Centrifugal and Positive Displacement Pumps for Hygienic Applications

Similar documents
Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

Pumps for Florida Irrigation and Drainage Systems 1

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional

W+ Pumps. Minimize Life Cycle Costs

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

Rotodynamic Pumps INTRODUCTION:

Sanitary Centrifugal Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

Wilo IL Vertical Split-Coupled Inline Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Flexible Impeller Pumps in the Food Industry

W+ Series SANITARY CENTRIFUGAL PUMPS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

FI / SFI Frame-Mounted End Suction Pumps

MIX Type Blenders. I Application. I Principle of operation

These pumps offer unique capabilities which are either not available or costly to acquire with other pumps.

What is a Safe NPSH Margin for a Centrifugal Pump? Can You Provide Too Much NPSH?

DUPLEX CONDENSATE TANK SYSTEM

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

1900 Series In-Line Pump

Horizontal Split Case Pumps Type U

A Global Leader in Pump & Valve Solutions. Jabsco Hygienic Wine Processing Flexible Impeller & Rotary Lobe Pumps

Jabsco Hygienic Food Processing Flexible Impeller & Rotary Lobe Pumps

EASY INSTALLATION GUIDE. The greatest amount of attention should be devoted to the suction piping

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PDHonline Course M140 (3 PDH) Pumps. Instructor: Lawrence J. Marchetti, P.E. PDH Online PDH Center

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

Food & Pharmaceutical Technology, Market and Applications. motralec. The heart of your process.

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

EcoPure TM HYGIENIC MAGDRIVE CENTRIFUGAL PUMP

Pumps SELECTION OF A PUMP

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Condenser Water Pump Calculator Guide

HVAC Pumps Characteristics and Energy Efficiency

PEMP RMD M.S. Ramaiah School of Advanced Studies

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Multifunction pump for handling gaseous liquids in process engineering

TYPE LF/LC/LCV END SUCTION PUMPS

APV PUMPS. W+ Pumps MINIMIZE LIFE CYCLE COSTS

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

ABOUT CONTACT ADVERTISE SUBSCRIBE

PENGUIN SERIES HSC PUMPS INTRODUCTION

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

Water engineers and utilities are often

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Air operated diaphragm pumps. Catalogue 2011 rev 1

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Intelligent Variable Speed Pump

Centrifugal Pump Failure Solutions (Emphasis Boiler Feed and Condensate Pumps)

MARLOW PUMPS RECIRCULATION

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Goulds LP3400 Series Low Pulse Fan Pumps

longevity, reliability and performance. Corporate Headquarters North America, South America, Asia and Australia Sales

The DAUREX Quick Clean Pumps

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Vertical In-line Self-Priming liquid ring Centripetal pump TYPE - STP

HyCare. The progressing cavity pump that protects the fruits of your labour. PCM Moineau TM QUALITY SAFETY EFFICIENCY

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Ducted Propeller. Airflow Volume

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

SECTION STEAM CONDENSATE PUMPS

P/N: AODD-0613-B. Sanitary Air Operated Diaphragm Pumps

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

ETP Series - Self Priming Pumps

Irrigation Water Pumps

Pumps CEU 259. Continuing Education from the American Society of Plumbing Engineers. May ASPE.ORG/ReadLearnEarn

VPC Vertical Turbine, Double Case Pump

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

FLANGE-MOUNT CENTRIFUGAL PUMPS

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

AC6/6H & AC8/8H Horizontal Metric Models

SERIES ES BASE MOUNTED TURBINE PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

PIPING SYSTEM EQUIPMENTS

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

Design And Analysis Of Centrifugal Pump

NEMO BY. Industrial applications in all business fields for low to high viscosity fluids, with or without solids

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES

Water Piping and Pumps

A Global Leader in Pump & Valve Solutions. Flojet Jabsco Rule Alcon Industrial Pumps and Valves

Industrial. Solutions brands you trust. Product Overview

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Tuthill Process Pumps Products Marketing Report Report # 3 (Rev. 04/09/06) MEAT PACKING MARKET. Meat Processing Applications

470 Series Stamped Stainless Steel Pumps

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

SaniForce. A Complete Sanitary Pump Line. unleash the

Reliable Long-Term Solutions For Your Toughest Pump

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

Transcription:

Centrifugal and Positive Displacement Pumps for Hygienic Applications ISPE Meeting November 18, 2008 Presented by: Allen E. LeBoeuf, Product Manager Oliver M. Dean, Inc. Worcester, MA Primary Issues: Selection of Technology. Control of Pumps. Materials of Construction / Certifications. Mechanical Seals. Suction Conditions. Efficiency / Power Consumption. Cleanability / Drainability / CIP ability.

When to Apply a Centrifugal Pump. When to Apply a Positive Displacement. (Discussion limited to rotary lobe style) Centrifugal vs. Positive Displacement

Centrifugal vs Rotary Lobe Centrifugal Pump Velocity Machine. Generates flow and head by the centrifugal action of a spinning impeller. Rotary Lobe Pump Fixed Displacement Machine. Delivers a fixed flow rate per revolution of the rotors.

Centrifugal vs Rotary Lobe Centrifugal Pump Low Viscosity Fluid. Generally up to 500 Cps. Can go to 1500 Cps in special circumstances, but with large sacrifice in efficiency. Medium to high flows. Medium to low pressures. Both direct drive (1800 and 3600 rpm) and variable speed operation are common. Impeller diameter is usually trimmed to meet desired flow and head (pressure). Rotary Lobe Pump High Viscosity Fluids. Generally 500 Cps and higher. Can use in low viscosity applications with sacrifice in efficiency. Low to medium flows. Medium to high pressures. Precise flow volume control, especially low flow rates. Generally operates at low speeds (up to 500 rpm) with a variable speed gear motor.

