Rosemount 4500 Hygienic Pressure Transmitter

Similar documents
Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 752 Fieldbus Remote Indicator

Rosemount 2090F Hygienic Pressure Transmitter

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Sanitary Pressure Transmitter

Annubar Flowmeter Series

Rosemount 2088 Absolute and Gage Pressure Transmitter

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Absolute and Gage Pressure Transmitter

Configuration Data Sheet

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3095MFC Compact Orifice Mass Flowmeter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 2090F Hygienic Pressure Transmitter

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 3051SFC Compact Orifice Flowmeter

Rosemount 3051S MultiVariable Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 702 Wireless Discrete Transmitter

Rosemount 3490 Series

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 3051L Level Transmitter

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 3051SFP Proplate Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Rosemount 2100 Series

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Emerson Wireless SmartPower Solutions

Rosemount 248 Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 2051T In-line Pressure Transmitter

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 3144P Temperature Transmitter

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Rosemount 3144P Temperature Transmitter

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Rosemount 8800D Series Vortex Flowmeter

Rosemount 3051CFC Compact Flowmeter

Rosemount 2120 Vibrating Fork Liquid Level Switch

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount 2160 Wireless Vibrating Fork Level Switch

Rosemount 3051HT Hygienic Pressure Transmitter

Rosemount 1595 Conditioning Orifice Plate

Rosemount 3051 Pressure Transmitter

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 3051S Electronic Remote Sensors

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 2051CF DP Flowmeters

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 248 Temperature Transmitter

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3051S MultiVariable Extension Supplement

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3051S Series of Instrumentation

Rosemount 3144P Temperature Transmitter with HART Protocol

Druck DPI 705/DPI 705 IS Series

Rosemount High Density Temperature Measurement. Simplify Your Project

Rosemount 644 Temperature Transmitter

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Rosemount Integral Orifice Flowmeter Series

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount Compact Orifice Flowmeter Series

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Rosemount 3051 Pressure Transmitter

Rosemount 2120 Vibrating Fork Liquid Level Switch

Mobrey MCU900 Series Universal Control Unit

Dräger Polytron 7000 Fixed gas detector

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Rosemount 3051S Series of Instrumentation

Rosemount 3051CF DP Flowmeters

Rosemount 752 Remote Indicator

Rosemount 8800D Series Vortex Flowmeter

Condumax CLS16 and CLS16D

Electronic Pressure Digest. Pressure and Temperature Transmitters

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

SITRANS F M MAG 3100 P:

Rosemount 248 Temperature Transmitter

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Transcription:

Product Data Sheet Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400ºF (204ºC) Proven Rosemount technology improves process reliability and robustness Unparalleled stability reduces calibration frequency 4-20mA/HART output and AMS Suite: Intelligent Device Manager compatibility ensures easier configurations, calibrations, and operation R 37-01 Contents Specifications...................................................... page 3 Product Certifications................................................ page 5 Dimensional Drawings................................................ page 6 Ordering Information................................................. page 9 www.rosemount.com

Rosemount 4500 Product Data Sheet Now you can have the best, most reliable performance in a hygienic package The Rosemount 4500 Hygienic Pressure Transmitter brings best-in-class performance, application expertise, operational and maintenance cost savings to the biotechnology, pharmaceuticals, and food and beverage industries. Hygienic design conforms to 3-A and EHEDG standards The hygienic design of the Rosemount 4500 feature 15 µ-inch Ra mechanically polished and 10 µ-inch Ra electropolished wetted surfaces. The stainless steel design is free of voids and crevices to ensure easy cleaning and wipedowns. The 4500 is also 3-A authorized, EHEDG approved and designed according to strict ASME BPE guidelines. Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400ºF (204ºC) The 4500 was designed and thoroughly tested to ensure that not only does the 4500 minimize temperature induced errors from SIP/CIP processes, but that it also recovers rapidly. This can reduce your downtime between cleaning cycles, enabling faster turnarounds and increased plant availability. Unparalleled stability reduces calibration frequency Competitor devices can drift out of specification in just a few months and require re-calibration, consuming your time and money and risking regulatory non-compliance. The 4500 provides a better stability so that you can confidently extend calibration frequencies to reduce maintenance costs. 4-20mA/HART output and AMS Suite compatibility ensures easier configurations, calibrations and operation Lower maintenance costs with AMS Suite software, improve device performance and enable easier configuration and setup. Combining AMS Suite with the 4500 can also provide you with advanced functionality including predictive diagnostics and audit trail information to make FDA compliance simpler and paper free. Proven Rosemount technology improves process reliability and robustness The Rosemount 4500 uses the same proven sensor and electronics technology found in other industry leading Rosemount products ensuring that the transmitter is robust and reliable, improving your process reliability and increasing plant availability. 2

