Fact File 39 Environmental Guidance

Similar documents
Environmental Guidance Foam Fire Extinguishers

Environmental Guidance Fire Fighting Powder and Powder Fire Extinguishers

Fact File 78. Portable Fire Extinguishers under the ADR. Note: This Fact File supersedes Fact File 060 which is withdrawn

Fact File 46 Guidance to recyclers on treatment of domestic ionisation chamber smoke detectors (ICSD)

Guidance Note. Visual Alarm Devices: Conflict between BS 5839 and EN 54-23

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Farms and Similar Agricultural Facilities

Fact File 15 Ionisation Chamber Smoke Detectors and The Radioactive Material (Road Transport) Regulations 2002

Guidance Note FIA Application Guidance on BS :2015

Fact File 69 Fire Detection & Alarms

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

Commercial Waste and Recycling Facilities. Site User Information

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: EQUALITY ACT 2010

Watermist Fire Protection of Plant Rooms

Guidance Note. Fire Alarm Detector Applications and Documentation of the Selection

Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

Guidance on Video Smoke Detection Technology (VSD)

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

The Route to Third Party Certification

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

BS 5839: Part THE CHANGES

5.5 CD/14 (Warning & Advice Notice)

Environmental Guidance Legislative overview

Permanent Water Saving Plan

ENGINEERING STANDARD FOR FIRE STATIONS ORIGINAL EDITION NOV. 1993

Training Courses. The most comprehensive technical fire safety training programme.

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

South Australian Regulatory Requirements

Japan's efforts on management of PFOS

Permanent Water Saving Plan

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

CD/12 Form (Landlord Oil Installation Check)

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

PENRHYN QUARRY BETHESDA GWYNEDD. Proposed Inert Recycling Facility DESIGN AND ACCESS STATEMENT

79th OREGON LEGISLATIVE ASSEMBLY Regular Session. House Bill 2386

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Part 1 Scope. Part 2 Definitions

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

CIRCUIT BREAKER FAIL PROTECTION

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

Consumer unit replacement in domestic and similar premises

EMERGENCY PHONE: or (651) (24 hours)

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Code of Practice. A guide for users of Small Wastewater Treatment Systems (Package Plants) 1 Queen Anne s Gate London SW1H 9BT.

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017

Approved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010

Plymouth University - Application for Landlord Registration

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

JAPANESE KNOTWEED GUIDANCE FOR IDENTIFICATION & CONTROL

EMERGENCY PHONE: or (651) (24 hours)

Flooding in Test Valley

Query: Do water heater installations and replacements require a plumbing license, permit, and inspection in the state of Colorado?

Barnsley Accredited Landlord Scheme Accredited Property Registration Form

EMERGENCY PHONE: or (651) (24 hours)

Fire Risk Management Policy. UK September 2017

AECOM Wolverhampton City Centre Metro Extension Environmental Impact Assessment Scoping Report 64

Electrical Safety Policy and Management System

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it.

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Table of Contents. Consolidated Version, revised and verified January 24, (Original) August 21, 2017

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Fire Safety Logbook. FOLLOW the regulations. MANAGE fire risks. RECORD relevant checks

Antilia Wading Pool Glass Countertop Installation and User Guide

The Basel Convention in Thailand

ACCESS POLICY FOR RECYCLING CENTRES

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

EMERGENCY PHONE: or (651) (24 hours)

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

CIPC Aerosol Potato Sprout Inhibitor

Millfield Schools Fire Risk Prevention Policy

Atomic Energy Licensing Board

Welborne Village Hall

BIOACTIVE COIL TREATMENT FOR TREATMENT OF AIR CONDITIONING HEAT EXCHANGE COILS

property report Josh s House Living Key: enhancing prosperity and quality of living

Event Management CHECKLIST

Iowa Electrical Examining Board Division of the State Fire Marshal s Office

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

GUIDELINES TO SHOP COMPLIANCE

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET 3M Earloop Fluid Resistant Face Mask Cat. # 1820, 1820FS 09/18/12

ORDINANCE NUMBER DRAFT. An ordinance amending Title 12 Environmental Protection of the Los Angeles County

Application for Planning Permission. Town and Country Planning Act 1990

managing asbestos in church buildings

KETTLEBURGH VILLAGE HALL HEALTH AND SAFETY POLICY

GK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

Technical reference Reference & design

PLANNING FOR THE SUPPLY OF BUILDING AND ROOFING STONE The Planning Officers Society 2008

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

EMERGENCY PHONE: or (651) (24 hours)

FPA Australia submission to the review of the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 and associated legislation.

COMPLIANCE WITH SAFETY

EMERGENCY PHONE: or (651) (24 hours)

Fire Safety. A TUC guide for trade union activists

Transcription:

Fact File 39 Environmental Guidance Foam Fire Extinguisher Disposal

Foam Fire Extinguisher Disposal INTRODUCTION... 3 ENVIRONMENTAL ISSUES... 4 FOAM EXTINGUISHERS... 5 HANDLING OF EXTINGUISHERS OFF SITE/AT SERVICE DEPOT... 6 DISPOSAL OF FOAM... 7 APPLICABLE REGULATIONS... 8 SOURCES OF FURTHER INFORMATION... 9 2 of 9

INTRODUCTION This Fact File is intended to give guidance on the environmental issues relating to foam fire extinguishers and their disposal. It covers the applicable legislation, how to handle the extinguishers at the customer s site, and looks at the available options for collection and disposal. 3 of 9

