INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS

Similar documents
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

High Profile Evaporator

Installation, Operation, and Maintenance Information

Condensing Unit Installation and Operating Instructions

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

KR Electrical Defrost Unit Coolers (PN E108318_E)

Condensing Unit Installation and Operating Instructions

KTL Two-Way Low Profile Evaporators

KR Series Air Defrost Unit Coolers Operating and Installation Manual

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Half Round Evaporators

REFRIGERATION KOOL-AIR INC. DIRECT DRIVE AIR COOLED CONDENSERS AND HEAT RECOVERY UNITS

SM/SV-Space Master Unit Coolers (E R.0)

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

ThermoSaver TM Hot Gas Defrost System

LOW PROFILE UNIT COOLER

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

T-Series Air Conditioner T15 Model

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

STC Series Twin Unit Coolers (E329630_A)

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WALK-IN COOLERS SERIES LS-LP-LA-LV

ThermoSaver TM Hot Gas Defrost System

T-Series Air Conditioner T20 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

TLV Low Velocity Evaporators

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T53 Model

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

Center Mount Unit Coolers

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

Drop-In Refrigeration System

DT/DTX Series Unit Coolers (R0 E316013)

COMMERCIAL AIR COOLERS AIR, ELECTRIC AND HOTGAS DEFROST

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

Low Profile Unit Coolers

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

SM/SV Series Space Master Unit Coolers Operating and Installation Manual

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Service Step by Step Trouble-Shooting Check-List

KTL Two-Way Low Profile Unit Coolers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

BTL Two-Way Low Profile Evaporators

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

TEMPERATURE & PRESSURE CONTROLS

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

RPI Industries, Inc.

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

A Complete Line Of Remote Rack Refrigeration Systems

Horizontal Bottle Cooler Installation and Operation Manual

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Installation and Operation Guide For

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

START UP FORM PACKET

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Kolpak/RDI Refrigeration System Installation & Operation Manual

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

horizontal air discharge outdoor discus condensing unit

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

Solid Door Top Mount Reach-In Freezer

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

SXY MAINTENANCE SECTION M-1

Low Profile Unit Coolers

Chef Base Refrigerators

AIR CONDITIONER ELECTRONIC CONTROL

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS SERIES MPA, HPA SERIES MPE, HPE & JPE SERIES MPG, HPG & JPG SERIES MPH, HPH & JPH AIR DEFROST APPLICATION ELECTRIC DEFROST APPLICATION REVERSE CYCLE HOT GAS DEFROST THREE PIPES HOT GAS DEFROST

WARNING: ELECTRICAL POWER MUST BE SWITCHED OFF/DISCONNECTED BEFORE STARTING ANY SERVICE WORK ON UNITS. RECEIVING & INSPECTION You have purchased one of the best units available today in the market with unique features. Congratulations and thank you for using Kool-Air. Upon receipt of shipment, please inspect the unit immediately and notify and file a claim with the transport if there is any damage. Our shipment is thoroughly inspected before it is handed over to the transport driver. Location & Installation The unit can be flush mounted against the ceiling or suspended from the ceiling. Suspended units must have space above to clean the top of the unit. To ensure uniform air distribution throughout the cooler a location should be chosen so that the air flow from the unit (both entering and leaving) is unrestricted. Also to create air curtain effect, blow cold air towards the door of the cooler. This unit draws air in from the coil and discharge cold air through the fan. The horizontal throw of the MP unit is from 40 to 50 feets and for the HP & JP from 50 to 65 feets. The unit must have space equal to the height of the unit between the coil and the wall for air movement. For MPE, HPE & JPE models, heaters are embedded into die-formed fin slots in the face of the coil and therefore no space on the side is necessary for heater removal. (The air throw shown is for optimum conditions, it can be affected by the room height and the products loading.) 2

