US Navy Leading the Way in Switchboard Protection

Similar documents
SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

AQ 100 Series. Arc Flash Protection System

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Electrical Preventive Maintenance (EPM) Program

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

SECTION AUTOMATIC TRANSFER SWITCHES

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

Arc Fault Detection Devices (AFDDs) Protecting People and Property

DISTRIBUTION STATEMENT

Electrical Safety Compliance: NFPA 70E

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

PGR-8800 TECHNICAL FAQ

NFEC FIRE SAFETY SEMINAR Krish Mysore

Machinery Room Electrical Best Practices

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Gas ventilation monitoring and control system

How to reduce exposure to arc flash hazards

LEARNING SPECIAL HAZARD DETECTION TYPES

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Guide To Troubleshooting INEFFICIENT COOLING FANS

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

Volume Sensor Multi-sensor, Multi-criteria Event Detection

A Novel Approach for a Hostile Arms Fire Sensor

CHAPTER 20 SERVICE EQUIPMENT

DCS DSS OSS EIB OBPS OPTS FDS AFSS

NFPA 70E Electrical Safety & Arc Flash Training

DISTRIBUTION STATEMENT

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

Arc Fault - Minimize damage

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

D1000 Arc-fault Protection System

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

Technical News. Solutions to prevent overheating of critical switchgear. Specialists in electrical and automation products, systems and solutions

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

Operation and use. Functions and characteristics

Arc Fault Protection System D1000

Monitoring of Electrical Equipment Failure Indicators and Alarming

VAMP 120 & 121. Arc flash detection units. Product picture

IMPORTANT INSTRUCTIONS READ & SAVE

1.1.0 Protocols for the response to fires involving MRI Machines

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

IMPORTANT INSTRUCTIONS READ & SAVE

Speed and Frequency Seite 1 von 7

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

The safe way to verify the absence of voltage.

Operating Manual MS220KA and MSR220KA

PROTECTING AGAINST ARC FLASH HAZARDS

STRATEGIES FOR RELIABLE ARC FLASH DETECTION IN LOW- VOLTAGE SWITCHGEAR

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Product Guide Low Voltage Switchboard & Switchgear

PDF- VERSION ADJUSTED FROM THE BROCHURE. tissue. How to protect tissue mills from fire

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Installation Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

Electrical Safety Program

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Model 600 Operation & Maintenance Manual

Introduction Consultant shall incorporate the material in the DSS into the project specifications.

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments

Standards for MV switchgear rated for arc flash protection

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Installation Instructions

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

DISTRIBUTION OPERATIONS AND MAINTENANCE

Root Cause Analysis Report Tesoro Golden Eagle Refinery Refinery Power Outage

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Installation Instructions

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Installation Instructions

Lloyd s Register Type Approval System Test Specification Number 3

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Commissioning the Fire Suppression System for 500/230 kv Transformers of EGAT s Nongchok Substation

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Fieldbus Foundation TM Bus diagnostics and troubleshooting

Predictive Maintenance Training

AmpLight Lighting Management System

EKA EKA NI EKA NIS EKA NV EKA NV PH EKA NV PTC/PS

VAMP 121. Arc protection unit. User manual

EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC/PS

Transcription:

