Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Similar documents
Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger PIR 7200 Toxic Gas Detection Transmitter

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger REGARD -1 Control System

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger REGARD -1 Control System

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger REGARD -1 Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Pac 3500 Single-Gas Detection Device

Dräger REGARD 3900 Series Control System

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-am 5000 Multi-Gas Detector

Dräger X-am 2500 Multi-Gas Detector

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Flame 5000 Flame Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger PEX 3000 Flammable Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-zone 5500 Area Monitoring

Dräger QuadGard Control System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger PIR 7000 Flammable Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pac 3500 Single-Gas Detection Device

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 5000 Multi-Gas Detection

Dräger Pac 6000 Single-Gas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger X-am 2500 Multi-Gas Detection

Dräger Pac 8500 Single-Gas Detector

Dräger Pac 5500 Single-Gas Detection Device

Dräger Bump Test Station Calibration and Bump Testing

D D D Dräger Gas Detection ST Dräger: Technology for Life

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger Containerized Live Fire Training System (CLFTS)

GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 7000 Single-Gas Detection Device

Dräger Flame 2100 Flame Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger Pac 8000 Single-Gas Detection Device

Training Authorised Gas Tester Level 1. Basic Information

Dräger Configuration and Evaluation Software

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Flame 2500 (IR3) Flame Detection

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Training Gas Detection Level 3 Maintenance and Repair

On-site & Shutdown Safety Service CSE Monitoring

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Pac 6000 Single-Gas Detection Device

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Pac 8500 Single-Gas Detection Device

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Tropic 2.0 ultrasonic nebuliser

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron SE Ex Fixed Gas Detector

Dräger X-zone 5500 Area Monitoring

Dräger AFS 3000 Aircraft Fire Simulator

Oxylog VE300 Emergency & Transport Ventilation

Dräger VVP 1000 System Components

Exterior Live Fire Training System (ELFTS) the QUAD

Dräger Exterior Live Fire Training System (ELFTS-C), the CAR

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Dräger UCF 7000 Thermal Imaging Camera

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Dräger Flame 2500 Flame Detection

Models TX-KE and TX-KP Toxic Gas Transmitters

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Flame 5000 Flame Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

GAS DETECTOR ST400EC PART.NO

The SharpEye 40/40I (IR3) Flame Detection

Dräger X-zone 5500 Multi-Gas Detection Device

Products and performance

Transcription:

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors When you need to selectively measure the smallest concentrations of airborne toxic gases and oxygen under ambient conditions, Electrochemical DrägerSensors are your answer. These long-life EC sensors for Dräger transmitters offer fast response times, high accuracy, and unmatched stability.

02 Electrochemical (EC) DrägerSensors Benefits Designed for a long, reliable lifetime Dräger combines resistant plastics, such as PTFE, with the purest catalysts make a sensor that provides reliable measurement for a long period of time. A patented internal pressure compensation mechanism compensates for adverse environmental influences such as changes in humidity, temperature expansion, and weather-related variations in air pressure. A large electrolytic reservoir and large electrode areas provide sufficient reserves for a long lifetime, even in harsh industrial environments. Ready for immediate use All sensors are factory tested with target gas and calibration values are saved in the internal electronic memory. As a result, sensors in the field can be used immediately in the corresponding transmitters. High quality manufacturing guarantees long stability and low age-related drift. Designed for use in a wide range of environmental conditions All sensors have an internal temperature sensor. Between -40 F/-40 C and +149 F/+65 C, the temperature influence is compensated to zero, and the sensitivity is compensated. The internal pressure compensation allows the transmitters to be used in a wide range of environments from extreme low pressure, to atmospheric high pressure. In combination with exchangeable selective filters, it is possible to reduce the influence of disruptive cross-sensitivities. Advanced sensor technology gives you more options Select between oxygen sensors for partial pressure measurement or for volume percent measurement. The O2-LS is the only electrochemical oxygen sensor in the world that does not wear out. Due to a replaceable electrolyte, the AC acid gas sensor has an unlimited lifetime. Dräger also offers sensors with organic electrolytes for detection limits in lower ppb range. Unmatched performance Performance advantages of Dräger s electrochemical sensors include high stability, excellent measurement accuracy, fast response, low detection limits, and optimized selectivity. The sensors offer comprehensive selfdiagnosis options and have no position dependency. DrägerSensors, Polytron and REGARD are trademarks of Dräger.

Electrochemical (EC) DrägerSensors 03 System Components Dräger Polytron 3000 ST-3811-2003 Continuous safety calls for nonstop gas monitoring. The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. It is part of a new generation of gas detectors developed on a modular platform. The Polytron 3000 communicates with to the central control system via a 4 to 20 ma signal. Dräger Polytron 7000 ST-3812-2003 The Dräger Polytron 7000 gas detector can satisfy all toxic gas and oxygen measurement applications on a single platform. It meets compliance requirements, as well as the high specification requirements of customized solutions. Dräger REGARD 3900 D-27777-2009 The Dräger REGARD 3900 is a standalone control system for the detection of toxic gases, oxygen levels, and Ex hazards. The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed. Dräger REGARD -1 ST-335-2004 The Dräger REGARD -1 is a standalone single-channel control system for the detection of toxic and Ex hazards and oxygen levels. The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head.