Product Data Sheet Rosemount 4500 Specifications PERFORMANCE SPECIFICATIONS For zero-based spans, reference conditions, Neobee M-20 oil fill, SST materials, 1 1 /2 in. tri-clamp process connections, digital trim values set to equal range points. Conformance to specification (±3 Sigma) Technology leadership, advanced manufacturing techniques and statistical process control ensure specification conformance to at least ±3 sigma. Reference Accuracy Includes the effects of terminal based linearity, hysteresis, and repeatability. ±0.15% of calibrated span from 1:1 to 15:1 rangedown ±0.01 ------------ URL % of calibrated span from 15:1 to 50:1 rangedown Span on Range 1 GP Long Term Stability 0.1% of Upper Range Limit (URL) for 3 years under normal operating conditions Batch to Batch Repeatability One batch is an exposure to a Clean in Place / Steam in Place (CIP/SIP) process with maximum temperature of 400 F (204 C) for 2 hours. ±0.025 psi (0.0017 bar) for 100 batches Vibration Effect Less than ±0.1% of URL when tested per the requirements of IEC 60770 control room level Electromagnetic Compatability (EMC) Meets all relevant requirements of EN 61326 Range and Sensor Limits Rosemount 4500 Sanitary Pressure Transmitter Range Limits Units Range 1 AP Range 1 GP Range 2 min. max. min. max. min. max. psi 2 30 0.6 30 10 150 kpa 13.78 206.8 4.136 206.8 68.94 1034 bar 0.138 2.068 0.041 2.068 0.689 10.34 kg/cm 2 0.141 2.109 0.042 2.109 0.703 10.54 FUNCTIONAL SPECIFICATIONS Dynamic Performance 250 milliseconds (response time + dead time) Ambient Temperature Effect per 50 F (28 C) 0.2% Calibrated Span + 0.02% URL Process Temperature Effect per 104 F (58 C) 0.3% Calibrated Span + 0.03% URL Service Liquid, gas, vapor, and steam applications 4 20 ma (output code A) Zero and Span Adjustment Zero and span values can be set anywhere within the range. Span must be greater than or equal to the minimum span. Output Digital process variable superimposed on 4 20 ma signal, available to any host that conforms to the HART protocol. Power Supply External power supply required. Standard transmitter (4 20 ma) operates on 11.25 to 42.4 V dc with no load. Load Limitations Maximum loop resistance is determined by the voltage level of the external power supply, as described by: Max. Loop Resistance = 43.5 (Power Supply Voltage 11.25) Load (Ohms) 1355 1000 500 Operating Region 0 11.25 20 30 42.4 Voltage (V dc) Communication requires a minimum loop resistance of 250 ohms. OverPressure Limits Transmitters withstand the following pressure without damage: Range 1: 150 psi (10.34 bar) Range 2: 300 psi (20.68 bar) Burst Pressure Limits Range 1: 300 psi (20.68 bar) Range 2: 450 psi (31.02 bar) 3

