High Frequency Sensor

Similar documents
Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

18W Round LED Wall/Ceiling Light with Microwave Sensor

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

360º Surface Mount Ceiling PIR Light Controller

360 Surface Mount Ceiling PIR Light Controller

60W Multi PIR Bulkhead

12W Round LED Wall/Ceiling Light with Microwave Sensor

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

5W LED Energy Saver PIR Bulkhead

Programmable Security Light Switch

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

360 Ceiling PIR Light Controller

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Emergency Assist Alarm Kit Single Zone

Digital Room Thermostat with Night Set-back

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

Cat. No TPT44. Installation & Operating Instructions

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Battery Powered Electronic Room Thermostat Cat. No. TRT033

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

Electronic Room Thermostat Cat. No. TRT030

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Electronic Frost Thermostat

Battery Powered Electronic Programmable Room Thermostat

Compact Movement Activated Sensor Installation Instructions

Installation & Operating Instructions

User Manual 120/240/300 Outdoor Motion Detector

"Options" Sensor Module

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

LED Lighting. Solutions

PMCSF6 OCCUPANCY SENSOR

SENSA MRE DDM MR

1. Basic safety information 3 2. Proper use 3

Analogue Dimming Microwave Presence/Absence Detector

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

1. Basic safety information 3 2. Proper use 3

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Security Light Transmitter

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Movement-based energy control

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

MWS3A-PRM Product Guide

Direct Dim Microwave Presence/Absence Detector

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

LED Lighting. Solutions

SWITCHLITE MRE SLDM ADJ

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

SHORT WAVE INFRARED PANEL DRYER

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Motion Sensor. Specifications

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

Devilink RS Installation Manual GB-DAS

Simple Instructions for the WisePIR

Professional, Rewireable, Linkable LED Lighting

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

LED Lighting Solutions

LIMITED LIFETIME WARRANTY

1. Basic safety information 3 2. Proper use 3

Ceiling Microwave presence/absence detector 12-24V AC/DC

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

The Power To Supply... All Your Electrical Products

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Xpelair Simply Silent DX150

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Super. Bright. Lumens! Super. Slim!

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

The Power To Supply... All Your Electrical Products

SH3020 USER INSTRUCTIONS

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Autofill counter top water boiler

Acusensor 3. Instruction Manual

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Transcription:

Model: HF1 Installation & Operating Instructions High Frequency Sensor

1. Specifications: 1. Power: AC 220 ~ 240V 50MHz. 2. Sensor Technology: 5.8GHz High Frequency. 3. Switching capacity: 1000W Incandescent or Halogen / 500VA Fluorescent or Low Energy. 4. Angle of coverage: 360 with 160 angle of aperture. 5. Lux setting: 1 ~ 2000 Lux. 6. Time setting: 3 sec to 30 min. 7. Manual override: Switchable (4 Hours). 8. Warm up: 60 sec. 9. Indoor use only. 2. Adjustments: 1 1. TIME: The detector has an adjustable TIME ON control from 3 sec. to 30 min. Move the time indicator fully anti-clockwise for the shortest time (approx 3 sec). Move the time indicator fully clockwise for the longest time (approx 30 min). The timer starts working after the last detected movement. See Fig. A. 2. RANGE: The sensor has a detection range which is adjustable from 0.5m to 6m. Move the range indicator fully anti-clockwise for the minimum setting (0.5m). Move the range indicator fully clockwise for the maximum setting (6m). See Fig. B. 3. LUX (light level): It can be set to any level between 1 2000 Lux. Move the lux indicator fully anti-clockwise for night time operation (approx 1-8 Lux). Move the lux indicator fully clockwise for daylight operation (approx 2000 Lux). See Fig. C. Fig. A Fig. B Fig. C

3. Detection Range: The integrated HF sensor emits high-frequency electromagnetic waves (5.8GHz) and receives their echo, any change in echo is perceived by the sensor and will indicate the presence of a person(s) or animal(s). A microprocessor triggers almost without any delay and will activate the connected lights or applications. Detection is able to pass through glass, doors and around partitions with 360 degree coverage. See Fig. D, E. 6m 2 Min. 6m h=2.4~3m Fig. D Fig. E Max. 3.6m Min. 6m h=2.4~3m 4. Safety Instructions: 1) Disconnect the power supply before any installation. 2) During the installation, the power cable must be voltage-free when connected. Therefore we recommend you switch off the power and check there is no voltage with a voltage tester before you start. 3) Please note that the sensor must be protected by a 5A circuit breaker. 4) The mains cable needs to be 0.5~1.5mm².