US Navy Leading the Way in Switchboard Protection Rick Kurek Naval Sea Systems Command (NAVSEA) 2341 Jefferson Davis Highway Arlington, VA 22202 Ph: 202-781-1274 rick.kurek@navy.mil Abstract According to the National Fire Protection Association (NFPA), an arc flash is defined as "a dangerous condition associated with the release of energy caused by an electric arc." An arc is a high-impedance discharge of electricity through the air that causes light and heat. The temperature of an arc can reach up to 6000 degrees C. Most switchboard components can only withstand these temperatures for about 0.25 seconds before sustaining damage. Arcing Faults can cause damage to power distribution systems since the inherent operational characteristics of the circuit breakers may not isolate the affected conductors for several seconds due to the relatively low current levels identified with this type of fault. This paper will discuss how the US Navy is leading the way in Arc Fault Detection (AFD) Technology and has teamed up with Johns Hopkins APL to develop AFD Systems designed to detect and extinguish high resistance arcing faults. Use of these systems has significantly reduced, if not eliminated any significant damage, from Arc Faults in switchboards and load centers protected by AFD Systems. Discussion The CTM feature can detect overheated connections and give a warning before they become an arc. Arcing Faults can cause damage to power distribution systems since the inherent operational characteristics of the circuit breakers may not isolate the affected conductors for several seconds due to the relatively low current levels identified with this type of fault. A stable arc could be as low as a few hundred amps. In this case, the main breakers may not open if an arc fault occurs within the bus in some switchboards. With the AFD System the arc event can be detected and isolated in mil-seconds. This system greatly reduces, if not eliminates, the damage to the switchboards or load centers. 1

Thermal Imaging is a very useful tool for assessing the condition of electrical equipment and is being used by the industry and the US Navy to identify loose or faulty electrical connections before they overheat and create a problem. Unfortunately, continuous thermal imaging of switchboards and load centers is not feasible or cost effective and will do nothing to prevent or reduce the effect of the forgotten tool or the loose hardware that can fall onto the bus bars; or dirt, moisture, or in the Navy s case, condensed salt that has been known to be a cause of arc flash explosions. Every day in the United States there are 5-10 ten arc flash incidents. These explosions cause pressure waves that can damage hearing or brain function and a flash that can damage eyesight and burn exposed and covered flesh. The injuries can range from minor burns to life threatening injuries and possibly death. In addition, the fast-moving pressure wave can turn loose material, such as pieces of equipment, metal tools, and other items, like switchboard covers, into lethal projectiles. It was found that each 1 PSI rise in pressure results in a force of 1.5 tons hitting a typical switchboard door. Arc flash explosions have occurred on US Navy Submarines. In the Navy we refer to them as arc faults. In 1975, an arc fault occurred onboard a US submarine and totally destroyed a generator switchboard. In the enclosed environment of a submarine, an arc fault is not just a personnel hazard - it can place the survival of the entire ship at risk. In the remote and hazardous environments that a submarine operates there are few options for rescue. After the submarine arc fault incident in 1975, the Navy did a study and identified that major electrical fires were occurring in the submarine fleet at a rate of three per year. This was deemed unacceptable and the Navy began to investigate ways to avoid these problems. The Navy investigation identified that arc faults on Navy ships, were found to be caused by loose or corroded connections, foreign objects falling onto the bus bars, dirt, moisture, insulation failure, and condensed salt; however, the predominant cause of arcing on Navy ships was found to be faulty connection of bus bars or cables. The Navy initially worked with the switchboard and circuit breaker manufacturers trying to find a solution to the submarine arcing problem. They soon found that the switchboard circuit breakers could not differentiate between normal inrush currents and abnormal currents caused by an arc and would not be effective in combating the arcing problem. In 1978 the Navy teamed up with Johns Hopkins University Applied Physics Laboratories (JHU/APL) to work on identifying methods to prevent arc faults. APL conducted extensive arc testing and data collection in their quest to identify the unique characteristics that make up an arc fault and characteristics which would be distinguishable from normal background signals. 2

