technical data air conditioning systems Indoor Units FBQ-C7VEB

Similar documents
Air Conditioners. Technical Data FBQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioners. Technical Data FTXS-G

EEDEN technical data ERHQ AA. Altherma. Altherma

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

for the retail market, hotels, restaurants and offices

TABLE OF CONTENTS RMXS-E8V1B

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

TABLE OF CONTENTS ERSQ-AAY1

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

Daikin air conditioners for your home, shops, restaurants and offices

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioning Technical Data RZAG-MV1

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioners Technical Data

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioners Technical Data

Heating. Technical Data EEDEN ERRQ-AY1

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

EEDEN technical data EKRTR. Altherma. Altherma

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioners. Technical Data FTY-H

Air Conditioners Technical Data

Air Conditioning Technical Data RZASG-MV1

for small rooms in multi application

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioners Technical Data

Air Conditioners Heating & Cooling

AIR CONDITIONERS, HEATING & COOLING for your home

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data EEDEN RXS-F8

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Air Conditioners Technical Data

Remote control infrared ARC433B76 ARC433A8 ARC433B69

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Purifiers. Technical Data MC70L

TABLE OF CONTENTS ERHQ BAV3

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioners Heating & Cooling

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

for your home FTYN-GX FT(Y)N-F

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioners Heating & Cooling

Daikin leads the way:

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

w w w. d a i k i n. e u ATXS-E

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Daikin air conditioners for shops, restaurant and offices

Air Conditioning Technical Data AZAS-MY1

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Air Conditioners Heating & Cooling

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

BENEFIT FROM LOWER FUEL COSTS.

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Commercial and Technical Data

Air Conditioners Heating & Cooling

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Chillers. Technical Data. EWYD-BZ 250~580 kw

Air Conditioners Heating & Cooling

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Daikin air conditioners for your home

EEDEN technical data ERHQ AA

Daikin air conditioners for your home

Concealed ceiling unit with medium ESP

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Transcription:

technical data Indoor Units FBQ-C7VEB air conditioning systems

technical data Indoor Units FBQ-C7VEB air conditioning systems

Indoor Units R-40A FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB Features............................................................. 2 2 Specifications....................................................... 3 For indoor units only................................................. 3 Technical Specifications............................................. 3 3 Safety device settings............................................. 5 4 Options.............................................................. 5 5 Dimensional drawing & centre of gravity........................ 7 Dimensional drawing................................................. 7 Centre of gravity.................................................... 0 6 Piping diagram..................................................... 7 Wiring diagram..................................................... 2 Wiring diagram...................................................... 2 8 Sound data......................................................... 3 Sound pressure spectrum........................................... 3 Sound power spectrum............................................. 5 9 Fan characteristics................................................ 7 0 Installation.......................................................... 20 Installation method.................................................. 20 Filter installation method............................................ 2 Switch box connection.............................................. 22 Split Sky Air Indoor Units

t i y n k r 7t o 0 i o - ld 4 np - FI Indoor Units R-40A FBQ-C7VEB Features BU S E V a C Q B RS Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3-step airflow control Maximum external static pressure (ESP) is 00Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Energy efficient: up to class A energy labels Home leave operation saves energy during absence Whisper quiet operation: down to 26 dba sound pressure level Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Easy installation thanks to automatic air flow adjustment towards nominal air flow rate Built-in drain pump as standard increases reliability of the drain system optional standard 3 steps via wired remote control optional 2 Split Sky Air Indoor Units