Wiring All wiring must be done in accordance with national and local electrical codes. All internal wiring of the unit is done at our factory and all wiring connections terminate at the terminal block. The power supply must match with the name plate requirement. The unit cabinet must be grounded. On applications where total heater amperage exceeds 40 amps the heaters must be wired through a separate contactor, which should be located outside the cooler. Refer to the wiring diagram which is supplied with the unit for full details. Drain Line MP series units have ¾ inch MPT drain connection, whereas the HP, JP series units have 1 ¼ inch connection. The drain line should be pitched sharply and exit the cooler/freezer on the shortest run as possible. The drain line should be insulated and if the cooler temperature is below 32 F drain line heaters (approx. 15 watts per foot of drain line) may be required. Do not overlap the drain heaters. Provide drain trap outside the cooler/freezer in a warm area. Also a union in the drain line is preferred for ease of installation and service. Refrigerant Connections / Piping All refrigerant piping and connections must be installed in accordance with local and national codes. Lines should be sized in accordance with the latest A.S.H.R.A.E. Standards. Suction line trap(s) should be provided and suction line should be pitched downward toward the compressor to prevent slugging and to ensure oil return to compressor. Make sure the system is completely clean and dry. Evacuate the entire system after it has been purged and leak tested, before charging it with refrigerant. Expansion Valve 3

All units use externally equalized TX valves and are provided with an equalizer line connection. All units liquid line/tx valve connections are sweat connections. Selection of expansion valve is very important to get peak performance from the evaporator and to have a balanced system. Check superheat reading and adjust it to obtain full evaporator performance. Refer to expansion valve manufacturer s catalogue for full details. OPERATION MPA & HPA models are for Air-Defrost applications, where cooler temperature is +34 F. or above. The coil can be defrosted by switching the compressor off and just running the unit cooler fans. MPE, MPG, MPH, HPE, HPG, HPH, JPE, JPG & JPH models are for freezer applications down to -40 deg. F. MPE, HPE & JPE units are provided with high density stainless steel electric heaters and fan delay/defrost termination thermostat. Adjust defrost timer (45 minutes) to match the application and to ensure that the coil is completely defrosted after each defrost cycle. Defrost thermostat must terminate defrost cycle and fan delay thermostat must prevent moisture from being blown from the wet coil to the freezer at the termination of the defrost cycle. Time initiated temperature terminated defrost cycle is preferred to ensure clean coils at all times. Fan motor starts from the defrost thermostat. All fan motors are permanently lubricated and thermally protected. Fan motors may cycle due to thermal protection if the coil is blocked or iced up. MPG, MPH, HPG, HPH, JPG & JPH units are defrosted by the hot gas from the compressor discharge line. See piping diagram. A crankcase pressure regulating valve is recommended on low temperature applications. Also a suction accumulator with boil out coil or suction/liquid heat exchanger is recommended to avoid liquid slug to compressor. SYSTEM START-UP Before start-up: 4

1. All wiring should be in accordance with local codes. 2. Refrigerant should be adequately sized. 3. Liquid line solenoid should be installed on every system. 4. Complete evacuation and system dehydration has been done. 5. All valves must be open.(suction, discharge, receiver, etc.) 6. Make sure these components are installed: liquid line drier, moisture indicator and suction filter. 7. Pour water in the drain pan to check if it s sealed correctly and if the drainage is adequate. After start-up: 1. If necessary by-pass fans delay control until the room temperature is lowered. 2. Check oil level. 3. Make sure the expansion valve is set correctly to provide good amount of superheat. (Around 5 to 6 8F for 10 8FTD) 4. When starting up the system for the first time, moisture is usually encountered in the system. This will frost the coil rapidly if the coil temperature is below 32 8F. Watch the coil during the initial start-up and perform manual coil defrost if necessary. Repeat if required. 5. Check fans for proper rotation sense. MAINTENANCE 5

Periodically check the unit for any vibrations and dirt accumulation. Grease and dirt should be removed from the fans, fan guards and drain pan. The drain line should be checked and all foreign material removed. The finned surface may be cleaned using a whisk or fin brush. These are relatively maintenance free units as the motors are permanently lubricated and thermally protected. REPLACEMENT PARTS Use only manufacturer approved replacement parts. When ordering parts, please make sure you have the complete model number, serial number and voltage information. MOTOR MOTOR MOTOR MOTOR UNIT FAN FAN FAN GUARD DELAY MP(A,E,G,H)-18-02300 MP(A,E,G,H)-18-02900 MP(A,E,G,H)-18-03200 MP(A,E,G,H)-28-04570 MP(A,E,G,H)-28-05800 MP(A,E,G,H)-28-07000 MP(A,E,G,H)-38-07600 MP(A,E,G,H)-38-09750 MP(A,E,G,H)-48-10600 MP(A,E,G,H)-48-12500 M0028 M0027 M0025 F0020 F2022 E-0004 NOTE: MPE OR MP(G,H) SERIES WITH ELECTRIC DEFROST IN THE PAN ARE N/A IN 208-230/1/60 MOTOR VOLTAGE MOTOR MOTOR MOTOR MOTOR UNIT FAN FAN FAN GUARD DELAY HP(A,E,G,H)-18-04500 HP(A,E,G,H)-18-05800 HP(A,E,G,H)-18-06400 HP(A,E,G,H)-28-09200 HP(A,E,G,H)-28-11600 HP(A,E,G,H)-28-13000 HP(A,E,G,H)-38-16000 HP(A,E,G,H)-38-19000 HP(A,E,G,H)-48-25200 N/A M0036 M0035 F0030 F2025 E-0004 6