ENVIRONMENTAL ISSUES The Groundwater Regulations are designed to prevent dangerous substances from causing direct or indirect pollution to groundwater (used as a source of drinking water). Fire fighting foams cannot be discharged to groundwater and need to be disposed of safely via foul sewer to a waste water (sewage) treatment plant, or by incineration. Note: Foam extinguisher concentrates and extinguisher foam charges must NOT be discharged onto car parks, hard standings, grass, waste land, streams, rainwater/storm drains or any other outdoor site. 4 of 9

FOAM EXTINGUISHERS Annual service During the annual service, the recommendations in the FIA guide to servicing and/or the manufacturer s instructions should be followed. When the extinguisher is emptied, the foam solution contents (media) should be stored in an appropriate container before returning to the extinguisher. If the media requires replacing, the discarded media should be kept in a container until all the extinguishers have been serviced. If at the end of the service only a few extinguishers (1-5) have been emptied, then it should be possible to dispose of the collected media down the foul water sewage system where it cannot enter groundwater. Steps should be taken to minimise foaming. The media should never be discarded anywhere on-site other than the foul water system. Alternatively, if the collected media is from more than five extinguishers, it should be collected for disposal by the methods described in sections 4 & 5 below. Five year discharge testing Discharge testing is now a contentious issue; the run-off from the extinguisher cannot enter the groundwater system. Therefore the previous practice of carrying out the discharge on the customer s site in areas where it could reach the groundwater (eg car parks, grass, verges, ditches, bare soil, rainwater drains or wasteland) is not permitted and could result in legal proceedings by the Environment Agency. It should be possible to discharge small numbers of extinguishers into the foul water system as described above, under the site owner s trade effluent discharge consent. However, the practicality of discharging extinguishers down toilets needs to be considered as this may lead to health & safety issues for technicians. Discharging a foam extinguisher on the upper floors of multi-storey building should also be avoided. Note: Trade effluent is deemed to be all waste that is not domestic production, so extinguisher discharges thus fall into this category. Site owners will hold a discharge consent from their local water undertaking for declared discharges. The disposal of trade effluent into the foul sewage system on a customer s site will be covered under their permissions and consent under the Trade Effluents (Prescribed Processes and Substances) Regulations 1989 if in doubt, the site owner and the water undertaking should be consulted. 5 of 9

HANDLING OF EXTINGUISHERS OFF-SITE/AT SERVICE DEPOT Collection Note: To transport any waste you, as a company, are required to hold a waste carriers licence. An item is defined as waste the moment the owner no longer requires or has possession of the item. When transporting extinguishers from customers sites you will need to comply with the requirements of the ADR 2009 (see Fact File 23). The ADR states that UN No 1044 fire extinguishers provided with protection against inadvertent discharge and securely packaged in strong outer packaging, are exempt from the ADR requirements. This can mean that the original packages are secured in the van or a secure lockable cage. If you transport extinguishers not secured as described above, you will have to comply and this means your drivers will have to be fully trained and certificated under ADR 2009. Note: Under the Environmental Protection (Duty of Care) Regulations, duty of care note must be given to the client when you remove waste from their site. Noting the transport issue above, there are a number of options available for the collection of foam for disposal and the practicality of each should be considered before agreeing a procedure for collecting and disposing of foam. Keeping the media in the extinguisher and replacing the old extinguisher with a new extinguisher. The extinguishers are returned to the service depot for safe collection and disposal as a complete unit or the contents emptied into a secure container for storage/disposal. Keeping the media in the extinguisher and replacing the old extinguisher with a new extinguisher. The old extinguishers are then left on the customer s site for collection by licensed waste disposal company. Collecting the foam in a secure container in the technician s vehicle before transferring to a larger container at the service depot. Storage Measures should be taken to ensure that any stored media cannot leak and reach groundwater. The media should be stored in sealed containers. 6 of 9

DISPOSAL OF FOAM Foul water sewage system It is currently permitted to dispose of foams (except PFOS based) via the foul water sewage system (see 3.2 on page 3). Note: If you are collecting and disposing of the foam media from large numbers of extinguishers over 50L (per previous agreements with the water undertakings) at any one time, you will need to obtain consent to discharge from your local water undertaking. Whenever you intend to dispose of any media via the foul sewage system, this should be covered by a discharge consent from the local water undertaking for the site where the discharge is taking place. High temperature incineration PFOS foams must be disposed of via high temperature incineration. Recycling of components Fire extinguisher parts and components should be recycled through registered facilities. 7 of 9

APPLICABLE REGULATIONS Detailed information on the regulations that apply to foam fire extinguishers are given in Fact File 20, however below is a list of some of the regulations with which you will need to comply: The Groundwater Regulations 1998 Water Resources Act 1991 Water Industries Act 1991 Environmental Protection (Duty of Care) Regulations 1991 Control of pollution (Amendment) Act 1989/ Controlled waste (registration of carriers & seizure of vehicles) Regulations 1991 The Trade Effluents (Prescribed Processes and Substances) Regulations 1989 The Environmental Permitting (England and Wales) (Amendment) Regulations 2009 (SI 1799 2009) Environmental Permitting (England and Wales) Regulations 2007 (SI 358 2007) 8 of 9

SOURCES OF FURTHER INFORMATION The following websites provide more information on environmental issues and legislation: Environment Agency www.environment-agency.gov.uk/ Environment Agency NetRegs www.netregs.gov.uk/ Envirowise www.envirowise.gov.uk/ DISCLAIMER The information set out in this document is believed to be correct in the light of information currently available but it is not guaranteed and neither the Fire Industry Association nor its officers can accept any responsibility in respect of the contents or any events arising from use of the information contained within this document. Tudor House, Kingsway Business Park, Oldfield Road, Hampton, Middlesex TW12 2HD Tel: +44 (0)20 3166 5002 www.fia.uk.com 9 of 9