2 Specifications Indoor Units R-40A FBQ-C7VEB 2- For indoor units only FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ7C7VEB FBQ00C7VEB FBQ25C7VEB FBQ40C7VEB Nominal input (Indoor only) Cooling kw 0.4 0.4 0.35 0.35 0.35 0.35 0.35 Heating kw 0.4 0.4 0.35 0.35 0.35 0.35 0.35 2-2 Technical Specifications FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ7C7VEB FBQ00C7VEB FBQ25C7VEB FBQ40C7VEB Casing Colour Non painted Material Galvanised steel Dimensions Packing Height mm 355 355 355 355 355 355 355 Width mm 920 920,220,220,620,620,620 Depth mm 900 900 900 900 900 900 900 Unit Height mm 300 300 300 300 300 300 300 Width mm 700 700,000,000,400,400,400 Depth mm 700 700 700 700 700 700 700 Weight Unit kg 25 25 34 34 45 45 45 Packed Unit kg 28 28 4 4 53 53 53 Required Ceiling Void mm >350 Heat Exchanger Dimensions Length mm 440 440 740 740,40,40,40 Nr of Rows 3 3 3 3 3 3 3 Fin Pitch mm.75.75.75.75.75.75.75 Nr of Passes 4 4 7 7 Face Area m² 0.48 0.48 0.249 0.249 0.383 0.383 0.383 Nr of Stages 6 6 6 6 6 6 6 Tube type Hi-XSS (7) Fin Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Sirocco fan Quantity 2 2 3 3 3 Air Flow Rate Cooling High m³/min 6 6 8 8 32 39 39 Low m³/min 5 5 23 28 28 Heating High m³/min 6 6 8 8 32 39 4 Low m³/min 5 5 23 28 29 Fan Max High Pa 00 00 00 00 00 00 00 Standard Pa 30 30 30 30 40 50 50 Motor Quantity Model Brushless DC Number of steps 0 0 8 8 9 9 9 Motor Speed (cooling) High rpm,86,86 942 942,060,28,28 Low rpm 875 875 823 823 83 920 920 Speed (heating) High rpm,86,86 942 942,060,28,280 Low rpm 875 875 823 823 83 920 967 Fan Motor Output (high) W 40 40 350 350 350 350 350 Drive Direct drive Cooling Sound Power High dba 63 63 57 57 6 66 66 Sound Pressure High dba 37 37 37 37 38 40 40 Low dba 29 29 29 29 32 33 33 Heating Sound Pressure High dba 37 37 37 37 38 40 4 Low dba 29 29 29 29 32 33 34 Refrigerant Type R-40A Piping connections Liquid (OD) Type Flare connection Diameter (OD) mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 Gas Type Flare connection Diameter (OD) mm 9.52 2.7 2.7 5.9 5.9 5.9 5.9 Drain Diameter (OD) mm VP25 (O.D. 32 / I.D. 25) Heat Insulation Both liquid and gas pipes Drain-up Height mm 625 625 625 625 625 625 625 3 2 Split Sky Air Indoor Units 3

2 Specifications Indoor Units R-40A FBQ-C7VEB 2 2-2 Technical Specifications FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ7C7VEB FBQ00C7VEB FBQ25C7VEB FBQ40C7VEB Decoration Panel Model BYBS45DJW BYBS45DJW BYBS7DJW BYBS7DJW BYBS25DJW BYBS25DJW BYBS25DJW Colour White (0Y9/0,5) Dimensions H mm 55 55 55 55 55 55 55 W mm 800 800,00,00,500,500,500 D mm 500 500 500 500 500 500 500 Weight kg 3.5 3.5 4.5 4.5 6.5 6.5 6.5 Air Filter Resin net with mold resistance Safety Devices PC board fuse PC board fuse (fan driver) Drain pump fuse Notes Nominal cooling capacities are based on : indoor temperature : 27 CDB, 9 CWB, outdoor temperature : 35 CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction Remote Control Wired BRCD528 4 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 3 Safety device settings Safety devices 35 50 60 7 00 25 40 PC Board Fuse 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A PC Board Fuse (Fan Driver) 250V 5A 250V 5A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A FBQ Fan Motor Thermal Protector C Drain Pump Fuse C 45 45 45 45 45 45 45 4 Options 3 3 FBQ35-40C Options Item Type FBQ35 FBQ50 FBQ60,7 FBQ00,25,40 Panel related Decoration panel BYBS45D BYBS7D BYBS25D Air inlet and air discharge outlet related Air discharge adapter for round duct KDAJ25K56A KDAJ25KA7A KDAJ25KA40A Operation Control Item Type FBQ35 FBQ50 FBQ60,7 FBQ00,25,40 Remote Control Wired Type BRCD528 Option BCB for external el. heater, humidifier and/or hour meter (*), (*3) EKRPB2A Adapter for wiring (interlock for fresh air intake fan) (*3) KRPBA54 Wiring adapter for electrical appendices (*3) KRP4A5 Central remote control DCS302CA5 Unified ON/OFF control DCS30BA5 Schedule timer DST30BA5 Interface adapter for sky air series DTA2BA5 Remote ON/OFF and FORCED OFF kit EKRORO3 Mounting plate for adapter PCB KRP4A96 (*): Electrical heater and humidifier are field supply. These parts should not be installed inside the equipment (refer to installation manual EKRPB2A) (*2): If installing an electrical heater, an option PCB for external heater (EKRPB2) for each indoor unit is required. (*3): Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB s can be mounted. Contents of accessory bag Description Quantity FBQ35,50,60,7,00,25,40 Hexagon tapping screw (M5x6) 6 Round plain washer for wood 8 Installation and operation manual Hose band Insulation for joint (GAS) Insulation for joint (LIQUID) Drain hose Drain hose sealing material Sealing material 2 3TW3279-3A Split Sky Air Indoor Units 5