Rosemount 4500 Product Data Sheet Temperature Limits Ambient 32 to 140 F (0 to 60 C) Storage 22 to 185 F ( 30 to 85 C) Process Temperature Limits 32 to 400 F (0 to 204 C) Horizontal Mount For process temperatures above 293 F (145 C), derate ambient temperature by 7 F (4 C) for every 18 F (10 C) increase in process temperature. Top Mount For process temperatures above 266 F (130 C), derate ambient temperature by 9 F (5 C) for every 18 F (10 C) increase in process temperature. Turn-On Time Performance within specifications less than 2.0 seconds after power is applied to the transmitter Damping Analog output response to a step input change is user-selectable from 0 to 60 seconds for one time constant. This software damping is in addition to sensor module response time. Failure Mode Alarm HART 4-20mA (output code A) If self-diagnostics detect a gross transmitter failure, the analog signal will be driven offscale to alert the user. Rosemount standard and custom alarm levels are available. High or low alarm signal is software-selectable. PHYSICAL SPECIFICATIONS Process Connections 1 1 /2 inch Tri-Clamp Connection 2 inch Tri-Clamp Connection 1 1 /2 inch Fractional Line Connection Process-Wetted Parts Process Isolating Diaphragms 316L SST (2) Hastelloy C-276 (2) Surface Finish 15 μ-inch (0.38μ-m) Ra mechanically polished 10 μ-inch (0.25μ-m) Ra electropolished Non-Wetted Parts Electronics Housing 304 SST NEMA 4X IP 66 Surface Finish 32 μ-inch Ra mechanically polished Sensor Module Fill Fluid Neobee M-20 Shipping Weight for Rosemount 4500 3.0 lb. (1.36 kg.) Alarm Configuration Rosemount High Alarm: 21.75 ma Low Alarm: 3.75 ma Custom Level (1) High Alarm: 20.2-23.0 ma Low Alarm: 3.6-3.8 ma Humidity Limits 0-100% relative humidity (1) Low alarm must be 0.1 ma less than low saturation and high alarm must be 0.1 ma greater than high saturation. (2) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. 4

Product Data Sheet Rosemount 4500 Product Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota, USA Ordinary Locations Certifications As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). N0 Factory Mutual (FM) Ordinary Location; Canadian Ordinary Location CE Marking 3-A Symbol Authorization #876 EHEDG Type EL Certified to meet Hygienic Equipment Design Criteria of Document 8 per TNO evaluation #V6069 and certificate #C05-6288 European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Rosemount 4500 Pressure Transmitters- Sound Engineering Practice Electro Magnetic Compatibility (EMC) (89/336/EEC) All Models: EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 + A1, A2, and A3 - Industrial Hazardous Locations Certifications Canadian Standards Association (CSA) Approvals (Pending) I6 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Temperature Code T3C (T amb = 0 to 60 C); Intrinsically Safe for use in Class I, Zone 0 Ex ia IIC T4 (T amb = 0 to 60 C); When connected in accordance with Rosemount drawing 04500-5002; Enclosure Type 4X For entity parameters see control drawing 04500-5002; European Certifications I1 ATEX Intrinsic Safety Certificate No. Baseefa05ATEX0091X ATEX Marking: II 1 G EEx ia IIC T4 (T amb = 60 C) IP66 1180 Input Parameters: U i = 30V I i = 200mA P i = 1.0W C i = 0nF L i = 2.4μH Special Conditions For Safe Use (x) The plastic meter cover does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must not be rubbed or cleaned with solvents. N1 ATEX Type n (Pending) Certificate No. Baseefa05ATEX0092X ATEX Marking: II 3 G EEx na nl IIC T5 (T amb = 60 C) U i = 42.4V MAXIMUM IP66 North American Certifications Factory Mutual (FM) Approvals I5 Intrinsically Safe for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G; Temperature Code T4 (Tamb = 0 to 60 C); Intrinsically Safe for use in Class I, Zone 0 AEx ia IIC T4 (Tamb = 0 to 60 C); Non-incendive for Class I, Division 2, Groups A, B, C, and D; When connected in accordance with Rosemount drawing 04500-5001; Enclosure Type 4X For entity parameters see control drawing 04500-5001; 5