Once the unique characteristics that make up an arc fault were identified, the next hurtle was to determine how this information could be used to prevent or reduce the effects of an arc fault. Several methods of identifying an arc fault were tried in the quest to determine the best method to reliably recognize the arc fault and yet minimize false alarms. APL determined that the light emitted from an arc fault could be used to detect copper emission lines from the arc while ignoring other strong light. APL teamed up with United Detector Technology to develop a photo sensor that could be used to detect copper emission lines from the arc. The photo sensors were tested and found to be very effective in identifying arc faults. However, the use of the photo sensors alone to identify the arc fault on submarines, raised concerns about the possibility of nuisance tripping, (false trips). To combat this concern APL determined that another characteristic of an arc fault, the pressure produced by an arc fault, could be used to detect the initiation of an arc fault. APL worked with World Magnetics Corp. and Scanivalve Corp. to develop a sensor based on a small pressure switch that activated at a pressure of 0.5 inches of water. The pressure sensor was used in conjunction with the photo sensors, and it resulted in a highly reliable system for detecting arc faults. This combination of both photo (light),and pressure sensors proved to be the most reliable system for submarine arc fault detection. Now that methods to detect the arc had been identified, the next step was to determine how they could be used to prevent or reduce the effects of an arc fault. The photo and pressure sensors were integrated into a system, now known as the Arc Fault Detection (AFD) System. The sensors provide input to the AFD Controller through Sensor Interface Modules, (SIMs). The SIM reads the signal from the photo and pressure sensors and determine if an arc fault has occurred and will send open signals to all the circuit breakers that supply power to the specific switchboard. For reliability, the system was designed with a Built-in-Test (BIT) feature that is used to perform an end-to-end test of the entire system. When installed aboard ship, the system is divided into zones of protection. When an arc fault is detected in a zone, the system will activate and send a signal to all circuit breakers in that zone to isolate power to the affected switchboard or load center. 3

The system s normal mode of operation is the Monitoring Mode. In this mode, all Sensor Interface Modules (SIMs) are continuously monitoring the system photo & pressure sensors. When input from both photo & pressure sensors, (in a zone), detects a qualified arc fault, the system will activate the trip relays within 1 millisecond and isolate the fault. The breaker response time is added to the AFD System time to arrive at a total time to cessation of all current flow. As configured for AQBs the total response time is typically 80-120 milliseconds. On ships with AFD Systems installed there has been no serious arc fault damage to any AFD protected switchboards. The system is credited with correctly quenching arc faults on 11 ships. There have been no false alarms reported in the 20 years these systems have been deployed. The latest versions of the AFD System have been upgraded to incorporate Continuous Thermal Monitoring (CTM). The CTM uses Thermal Ionization Detectors (TID) that will detect small particles released into the air from overheated cables or insulating material on the bus bar connections. The CTM sensor of the arc fault detection technology gives continuous detection of overheated connections, detecting at 160-300 C, well before the 1080 C needed to melt a connection and form an arc. When the CTM detects a problem, it provides a warning alarm to the operators. The operators can then investigate the cause of the alarm and make the necessary corrections before it becomes a problem. The CTM sensor does not isolate the fault down to the individual connection. Thermal imaging is the most effective way of locating the bad connection once the CTM sensor identifies the switchboard. The CTM feature has already been credited with identifying problems that would have resulted in a switchboard fire if the CTM system had not been installed. Conclusion The Arc Fault Detection (AFD) System used by the Navy has greatly reduced effects of an Arc Fault and increased the reliability of Shipboard Power Distribution systems. Overall, the Arc Fault Detection System has proven to be an invaluable asset for protecting and safeguarding the lives of our sailors and the Fleet that protects our Nation s shores. 4

References Arc Fault Detection on Navy Submarines and Ships, H. B. Land, III, Research & Technology Development Notes, JHU/APL publication, Winter 1998/99 Arc Fault Detection Systems, Brock Koren, Photonics Spectra, February 2002 Sensing Switchboard Arc Faults, H. B. Land, III, IEEE Power Engineering Review, Vol. 22 April 2002 Design of a Sensor to Predict Arcing Faults in Nuclear Switchgear, H. B. Land, III, IEEE Symposium on Nuclear Power Systems, November 2002 Design of a Sensor to Predict Arcing Faults In Nuclear Switchboards, IEEE Transactions on Nuclear Science, Vol. 50, No 4, Aug 2003, pp 1161-1165 The Behavior of Arcing Faults in Low Voltage Switchgear, H. B. Land, III, IEEE Transactions on Industry Applications, Vol. 44 No. 2 March/April 2008 Determination of the Cause of Arcing Faults in Low Voltage Switchboards, H. B. Land, III, IEEE Transactions on Industry Applications, Vol. 44 No. 2 March/April 2008 5