Indoor Units R-40A FBQ-C7VEB 4 Options EKRORO3 4 Wire specifications Terminal X2M Screw to control box replacing the original terminal Connector (White) connect to indoor PCB (X30A) Operating method unit INPUT T,T2Switch Off Remote controller Standard setting: forced off Alternative setting: on/off On On Off On Off On Off Input ON = closed contact. Forced off Input on stops operation + disables control Input off enables control On/off operation Input off on: starts operation, remote control is still enabled. Input on off: stops operation, remote control is still enabled. Selection of FORCED OFF and ON/OFF operation Setting Mode No. First code NO Second code NO Forced off 0 2 (22) On/off operation 02 3TW360-6 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5 - Dimensional drawing FBQ35C View A-A Detail B Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing 3 5 suspension bolt or more (service space) or more (service space) Detail B (suspension position) (suspension position) Item Name Description Liquid pipe connection Ø6.35 flare connection 2 Gas pipe connection Ø9.52 flare connection 3 Drain pipe connection VP25 (OD Ø32, ID Ø25) 4 Remote control wiring connection - 5 Power supply connection - 6 Drain hole VP25 (OD Ø32, ID Ø25) 7 Air filter - 8 Air suction side - 9 Air discharge side - 0 Nameplate - 3TW3274- FBQ50C View A-A Detail B Suspension bolt 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description Liquid pipe connection ø 6.35 flare (connection) 2 Gas pipe connection ø 2.70 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 0 Nameplate NOTE Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW324- Split Sky Air Indoor Units 7

Indoor Units R-40A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5 - Dimensional drawing FBQ60C 5 View A-A Detail B Suspension bolt 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description Liquid pipe connection ø 6.35 flare (connection) 2 Gas pipe connection ø 2.70 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 0 Nameplate NOTE Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW3294- FBQ7C View A-A Detail B Suspension bolt 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description Liquid pipe connection ø 9.52 flare (connection) 2 Gas pipe connection ø 5.90 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 0 Nameplate NOTE Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW3234-8 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5 - Dimensional drawing FBQ00-40C 3 View A-A Detail B 5 Suspension bolt 350 or more (Service space) or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description Liquid pipe connection ø 9.52 flare (connection) 2 Gas pipe connection ø 5.90 (flare connection) 3 Drain pipe connection VP25 (O.D. ø 32 /I.D. ø 25) 4 Remote control wiring connection 5 Power supply connection 6 Drain hole VP25 (OD ø 32 /I.D. ø 25) 7 Air filter 8 Air suction side 9 Air discharge side 0 Nameplate NOTE Refer to outlook drawing for installing optional accessories when installing optional accessories. 2 The required ceiling depth varies according to the configuration of the specific system. 3 For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the filter installation method drawing. 3TW3254- Split Sky Air Indoor Units 9

Indoor Units R-40A FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity FBQ35-40C 5 MODEL A B FBQ35,50 283 700 FBQ60,7 44 000 FBQ00~40 69 400 4TW389-A 0 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 6 Piping diagram FBQ35-40C 3 Heat exchanger Refrigerant flow Cooling Heating 6 Refrigerant pipe connection port diameters Model Gas Liquid FBQ35C 9.52 6.35 FBQ50C 2.70 6.35 FBQ60C 2.70 6.35 FBQ7C 5.90 9.52 FBQ00C 5.90 9.52 FBQ25C 5.90 9.52 FBQ40C 5.90 9.52 Liquid pipe connection port Gas pipe connection port 3TW3275- Split Sky Air Indoor Units

