL mode wiring is highly recommended. Note: Zone and Sector are interchangeable terms in this manual. Always use EOL resistor, to prevents EMI and RFI interference and higher security An EOL zone will report Tamper alarm in case of zone shorting (if it has been EOL programmed). For connecting N.O. zones, programming is required, refer to address 042. Do not connect few sensors to one zone in EOL mode. AV-2048, eight zone panel zone wiring The AV-2048 board looks similar to the AV-2004, the AV-2048 board carries a specific identification label. The hardware and software are different. The AV-2048/D works in EOL mode (can t work in none EOL), it means always using EOL resistors. The zones are referred to V. Connect two wires to the same terminal, one wire in series with the 2.2.K resistor and the sensor contacts (relay), the other wire in series with 4.7K resistor and other contacts. Refer to figure 1. Tamper alarm per zone is not available with AV-2048. 3

EASYLOADER AV-701 ARMED STATUS SHUNT FIRE Siren Delay Delete Display Chime Status Test Program Reset ZONE DISPLAY Telephone ARMED STATUS SHUNT FIRE Delete Delay Test Display Chime Program DISPLAY ZONE Status Telephone Reset ARMED STATUS SHUNT FIRE Delete Delay Test Display Chime Program DISPLAY ZONE Status Telephone Reset EASYLOADER AV-701 ARMED STATUS SHUNT FIRE Siren Delay Delete Test Display Chime Program ZONE DISPLAY Status Telephone Reset The 2.2K resistors are wired with the odd zones (1, 3, 5, 7), the 4.7K are wired with the even zones (2, 4, 6, 8) as table below shows, for latest AV-2048 starting version 3.05. Terminal wire No. Resistor 2.2K Resistor 4.7K 1 Zone No. 1 Zone No. 5 2 Zone No. 2 Zone No. 6 3 Zone No. 3 Zone No. 7 4 Zone No. 4 Zone No. 8 Version 3.00 to 3.04 AV-2048/D Wiring (by Default) Zone 1+2 Zone 3+4 Zone 5+6 Zone 7+8 +12V -V 1 2 3 4 -V -V PIR 1 PIR 2 -V 2K2 Resistor Colors Red, Red, Red 2K2 4K7 Resistor Colors Yellow, Violet, Red 4K7 Figure 1: Optional zones wiring i n A V - 2 0 4 8 D f r o m v e r s i o n 3. 0 5 ( l e f t s i d e) Very Slow Response Zone This feature entered to AV-2048D PRO Version 3.08. At 032 select the zone to act Very Slow, at address 059 set the time in minutes, at 075-4 enable the Very Slow feature. 3. KEYPAD WIRING Display Zone 1 Display Zone 2 Up to two AV-701T/TI or four AV-702 Keypads can be connected to AV-2004/48 Control Panel. When few keypads are connected, wire each one directly to the panel, not from one keypad to the other. Refer to drawing in next page. Important Note: Up to two (2) AV-701T/TI or four (4) AV-702 Keypads can be connected to AV-2004/48 Alarm Control Panel When using few keypads connect them in parallel. Each keypad has four terminal wires: (+) Power, connect to + Aux. Power System Data, connect to OR ( ) Power, connect to Aux. Power System Strobe, connect to YE Panel Panel AV-GAD AV-GAD EASYLOADER AV-701 AV-GAD EASYLOADER AV-701 AV-GAD 1 2 3 Siren 1 2 3 Siren 1 2 3 1 2 3 4 5 6 4 5 6 4 5 6 4 5 6 7 8 9 7 8 9 7 8 9 7 8 9 * 0 # * 0 # * 0 # * 0 # Wrong Wiring Correct Wiring Figure 2: Wiring more than one keyp a d 4

When a non-blinking 8 is displayed and keys do not respond, it is an indication that the keypad is not communicating with the panel. Check wiring and polarity Wire length for each AV-701 Keypad should not exceed 100 meters (when using 0.5 mm 2 wires). For longer than 100 meter keypad wiring, contact manufacturer's consultant. For AV-701TIP (with tamper) run five (5) wires. Connect the TMP terminal to a 24H or Tamper zone. Power at Keypad should be a minimum of 11.5 Volts. IMPORTANT! Never run Keypad wires alongside telephone wires, high voltage wires, or transmitting antennae. Wire the keypad wires separately and not in same cable with other devices (telephone, PIR etc.) For proper connection, refer to wiring diagrams at the end of the manual. 4. SIRENS The control unit contains single siren outputs, protected by Electronic Fuse. Siren should be of an outdoor type with a minimum power of 15W, 8 Ohms Impedance. Enclose the siren in a metal housing, with anti-tamper switch protection. Siren mode is factory default, in Siren mode install only speaker-type sirens, which DO NOT contain sound driver or electronic modules. The alarm issued by the siren differs according to the type of zone. Bell Mode converts Siren outputs into 13.6V DC outputs (no sound is issued). Bell mode is applicable for driving self-powered sirens or bells, or combined sirens and strobes. 13.6V DC is issued at Bell mode. It s recommended to use Bella sirens series. In Bell mode, connect only sirens, which contain sound driver or electronic modules. Self contain Bell mode is programmable (address 072-1 and 073-3). This mode provides connection of Bells or Sirens that requires 13.6V at idle and 0V during alarm. Contact manufacturer's consultant before connecting higher power loads. To connect self-contained sirens, Bells, and inner-oscillating sirens, Bella siren series refer to address 072-1 for Bell mode. Bella sirens support internal battery charge and monitor for higher security. Warning, Output current for Bell should not exceed 1.0 Ampere 5. AV-2004/48 Remote Indication Terminals Indication ON A1 Application (-V) on closing (Arming) or if cross-zoning feature selected (-V) during alarm from the programmed zone 5

