BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Similar documents
DGC-500 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER

Table of Contents. Protective Relays

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

SECTION AUTOMATIC TRANSFER SWITCHES

I/O ZONE 560/583 AND OPERATION MANUAL

VAMP 120 & 121. Arc flash detection units. Product picture

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

TEMPERATURE CONTROLLER

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

RTD TEMPERATURE SENSING SYSTEM

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

SECTION AUTOMATIC TRANSFER SWITCHES

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Carbon Monoxide Transmitter

DE20 INSTRUCTION MANUAL

UDC100 Universal Digital Controller Specifications

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Guide Specification Model CTG Automatic Transfer Switch

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Temperature Controllers

PANELBOARDS & BUILDING DISTRIBUTION

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Construction Electrical

Pump-Down Controller MODEL 4052

TECHNICAL DATA OBSOLETE

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

RE-PR3-E-27 3-Phase Panel Mount 27kW

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Pump-Up Controller MODEL 4062

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ESSEX ENGINEERING CORPORATION

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

SENTINEL D - Fault Passage Monitoring

SAFETY INFORMATION AND WARNINGS

EXTINGUISHING AGENT RELEASE MODULE

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

REA 105 Arc Protection Module. Operator s Manual

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

FUNCTIONAL SAFETY MANUAL

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Model 17A00 Expansion Enclosure

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

The next generation thermometer from the global leader

Ordering Key. Dielectric strength

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

the next generation thermometer from the global leader

M2500 Engine Controller Installation Manual

SEL Arc-Flash Solutions

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Installation, Operating and Maintenance Manual

ANEMOMETER 4403-RF-BAT

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Moulded case circuit brakers

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Numerical Relay MELPRO TM -S Series

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

SEL Arc-Flash Solutions

ACCURATE ELECTRONICS INC

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

03.03.mmm REV.2 09/01

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Intelligent metering and control devices. Typical applications. Features. Measure and control energy costs. Improve power quality and reliability

Installation Instructions

Analog Input Module IC670ALG630

SENTINEL A - Fault Passage Indicator

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Process & TeMPerATUre UniversAl input DigiTAl MeTers

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Electric Coils. Blower Coils. Product Information

DS7400Xi Addressable Control/ Communicator

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

STANDARD FEATURES SPECIFICATIONS

345 Transformer Protection System

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Operation and use. Functions and characteristics

MODEL 5100 VOTING LOGIC MODULE

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Transcription:

BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY RETROFIT KITS BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD. BE1-50/51B, CO Retrofits BE1-50/51B, IAC and SFC Retrofits The BE1-50/51B Time Overcurrent Relay Retrofit kits provide economical, modern replacements for electromechanical overcurrent relays in a variety of applications. ADVANTAGES Self powered from 50/60Hz systems, available for 5 or 1 amp CT secondaries. Field selectable curves match original manufacturers' shapes. Independent instantaneous overcurrent function. Second independent instantaneous available on some models can be applied to reduce arc flash hazard. Wired specifically to replace existing electromechanicals. Drawout construction, testable in the case. Qualified to the requirements of: - IEEE C37.90, C37.90.1, C37.90.2, UL508 Patented integrating reset characteristic, even when current goes to zero. Replicates electromechanical reset for all applications. Five year warranty. ADDITIONAL INFORMATION INSTRUCTION MANUALS Request Publication 9252000793 (244 CO arc flash replacement) Request Publication 9252000895 (231 IAC replacement) Request Publication 9252000994 (214, 215, 225 IAC replacement) Request Publication 9252000995 (218, 228 IAC replacement with case) Request Publication 9252000981 (219, 226 CO replacement) Request Publication 9252000790 (240 CO replacement in FT-21 cradle) Request Publication 9252000792 (241 CO replacement in FT-21 cradle with Arc Flash upgrade) Request Publication 9252000892 (229 SFC replacement) Request Publication 9252000894 (230, 234, 239 IAC66K replacement) Request Publication 9252000898 (235, 236 CO arc flash upgrade replacement) Request Publication 9252000899 (237, 238 IAC arc flash upgrade replacement) TIMING CURVES Request Publication 9252000998 or 9252000894 for Basler-equivalent IAC curves Request Publication 9252000999 for Basler-equivalent CO and BS142 curves STANDARDS, DIMENSIONS and ACCESSORIES Request Publication SDA 12570 STATE ROUTE 143, HIGHLAND IL 62249-1074 USA PHONE 618-654-2341 FAX 618-654-2351 FEATURES and APPLICATION Page 2 FUNCTIONAL DESCRIPTION Pages 3 and 4 SPECIFICATIONS Pages 5 and 6 RETROFIT INFORMATION Pages 6 and 7 ORDERING INFORMATION Page 8 UHK-8 9-11

