Calio-Therm S NC/NCV Type Series Booklet

Similar documents
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

Vertical Ring-section Pump WKTB. Type Series Booklet

Cleaning System. Amajet. Type Series Booklet

mini-compacta Type Series Booklet

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Conductivity Electrode LRG Original Installation Instructions English

KSB mechanical seals for water and waste water applications

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Level Electrode NRG NRG Original Installation Instructions English

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

Installation and instruction manual SOLAR STATION

Installation & Operating Instructions

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Building Services. KSB Building Services. A Real Welcome Home.

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Mechanical seals external, single or double, to DIN EN 12756

SL EX.4.51D

Chemical Pumps Vertical Chemical Pump Type TNP

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

UP/UPS-B/UPN Hot Water Service Circulators

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Inline-Pumps Type NCV /NCVL

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

NON-SUBMERSIBLE WATER PUMP

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

SOUTH AFRICAN NATIONAL STANDARD

TP /4-A-F-A-BQQE 400D 50HZ

LC3000 Level Controller Installation and Maintenance Instructions

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

UV Flame Supervision System

1592P01. for liquids in piping DN

GMA Panels with double busbar

INSTALLATION & OPERATION MANUAL

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

FSW300 Series Flow Switch

Astro Express 2 - Hot Water Delivery System

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Level Electrode NRG Original Installation Instructions English

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

! WARNING. Before using product, read and understand instructions.

CRU-S Series Stainless Steel Condensate Recovery Unit

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

KUBOTA Double suction volute pump

EN Instruction manual

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

LPC3BSP65 & LPC3BDP65

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

High-efficiency circulating pumps Heating Air conditioning 50 Hz

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Gas cylinder scale Model GCS-1

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

PROFIBUS-PA Display RID 261 PROFIBUS-PA

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

Temperature Sensor TRG Original Installation Instructions English

Modular standard power units. Type ABSKG. Contents. Features. RE Edition: Replaces: Tank size 20, 40 and 60 liters

SL S.S.N.51D

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

CAP SERIES SEWAGE AND WASTE WATER PUMPS

ACS-30-EU-EMDR- 10-MOD

hygienic design CLEANLINESS MADE TO MEASURE: HYGIENIC DESIGN FANS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Vacuum suction nozzle OVEM-...-1P/1N

V80-H Multistage Pump Instruction Manual

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

Sealless Immersion Pumps for Industrial Applications

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Cooling Fans ver ver.4

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

15-BER3. parts list as Excel-spreadsheet. Tsurumi Europe GmbH

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

Transcription:

High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet

Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 23/02/2017

Contents Contents Building Services: Heating... 4 Drinking Water Circulator Pumps... 4 Calio-Therm S NC... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... 4 Product benefits... 4 Certifications... 5 FluidFuture energy efficiency concept developed by KSB... 5 Selection information... 5 Overview of product features / selection tables... 5 Technical data... 6 Characteristic curves... 6 Dimensions... 7 Installation information... 7 Scope of supply... 7 Accessories... 8 3

Building Services: Heating Drinking Water Circulator Pumps Building Services: Heating Code NCV Drinking Water Circulator Pumps S Calio-Therm S NC Description NCV Fixed speed with integrated non-return valve and shut-off valve (ball valve) Connection variants S With plug-type connection K With power cable 1) Design details Maintenance-free glandless pump Screw-ended Three speed levels Operating modes Operation at fixed speed Manual functions Setting the speed level Drive Short-circuit-proof electric motor 230 V - 50/60 Hz IP42 enclosure Thermal class F Temperature class TF 60 Main applications Drinking water circulation systems Interference emission EN 55014-1:2006 + A1:2009 + A2:2011, EN 61000-3-2:2006 + A1:2009 + A2:2009, EN 61000-3-3:2008 Interference immunity EN 55014-2:1997 + A1:2001 + A2:2008 Fluids handled Drinking water and heated drinking water of up to 65 C Fluids with a maximum kinematic viscosity of 10 mm²/s Bearings Product-lubricated Operating data Materials Operating properties Characteristic Flow rate Head Fluid temperature Hardness of fluid handled Ambient temperature Operating pressure Connection Value Q [m3/h] 0,7 Q [l/s] 0,19 H [m] 1,0 T [ C] +5 to +65 [ dh] 20 T [ C] 0 to +40 p [bar] 10 Calio-Therm S NC: R 1/2 internal thread Calio-Therm S NCV: G 1 1/4 external thread Designation Example: Calio-Therm S NCV S Designation key Code Description Calio-Therm S Type series NCV Design NC Fixed speed 1) 4 Overview of available materials Component Volute casing Shaft Impeller Bearings Can Product benefits Broad product range with many connection options No tools required for connection Easy to operate; operating status displayed High-efficiency pump for maximum energy savings Three speed levels for optimum adaptation to the system Long service life associated with the "Handwerkermarke" trade seal With integrated power cable (2 m length) and shockproof plug (plug type F) Calio-Therm S NC Material Brass CW617N Stainless steel 1.4305 Technopolymer CuSn8, suitable for drinking water Stainless steel 1.4404, wetted parts polyamide PA6.6