The A1 may be used to drive a low current Strobe Light (Xenon) that consumes up to 300 ma Home Automation feature: Momentary activation of A1 output for three seconds, via any DTMF telephone command (address 074-2). In case other features are selected for the same output, this feature is not applicable. 6. GROUNDING Lightning Protection The control panel must be earth grounded for lightning protection to work effectively, and in order to prevent RFI and EMI interferences. Connect the ground to a verified cold-water pipe using a minimum 16 AWG (or larger) wire. Run the wire via the shortest possible route. System grounding is compulsory Connect the Grounding wire to main board and to metal box. Note: Connect the Ground wire, to the terminal. This is not a minus (-V). Be careful of static discharge; before handling the main board touch a grounded metal. Before grounding the system, make sure to connect ground properly, check that ground does not transfer high voltages. 7. BACK-UP BATTERY Make sure to connect the Battery in the correct polarity! The system's Red wire is the positive pole (+) and the Black wire is the negative pole (-). The battery will provide power back up in case of AC power failure. Connect back-up battery to ensure proper operation of the system. Recommended battery: 7 Amperes per Hour (AH), 12V (sealed lead acid) type. A 7.2 AH battery backs up the control panel and a single keypad for approximately 8 hours. AV-2004 and AV-2048 panels accommodates a battery of up to 12V 7.2 AH (max.). A Electronic Fuse rated at 2.5A protects the battery. Add a power supply for installation with over three LCD keypad and/or if over ten high current sensors included. Refer to Av-Gad AV-21, AV-40 power supply and charger. The 4AH 12V battery fits in the ABS box, but the door is too tight, why? Note the following: 1. A small bulge on the box door supposing to hold the battery may displace the battery; place the battery near this bulge and not on it 2. Make sure that the battery is not laying on the wiring 6

8. TELEPHONE LINE WIRING and PROGRAMMING It s recommended to connect the control panel to an independent telephone line, if a device is in parallel with the alarm panel, this may grab the call first (like a message answer/fax) during remote up and download. Don t connect fax or answering machine in parallel on the same telephone line. Default dialing mode is DTMF. If Pulse dial is selected, the default is European Make/Break rate of 40/60 milliseconds (in Pulse dialing). Dialing mode is programmable (refer to programming sheet addresses 084). Connect the telephone line to TEL-LINE terminal, if handsets connected to same line connect them to PHONES, when system attempts to dial the PHONES is disconnected. Do not connect to ISDN or other digital telephone system. Most ISDN converters contain an Analog line; connect the Analog line of the ISDN to the panel TEL-LINE terminal. For DSL/ADSL connect a dedicated lien filter supplied by local Telecom Company. 9. BEFORE POWERING UP Place Control Panel in a well-ventilated location, and as far as possible from any heat source. Do not place high power RF wireless transmitters near Control Panel. Check for proper grounding. Make sure detectors, keypads or any other devices are connected to the Control Panel in their correct polarities. Connect a momentary voltage to the siren; making sure a beep is sounded. In case of no beep, check for a short circuit or improperly connected wires. Power-up through transformer, if system seems to operate properly connect the battery. Do not connect any sensors or other devices to the battery terminals. The AV-2004/48 are compatible with 12V smoke detectors, common collector type or relay (-) output on alarm. In the AV-2004/48, a momentary switch achieves smoke detector reset. The switch (or relay) disconnects power to smoke detector following a smoke alarm. 10. AV-2004/48 STANDARD KEYPAD FUNCTIONS Common Terms in this Manual SHUNT BYPASS are interchangeable terms Program Mode Provides features programming, P is displayed, alarm is disabled Use Mode Normal operation mode AV-701 AV-701T AV-701TI AV-702 are identical and interchangeable term 7

Short press access standard Keypad functions. The numbered keys (1 to 0) are used for Arming/Disarming (ON/OFF), Zone (Bypass), and other operation and programming functions. Short beep confirms each key press. A short press on the AV-701 keypad key accesses the following special functions: Chime 5 0 0 Instant Arming. Press key 5 (requires programming at 071-2) to Arm. Zone Bypass, by pressing key 0, followed by entering the Zone number. Zone Bypass via Code (requires programming, see address 071-5). Press key 0, while 4 LEDs are blinking, enter valid user code; When only 2 leftmost LEDs are blinking, enter zone number(s) to be bypassed, 4 LEDs stop blinking, LED remains on to confirm zone bypass, within 20 seconds enter your user code to Arm the system. 0 then 0 AV-2004: Group Bypass, by two presses on key 0. Group-Bypass is operative only if System is armed within 20 seconds after entry of this feature. Yellow LED will flash and h (Home) will be displayed for 1 second in confirmation. AV-2048 Arming with Group Bypass: 2 nd Group Bypass added, (address 034) and the procedure enhanced; after selecting the Group Bypass, system is armed (without code entry). To bypass 1 st group: Press 0 and hold-down 1, to bypass 2 nd group press 0 and hold-down 2, to bypass both groups press 0 and hold-down 0. Yellow LED will flash; h (Home) will be displayed for 1 second in confirmation, then the Armed LED lights-up in confirmation. When Group Bypass is selected the LED stops blinking eight seconds after arming. This will prevent the LED light from disturbing sleepers near the keypad. B. There is no exit/entry delay-warning buzzer at the keypad. C. There are no beeps at the keypad until an alarm occurs or Group Bypass is canceled. D. When the keypad LEDs are turned off after Arming (requires programming), touching the keypad will turn them on for 5 seconds. For Group Bypass with code (requires programming); Press key 0, while four LEDs are blinking, enter valid user code. When only 2 left-most LEDs are blinking, press again 0 key, h will be displayed and, 4 LEDs stop blinking. LED is blinking to confirm Group Bypass, enter your user code to Arm system within 20 seconds (otherwise Group Bypass will be removed). 8