FEATURES 15 field selectable, inverse, fixed time and British Standard (BS142) time overcurrent curves on 200 series relays (10 on 100 series). Time characteristics extend to 40 X Pickup. Instantaneous overcurrent function. Wide setting ranges: Time Overcurrent: 0.5 to 15.9 (5 Amp Unit) Inst. Overcurrent: 0.1 to 3.18 (1 Amp Unit) 2.0 to 99 (5 Amp Unit) 0.2 to 19.8 (1 Amp Unit) Inst. Overcurrent B: (on equipped models) 1.0 to 15.9 (5 Amp unit) 0.2 to 3.18 (1 Amp unit) Current pickup accuracy ± 2%. Timing accuracy ± 2%. Continuous automatic calibration. Less than 10% transient overreach. Zero Pickup setting for safety during installation. Timed Overcurrent Reset - Selectable Instantaneous or Decay Characteristic (200 series relays only). 5VA burden (at nominal) self powered from 50/60 Hz systems, utilizes standard 5 or 1 Amp CT secondaries. Drawout construction. Manual method for trip circuit testing. Standard magnetically latched targets for TOC and IOC. Direct reading front panel controls. Positive visual indication that microprocessor is executing code. UL recognized under standard 508. Qualified to the requirements of: -IEEE C37.90.1 for SWC. -IEEE C37.90.2 for RFI. -IEC 255-5 for impulse. APPLICATION The BE1-50/51B is a single phase self powered, microprocessor based time overcurrent relay. The relay is designed for use in applications requiring time delayed coordination for phase or ground overcurrent conditions. The relay can be used to provide coordinated protection for overhead and underground distribution circuits. Other applications include overcurrent back-up protection for transformers and generators, the protection of neutral grounding resistors and reactors, and motors. Since all of the time-current characteristics are included within the relay, a standard relay may be ordered before the coordination study is completed, thereby allowing the physical construction to proceed. See Table 1 for available curve types. This is also an advantage as changes in the system configuration or coordination may be accomplished without a hardware change. All models include memory to replicate the decaying reset of electromechanical relays even when power to the relay is lost. Use this function for applications that require coordination with the resetting of nearby electromechanical relays. An instantaneous overcurrent element is standard in the relay. This element is designed to minimize transient overreach. The "A" instantaneous element includes selectable delay characteristics for improved coordination with downstream devices and customer requirements. Three instantaneous units are standard with the BE1-50/51B-230, -234, and -239, replacements for the IAC66K motor protection relay. BE1-50/51B models -235 through -238 and -241 include a second sensitive instantaneous element for arc flash mitigation applications. 2 Figure 1 - Functional Block Diagram - Models with 2 Instantaneous