Building Services: Heating Drinking Water Circulator Pumps Certifications FluidFuture energy efficiency concept developed by KSB Overview Label Effective in: Germany Comment All sizes www.ksb.com/fluidfuture Selection information Minimum pressure The minimum pressure pmin at the pump suction nozzle serves to avoid cavitation noises at an ambient temperature of +40 C and the indicated fluid temperature Tmax. The indicated values are applicable up to 300 m above sea level. For installation at altitudes > 300 m, an allowance of 0.01 bar / 100 m must be added. Minimum pressure pmin [bar] specified for the fluid temperature [ C] Size All Fluid temperature [ C] Up to 65 Minimum pressure [bar] 0,4 Overview of product features / selection tables Features and functions Features and functions Functions Features Non-overloading motor Functions Automatic stop when the motor is blocked Operating status indicated by LED Pump fault display (3 flashing LEDs) Calio-Therm S NC 5

Building Services: Heating Drinking Water Circulator Pumps Technical data Size Pump connection Enclosure Speed levels P 1 [W] Plug-type connection Connection cable integrated in the pump Mat. No. NC S Rp 1/2 (EN 10266) 2) IP42 3 2,5-8,0-29134811 1 NC K Rp 1/2 (EN 10266) 2) IP42 3 2,5-8,0-29134812 1 NCV S G 1 1/4 (DIN ISO 228) 3) IP42 3 2,5-8,0-29134813 1,3 NCV K G 1 1/4 (DIN ISO 228) 3) IP42 3 2,5-8,0-29134814 1,3 [kg] Characteristic curves Calio-Therm S NC 1.0 0 1 Q [US.gpm] 2 3 0 1 Q [IM.gpm] 2 1~230 VAC R 1/2 3 0.8 0.6 H [m] 0.4 2 H [ft] 1 0.2 0.0 0 0.0 0.1 0.2 Q [m³/h] 0.4 0.5 0.6 0.7 0.00 0.05 Q [l/s] 0.10 0.15 0.20 Calio-Therm S NC/0 Calio-Therm S NCV 1.0 0 1 Q [US.gpm] 2 3 0.0 0.5 1.0 Q [IM.gpm] 1.5 2.0 2.5 1~230 VAC R 1 1/4 3 0.8 0.6 2 H [m] 0.4 H [ft] 1 0.2 0.0 0 0.0 0.1 0.2 Q [m³/h] 0.3 0.4 0.5 0.6 0.7 0.00 0.05 Q [l/s] 0.10 0.15 0.20 Calio-Therm S NCV/0 2) Internal thread 3) External thread 6 Calio-Therm S NC

Building Services: Heating Drinking Water Circulator Pumps Dimensions Calio-Therm S NC/NCV Installation information Calio-Therm S NC/NCV ~117 65 Permissible installation positions Sizes Calio-Therm S NC Calio-Therm S NCV ~76 Fig. 1: Dimensions of Calio-Therm S NC S [mm] ~130 The plug-type connection / cable connection integrated in the pump can be fixed in any position (e.g. pointing downward). To this end, loosen the product-integrated union nut and move the pump head (connection housing including motor) into the required position. Then tighten the union nut again. ~135 110 ~76 ~137 Fig. 2: Dimensions of Calio-Therm S NCV S [mm] Scope of supply Depending on the model, the following items are included in the scope of supply: Pump Plug-type connection or integrated, pre-configured connection cable (depending on the size) Installation/operating manual Thermal insulation shells 2 fitted plugs preventing the ingress of foreign matter 65 ~76 ~130 Fig. 3: Dimensions of Calio-Therm S NC K [mm] 110 ~76 ~137 Fig. 4: Dimensions of Calio-Therm S NCV K [mm] Calio-Therm S NC 7

Building Services: Heating Drinking Water Circulator Pumps Accessories Electrical accessories Description Mat. No. [kg] Timer 01143799 0,2 Angular connector, black, with sealed 3-core connection cable 3 0.75 mm², length 1.5 m 18041690 0,015 8 Calio-Therm S NC

1157.55/03-EN 23/02/2017 KSB Aktiengesellschaft Johann-Klein-Straße 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 www.ksb.com