11. AV-2004/48 HOLD-DOWN FUNCTIONS (AV-701, AV-702 SERIES) To access the hold-down functions hold down the key for approximately 2 seconds. Holds down functions are confirmed by a prolonged beep. Hold-Down Functions: Siren Display Status Delay Delete Chime 1 2 3 4 5 Telephone6 Key 1 SIREN TEST Key 2 SHUNT DISPLAY Displays shunted zone(s). Key 3 STATUS DISPLAY Displays troubled or malfunctioning zone(s). Key 4 DELAY DELETE (INSTANT PROTECTION) Holding-down key 4 cancels Entry Delays in zones selected as Delayed zones. All zones become Instant. d is displayed in confirmation. Instant Protection becomes effective only if System is armed within 20 seconds following hold-down of key 4. Key 5 DOOR CHIME Enable Chime mode. Door Chime operates on Chime-programmed zones. Hold-down key 5 enables and disables the function; chime mode is not affected by Arm/Disarm. Chime mode is confirmed by c display on keypad. Key 6 DIALER TEST & FOLLOW-ME PROGRAMMING Test is performed in Disarmed mode. Function Via AV-707 Series Keypad Via AV-701 Series Keypad Displays Programmed Follow Hold-down [6] Me Telephone Numbers Without Dialing Follow Me telephone number programming Hold-down [6] then holddown Programmed Telephone number Verification (Display and Dial 4 telephone numbers) [6] again Hold-down [6] then holddown [7] To display the programmed telephone numbers without dialing hold down key 6; within a few seconds, c will appear on the display, followed by the (programmed) Follow Me telephone number. When programming telephone numbers that requiring an inter-digit delay ( Pause ) during dialing, Hold-Down key [0], a momentary P will be displayed (Delay duration is 3 seconds). The Follow-Me number will be displayed, or displayed and dialed, followed by display-and-dial of up to three additional telephone numbers. 9

Telephone6 Siren then 1 Address 092 enables Answer Now feature (answers remote computer after 1 ring). The user attending the control panel can reduce the number of rings before answer to one ring. To cancel the Answer Now feature hold-down 6 and hold-down 0. This feature is useful if the control panel was programmed not to answer incoming calls (programming of 21 rings or greater at address 091). For Answer Now to be available, program 01 at address 092. User should hold-down key 6 and then key 1, before the call is made to the control panel. The panel will acknowledge the command with two beeps and A. is displayed. The feature remains active for 5 minutes after entered, enabling programmer (at remote computer) to enter the panel. Test 7 Key 7 FAULT FIND Fault Find enables testing of all detection devices. Fault Find mode can be entered only during the 15 seconds following system Disarm. 24H, Fire or Panic alarm will stop Fault Find mode. Hold down key 7, confirmed by F on Keypad display. Open and close each zone to test. A one-second beep confirms detection of zone opening. Three beeps indicate zone closing. Quit Fault Find mode by arming the system. Program Reset 8 9 Key 8 PROGRAM Key 8 accesses Program mode and user code programming (changing). Key 9 RESET Reset performs the following functions: 1. Cancels last Keypad entry 2. Stops the communication test (triggered by hold-down key 6) 3. Resets Day Zone Alarm at Keypad 4. Exits Programming mode (features, telephone numbers, etc.), or type 9,9,9 to exit programming mode (active in LED and PRO panels). Key 0 Hold-Down functions 1. 0 Key 0 Concise Alarm History: Hold down key 0 to display the last alarm sequence. New alarm will create a new history instead of the old one. 2. 0 and 0 Detailed Events History (requires programming): Hold down key 0 and again hold down key 0 to display up to 36 events, including: System opening and closing by user number, opening or closing time, zone caused alarm, AC fail. By holding-down key 0 twice, three LEDs start blinking to indicate a special operation mode. The events are being displayed from the most recent to the oldest event. The event is displayed as following: 10

XX - Event number (from 01 to 36), then HH_MM (Hour and Minutes) Event Time, Event (alarm or opening/closing). More events are reported in the PC up and download log events. Translate the display as following: u (user number 1 to 8) o or c - opening or closing Zone causing alarm-will blink twice tx - Tamper alarm form zone causing alarm (X) H - Means Panic Alarm Note: 3 lines () indicates power fail. In history events AC fail is displayed. For example: Display Zone no. blinks twice 01 2 2 _ 2 4 u 1 o 02 2 3 _ 0 5 7 7 03 2 3 _ 3 5 H H 04 0 0 _ 0 8 u 1 c - - Sign then long beep indicates end of History Event 01 Time User 1 Opening Event 2 Time Alarm Zone 7 Event 3 Time Alarm Zone H Event 4 Time User 1 Closing During zone number display, keypad display blinks twice to indicate the zone number. Browsing through Events History Keys used for browsing: Display 2 Skip forward to next event Chime 5 Program 8 Display again current event Skip backward to previous event Reset 9 Cancel History Event Mode and exit When last event is displayed and attempting to move forward (key 2) a blank sign is displayed and a long warning beep indicating that it is the last event. Press key 8 to move backward, if no key is pressed Event History stops and system returns to Use mode. When starting History Events mode the events are displayed from starting to the end without any break, until any browsing key had been pressed. During History Event browsing, system will respond only to alarm or panic, Arming denied. Alarm or Panic during History Event mode will quit this mode and system will set to Use Mode (normal operation mode. Clearer History events are available when using the download. 3. 0 Status and 3 Concise History of Tampered Zones: Hold down key 0 and then hold down key 3 to display the Tampered zone alarm sequence. New alarm will create a new history in place of old history. 4. 0 Siren and 1 Display and Setting of System Time: Hold down key 0 and then hold-down key 1, three LEDs are blinking, wait for the display of system time in 4-digit format. To set new time, hold down key 0 and then hold down key 1. Do not wait for time display; enter the new time in 24-hour format. 11