CURRENT INPUT A single phase of ac current from a 5 Amp, or 1 Amp, 50/60 Hz, system current transformer (CT) is applied to the BE1-50/51B. This input current provides both the power and sensing quantity for the relay. The current applied to the relay provides the energy for the internal power supply. When sufficient current is available, the Active/Pickup LED will turn green. In applications where circuit loading conditions are less than that required to illuminate the LED, the relay remains operable and will provide overcurrent protection. FUNCTIONAL DESCRIPTION TIME ELEMENT CHARACTERISTIC SHAPES FOR CO and BS142 CURVES All time characteristic curves follow the relation: T T = AD + BD + K = Time to trip M N -C T R = RD = Time for decaying reset M 2-1 Actual curve constants are available in the Instruction Manual. See page 1 of this bulletin for applicable publication number. MICROPROCESSOR The setting of the TIME DIAL, TIME CURVE selector switch, and circuit board jumpers provide the micro-processor with ten operating parameters for the desired response by the relay. The microprocessor performs the program operations based on the input current level and internal software program. When the Active/Pickup LED is green, the microprocessor is active and executing code. The watchdog timer monitors the microprocessor for specific pulses indicating proper program operation. If something occurs to disrupt the microprocessor, these pulses stop, the watchdog timer times out and sends a reset pulse to the microprocessor. The microprocessor resets and resumes normal operation. RESET Reset occurs when the current level is less than pickup. Internal switch provides selection of either an Instantaneous or a decaying reset characteristic. The instantaneous reset characteristic forces the timer to zero when the input current falls below 95% of setting. This fast reset characteristic prevents the ratcheting effect on electromechanical relay disks that occurs for repeated faults. The decaying reset characteristic replicates the decaying reset of electromechanical relay disks. When enabled, the relay will continue the decaying process even when the input current goes to zero. The Active/Pickup LED on the front panel will turn red when the applied current just exceeds the PICKUP setting. Table 1. Curve Type Basler Type Similar To S1 Short Inverse ABB CO-2 S2 Short Inverse GE-IAC-55 L1 Long Inverse ABB CO-5 L2 Long Inverse GE IAC-66 D1, D2 Definite Inverse ABB CO-6 M1, M2 Definite Inverse ABB CO-7 I1 Inverse ABB CO-8 I2 Inverse GE IAC-51 V1 Very Inverse ABB CO-9 V2 Very Inverse GE IAC53 E1 Extremely Inverse ABB CO-11 E2 Extremely Inverse GE IAC 77 B British Standard BS 142-B Very Inverse C British Standard BS 142-C Extremely Inverse F Fixed Time none INSTANTANEOUS ELEMENT CHARACTERISTICS The characteristic for phase faults is faster because the relay will be powered-up. However, the tripping characteristic for ground applications is slightly longer to allow time to power-up the relay. This longer trip time for ground applications is beneficial because it helps avoid nuisance trips. These timing characteristics are shown in Figure 2. Table 2. Current Sensing Capabilities Time Element Time Element 50/60 Hz System Time Element Max. Continuous Max. Current Instantaneous Time Element Instantaneous CT Secondary Pickup Range Current For 1 Second Pickup Range Pickup Accuracy Pickup Accuracy 5 Amp models 0.5 to 15.9 Amps 14 Amps 400 Amps A: 2 to 99 Amps 2% from 0.5 to 2% from 1 to 99 Amps in 0.1 Amp steps in 1 Amp Steps 15.9 Amps B: 1 to 15.9 Amps in 0.1 Amp Steps 1 Amp models 0.1 to 3.18 Amps 2.8 Amps 80 Amps A: 0.4 to 19.8 Amps 2% from 0.1 to 2% from 0.2 to 19.8 Amps in.02 Amp steps in 0.2 Amp Steps 3.18 Amps B: 0.2 to 3.18 Amps in 0.02 Amp Steps 3

FUNCTIONAL DESCRIPTION, continued Additional definite time delay of 0.1 seconds may be added to the first instantaneous element. The definite delay is determined by SW3-2 on the circuit card. Figure 2 - Instantaneous Characteristics OUTPUTS Separate output contacts are provided for the TIME (51), INST A, and INST B. All output contacts are configured normally open (NO). MANUAL TRIP TESTING The relay is provided with front panel test points to allow shorting the output terminals to verify external control circuit wiring. 230, 237, 239 234, 238 A: Units A. Amps x 0.2 B: Tenths B. Amps x 0.02 Figure 4 - Side View, 50-B Adjustments, BE1-50/51B-230, -234, -237, -238, -239 and -244 TARGETS Two target indicators are provided as a standard feature of the BE1-50/51B. These magnetically latched, current operated targets provide visual indication of trip by the TIME or INST output contact. These targets must be manually reset after the abnormal condition has been removed or corrected. 4 235 236 A: Units A. Amps x 0.2 B: Tenths B. Amps x 0.02 Figure 3 - Side View, 50-B adjustments, BE1-50/51B-235 and -236 Figure 5 - Side View, 50-B Adjustments, BE1-50/51B-241