4. Ceiling Flush-Mount Installation: Warning: If you have any doubts about the installation, please ask a qualified electrician to install it and ensure that the sensor is screwed securely to the ceiling without any movement. Ø112mm Ø112mm Fig. F Fig. G 3 1. Determine the best location for the sensor. 2. Drill a hole of 112mm in diameter in the ceiling. The thickness of the ceiling must be between 5 and 25mm. See Fig. F. 3. Connecting the power supply. Please refer to the subject of Connection to the power supply in page 5 and the wiring diagram. See Fig. J. 4. Please remove the metal mounting feet from the accessory pack and clip on the HF1. Make sure the mounting feet is clipped to the correct position. See Fig. G. 5. Adjust the metal mounting feet vertically first (Fig. H) and then push the HF1 upward into the hole until the mounting feet holds the ceiling and the unit in place. See Fig. I. 6. Adjust TIME, LUX and RANGE controls. Please refer to the subject of Initial set up and operation in page 5.

Fig. H 4 Fig. I Note: 1. The ideal height for sensor is between 2.4m to 3.0m. 2. Please do not install in a location, which is subject to water spray, rain or wet conditions. 3. Please do not install in a place where the sensor s performance will be masked by metal objects in front of the sensor. It might affect the total detection distance.

5. Connection to the Power Supply: Important: 1) Note: This sensor must be installed according to local Wiring Regulations and Code of Practice. 2) Ensure the supply is disconnected at the distribution board before beginning with the electrical wiring. If in doubt, the cables must be checked with a voltage tester. 3) Study the wiring diagram below before making any electrical connections. Incorrect wiring of the unit could destroy the sensor. Connection: 1) The mains supply is connected to the AC IN terminals marked L (Live) and N (Neutral). See Fig. J. 2) The output (or Load) is connected to the LOAD terminals marked L (Switch Live) and N (Neutral). See Fig. J. 5 Load AC IN 220V ~ 240V Fig. J Initial set up and operation: After 4 Hours or switch Off 2 Sec. and ON Switch Power On Off Auto Mode Switch 2 x Off and On Permanent On

1) When powered on (after the 60 seconds warm up) the sensor goes into the auto mode. Please open the front cover and turn the TIME setting to its minimum and the LUX setting to its maximum in order to test. 2) Walk in front of detector until light comes on. This checks the operation of the detector and the field of view. 3) Turn the TIME and LUX to the desired positions. 4) To switch the light permanently ON (4 hours max), switch OFF and ON twice in rapid succession within in the range of 0.5 sec to 2 sec. This will change the HF1 from auto mode to manual override mode. 5) The sensor will automatically turn off after 4 hours or by switching power switch OFF for 2 sec and ON again. 6) The LED will flash 3 times when sensor goes into auto mode. 6 Note: If LED is still on, it means it is in override mode; make sure to switch off power for more than 2 sec. When in override mode, the LED will be on permanently. 6. Trouble Shooting: Malfunction Cause Sensor without power Fuse blown, not switched ON Short circuit Sensor does not Fuse blown switch ON Bulb blown Lux setting in night time mode during daytime operation Sensor does not Detect continued switch OFF movement Permanent light ON Sensor switch keeps Curtains, pets, etc switching ON and OFF Solution Replace fuse and switch ON mains switch. Check supply with voltage tester Check connection Replace fuse and check connection if necessary Replace bulb Readjust Lux setting Check detection area in detection range Switch off permanent light Check detection area

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Designed in the U.K. 67-058-474 Zerofour February 2012 Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com