The local clock time is not stored in system memory; clock must be adjusted after power-up. System time is reset to 00:00 after power-up, h will be displayed to remind user to set time, h will be removed after setting new time. 5. 0 Display then 2 Display and Setting of System Date: Hold down key 0 and then hold-down key 2, 3 LEDs are blinking, enter date; dd mm yy. When history displayed at keypad, time is displayed. The up and download PC software synchronies time and date. The local date is stored in system memory; date must be adjusted after long power-fail. Years 78 through 99 translated as 1978 to 1999 Years 00 through 77 translated as 2000 to 2077 6. Reset Events Memory: In program mode press 200 then 04 to erase all events from memory. 7. 0 Chime 5 then Display Last 2 Users: Hold down key 0 and then hold down key 5 to display user number and System opening or closing time. o is displayed for Opening (Disarming); c is displayed for Closing (Arming). 8. 0 Reset (do not hold-down) and press 9 cancel all Bypassed Zones. * Keypad Panic # (do not hold -down), will display - to Keys PANIC BUTTON Holding down * and # keys will trigger Panic alarm. H will be displayed (zone H ). For Silent (used with Panic button) Panic alarm, remove siren and buzzer activation by programming the Panic Zone so. Panic zone program as 24H zone type, N.O. type, fast response type. To quit zero hold-down functions, hold-down 9 To cancel Hold-Down function accessed by keys [0], [6] and [7]; Hold-Down key 9 (Reset) 12. SYSTEM CODES Up to eight Arm/Disarm codes and one installer (dealer) code are available; each code contains one to six digits. Do not use 0 as the first digit in a code. Do not use 5 as first digit in a code number if Instant Arming via key 5 was program. The user(s) code must not start with the same numbers as the installer programming code (1994). Do not use same codes or same first digit for few codes, for example; if code of user one is 1,2,3,4 avoid programming code of user two to be 1,2,5,6. 1. Default Arming and Disarming Code 1 2 3 4 (Code No. 1) - Use 1234 as Arming Code (also called Owner Code). Use code No. 1 to program a new user code. Upon setting new Arming & Disarming code, the default user code 1234 is automatically replaced. For setting system codes to default, power up by applying AC and battery and immediately hold-down keys * Keypad Panic #, after 2 nd beep release keys, in confirmation U blinks 3 times. 2. Code number 8 as Visitor Code (requires programming) Program the Arm/Disarm Code No. 8 as a one time code, for employees and one-time visitors. 12

This code is valid 30 seconds from Arming. After 30 seconds, the code is not valid. Entering code No. 8 will delete zone bypasses including auto-bypass. 3. Code number 9, Programming Code (Installer Code). This code enables entering the programming mode (system features programming) at the Installer level. The factory default programming code is 1 9 9 4. The programming code may be installer-programmed. Installer Code does not Arm or Disarm system. 4. User Codes - (Arming/Disarming code); each code is 1 to 6 digit. System provides eight users programmable codes. 13. Remote Key and Wireless Arming & Disarming The AV-2004/48 enables Arming and Disarming by remote momentary or latch key-switch (as programmed in address 071-7), which is connected to JP1 KEY and - Aux. Power (Refer to Wiring Diagram). Cable set for connecting to JP1 requires order separately. When using remote key-switch, wire length should not exceed 10 meters. A Momentary pulse (momentary trig) between KEY terminals will Arm and Disarm the control panel (close the instant and 24H zones Prior to arming.) System reverts to previous status with next momentary pulse. (Refer to Wiring Diagram.) For Arming/Disarming via Wireless Radio Remote, connect receiver's relay to KE and -Aux. Power terminals. Verify the receiver relay mode, momentary, or latch, and set system accordingly. For fast Remote Key wiring, the AV-2004/48/M contains a fast-insert connection, a dedicated wired connector is available (not included in the standard AV-2004 and AV-2048). In most cases the Key connector is applicable for emergency Disarming Short the key terminal with screwdriver. For remote arming with wireless remote transmitter use the A..RX and AVS22. Starting version 3.04: Zone 4 or 8 may function as auxiliary remote key input, programmable at address 050-3. The Aux. key Arms without Home (group) mode, sounds siren beep when Arming (if programmed), sounds siren beeps when Disarming (if programmed). 14. Remote Access via DTMF General Description Starting generation III alarm panels ( D suffix) includes the added functions for remote control via DTMF phone. DTMF commands are possible when the panel call your phone, or by calling the panel. The DTMF remote control functions: Check the status of the control panel (Armed/Disarm, Alarm in progress) Arm or disarm the control panel Bypass zones or clear all bypassed zones Stop the dialer report during alarm Momentary activate A1 (alarm) output for three seconds First Alarm indication - by a number of beeps per zone, special tune for Panic alarm The same options are available when a call is received from the control panel during an alarm condition. 13