04 Electrochemical (EC) DrägerSensors System Components Dräger REGARD 7000 D-6806-2016 When you need to monitor and analyze a number of various gases and vapors, the Dräger REGARD 7000 is a modular and highly expandable analysis tool. Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Dräger REGARD 7000 is exceptionally reliable and efficient. An additional benefit is the system's backward compatibility with the REGARD. Accessories Gassing Adapter This hard PE adapter is designed for gassing of electrochemical sensors in Dräger Transmitters during calibration, and is also suitable for continuous gassing when used with a suction unit. Part number: 68 06 978 Viton Calibration Adapter ST-5676-2006 This soft adapter is made of Viton, for gassing during zero-point testing and when calibrating electrochemical sensors in Dräger transmitters. Part number: 68 10 536

Electrochemical (EC) DrägerSensors 05 Accessories Remote Calibration Adapter ST-5653-2006 This adapter is designed for calibrations in transmitters with electrochemical sensors that are mounted in locations with poor accessibility. Part number: 68 07 955 Calibration Bottle ST-5653-2006 This 3-liter plastic container is designed for generating a defined concentration of gas using test gas ampoules, when calibrating electrochemical sensors. Part number: 68 03 407 Dust Filter ST-5718-2006 This hydrophobic dust filter is designed for electrochemical polytron sensors (also see the corresponding sensor data specification). Part number: 68 09 595 Start-Up Kit AC, AC L and HF/HCI L ST-5660-2006 For filling of sensors (Part No. 6809375, 6810595) and Dräger Polytron HF/HCl L (Part No. 6809360), the kit includes bottles with electrolyte and pipette. Part number: 68 09 381

06 Electrochemical (EC) DrägerSensors Accessories Test Gas Ampoules For use with the calibration bottle, test gas ampoules are available for the following gases/concentrations: ST-5695-2006 68 07 763 Test gas ampoule SO2 10 ppm 68 07 764 Test gas ampoule SO2 50 ppm 68 07 765 Test gas ampoule NO2 10 ppm 68 07 766 Test gas ampoule NO2 50 ppm 68 07 920 Test gas ampoule CO 100 ppm 68 07 921 Test gas ampoule CO 300 ppm 68 07 923 Test gas ampoule NH3 300 ppm 68 07 924 Test gas ampoule NH3 50 ppm 68 07 925 Test gas ampoule SO2 1 ppm 68 07 926 Test gas ampoule SO2 4 ppm 68 07 928 Test gas ampoule Cl2 8 ppm 68 07 929 Test gas ampoule HCN 10 ppm 68 08 140 Test gas ampoule H2S 10 ppm 68 08 141 Test gas ampoule H2S 20 ppm 68 08 142 Test gas ampoule H240 ppm 68 08 143 Test gas ampoule H2S 100 ppm

Electrochemical (EC) DrägerSensors 07 Accessories Selective Filters Selective filters absorb interfering gases Filters the ambient air. They are located in the sensor opening of the DrägerSensor and can easily be replaced if worn out. The following selective filters are available: Selective filters for use with DrägerSensors (also see the corresponding sensor data specification): CO (6809605) 6809684 A2F CO LS (6809620) 6809684 A2F COCI2 (6809930) 6809933 K2F H2 (6809685) 6809684 A2F HCI (6809640) 6809643 NF HCN (6809650) 6809653 BF Hydride (6809635) 6809658 CF NO2 (6809655) 6809658 CF PH3/AsH3 (6809695) 6809638 MF SO2 (6809660) 6809663 KIF Calibration/Process Adapter AC ST-5628-2006 This gassing adapter is designed for calibration of DrägerSensor AC (Part No. 6810595) and for continuous gassing when used with a suction unit. Part number: 68 09 380

08 Electrochemical (EC) DrägerSensors Sensor Test Set HF/HCI L ST-5697-2006 This test set is designed for generating an HCI test gas concentrations for functional tests on the DrägerSensor AC and Dräger Polytron L HF/ HCI. Part numbers: Bottle 68 08 085 Chemical set 68 08 084

Electrochemical (EC) DrägerSensors 09 Accessories Splash Guard ST-5686-2006 This splash guard protects DrägerSensors AC (Part No. 6810595) against dripping water. Part number: 68 09 379 Related Products DrägerSensor IR ST-8821-2005 Upgrade to infrared technology in an instant. The DrägerSensor IR can replace catalytic Ex sensors (catalytic bead sensors, pellistors) without additional installation work. Catalytic Bead DrägerSensors ST-7769-2005 Measuring combustible gases and vapors is essential for the safety of your people and your facilities. Intended for Dräger's fixed gas detectors, Catalytic Bead DrägerSensors are designed for continuous monitoring and detection of combustible gases and vapors with different versions for different applications and concentrations.

10 Electrochemical (EC) DrägerSensors Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437) Technical Service: USA +1 800-4DRAGER (+1 800-437-2437) Locate your Regional Sales Representative at: www.draeger.com/contact 91 03 419 17.04-1 HQ PP Subject to modifications 2017 Drägerwerk AG & Co. KGaA Notes