SPECIFICATIONS Continuous One Second CURRENT SENSING INPUT: Current Current 5 Amp Unit 14.0 Amps 400 Amps 1 Amp Unit 2.8 Amps 80 Amps TIME PICKUP RANGE: 5 Amp Unit: 0.5 to 15.9 Amps in 0.1 Amp steps 1 Amp Unit: 0.1 to 3.18 Amps in 0.02 Amp steps TIME DROPOUT: Not less than 95% of pickup value. TIME PICKUP ACCURACY: ± 2% of setting TIME DIAL RANGE: 0.0 to 9.9 in 0.1 steps TIME CHARACTERISTICS: Nine inverse time and 1 fixed time function can be selected by a front panel switch. Characteristic curves are defined by the time characteristic equation. The fixed time characteristic provides delays of 0.0 to 9.9 seconds corresponding to the dial setting. INVERSE TIMING ACCURACY: ± 2%, ±1 cycle for multiples of pickup from 2 to 40. Below multiples of 2, errors may increase directly proportional to the value of. 1 (M N -1) FIXED TIME ACCURACY: ±2% or 30 milliseconds, whichever is greater. TIME RESET: Instantaneous or decay, internally selectable. INST PICKUP RANGE: 5 Amp Unit: 2.0 to 99 Amps in 1 Amp steps 1 Amp Unit: 0.2 to 19.8 Amps in 0.2 Amp steps INST B PICKUP RANGE BE1-50/51B-230, -235, -237, -239 (5 Amp Unit): 1.0 to 15.9 Amps in 0.1 Amp steps BE1-50/51B-234, -236, -238 (1 Amp Unit): 1 Amp Unit: 0.2 to 3.18 Amps in 0.02 Amp steps INST DROPOUT: 95% of pickup INST PICKUP ACCURACY: ± 2% of setting INST CHARACTERISTIC: See Figure 2. Additional user selectable (by DIP switches) definite delay of 0.1 seconds. INST TRANSIENT RESPONSE: Less than 10% overreach with system time constants up to 40 milliseconds. BURDEN: Burden is non-linear and resistive. 5 Amp Unit: 4.8 Ohms @ 0.5A & 0.2 Ohms @ 5A 1 Amp Unit: 120 Ohms @ 0.1A & 5 Ohms @ 1A TARGETS: Magnetically latched, manually reset for TIME and INST output functions. Operate Current: 0.2 Amp minimum Coil Resistance: 0.1 Ohm Operate Time: < 1 millisecond TARGET OPERATE CURRENT: Units with second instantaneous include jumper-selectable target operate currents. Units without jumpers: 80-200 ma Units with Jumper 1-2: 0.9-2.25 A Units with Jumper 2-3: 80-200 ma OUTPUTS: (50/51) Resistive: 120/240 Vac: Make and carry 30 Amp for 0.2 sec., carry 7 Amp for 2 min., 3 Amp continuously, and break 5 Amp. 125/250 Vdc: Make and carry 30 Amp for 0.2 sec., carry 7 Amp for 2 min., 3 Amp continuously, and break 0.3 Amp. Inductive: 120/240Vac, 125/250Vdc: Make and carry 30 Amp for 0.2 sec., carry 7 Amp for 2 min., 3 Amp continuously, and break 0.3 Amp. (L/R=0.04). ISOLATION: 2000 Vac at 50/60 Hz for one minute (1500 Vac for one minute across open contacts) in accordance with IEC 255-5 and IEEE C37.90.1 (Dielectric Test). SURGE WITHSTAND CAPABILITY: Qualified to IEEE C37.90.1 FAST TRANSIENT: Qualified to IEEE C37.90.1 IMPULSE TEST: Qualified to IEC 255-5 RADIO FREQUENCY INTERFERENCE (RFI): Qualified to IEEE C37.90.2. Field tested using five watt transceiver operating at random frquencies centered around 144 MHZ and 440 MHZ. TEMPERATURE: Operating Range -40 C (-40 F) to 70 C (158 F). Recommended Storage Range -50 C (-58 F) to 70 C (158 F). SHOCK: 15g in each of three mutually perpendicular planes. 5

