Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

Similar documents
Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

DRY PACK INFORMATION TROCKENVERPACKUNG

Manufacturing Notes for RFPA2189

RFFM6403. Manufacturing Notes. Table of Contents

Manufacturing Notes for RFDA0025

Manufacturing Notes for RFPA2016

RFSW6132. Manufacturing Notes. Table of Contents. 1 Introduction... 2

Manufacturing Notes for RFMD2081

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

IAQ_100 C Package

3SP_H2S_50 Package

3 3SP_O3_5 C Package

SMD 2121 Black Frame MC-S2121BHA

Preliminary specification

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

SMT450. High Performance TOP LED

45 Wide Format Hot and Cold Laminator

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Reflow Soldering Guidelines

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

PRODUCT SPECIFICATION

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

When Precision is not good enough

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

UM Store and transport requirements. Document information

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

PRODUCT SPECIFICATION

Electrical Configuration: Two single sensing elements and two compensating elements are connected to built-in FET in source follower circuit,

UNSIGNED HARDCOPY NOT CONTROLLED

Inverted Through Board Surface

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

Understanding Etched Foil Flexible Heaters

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

SonoSelect and SonoSafe energy meters

High Power COB LED. Features. Applications. ① Product line code: COB10W-C & COB10W-W. ② Product code base plate. ③ Chip code. ④ Emitting light colours

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

NOT EVERYTHING IN LIFE IS COMPLICATED.

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Metal, ceramic, plastic package products

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

STORAGE & LAMINATION INSTRUCTIONS

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Copyright 2010 Plastipak Packaging, Inc. All rights reserved.

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Air-Water heat pump Small GT

One-Side Clear Active Barrier Packaging for Moisture Sensitive Medical Devices:

PRODUCT SPECIFICATION

Teknomar Brand Industrial Type ETO Sterilizer ETO C 1445 Data Sheet

Pressure Measurement Solutions HVAC AND REFRIGERATION SYSTEMS.

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

EVERLIGHT ELECTRONICS CO.,LTD.

Moisture in Sea Containers What causes the problems and how to solve them? By: Bailey Barber

INSTRUCTION MANUAL FOR

INVITATION FOR QUOTATION. TEQIP-II/2014/CG1G02/Shopping/50

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Application Notes For LED Displays

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Operator s Manual. IP-100 Immersion Probe Cooler

PRODUCT SPECIFICATION

SMARTREPEL HYDRO AM. Fluorine-free repellents. Public, Smartrepel Hydro Georg Lang, Textile Specialties Business, /

Cleanliness of Electronic PCB Assemblies Leads to Medical Device Reliability

Product End-of-Life Disassembly Instructions

NIDS Dust sensor ED-N-DS-1408

REFRIGERANT PIPING SYSTEM

Brazed heat exchangers

OPERATION MANUAL Model 800 Nanoimprint Controller

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

AIR CONDITIONING COMPRESSOR OIL

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Aesculap Implant Systems

SonoSelect and SonoSafe energy meters

10.A4 Modified atmosphere packaging machines

APPLICATION NOTES for LED DISPLAYs

Filter Driers with Replaceable Core

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

HULME MARTIN HEAT SEALERS

Bench-Top Vacuum Oven with 28 segments programmable controller

SK68XX SIDE SPECIFICATION INTEGRATED LIGHT SOURCE INTELLIGENT CONTROL OF CHIP-ON-TOP SMD TYPE LED

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

Full System Moisture Management for Drug Preservation

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.

Pressure Transducers Ultrahigh-Purity

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Specification MBT801-S

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

PRODUCT OVERVIEW. Packaging machines for the textile industry, dry cleaners and laundries.

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Transcription:

3.1.1 a. Store materials in moisture-proof packaging in a controlled environment (humidity- and temperaturecontrolled). b. Handle PP + resin-coated films with gloves only at the edges. c. Reseal opened PP bags/as shown in Figures 3-1. d. Store PP + and resin-coated films at < 23 0 C and < 50% of humidity. e. Acclimate PP + resin-coated films if storage temp. is less than room temperature. f. Process control (storage, place of use, transport route) via temperature and moisture indicators. a. Make sure that the storage conditions do not adversely affect the functionality of the finished products. b. Handle such that adverse effects on product quality and functionality are prevented. c. Only if climate of storage room is not controlled. The resealing mechanism may vary. d. Storage conditions must be agreed or qualified with the manufacturer of the material. e. Any existing temperature differences should taken into account in qualification. f. Monitor room climate via temperature and moisture indicators. 3.1.2 Do not mix different resin types Material storage should be organized accordingly. 3.2.3 Brief period between drying and pressing (moisture absorption). Before packaging/equipping, remove moisture. Any residual moisture that may be present should be evaluated during qualification. 3.2.3.2 Determine the degree of moisture of the etched cores according to TM 650, Method 2.6.28. Insert cores separately, dry at 105 0 C for 30 min. Drying of stacked cores: Max. height: 25.4 mm Temp. stack center: 105 0-120 0 C, Time: 2 hours. In interim storage, ensure low absorption of moisture. Page 1/5