To enable the DTMF control program address 074/6 Enable remote access by telephone, and 074-2 Enable A1 activation by telephone. Keypad online conformation and DTMF functions history When the control panel detects the first DTMF key, five short beeps sound at the keypads. The keypad activation shows the user at the remote site that a DTMF connection takes place (in case of mistaken connection or similar). During the remote access the keypad display 'd' and all LEDs blink fast from time to time. When the call ends, the three short beeps sound at the keypads. When the user code is in process, the keypad display shows a line for each code number entry (disclose the code), then each DTMF number pressed show the received number. History log: Each call, confirmed by a valid user code, is recorded in the events history. Each "Arming/Disarming" is recorded in the events history. "Last users" history will display 'ut' for "user "telephone, followed by the User number. Notes: 1. The keypad buzzer or other loud sounds may jam your DTMF entries, in case the keypad is close to your DTMF telephone, during testing disable the buzzer. 2. When entering the DTMF commands wait for quit period, if entering commands during the system confirmation tunes, or other tunes the panel may miss the DTMF entries. The panel calls the user during alarm When the control panel calls the user during alarm, it will first generate the siren sound for about 30 seconds (to shorten this feature at address 085 Tel. Message Time, to 30, as default is 50 seconds). The siren sound will stop ten (10) seconds before the end of the call and a greeting tune will be sounded, after the greeting tune enter your code followed by #. To stop the dialer enter 6#, to get panel status enter 7#, to disarm the panel enter 2#. To end the process press 9#. The control panel will answer the call after the number of rings programmed at address 091 (or following the bypass answering machine" procedure). Commands Each command must be followed by the '#' key (Enter) in the remote phone. The control panel waits 4 seconds between the keys typed. When this time expires, previous keys input will be discarded. The key '*' cancels previous input. It s recommended to start with "learn" function [8X #] to identify the various confirmation tune. The commands: [0 X #] - Bypass zone (# is the Enter key) X is Bypassed zone 1 to 8 To clear all bypassed zone: 0 9 # The zone bypass command is valid only when the system is in Disarm position and not in Alarm position. [1 #] - Arm control panel. The control panel will be armed even with open zones. After the arming, a confirmation tune followed by an "armed" tune will be sounded ("Armed" tune: Short beep followed by a long tone.). The user can wait a few seconds to be sure that no alarm has been caused by open zones. In this case, an Alarm tune (siren sound) will be sounded. 14

[2 #] - Disarm control panel. The control panel will be disarmed. A confirmation tune followed by a "disarmed" tune will be sounded ("Disarmed" tune: Five short beeps). [31 #] - Activates A1 output for 3 seconds (enabled by programming 074-2) [6 #] - Stop dialer. The dialer will stop calling the programmed telephone numbers. This will affect only the current dialing process. A new alarm will re-start the dialer. Note that if the user answered a call from the panel or called the panel during a dialing period without Arming/Disarming/Stopping the dialer, the dialer will restart the cycle from the beginning. [7 #] - Check control panel status. The control panel will answer with an Armed or Disarmed tune followed by an Alarm tune if it is in an alarm condition. [7 and 7 #] - First Alarm zone, beeps count for the zone number. Report user the first zone that caused alarm. Arming or Disarming clears the First alarm zone reported by DTMF. [8X #] - Learn function. Using this command, the user can become familiar with the various sounds used by the control panel in the remote access procedure. Further details find in the dedicated paragraph. (X - The required sound). [9 #] - End call. The control panel will sound a confirmation tune and will hang up. 15. USER CODE PROGRAMMING Set New USER-CODE Program 1. Hold down key 8 2. While 4 LEDs are blinking, enter code No. 1 (default 1, 2, 3, 4) 3. If code is valid, four LEDs will stop blinking, and u will be displayed 4. The two left-most LEDs blink to indicate that the system is waiting for a new user code index (user 1 to 8) to be entered. 5. Enter the code index (1 for code No. 1; 2 for code No. 2, etc.) 6. The two right-most LEDs blink to indicate that the system is waiting for a new code (1 to 6 digits) to be entered. Not entering a user code is, voids the code. 7. Enter the new code; U is displayed for confirmation. 8. To quit code setting hold-down key 9. Set new USER-CODE in Installer program mode 1. While system is in program mode, enter address 099, u will be displayed 2. The two left-most LEDs blink to indicate that the system is waiting for a new user code index (user 1 to 8) to be entered. 3. The two right-most LEDs blink to indicate that the system is waiting for a new code (1 to 6 digits) to be entered. Enter the new code. 4. At Installer program mode, Installer Code (code no. 9) can be set. Installer Code index number is 9. 5. Upon code setting completion, system reverts to Disarm mode. Delete a USER-CODE Program 1. Hold down key 8 2. While four LEDs are blinking, enter code No. 1 (default 1, 2, 3, 4) 3. If code is valid, four LEDs will stop blinking, and u will be displayed 15

4. The two left-most LEDs blink to indicate that the system is waiting for a new user code-index (user 1 to 8) to be entered. 5. Enter the code index you want to be delete (1 for code No. 1; 2 for code No. 2, etc.) 6. The two right-most LEDs blink to indicate that the system is waiting for a new code. If user code is not entered, the code is voided; short sounder beep confirms code has been deleted. 7. It's possible to enter a new code; U is displayed for confirmation. 8. To quit code setting hold-down key 9. Auto Arming (version 2.09 and upper) Programming the time for Automatic Arming: - By Installer: Program (or display) hours and minutes at address 016. - By User: Enter to user programming mode. Hold down '8' ('A' is displayed); type hour and minutes in 24 hours format. To display, hold down '8' and wait. To disable Automatic Arming program 0000. After Automatic Arming is programmed, the system time can be set only via User Programming Mode: Enter User Programming Mode (hold-down 8 and 1234), hold down '1' ('t' is displayed) and type hour and minutes. Hold down '1' and wait for the time to be displayed. Holding down keys '0'+'1' to program the time is possible only if the Automatic Arming is disabled (otherwise an 'Error warning is displayed). 16. CROSS ZONE FEATURE (AV-2004 only) This feature removed starting version 3, not available with d panels. 16