Centrifugal Pumps: A centrifugal pump will operate where the Pump Flow Head Curve Intersects with the System Resistance Curve. Example: DI Water 120 gpm 100 ft tdh (43 psi) 1.0 spgr System Head: 25 ft Static 100 ft @ 120 gpm

Centrifugal Pumps: Flow control throttling the discharge with a control valve & flow meter. Example: DI Water 120 gpm 100 ft tdh (43 psi) 1.0 spgr Pump: 3500 rpm 144mm impeller Throttle: 80 gpm 55 gpm Centrifugal Pumps: Flow control variable speed drive (control motor rpm). Example: DI Water 120 gpm 100 ft tdh (43 psi) 1.0 spgr Pump: 3500 rpm 144mm impeller Speed Change: 80 gpm 2550 rpm 55 gpm 2000 rpm

Rotary Lobe Pumps: Flow control variable speed drive (control motor rpm). Example: Fluid XYZ 30 gpm 100 psi 600 Cps 1.0 spgr Rotary Lobe Pump Model ABC 9.25 gal / 100 Rev. 0.0925 gal / Rev. 30 gpm = 324 rpm 25 gpm = 270 rpm 20 gpm = 216 rpm Note: an RPM adjustment would be required for low viscosity fluids due to pump slip.

Materials of Construction: Application Dependent For Example: Pump Construction & Metallurgy Wetted Parts: 316L ss. Elastomers: EPDM, FPM, FDA Compliant, USP Class VI Finish: 32Ra, 20Ra, 15Ra, 10Ra, Electropolish, Passivation, etc. Mechanical Seal: Single or Double; Balanced vs Unbalanced; Face Materials; Flush or No Flush. Exterior: Painted or No Paint. Drainability, Cleanability, CIP ability (more later). Standards: 3A, BPE, FDA, EHEDG, cgmp Certifications & Tests Certifications: Material Traceability Performance Guarantees / Factory Tests: Q, H, E, P, N, etc.

Mechanical Seals: Hydraulically Balanced Seal Design: Important for pressure spikes. Important for pressure reversals. External seal (outside of process). Pressure equalized

Suction Conditions: Huge Area for Potential Operational Problems: Rule of Thumb: Fluid need to be able to get to pump suction, under sufficient pressure (no vaporization), as fast as the pump want to take it, or the pump will cavitate. General Guidelines: Keep suction lines as short as practical. Short is good. Keep suction line at least one size larger than pump discharge. Bigger is better. Keep suction line velocity low. Especially with viscous fluids. Minimize pressure drop in suction line. Avoid air traps in suction line. Can cause loss of prime. Suction Conditions: If You are Involved in Sizing & Selecting a Pump for a New Application: Take Careful Note of the NPSH Required by the Pump: NPSH = Net Positive Suction Head. NPSHR = Suction Head (pressure) required at the pump to prevent cavitation. Do an NPSH Available calculation for your specific piping arrangement. NPSHA must be greater than NPSHR, or you will be Not Pumping So Hot! What is Cavitation: Vaporization of fluid at eye of impeller. As the fluid & bubbles travels along the vane, the pressure increases. The collapse of those gas bubbles back to fluid is a high energy impact. Enough to remove metal from impeller. Deflect shafts. Rotor strike.

Suction Conditions: Cavitation Damage Centrifugal Pump Impeller: Signs of Cavitation: Centrifugal Pump Sounds like pumping marbles, vibration, noise, damage. Rotary Lobe Pump Banging noise (rotors hitting case), vibration.

Efficiency & Power consumption: Positive Displacement Pumps Generally highly efficient. Typical 90 99%. Exception is with low viscosity fluids. Centrifugal Pumps Generally range of efficiency from < 10% (if running at very low flows) to 60 70%. Lots of room for careful review. The newer designs are generally 25% to 50% more efficient than the older pump technology. Reasons: Impeller geometry, improved manufacturing methods, tighter clearances, less slip (recirculation). Typical Centrifugal Pump: Casing clamp Backplate clamp Impeller Adapter Backplate Front plate Impeller nut O ring Shaft Seal Impeller nut

Centrifugal Pump Impeller Clearance: Impeller Front Clearance Has a Huge Impact on Efficiency Large Clearance = Recirculation (slip): The greater the clearance between the impeller vanes and the pump volute, the higher the recirculation slip as more fluid simply churns within the pump, and the lower the resulting pump efficiency.

Energy Savings: Centrifugal Pumps is it worth a look? Example: Centrifugal Pump 100 gpm @ 100 ft tdh Typical old Series High Eff. Pump 55% Eff 5.18 hp 67% Eff 3.73 hp 28 % power reduction At $0.10/Kwh and 24/7 operation. Power cost is $4380/yr (High Eff) Power cost is $6084/yr (Old Series) Savings = $1704/yr. Consider upgrading existing pumps too? Rule of thumb: 1 HP power reduction @ $0.10/Kwh = $1100/Yr. (cont. op).

Centrifugal Pumps Rotary Lobe Pumps Drainability & Cleanability Smooth, Flat, Flush front and back surfaces. Cusps set back 3 o Deg fall to outlet Vertical Porting

Rotary Lobe Pumps Drainability & Cleanability Zero Crevice design Front Cover Gasket Cleanability, Drainability, CIP ability: Centrifugal Pumps 3A, FDA, EHEDG certifications. Internal finish. Low point drains. Design & position of o rings & gaskets. Positive Displacement Pumps Look beyond the 3A certification. Vertical porting. Drainable cusps. Smooth, flat, flush rotor case back & front. Mechanical seal position for cleanability.

Thanks for your attention. Questions. Presented by: Allen E. LeBoeuf, Product Manager Oliver M. Dean, Inc. Worcester, MA