7 Wiring diagram 7 - Wiring diagram Indoor Units R-40A FBQ-C7VEB 7 FBQ35-50C7VEB N~220-240V 50Hz N~220V 60Hz indoor Transmission wiring central remote control note 2 BLU : Blue wired remote control BRN : Brown (optional accessory) GRY : Gray Common ORG : Orange power supply PNK : Pink note 4 RED : Red WHT : White YLW : Yellow GRN : Green Switch box (indoor) Indoor unit MF Motor (fan) SS Selector switch (emergency) TC Signal transmission circuit AP Printed circuit board MP Motor (drain pump) SL Float switch Connector optional accessory A2P Printed circuit board (fan) PS Switching power supply VR Diode bridge X28A Connector (Power supply for wiring) C Capacitor QDI Earth leak detector V2R Power module X33A Connector (for wiring) FU, F2U Fuse (T, 5A, 250V) R Resistor (current limiting) XM Terminal strip (power supply) X35A Connector (adapter) F4U Fuse (T, 6.3A, 250V) R2 Current sensing device X2M Terminal strip (control) X85A Connector (for multi zoning) HAP Light emitting diode (Service monitor green) RT Thermistor (suction air) ZC Noise filter (ferrite core) X33A Connector (for wiring) KPR, KR Magnetic relay R2T Thermistor (liquid) ZF Noise filter Wired remote control LR Reactor R3T Thermistor (gas) RC Signal receiver circuit SS Selector switch (emergency) norm.emg, L N : Field wiring : Live : Neutral : Connector : Wire clamp : Protective earth (screw) Colors BLK : Black 2TW3276-A Use copper conductors only. 2 When using the central remote controller, see manual for connection to the unit. 3 The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. 4 Refer to installation manual. FBQ60-40C7VEB N~220-240V 50Hz N~220V 60Hz BLU : Blue Wired remote control BRN : Brown (optional accessory) GRY : Gray Common ORG : Orange power supply PNK : Pink note 4 RED : Red WHT : White YLW : Yellow GRN : Green Switch box (indoor) Indoor unit LR Reactor R3T Thermistor (gas) TC Terminal strip (control) AP Printed circuit board MF Motor (fan) R5T Thermistor NTC (Current limiting) YE Electronic expansion valve A2P Printed circuit board (fan) MP Motor (drain pump) SS Selector switch (emergency) Connector optional accessory A3P Printed circuit board (capacitor) PS Switching power supply SL Float switch X33A Connector (for wiring) C, C2, C3 Capacitor QDI Earth leak detector VR Diode bridge X35A Connector (adapter) FU Fuse (T, 5A, 250V) R2 Current sensing device V2R Power module X38A Connector (for wiring) F3U Fuse (T, 6.3A, 250V) R3, R4 Resistor (electric discharge) ZC Noise filter (ferrite core) Wired remote control HAP Light emitting diode (service monitor green) RT Thermistor (suction air) ZF Noise filter RT Thermistor (air) KPR, KR Magnetic relay R2T Thermistor (liquid) RC Terminal strip (power supply) SS Selector switch (main/sub) only for 60 class Transmission wiring central remote control note 2 Use copper conductors only. 2 When using the central remote controller, see manual for connection to the unit. 3 The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. 4 Refer to installation manual. only for 60 class NORM. EMG, L N : Field wiring : Live : Neutral : Connector : Wire clamp : Protective earth (screw) Colors BLK : Black 2TW3296-A 2 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 8 Sound data 8 - Sound pressure spectrum FBQ35-50C Sound pressure level [db] FBQ60C Sound pressure level [db] 3 8 High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW327-2 High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW3297-2 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba= A-weighted sound pressure level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphone Suction Unit Discharge Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba= A-weighted sound pressure level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphone Suction Unit Discharge Microphone Microphone FBQ7C FBQ00C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW3297-2 3TW3257-2 Notes Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction.5m Unit Discharge 2m 2m.5m Microphone m Notes Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction Unit Discharge 2m 2m.5m Microphone m.5m Split Sky Air Indoor Units 3

8 Sound data Indoor Units R-40A FBQ-C7VEB 8 - Sound pressure spectrum FBQ25C FBQ40C 8 Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW3267-2 3TW3337-2 Notes Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction.5m Unit Discharge 2m 2m.5m Microphone m Notes Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dba = A-weighted sound power level. (A-scale according to IEC) 4 Reference acoustic pressures 0dB = 20μPa 5 Location of microphine Suction Unit Discharge 2m 2m.5m Microphone m.5m 4 Split Sky Air Indoor Units

Indoor Units R-40A FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ35-50C FBQ60C 3 Sound power level [db] Sound power level [db] 8 High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW327- High-tap Medium-tap Low-tap Octave band center frequency (Hz) 3TW3297- dba= A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6μW/m 2 3 Measured according to ISO 3744 dba= A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6μW/m 2 3 Measured according to ISO 3744 FBQ7C FBQ00C Sound pressure level [db] Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW3297-3TW3257- Notes dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6μW/m 2 3 Measured according to ISO 3744 Notes dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6μW/m 2 3 Measured according to ISO 3744 Split Sky Air Indoor Units 5