17. AV-2004/48 Programming Sheet Version 3.06 Factory Default Program is as shown in table; Blank Square means no default program TELEPHONES SIGNAL & AUTO ARMING TEST TIME Tel. 1 Tel. 2 Tel. 3 Tel. 4 Time Auto Arm Time 010 011 012 013 014 016 (00:01) 00:00 Tel. 1 is also Follow Me. Maximum 16 digits + 4 pauses each Tel. Number. Tel. 2 and 3 are communicator option. Test signal to central station (014), enter time in 24 hour format. Codes are defined at Addresses: 052, 073, 237, 255. To insert * in the phone number; Program system to dial in DTMF, Hold-down keys # and * (as panic), A will be displayed. For Pause during dialing, hold-down key 0. Zones 5-8 are applicable with AV-2048 ZONE FEATURES Feature Address 1 2 3 4 5 6 7 8 Fire zones 019 Zone In Use 020 1 2 3 4 5 6 7 8 Entry/Exit Delay 1 021 1 Entry/Exit Delay 2 022 Entry / Exit Follower 023 2 24-Hours Zone 024 Day Zone 025 Green Zone (one shot alarm) 026 1 2 3 4 5 6 7 8 Swinger Shut-Down 027 Chime 028 1 NO-EOL Resistor (not @ 2048) 029 1 2 3 4 Enable Zone Tamper (not @ 2048) 030 Delayed Power-Up 031 Fast or Very Slow Response ** 032 Group Bypass I 033 Group Bypass II 034 Manual Bypass 035 1 2 3 4 5 6 7 8 Siren Out 036 1 2 3 4 5 6 7 8 Alarm 1 (A1) Out 037 1 2 3 4 5 6 7 8 Reserved 038 Reserved 039 Dial on Alarm 040 1 2 3 4 5 6 7 8 Sounder on Alarm 041 1 2 3 4 5 6 7 8 N.O. (normally open) zone 042 Panic Zone 045 Values marked with ( ) are the factory default programming Keypad Panic Alarm 050 Tamper Alarm 051 Siren on Panic 1 Tamper zone as 24H zone 1 Alarm 1 On Panic 2 A1 on Tamper 2 Zone 4 / 8 (2048) as aux. key 3 Tel. Line Test at Disarmed 3 Reserved 4 Reserved 4 Telephone Report (5) Tel. Line fail activates buzzer 5 Enable buzzer on Panic 6 Tel. Line fail activates siren 6 Enable buzzer on Panic 7 Dialer Report AC Power Fail 7 Add. 052, CS test day: 1 - Sun 2 Mon, 3 Tues, 4 Wed., 5 Thu., 6 Fri., 7 Sat., 8 - All week's days, 0 Clear all TIME-OUTS AC fail report delay Zone Response time Entry Delay 1 Entry Delay 2 ** Exit Delay ** Sec's x 4 Siren Time ON Siren Time OFF Siren Time A1 Time Reserve d Chime Time Abort Delay Minutes m. Sec Sec's Sec's x 4 Minutes Sec's Sec's Sec's - Beeps Sec's 058 059 060 061 062 063 064 065 066 067 068 069 1 0 0 5 1 2 0 0 0 8 0 4 1 5 0 4 3 0 0 0 0 3 0 4 Note: Address 059 adjusts the response time of zones selected as Fast Response. If Slow Response selected, the value in address 059 is in minutes, also set address 075-4. 17

SYSTEM FEATURES Values marked with ( ) are the factory default programming Feature 070 Feature 071 Enable-Siren/Bell Test upon Arming 1 Enable-Erase F. Me number on Disarm 1 Enable-Keypad 3 Beeps upon Disarming (2) Enable-Instant Arming via Key 5 2 Enable-Buzzer upon Entry Delay (3) Enable-Buzzer during exit delay 3 Enable-Keypad Tactile Beep (4) Enable-Display Alarmed Zone during alarm 4 Disable-4 LEDs display during Armed 5 Enable-Manual Bypass via Code No.1 5 Enable-Battery Test upon Arming (6) Enable-Lock in Armed after Tamper Alarm 6 Reserved 7 Enable-Momentary Key-Switch (7) Enable-Keypad Panic (8) Enable-Code 8 as one time code 8 Feature 072 Feature 073 Enable-Bell mode (1) Enable-Display troubled zones at Disarmed (1) Enable-Detailed alarm history (2) Enable-Test to central station each hour 2 Enable-Report Opening/Closing (3) Enable-Self contain Bell (0V at alarm) ** 3 Activate ON output for ADSL filter line-cut 4 Reserved 4 Enable-Report bypassed zones at Arming 5 Enable- Group Bypass when Arm with Key 5 Enable-Exit delay when delayed zones clear 6 Enable - 2 Siren Beeps at Key Disarming 6 Enable - ON output as SVM trigger * 7 Enable - A1 output time follows Siren time (7) Enable-codes reset to default by * & # (8) Enable - Outputs (A1, ON) 0V at active 8 Feature 074 Feature 075 Reserved 1 Enable K. Pad & Sir sounds @ Home mod 1 Enable-Activate A1 via DTMF 2 Enable 2048 New Zones Wiring Method 2 Enable-Auto reset zone after alarm timeout 3 Reserved 4 Enable Zone at 032 Very slow zone 4 Reserved 5 Enable DTMF control (D type or Ver. 3) (6) Enable Bypass Answer Machine 7 Enable-Echo Cancellation Tone (AUSTEL) 8 Enable - A1 output as Latching 8 * AV-2004D starting January 2005. ** Self-contained Bell is operative if Bell mode selected DIAL PARAMETERS Pre-Dial Delay Wait for Dial Tone Anti-Jam Dial tone Delay detection Dial Mode Tel. MSG Time Inter- Call Delay Re-Dial Cycles (max.) Pulse MAKE Pulse BREAK Inter Digit Delay Rings qut'y for modem Instant modem answer Ring Cycle Width Sec's Sec's Sec's 00=No 0=Pulses Sec's Sec's XX Cycle 5 ms 5 ms 50 ms Tel. 00=No 100 ms 01=Yes 1=DTMF Rings 01=Yes (1-25) 080 081 082 083 084 085 086 087 088 089 090 091 092 093 0 3 0 4 1 0 0 1 0 1 5 0 2 0 0 3 0 8 1 2 2 0 1 0 0 1 2 0 Tel. Line Test Intervals Min. Ring Length Rings Time Out Minutes 10 ms Seconds (Max 99) (Max 20) (4 to 25) 094 095 096 0 0 1 5 0 6 Note address 091: The download is ENABLED by default. Setting 21 at address 091 disable modem (because 21 rings for modem not accepted by telephone net). To ENABLE enter 01 to 20 at address 091. For Instant Modem Answer (Answer Now): Enter 01 in address 092, hold-down key 6 then hold-down key 1, A displayed in confirmation. For special application, address 093 set the ring detector pulse width. SET USER CODES: Address 099 provides setting of user codes 1 to 8. SET FACTORY DEFAULT: In address 200 enter 6 9, program will revert to factory default programming 18