Rosemount 4500 Product Data Sheet Dimensional Drawings FIGURE 1. Dimensional Drawings for the Rosemount 4500 Hygienic Pressure Transmitter 1 1 /2 inch Tri-Clamp Module 4.03 (102.4) 5.50 (139.7) 2.09 (53.1) 2.49 (63.2) 3.00 (76.2) 1.50 (38.1) 2.00 (50.7) Note Dimensions are inches (millimeters) 6

Product Data Sheet Rosemount 4500 FIGURE 2. Dimensional Drawings for the Rosemount 4500 Hygienic Pressure Transmitter 2 inch Tri-Clamp Module 5.50 (139.7) 4.03 (102.4) 2.09 (53.1) 2.49 (63.2) 3.00 (76.2) 1.50 (38.1) 2.50 (63.4) Note Dimensions are inches (millimeters) 7

Rosemount 4500 Product Data Sheet FIGURE 3. Dimensional Drawings for the Rosemount 4500 Hygienic Pressure Transmitter Fractional Line Fitting Module 5.50 (139.7) 2.09 (53.1) 4.03 (102.4) 2.49 (63.2) 0.63 (16.1) 3.00 (76.2) 1.50 (38.1) 1.99 (50.4) Note Dimensions are inches (millimeters) 8

Product Data Sheet Rosemount 4500 Ordering Information Model Transmitter Type 4500 Hygienic Pressure Transmitter Code Measurement Type G Gauge A Absolute Code Pressure Range Gauge Absolute 1-14.7 to 30 psi (-1, 0 bar to 2, 1 bar) 0 to 30 psia (0 bar to 2, 1 bar) 2-14.7 to 150 psi (-1, 0 bar to 10, 3 bar) 0 to 150 psia (0 bar to 10, 3 bar) Code Wetted Materials 2 316L SST 3 Hastelloy C-276 Code Process Connection Style C11 1-1 /2 inch Tri-Clamp Connection C12 2 inch Tri-Clamp Connection C13 (1) 1-1 /2 inch Fractional Line Fitting Connection Code Oil Fill A Neobee M-20 Code Transmitter Output A 4-20 ma with Digital Signal Based on HART protocol Code Cable Entry 2A Cable Gland Code Options Wetted Surface Finish F1 Electro polished to 10 μ-inch (0.25μ-m) Ra Software Configuration C1 Custom Software Configuration (CDS required with order) Alarm Limits C6 Custom Alarm & Saturation Signal Levels, High Alarm C7 Custom Alarm & Saturation Signal Levels, Low Alarm Hardware Adjustments D1 Zero & Span Adjustments Digital Display M5 LCD Display Calibration Data Certificate Q4 Calibration data certificate consistent with ISO 10474 2.1 or EN 10204 2.1 QP Calibration Certificate and Tamper Evident Seal Material Traceability Certification Q8 Material traceability certification per EN 10204 3.1.B Surface Finish Certification Q16 Surface Finish Certification Product Certifications I1 CENELEC Intrinsically Safe, Non-incendive, Type n I5 FM Intrinsically Safe, Non-incendive I6 CSA Intrinsically Safe, Non-incendive Typical Model Number: 4500 G 2 2 C12 A A 2A (1) Intended for flow applications in line sizes less than 1 in. For use with Anderson Instruments CPM Flushmount Style process connection supplied by customer. 9

Rosemount 4500 Product Data Sheet Notes 10

Product Data Sheet Rosemount 4500 Notes 11

Rosemount 4500 Product Data Sheet Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners. HART is a registered trademark of the HART Communication Foundation. Hastelloy and Hastelloy C-276 are registered trademarks of Haynes International. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 www.rosemount.com 00813-0100-4027f Emerson Process Management Heath Place Bognor Regis West Sussex PO22 9SH England T 44 (0) 1243 863121 F 44 (0) 1243 867554 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com 2008 Rosemount Inc. All rights reserved.