UNIT JP(E,G,H)-16-04400 JP(E,G,H)-16-05800 JP(E,G,H)-16-06800 JP(E,G,H)-26-09100 JP(E,G,H)-26-11400 JP(E,G,H)-26-13200 JP(E,G,H)-36-16200 JP(E,G,H)-36-20600 JP(E,G,H)-46-27800 MOTOR MOTOR MOTOR MOTOR FAN FAN FAN GUARD DELAY N/A M0046 M0045 F0031 F2025 E-0004 UNIT MPA-18-02300 MPA-18-02900 MPA-18-03200 MPA-28-04570 MPA-28-05800 MPA-28-07000 MPA-38-07600 MPA-38-09750 MPA-48-10600 MPA-48-12500 HEATER HEATER HEATER HEATER TERMINAL BOARD N/A E-0003 UNIT MP(E,G,H)-16-02100 MP(E,G,H)-16-02700 MP(E,G,H)-16-03000 MP(E,G,H)-26-04250 MP(E,G,H)-26-05600 MP(E,G,H)-26-06600 MP(E,G,H)-36-07350 MP(E,G,H)-36-09400 MP(E,G,H)-46-10000 MP(E,G,H)-46-12000 HEATER HEATER HEATER HEATER H-0050 H-0080 H-0055 H-0085 H-0060 H-0090 H-0065 H-0095 TERMINAL BOARD E-0003 7

UNIT HPA-18-04500 HPA-18-05800 HPA-18-06400 HPA-28-09200 HPA-28-11600 HPA-28-13000 HPA-38-16000 HPA-38-19000 HPA-48-25200 HEATER HEATER HEATER HEATER TERMINAL BOARD N/A E-0003 UNIT HP(E,G,H)-16-04000 HP(E,G,H)-16-05150 HP(E,G,H)-16-06000 HP(E,G,H)-26-08200 HP(E,G,H)-26-10200 HP(E,G,H)-26-12400 HP(E,G,H)-36-14000 HP(E,G,H)-36-18200 HP(E,G,H)-46-24400 HEATER HEATER HEATER HEATER H-0080 N/A H-0085 H-0090 H-0095 TERMINAL BOARD E-0003 UNIT JP(E,G,H)-16-04400 JP(E,G,H)-16-05800 JP(E,G,H)-16-06800 JP(E,G,H)-26-09100 JP(E,G,H)-26-11400 JP(E,G,H)-26-13200 JP(E,G,H)-36-16200 JP(E,G,H)-36-20600 JP(E,G,H)-46-27800 HEATER HEATER HEATER HEATER H-0080 N/A H-0085 H-0090 H-0095 TERMINAL BOARD E-0003 8

ELECTRICALS (Wiring Diagrams) MPA & HPA Air Defrost MPE, HPE & JPE Electric Defrost 9

MP, HP & JP (GE, HE) Reverse cycle hot gas defrost & 3 pipes defrost whit electric defrost in drain pan. MP, HP & JP (GL, HL) Reverse cycle hot gas defrost & 3 pipes defrost whit hot gas loop in drain pan. 10

PIPING LAYOUT (Piping Diagrams) MP, HP & JP (GE) Reverse cycle hot gas defrost whit electric defrost in drain pan. MP, HP & JP (HE) Three pipes hot gas defrost whit electric defrost in drain pan. 11

MP, HP & JP (GL) Reverse cycle hot gas defrost whit hot gas loop in drain pan. 12

MP, HP & JP (HL) Three pipes hot gas defrost whit hot gas loop in drain pan. 13

HEAD OFFICE: REFRIGERATION KOOL-AIR INC. Québec, Canada Tel: (450) 632-5775 Fax: (450) 632-7412 Due to Kool-Air policies to continuously improve the quality of its products, specifications are subject to change without notice. 14