SPECIFICATIONS, continued VIBRATION: 2g in each of three mutually perpendicular planes swept over the range of 10 to 500 Hz for a total of 6 sweeps, 15 minutes per sweep. AGENCY: curus recognition per UL Standard 508, File E97035 and CSA Standard C22.2 No. 14 CASE SIZE: S1 (-218 and -228 only) NET WEIGHT: 6.1 pounds 8.6 pounds (-218 and -228 only) 4.3 pounds (-240 and -241 only) RETROFIT FEATURES BE1-50/51B CO Retrofit Cradle and cover The BE1-50/51B-219, -226, -235, and -236 retrofit kits consist of a cradle and a cover and provides for installing a Basler BE1-50/51B single-phase time overcurrent relay in an existing CO case without making any wiring changes. The BE1-50/51B-244 (not shown) is a complete CO replacement relay and includes a case. BE1-50/51B IAC Retrofit Cradle, adapter plate and cover The BE1-50/51B-214, -215, -225, -230, -231, -234, -237, and -238 retrofit kits consist of a cradle, an adapter plate, and a cover and provides for installing a Basler BE1-50/51B single-phase time overcurrent relay in an existing IAC case without making any wiring changes. The BE1-50/51B-229 retrofit kit (not shown) provides for installation of a Basler BE1-50/51B single-phase time overcurrent relay in an existing SFC case without wiring changes. The BE1-50/51B-229 offers the same functionality, outputs, and curves as the 50/51B-214 but is designed to be an exact replacement for the SFC. The BE1-50/51B-218 and -228 (not shown) are complete IAC replacement relays, including case. BE1-50/51B CO FT-21 Retrofit Cradle and replacement glass The BE1-50/51B-240 and -241 retrofit kits consist of a cradle and a piece of replacement Plexiglass and provides for installing a Basler BE1-50/51B-240 or -241 relay in an existing CO FT-21 case. 6

ELECTROMECHANICAL REPLACEABLE MODELS The 244 is a direct replacement for a CO relay in a case that fits an FT-11 size cutout. It has an additional low-set instantaneous to help reduce arc flash hazard. The 240 and 241 are direct replacements for a CO relay in an FT-21 case. The 241 has an additional lowset instantaneous to help reduce arc flash hazard. The 219 or 226 kit is a direct replacement for a CO drawout relay in an FT-11 case. The 214, 225, or 231 kit is a direct replacement for an IAC drawout relay. The 231 kit or 232 direct replacement relay replaces a single element IAC relay with a dual element relay. The 229 is a direct replacement for selected SFC drawout relays. The 230, 234, and 239 are direct replacements for the IAC66K motor protection relay. The 215 is a retrofit for the IAC66C relay, except Terminals 1 and 9 are internally connected. CO models that may be retrofitted with the BE1-50/51B: The 235 or 236 kit is a direct replacement for a CO drawout relay in an FT-11 case. It has an additional low-set instantaneous to help reduce arc flash hazard. The 237 or 238 kit is a direct replacement for an IAC drawout relay with an additional low-set instantaneous to help reduce arc flash hazard. No electrical or mechanical rework is required to panels during retrofit. Competitively priced. One model replaces more than 100 IAC or 40 CO models in an FT-11 case listed on next page. Patent #5,751,532. Numerous technical advantages: - All units are equipped with an instantaneous element. - Instantaneous element can be set lower, because the relay is corrected for transient overreach. - Therefore, the range does not need to be as high as on the IAC relay. - Ten selectable curves and wide pickup ranges. - Lower burden extends linear range of CTs. - Self-calibration feature eliminates need for recalibration, thereby reducing maintenance labor. IAC models that may be retrofitted with the BE1-50/51B: Curve CO Model Numbers Short Time Long Time Definite Moderately Inverse Inverse Very Inverse Extremely Inverse CO-2*11*1N CO-5*11*1N CO-6*11*1N CO7*11*1N CO-8*11*1N CO-9*11*1N CO-11*11*1N NOTES: 1. * = any digit covering all pickup ranges, instantaneous, non-instantaneous, and 50 Hz and 60 Hz models. 2. Units with instantaneous elements are designated with a "B" for the eighth character in the model number. Curve Inverse Very Inverse Extremely Inverse Short Time Long Time IAC Model Numbers 12IAC51A***A 12IAC51B***A 12IAC53A***A 12IAC53B***A 12IAC77A***A 12IAC77B***A 12IAC55A***A 12IAC55B***A 12IAC66A**A 12IAC66B**A 12IAC66C**A SFC models that may be retrofitted with the BE1-50/51B-229: Curve Output Contact Circuits SFC Model Numbers Inverse 1 SFC151A*A Inverse 1 SFC151B*A Very Inverse 1 SFC153A*A Very Inverse 1 SFC153B*A Extremely Inverse 1 SFC177A*A Extremely Inverse 1 SFC177B*A NOTE: The -229 is based on and offers the same functionality as the -214 IAC replacement. Available curves and outputs (one 50 and one 51 contact) are identical to the BE1-50/51B-214. IAC models that may be retrofitted with the BE1-50/51B-230 and -234: Curve IAC Model Number Long Time 12IAC66K 7