COMMUNICATOR PARAMETERS TELE Receiver Reserved Handshake Data Protocol Sum Transmit Inter MSG Wait for PHONE Format Check Format Frequency Type (Parity) Rounds Time Handshake No. 2 201 203 205 207 209 211 213 215 0 0 0 2 0 0 0 0 0 0 0 0 3 0 2 0 TELE PHONE Receiver Handshake Data Format Protocol Sum Check Transmit Inter MSG Wait for Format Reserved Frequency Type (Parity) Rounds Time Handshake No. 3 202 204 206 208 210 212 214 216 0 0 0 2 0 0 0 0 0 0 0 0 3 0 2 0 00 - Dialer only (No Communicator) 00=1400 Hz 00=3 X 1 00=Standard 00=None 00=2 Rnd 00=0.1 Sec XX=Sec's 01 - Ademco, Silent Knight Slow, Scantronic 01=2300 Hz 01=4 X 1 01=Extend 01=S.Check 01=1 Rnd 30=3 Sec 02 - Radionics Fast 03 - Sescoa, Vertex, DCI, Franklin 02=Hi/Lo 02=4 X 2 3 Sec's is 04 - Silent Knight Fast Ademco H.S. Default 05 - Radionics, DCI, Franklin Slow SurGurd Rec. 03=3 X 2 06 - Universal High Speed set 00 or 01 07 - Contact ID or Ademco High Speed * 00 - No Communicator, is identical to Dialer that generates sound upon alarm. * Contact ID and Ademco H.S. are available at panels version 2.06 or higher. Rnd is shortening for ROUNDS. S. Check is shorting for Sum Check. Hz is shorting for Hertz (frequency unit). When Contact ID selected program only Group 1 Subscriber ID at address 360 and 364. REPORT SELECTION For communicator codes A to F, enter the following: A=10, B=11, C=12, D=13, E=14, F=15. Note: entering 0 0, is same as a blank. Group 1 Group 2 Report on Alarm 105 Report on Alarm 106 1 2 3 4 ZONE AC LB PA 1 2 3 4 VALUE 1 2 3 Zone Restore 107 Control Panel Restore 108 1 2 3 4 ZONE AC LB PA 1 2 3 4 VALUE 1 2 3 Report Bypassed Zones 109 1 2 3 4 ZONE 1 2 3 4 VALUE ALARM, RESTORE, BYPASS ZONES, OPENING / CLOSING, SIGNAL TEST & FORCE OPENING CODES Group 1 Group 2 Alarm Codes - Single Codes Alarm Codes - Single Codes 1 2 3 4 Z O N E S AC LB PA (Alarm Code for Fire = 1) 110 112 114 116 126 128 130 3 3 3 3 CODES F F 2 111 113 115 117 127 129 131 1 2 3 4 CODES 9 8 1 Alarm Codes - Extended or 2 Digits Alarm Codes - Extended or 2 Digits 19

Restore Codes - Single Codes Restore Codes - Single Codes 1 2 3 4 Z O N E S AC LB PA 142 144 146 148 158 160 162 E E E E CODES E E E 143 145 147 149 159 161 163 1 2 3 4 CODES 9 B A Restore Codes - Extended or 2 Digits Restore Codes - Extended or 2 Digits Bypassed Zones Codes - Single Codes 1 2 3 4 Z O N E S Reserved 174 176 178 180 8 8 8 8 CODES 175 177 179 181 1 2 3 4 CODES Bypassed Zones - Extended or 2 Digits Closing (Arming) Codes-Single Digit Opening (Disarming) Codes-Single Digit Single Digit 1 2 3 4 Test USER 1 2 3 4 Test Force Opening 220 222 224 226 236 238 240 242 244 254 256 C C C C A CODE B B B B D 221 223 225 227 237 239 241 243 245 255 257 1 2 3 4 9 CODE 1 2 3 4 9 Closing Codes - Extended or 2 Digits Opening Codes - Extended or 2 Digits In order to disable reporting Closing/Opening change program at address 072; remove value 3. When SIGNAL TEST is enabled, you can specify to report System Status (as default for Extended or 2 digits) by programming for example A (Armed) at 236, and D (Disarmed) at 254, 9 is the test signal code. For System Status report, select extended or two digits format. For programming the End-User codes 1 to 8 (Arm/Disarm code) via installer programming mode, enter to address No. 099, then program new codes by first entering the code index (1,2,3..). For Force Opening Code (Ambush) the user should enter the Disarming code in reverse order. TEL. 2 - SUBSCRIBER ID NUMBER Note: For subscriber ID that contains a 0 (zero), enter 10 in place of 0. 0 will be displayed as A. Do not enter 0 0. Group 1 Group 2 Alarm / Restore ID Alarm / Restore ID Open. / Closing ID 260 261 262 263 268 269 270 271 276 277 278 279 To easily program the subscriber ID number, as a sequence of 4 digits use the EASY Program. Even if your code is 3 digits only you must enter 4 digits, the 4th digit can be any digit and the system will disregard the 4th digit. EASY Program EASY Program EASY Program Alarm / Restore ID Alarm / Restore ID Open. / Closing ID 360 368 376 20

TEL. 3 - SUBSCRIBER ID NUMBER Group 1 Group 2 Alarm / Restore ID Alarm / Restore ID Open. / Closing ID 264 265 266 267 272 273 274 275 280 281 282 283 EASY Program EASY Program EASY Program Alarm / Restore ID Alarm / Restore ID Open. / Closing ID 364 372 380 To easily program the subscriber ID number, as a sequence of 4 digits use the EASY Program. Even if your code is 3 digits only you must enter 4 digits, the 4th digit can be any digit and the system will disregard the 4th digit. Values beneath addresses are default programming. 1 Auto Bypass is applicable to Instant (Non-Delayed or Non-Follower) zones only. 18. ENTERING INSTALLER (ENGINEER) PROGRAMMING MODE Easy Tip: You may program any address by entering the address then the value in sequence. Power up by connecting AC power with or without battery. Program 1. Hold down keypad key 8 (hold-down function). 2. While the four LEDs are blinking, enter programming code ( 1 9 9 4 ): Siren 1 Reset 9 9 Delay Reset 4 Delete. 3. If the code is valid, P will be displayed. The two left LED's (Red & Green) blink to indicate that system is waiting for a new programming address number. 4. Enter address to be programmed (see programming sheet). Current value of address will be displayed, and LEDs will blink. Note: Blinking of 2 left most LEDs, means system is waiting for new address to be entered; Enter a 3 or 2-digit address (according to address length.) Note: 3 blinking LEDs means system is waiting for new value to be entered; Enter a 2-digit value, or as required. EXAMPLE 1: P is displayed and two left-most LEDs are blinking. 1. Program zones 1 and 4 as Exit/Entry Delayed 1 (zone type). 2. Address 021 represents the Exit/Entry Delayed 1 zones. 3. Press 0 0 Display 2 Siren 1 ; current value of this address is 1 (default program.) Three LEDs will blink and a 1 will be displayed (default program). 4. To enter new required value press the address number 0 Display 2 Siren 1 then the new Delay required value ( 1 and 4 ) by pressing Siren 1 Delete 4 in uninterrupted sequence; U confirms programming updating. 6. P is displayed, two left-most LEDs are blinking. 21

EXAMPLE 2: 1. To program zone 4 as 24H zone (in default program, this is an Instant Zone). 2. Address 024 represents the 24H zones Delay 3. Press 0 Display 2 Delete 4 ; current value of the address is - ( - means blank - no 24H zone is programmed). Three LEDs will blink and an - will be displayed (default program). Delay 4. To enter new required value press the address number 0 Display 2 Delete 4 then enter new value 8, by pressing Delay Delete 4 (zone 4). U confirms programming updating. 5. P is displayed; two left-most LEDs are blinking. Note: To delete a programmed feature, enter 0 at feature s address EXAMPLE 3: 1. To program zone 1 to 4 as Fast Response Zone. 2. Address 032 represents Fast Response Zone. 3. Press 0 Status 3 Display 2 ; current value of the address is blank; three LEDs will blink and - will be displayed (- means blank; no Fast Response Zone is default program). 4. To Enter new required value press the address number 0 Status 3 Display 2 then enter new value 1 2 3 4 by pressing 1 Delay Siren Display 2 Status 3 Delete 4. U confirms programming updating. 5. P is displayed, two left-most LEDs are blinking. 19. RESET SYSTEM TO DEFAULT PROGRAMMING Warning! This function erases all codes and system programming settings. 1. Enter program mode. 2. Go to address 200 and enter 6 and 9. Display will show E P R, and system will revert to factory default program. Code No. 1 is 1 2 3 4; programming code will be 1 9 9 4. Quitting and Updating new Programming via AV-701 Keypad Upon programming completion, hold down key Reset 9. Wait for a long beep, and then release the key. When P is no longer displayed, the system has reverted to Disarmed mode. Note: The system disregards erroneous or conflicting programming features upon quitting program mode. For example: Programming the same zone as 24H type and delayed zone, considered as 24H zone. Reset System to Default Codes This feature is enabled by default, to disable remove the 8 in address 072. By holding-down keys * # Keypad Panic during power-on (by applying AC and Battery), after 2 nd beep release keys, U will be display 3 times in confirmation. User code No. 1 (1234) and programming code (1994) will reset to default. 22

20. ANSWERING MACHINE BYPASS In case the alarm panel connected with fax or answering machine on the same telephone line (not recommended) enable the Answering Machine Bypass or Answer Now features (otherwise connection is impossible). To enable the feature: 1. Program 7 at address 074 2. Program at least 24 seconds at address 096 (Ring Time Out) Now dial to the control panel, count at least three rings and disconnect, dial again after 10 seconds the panel will answer at first ring. When Answering Machine Bypass enabled, the control panel will answer at first ring if: - There was a pause of at least 10 seconds from last ring - The panel already counted at least three rings before the pause - Number of rings to answer (at address 091) is less than 20 Notice: The panel will answer (in a normal mode) if there is no pause and the rings counted exceed (or equal) the number programmed at 091. 21. TELEPHONE LINE TEST Software Telephone Line Monitor (test), address 094: Time interval between telephone line tests - in hours. Range between 00-24. When 00 programmed no test performed. Failure to get a dial tone when dialing will cause a "Phone Line Fault" event. 22. ID CODES FOR COMMUNICATOR - EASY PROGRAMMING Refer to programming table, part 10; System is in program mode, enter ID address, 4 LEDs are blinking, enter the subscriber ID code in sequence. Example: Your subscriber ID number is 2170 for Closing/Opening of telephone 1; refer to address number 376. Keypad in programming mode, P is displayed, press 376, 4 LEDs are blinking, enter 2170. Note: Even if your communicator receiver requires three digits for the subscriber ID, enter four digits. The system will ignore the fourth digit automatically If your central station that requires programming of letters as well as numbers, please refer to the HEX programming description. Use the regular programming method of entering each letter or number in each address, as explained in the programming table (HEX method). Note: EASY Programming is not included in the EasyLoad screen (programming via computer). 23