3.2.3.3 Item 3.2.3.2 also valid for multiply pressed PCBs. Drying: 180 0 C - 2 hours or 150 0 C - 8 hours or 120 0 C - 24 hours In interim storage, low absorption of moisture should be ensured. 3.3.2 Handle pressed panels/pcbs with gloves. Avoid fingerprints by using suitable methods. 3.3.3 Monitoring of temperature and moisture during the processes. Drying prior to plating and LSL. The process parameters should be defined such that adverse effects are prevented. 3.3.6 Moisture 0.1 to 0.5 %, based on the resin weight. Drying of the PCBs by the manufacturer: -> Artificial aging of the soldering surface -> Impairment of solderability/storage time. It is recommended to carry out the drying process immediately prior to the soldering process. 3.4.1 Finished PCBs should be packed in Dry Packs if they are to be temporarily stored before shipping. If necessary, the manufacturer should consult the customer with regard to the type of packaging required for interim storage 3.4.4 Drying temperatures according to Table 3-1 Note: Drying chemical tin sufaces has an adverse effect on the coating thickness of the residual pure tin. See the drying recommendations issued by the Working Group Quality Management at http://www.zvei.org/verband/fachverbaende/pcbandelectronicsystems/seiten/schlauentwickelt-clever-produziert-leiterplatten-aus-europa.aspx Page 2/5

4.1.1. Dry polyamide material prior to packaging. For packaging, use: - Vacuum-sealed moisture barrier bags - Moisture indicators - Desiccants. Drying of the PCBs by the manufacturer results in: -> Artificial aging of the soldering surface -> Impairment of solderability/storage time. It is recommended drying them immediately prior to equipping. 4.1.2 Include rigid reinforcement sheet when packaging: - Thin PCBs (< 1.40 mm) - Flexible PCBs - PCBs with complex milling pattern. To avoid mechanical impact, a suitable packaging should be selected. 4.1.5 Packing material ESD-compliant. Which packaging material is used, should be agreed between user and supplier. ESD-compliant packaging for bare PCBs is price-relevant. 4.2.1 Water vapor penetration rate of the packaging: 0.002 mg / 100 inches 2 / 24 hours Which packaging material is used, must be agreed between customer and PCB manufacturer. 4.2.2 Use a packaging material with metallic interlayer, in particular for lead-free PCBs (moisture). Which packaging material is used, must be agreed between customer and PCB manufacturer. 4.2.3 and 4.2.4 Desiccant and moisture indicators according to -J-STD-033. Qualification must be agreed between customer and supplier. Page 3/5

4.2.5 Determination of moisture by "laminate test coupons". 4.3.1.2 Use sulfur-free and ph-neutral packaging material for chem. Ag. 4.3.1.3 When vacuum sealing, do not remove air completely. The function of the desiccant will be impaired. 4.3.1.4 Include a desiccant in the moisture barrier bag next to the PCBs. 4.3.1.5 For PCBs 144 inches 2 (0,09 m²) = 25 PCBs / delivery unit per package. For PCBs > 144 inches 2 (0.09 mm²) = 10 PCBs / delivery unit per package. Use sulphur and chloride-free release paper Who provides the coupons must be agreed between supplier and customer. Use a packaging material that does not have any adverse effects on solderability / storage time. The degree of vacuum must have been optimized by the PCB manufacturer: - To achieve mechanical stability of the packaging - To achieve good functionality of the desiccant. No adverse effects caused by the positioning of the desiccant on: - Solderability - Effectiveness of the desiccant - Mechanical impact on the PCBs. The addition of desiccant should be agreed between supplier and customer. The number of PCBs in a packaging unit depends on the PCB size, PCB thickness and the structure of the circuit. The supplier should establish a suitable package size. If necessary, the manufacturer should consult the customer with regard to the use of release paper. Page 4/5

4.4.2 The package of ESD-sensitive printed circuit boards should be labeled according to ANSI, including ESD protection symbol. Which packaging label is used, must be agreed between customer and PCB manufacturer. 4.4.3 PCBs contained in dry packaging should bear a label referring to moisture or the symbol shown below. Which packaging label is used, must be agreed between customer and PCB manufacturer. 5. Goods receipt, storage and equipping of printed circuit boards Does not affect manufacturers of bare printed circuit boards Page 5/5