ORDERING MODEL NUMBER: BE1-50/51B Time Overcurrent Relay How to order: Designate the Model Number and the three-digit number from Table 3 to define the configuration desired. NOTE: Existing case must have appropriate terminals for a multiple element relay. 5 Amp System CT Secondaries 1 Amp System CT Secondaries Table 3. RETROFIT RELAY PACKAGES Number of Instantaneous Elements MODEL NUMBER Complete CO replacement relay 2 BE1-50/51B-244 with same terminal connections as CO units. New case fits FT-11 size cutout. Retrofit kit for CO relays. 1 BE1-50/51B-219 A new cover included. Retrofit kit for CO relays (FT-21 case). 1 BE1-50/51B-240 Replacement glass for existing cover is included. Retrofit kit for CO relays (FT-21 case). 2 BE1-50/51B-241 Replacement glass for existing cover is included. Retrofit kit for CO relays 2 BE1-50/51B-235 New cover included. Complete IAC replacement relay 1 BE1-50/51B-232 with same terminal connections as IAC units. S1 style case. Complete IAC replacement relay 1 BE1-50/51B-218 with 50 and 51 on shared terminals. S1 style case. Complete IAC66K replacement relay 2 BE1-50/51B-239 with same terminal connections as IAC66K units. S1 style case with cover. Retrofit kit for IAC66K relay 2 BE1-50/51B-230 Retrofit kit for IAC relays 1 BE1-50/51B-214 BE1-50/51B-215 BE1-50/51B-231 Retrofit kit for IAC relays 2 BE1-50/51B-237 Retrofit kit for SFC relays 1 BE1-50/51B-229** Retrofit kit for CO relays 1 BE1-50/51B-226 New cover included. Retrofit kit for CO relays 2 BE1-50/51B-236 New cover included. Complete IAC replacement relay 1 BE1-50/51B-228 with same terminal connections as IAC units. S1 style case. Retrofit kit for IAC66K relay 2 BE1-50/51B-234 Retrofit kit for IAC relays 1 BE1-50/51B-225 Retrofit kit for IAC relays 2 BE1-50/51B-238 ** See notes on page 7 for SFC compatibility information. STANDARD ACCESSORY: A test plug (Basler P/N 10095) is available to allow testing of the relay without removing external wiring. 12570 State Route 143, Highland, Illinois 62249-1074 USA Tel +1 618.654.2341 Fax +1 618.654.2351 e-mail: info@basler.com www.basler.com P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE Tel +33 3.88.87.1010 Fax +33 3.88.87.0808 e-mail: franceinfo@basler.com No. 59 Heshun Road Loufeng District (N), Suzhou Industrial Park, 215122, Suzhou, P.R.China Tel +86(0)512 8227 2888 Fax +86(0)512 8227 2887 e-mail: chinainfo@basler.com 111 North Bridge Road #15-06 Peninsula Plaza Singapore 179098 Tel +65 68.44.6445 Fax +65 65.68.44.8902 e-mail: singaporeinfo@basler.com Printed in U.S.A.