Indoor Units R-40A FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ25-40C 8 Sound pressure level [db] High-tap Medium-tap Low-tap Octave band center frequency [db] 3TW3267- Notes dba = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 0E-6μW/m 2 3 Measured according to ISO 3744 6 Split Sky Air Indoor Units

9 Fan characteristics Indoor Units R-40A FBQ-C7VEB FBQ35-50C 3 Upper limint of ESP (std ESP ) Upper limint of ESP (max ESP ) L (max ESP) L (std ESP) Fan characteristics () M (max ESP) M (std ESP) H (max ESP) H (std ESP) (std ESP) (max ESP) Upper limint of ESP L Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H 9 Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW328- FBQ60C Fan characteristics () Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (max ESP ) L (max ESP) Upper limint of ESP (std ESP ) M (max ESP) M (std ESP) H (max ESP) H (std ESP) (max ESP) Upper limint of ESP L Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H L (std ESP) (std ESP) Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW3298- Split Sky Air Indoor Units 7

9 Fan characteristics Indoor Units R-40A FBQ-C7VEB FBQ7C 9 Upper limit of ESP (max. ESP) L (max. ESP) Upper limit of ESP (std. ESP) M (max. ESP) Fan characteristics () Fan characteristics (3) (Airflow auto adjustment) M (std ESP) H (max. ESP) H (std ESP) (max. ESP) Upper limit of ESP L Upper limit of ESP by airflow auto adjustment M by airflow auto adjustment H L (std ESP) (std. ESP) Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW3298- FBQ00C Fan characteristics () Fan characteristics (3) (Airflow auto adjustment) L (max. ESP) Upper limit of ESP (std. ESP) L (std ESP) Upper limit of ESP (max. ESP) M (max. ESP) M (std ESP) H (max. ESP) H (std ESP) (max. ESP) (std. ESP) Upper limit of ESP L M Upper limit of ESP by airflow auto adjustment by airflow auto adjustment H Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW3258-8 Split Sky Air Indoor Units

9 Fan characteristics Indoor Units R-40A FBQ-C7VEB FBQ25C 3 Upper limit of ESP (std. ESP) L (max. ESP) Upper limit of ESP (max. ESP) L (std ESP) Fan characteristics () Fan characteristics (3) (Airflow auto adjustment) M (max. ESP) M (std ESP) H (max. ESP) H (std ESP) (std. ESP) (max. ESP) Upper limit of ESP L Upper limit of ESP by airflow auto adjustment M by airflow auto adjustment H 9 Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m³/min] Fan characteristics as shown ar in fan only mode. 2 ESP: External static pressure 3TW3268- FBQ40C Fan characteristics () Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (std ESP ) Upper limint of ESP (max ESP ) L (max ESP) L (std ESP) M (max ESP) M (std ESP) H (max ESP) H (std ESP) (std ESP) (max ESP) Upper limint of ESP L Upper limint of ESP by airflow auto adjustment M Upper limint of ESP by airflow auto adjustment H Airflow [m 3 /min] Airflow [m 3 /min] Fan characteristics (2) (Field setting with remote control) Range of available air flow rate (H) Airflow [m 3 /min] Fan characteristics as shown are in fan only mode. 2 ESP: External static pressure 3TW3268- Split Sky Air Indoor Units 9

0 Installation 0 - Installation method FBQ35-40C Indoor Units R-40A FBQ-C7VEB 0 Rear Suction Bottom Suction Ceiling return Ceiling return Drain pump up height Installation with duct Direct installation of inlet panel Wide variety of installation methods Number Description Main body 2 Air outlet duct Field supply 3 Inlet panel Optional accessory 4 Acces panel optional accessory 5 Air inlet duct Field supply Easy modification from rear to bottom suction 3TW383-20 Split Sky Air Indoor Units

0 Installation 0-2 Filter installation method FBQ35-40C Indoor Units R-40A FBQ-C7VEB (or less) 3 0 Installation without air inlet duct Installation with air inlet duct Nr. Description When installing the unit with rear Suspended Ceiling suction, a service opening is 2 Ceiling opening necessary for the maintenance of 3 Service access panel (optimal) the air filters. 4 Air filter 2 When installing the unit with a 5 Air inlet duct 6 Duct service opening suction duct. A service opening must be provided in the duct. 3TW384-4 Split Sky Air Indoor Units 2

0 Installation 0-3 Switch box connection Indoor Units R-40A FBQ-C7VEB FBQ35-40C 0 Emerg. Norm. Common power supply 3TW384-5 22 Split Sky Air Indoor Units

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intension to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikin.eu BTW: BE 042 20 336 RPR Oostende Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environmont is set in the EMAS and ISO 400 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende