Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Similar documents
Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

Model: Ceiling Cassette V 9k-24k

Single and Multi-Zone Ductless Split Systems

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Ductless Series Variable Speed Split Systems

Presents. Variable Speed Heat Pump Ductless Split Systems

Single - Zone Systems

Specifications, Performance & Submittal

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

General Description. Operation

Specifications and Performance S2H

R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

CM R-410A High Efficiency Water Source Heat Pump

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Residential and Light Commercial Ductless Systems Catalog

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

DUCTLESS FULL LINE CATALOG

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Commercial High-Efficiency Condensing Units

Indoor Air Handlers with Compressors MVS and MVW

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

13 SEER CONDENSING UNITS

C13-Series Engineering Guide

16 SEER TWO-STAGE AIR CONDITIONERS

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Q-TEC QC-Series Chilled Water Air Conditioner

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Specifications and Performance

TECHNICAL SPECIFICATIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Specifications and Performance

Product Data INDUSTRY LEADING FEATURES / BENEFITS

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

R4H4. Product Specifications

Heating & Cooling Products

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Product Specifications. Vertical Floor Consoles By First Co.

Technical Product Guide

Samsung 360 Cassette, Single Zone, Split System

Air Conditioning & Heating. Ductless Product Catalog

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

R4H4. Product Specifications

Commercial High-Efficiency Condensing Units

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

VertiCool Aurora Engineering Guide

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Duct-Free Systems For cooling and heating solutions, the world turns to Carrier in 2005

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Q-Tec TM QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Transcription:

Presents Chilled/Hydronic Ductless Air Handlers PANTONE COOL GRAY 10 C PANTONE 3155 C

Chilled/Hydronic Ductless Air Handlers Co mfor t w h e re i t co u n t s EMI ComfortWave Ductless Series Fan Coil Air Handlers Available in a variety of capacities, features and PANTONE COOL GRAY 10 C PANTONE 3155 C Commercial Comfort Solutions No Handling of Refrigerant The ComfortWave Series use only water as the heat transfer medium; an even greener alternative to the refrigerants used in direct expansion splits systems, that still have a Global options, ComfortWave Warming Potential. Refrigerant is heavier than air, and can Air Handlers offer threaten occupants health if leaked in large volumes. application flexibility in commercial installations such as new construction, retrofitting and renovations. Minimal Building Intrusion Supply and return water pipes run within the wall, eliminating the need for inefficient ductwork or infiltrating wall openings. ComfortWave Air Handlers Long Line Length can be installed in ceilings, Insulated water lines carry conditioned supply water (Hot or Cold), suspended from ceilings or with a minimal capacity loss. This allows for much longer line on walls, delivering efficient comfort conditioning, cost- lengths to the fan coil air handler, as opposed to refrigerant split system line sets. effective operation, reliable Clean Stylish Design performance, high efficiency Our sleek low-profile selection of air handler designs allows and easy installation. freeing up more building space, to promote open designs, and blending with any decor. 2

CCP/WCP Remote Control Cassette Remote Control Architects/Engineers Function Control Convenience Equipment can be factory equipped to be controlled via a Wallmounted Thermostat, Infrared Handheld Remote Control, or Unit- HVAC/Mechanical Contractors mounted controls on High-Wall and Ceiling-Suspended models. E-Boost Electric Heat Technology (Select s) Optional, factory-installed electric heat can perfectly augment a primary heating system for emergencies/redundancy, or suffice on its own. needs of various Commercial Market segments, IT E W flexibility, to satisfy the cooling and heating CA have been designed to provide the application RI MAD EMI s ComfortWave Fan Coil Air Handlers Property Management Companies IN A ME E H P RID including both new construction and renovation projects. The features and benefits described, make these air handlers ideal for comfort control in high-rise and commercial office buildings. Bid & Spec Firms CAW CCP WCP Cassette Air Handler Ceiling-Suspended Air Handler High Wall Air Handler 3

CAW Cassette Air Handler 2-Pipe Chilled Water - Optional Electric Heat Mounts flush with ceiling, evenly distributing conditioned air. Only the facia assembly is visible. Great for conditioning rooms with drop ceilings. 8,000-36,000 Btuh Capacities 208-230V/1/60Hz Standard 115V/1/60Hz Available 220-240/1/50Hz Available No De-rate for 115V or 50Hz 6 Nominal Capacities 8,000 Btuh 20,000 Btuh 12,000 Btuh 33,000 Btuh 18,000 Btuh 36,000 Btuh 24 Vac Remote Thermostat Configuration (Thermostat Sold Separately) Infrared Handheld Remote Control Option (Remote Sold Separately) Washable Return Air Filter(s) 2-Pipe Applications Allow for Optional E-Boost Electric Heat: 1.5kW - 8,000/12,000 Btuh 3kW - 18,000/20,000 Btuh 5kW - 33,000/36,000 Btuh Supply-Discharge Air Louvers 08/12k Btuh - Manually Adjustable 18-36k Btuh - Auto Sweep or Fixed Positions Stop Factory-Installed Condensate Pump (30" Lift) Fresh Air & Branch Duct Knockouts CAW 2-Pipe Cooling Performance (High Fan) Cooling Capacity Entering / Leaving Water Temperatures (No Glycol) Entering 40/50 F 45/55 F * Dry Bulb Air Temperature Total Sensible Flow Pressure Total Sensible Flow Pressure ( F) at Capacity Capacity Rate Drop Capacity Capacity Rate Drop 50% RH Btuh Btuh GPM Ft. H 2 0 Btuh Btuh GPM Ft. H 2 0 72 7,700 7,300 1.5 3.3 5,900 5,900 1.2 2.0 CAW08 75 9,100 8,000 1.8 4.5 7,200 6,900 1.4 2.9 80 12,900 9,400 2.6 8.6 9,600 8,100 1.9 4.9 72 10,500 8,900 2.1 1.9 7,400 7,200 1.5 0.9 CAW12 75 12,700 9,900 2.5 2.9 9,300 8,400 1.9 1.5 80 17,700 11,700 3.5 5.4 13,500 10,000 2.7 3.2 72 11,800 11,800 2.3 0.6 9,000 9,000 1.8 0.4 CAW18 75 15,900 14,300 3.2 1.0 10,700 10,700 2.1 0.5 80 24,000 17,700 4.8 2.5 18,000 15,100 3.6 1.3 72 12,300 12,300 2.4 0.6 9,300 9,300 1.9 0.4 CAW20 75 17,200 15,400 3.4 1.2 11,200 11,200 2.2 0.5 80 27,200 19,400 5.4 3.2 19,400 16,300 3.9 1.6 72 26,700 22,900 5.3 2.7 19,200 18,800 3.8 1.3 CAW33 75 33,300 25,800 6.6 4.4 23,900 21,700 4.8 2.2 80 50,300 32,400 10.0 9.4 36,800 26,700 7.3 5.2 72 30,500 26,300 6.1 3.7 21,900 21,500 4.4 1.8 CAW36 75 39,700 30,400 7.9 6.1 27,300 24,900 5.5 2.9 80 58,400 37,600 11.6 12.5 43,500 31,200 8.7 7.2 *Note: Please refer to specifications for the full model number when ordering and specifying equipment. 4

CAW Cassette Air Handler CAW 2-Pipe Cassette Electrical Specifications Fan Motor Electric Heat Total Min HACR M.C.A. Volts/Phase/Hertz RLA H.P. kw AMPS AMPS Volt BRKR CAW 08/12 115/1/60 0.9 1/10 N/A 0.9 104 1.2 15 CAW 08/12 208-230/1/60 0.35 1/10 0.4 197 0.5 15 CAW 08/12 208-230/1/60 0.35 1/10 1.5 6.52 6.9 197 8.6 15 CAW 18/20 115/1/60 1.1 1/8 N/A 1.1 104 1.4 15 60 HZ CAW 18/20 208-230/1/60 0.55 1/8 0.6 197 0.7 15 CAW 18/20 208-230/1/60 0.55 1/8 3 13.04 13.6 197 17.0 20 CAW 33/36 115/1/60 1.0, 1.0 1/10, 1/10 N/A 2.0 104 2.3 15 CAW 33/36 208-230/1/60 0.5, 0.5 1/10, 1/10 1.0 197 1.2 15 CAW 33/36 208-230/1/60 0.5, 0.5 1/10, 1/10 5 21.74 22.7 197 28.3 30 CAW 08/12 220-240/1/50 0.35 1/10 0.4 198 0.4 15 CAW 08/12 220-240/1/50 0.35 1/10 1.56 6.8 7.2 198 8.9 15 50 HZ CAW 18/20 220-240/1/50 0.55 1/8 0.6 198 0.7 15 CAW 18/20 220-240/1/50 0.55 1/8 3.2 13.6 14.2 198 17.7 20 CAW 33/36 220-240/1/50 0.5, 0.5 1/10, 1/10 1.0 198 1.3 15 CAW 33/36 220-240/1/50 0.5, 0.5 1/10, 1/10 5.4 22.7 23.7 198 29.6 30 CAW Technical Data Connections CAW 08/12 CAW 18/20 CAW 33/36 Chilled Water Inlet 5/8" 7/8" 7/8" Chilled Water Outlet 5/8" 7/8" 7/8" Condensate 1/2" 1/2" 1/2" Branch Duct Diameter 5" 5" 5" Fresh Air Duct Diameter 1 1 /2" x 2 1 /2" 3" x 3" 3" x 3" Filtration CAW 08/12 CAW 18/20 CAW 33/36 Type Wire Framed Periframe Quantity 1 2 3 Arrestance 80% 80% 80% Condensate Pump CAW 08/12 CAW 18/20 CAW 33/36 Maximum Head 30" 30" 30" Nominal Flow Rate (Gpm) 0.1 0.1 0.1 Shipping Weights 208-230V & 220-240V 115V Lbs. (kg Lbs. (kg) CAW08 70 (31.8 kg) 80 (36.3 kg) CAW12 70 (31.8 kg) 80 (36.3 kg) CAW18 108 (49.1 kg) 118 (53.5 kg) CAW20 108 (49.1 kg) 118 (53.5 kg) CAW33 146 (66.4 kg) 169 (76.7 kg) CAW36 146 (66.4 kg) 169 (76.7 kg) CAW Airflow / Indoor Sound Levels Air Flow Indoor Sound Levels High Speed Low Speed High Speed Low Speed CFM CFM (dba) (dba) CAW08 360 300 41 39 CAW12 360 300 41 39 CAW18 650 550 44 42 CAW20 700 600 44 42 CAW33 950 750 51 49 CAW36 1100 900 51 49 5

CAW Cassette Air Handler CAW 4-Pipe Chilled Water with Hydronic Heat Mounts flush with ceiling, evenly distributing conditioned air. Only the facia assembly is visible. Great for conditioning rooms with drop ceilings. 8,000-36,000 Btuh Capacities 208-230V/1/60Hz Standard 115V/1/60Hz Available 220-240/1/50Hz Available No De-rate for 115V or 50Hz 6 Nominal Capacities 8,000 Btuh 20,000 Btuh 12,000 Btuh 33,000 Btuh 18,000 Btuh 36,000 Btuh 24 Vac Remote Thermostat Configuration (Thermostat Sold Separately) Infrared Handheld Remote Control Option (Remote Sold Separately) Washable Return Air Filter(s) Supply-Discharge Air Louvers 08/12k Btuh - Manually Adjustable 18-36k Btuh - Auto Sweep or Fixed Positions Stop Factory-Installed Condensate Pump (30" Lift) Fresh Air & Branch Duct Knockouts CAW 4-Pipe Cooling Performance (High Fan) Cooling Capacity Entering / Leaving Water Temperatures (No Glycol) Entering 40/50 F 45/55 F * Dry Bulb Air Temperature Total Sensible Flow Pressure Total Sensible Flow Pressure ( F) at Capacity Capacity Rate Drop Capacity Capacity Rate Drop 50% RH Btuh Btuh GPM Ft. H 2 0 Btuh Btuh GPM Ft. H 2 0 72 7,700 7,300 1.5 3.3 5,900 5,900 1.2 2.0 CAW08 75 9,100 8,000 1.8 4.5 7,200 6,900 1.4 2.9 80 12,900 9,400 2.6 8.6 9,600 8,100 1.9 4.9 72 10,500 8,900 2.1 1.9 7,400 7,200 1.5 0.9 CAW12 75 12,700 9,900 2.5 2.9 9,300 8,400 1.9 1.5 80 17,700 11,700 3.5 5.4 13,500 10,000 2.7 3.2 72 11,800 11,800 2.3 0.6 9,000 9,000 1.8 0.4 CAW18 75 15,900 14,300 3.2 1.0 10,700 10,700 2.1 0.5 80 24,000 17,700 4.8 2.5 18,000 15,100 3.6 1.3 72 12,300 12,300 2.4 0.6 9,300 9,300 1.9 0.4 CAW20 75 17,200 15,400 3.4 1.2 11,200 11,200 2.2 0.5 80 27,200 19,400 5.4 3.2 19,400 16,300 3.9 1.6 72 26,700 22,900 5.3 2.7 19,200 18,800 3.8 1.3 CAW33 75 33,300 25,800 6.6 4.4 23,900 21,700 4.8 2.2 80 50,300 32,400 10.0 9.4 36,800 26,700 7.3 5.2 72 30,500 26,300 6.1 3.7 21,900 21,500 4.4 1.8 CAW36 75 39,700 30,400 7.9 6.1 27,300 24,900 5.5 2.9 80 58,400 37,600 11.6 12.5 43,500 31,200 8.7 7.2 *Note: Please refer to specifications for the full model number when ordering and specifying equipment. 6

CAW Cassette Air Handler CAW 4-Pipe Cassette Electrical Specifications Fan Motor Electric Heat Total Min HACR M.C.A. Volts/Phase/Hertz RLA H.P. kw AMPS AMPS Volt BRKR CAW 08/12 115/1/60 0.9 1/10 N/A 0.9 104 1.2 15 CAW 08/12 208-230/1/60 0.35 1/10 0.4 197 0.5 15 60 HZ CAW 18/20 115/1/60 1.1 1/8 N/A 1.1 104 1.4 15 CAW 18/20 208-230/1/60 0.55 1/8 0.6 197 0.7 15 CAW 33/36 115/1/60 1.0, 1.0 1/10, 1/10 N/A 2.0 104 2.3 15 CAW 33/36 208-230/1/60 0.5, 0.5 1/10, 1/10 1.0 197 1.2 15 CAW 08/12 220-240/1/50 0.35 1/10 0.4 198 0.4 15 50 HZ CAW 18/20 220-240/1/50 0.55 1/8 0.6 198 0.7 15 CAW 33/36 220-240/1/50 0.5, 0.5 1/10, 1/10 1.0 198 1.3 15 CAW Technical Data Connections CAW 08/12 CAW 18/20 CAW 33/36 Chilled/Hot Water Inlet 5/8" 7/8" 7/8" Chilled/Hot Water Outlet 5/8" 7/8" 7/8" Condensate 1/2" 1/2" 1/2" Branch Duct Diameter 5" 5" 5" Fresh Air Duct Diameter 1 1 /2" x 2 1 /2" 3" x 3" 3" x 3" Filtration CAW 08/12 CAW 18/20 CAW 33/36 Type Quantity 1 Wire Framed Periframe 2 3 Arrestance 80% 80% 80% Condensate Pump CAW 08/12 CAW 18/20 CAW 33/36 Maximum Head 30" 30" 30" Nominal Flow Rate (Gpm) 0.1 0.1 0.1 CAW08 CAW12 CAW18 CAW20 CAW33 CAW36 CAW Hot Water 4-Pipe Cassette Capacities HOT WATER ENTERING TEMPERATURE 180 F Room Conditions 70 F DB 50% RH 70 F DB 50% RH 70 F DB 50% RH 70 F DB 50% RH 70 F DB 50% RH 70 F DB 50% RH Heating Capacity Btuh Water Flow GPM Leaving Water Temperature P.D. Ft. H 2 O 13,300 1.4 160 F 2.8 10,000 0.5 *140 F 0.5 17,000 1.8 160 F 1.6 13,500 0.7 140 F 0.5 29,800 3.2 160 F 2.8 22,500 1.2 140 F 0.2 30,800 3.5 160 F 2.8 23,200 1.2 140 F 0.2 49,500 5.4 160 F 8.3 37,800 2.1 140 F 2.3 53,900 5.6 160 F 9.2 40,600 2.2 140 F 2.3 *140 F Leaving Water Temperture data is in accordance with ANSI/AHRI Standard 440-2008. CAW Airflow / Indoor Sound Levels Air Flow Indoor Sound Levels High Speed Low Speed High Speed Low Speed CFM CFM (dba) (dba) CAW08 360 300 41 39 CAW12 360 300 41 39 CAW18 650 550 44 42 CAW20 700 600 44 42 CAW33 950 750 51 49 CAW36 1100 900 51 49 Shipping Weights 208-230V & 220-240V 115V Lbs. (kg Lbs. (kg) CAW08 76 (34.5 kg) 86 (39.0 kg) CAW12 76 (34.5 kg) 86 (39.0 kg) CAW18 115 (52.2 kg) 125 (56.7 kg) CAW20 115 (52.2 kg) 125 (56.7 kg) CAW33 175 (79.4 kg) 185 (83.9 kg) CAW36 175 (79.4 kg) 185 (83.9 kg) 7

CCP Ceiling-Suspended Air Handler 2-Pipe Chilled Water - Optional Electric Heat 4-Pipe Chilled Water with Hydronic Heat Positioned anywhere on the ceiling, unit will easily condition larger areas. A perfect alternative to open up wall and floor space. 9,000-48,000 Btuh Capacities 208-230V/1/60Hz Standard 115V/1/60Hz Available 220-240/1/50Hz Available Four Chassis Sizes 12 - (~9/12k Btuh) 24 - (~18/24k Btuh) 30 - (~30k Btuh) 48 - (~36/42/48k Btuh) 24 Vac Remote Thermostat Configuration, Standard (Thermostat Sold Separately) Unit Mounted Keypad Control with Optional Infrared Handheld Remote Control 2-Pipe Applications allow for Optional E-Boost Electric Heat: 3kW - 9/12k Btuh 5kW - 18/24/30k Btuh 7kW - 36/42/48k Btuh 4-Pipe Applications, Hydronic Cooling & Heating Adjustable, Plastic Discharge Air Grille Field-Installed Condensate Pumps (Optional) Shelf/Floor Mount or Internally Mounted Washable Return Air Filter(s) * CCP12 CCP24 CCP30 CCP48 Cooling Capacity Fluid Temperature CCP 2-Pipe Cooling Performance (High Fan) All Capacities Based on 80 F Dry Bulb / 67 F Wet Bulb Entering Air Temperature Total Sensible Flow Pressure ( F) Capacity Capacity Rate Drop Btuh Btuh GPM Ft. H 2 0 45 7,800 7,300 1 3.0 45 10,900 8,800 2 5.3 45 13,300 9,800 3 8.8 40 9,000 7,800 1 3.0 40 12,700 9,500 2 5.3 40 15,600 10,700 3 8.8 45 17,400 15,000 3 3.4 45 22,500 17,200 5 10.1 40 19,000 15,100 3 3.4 40 26,600 19,700 5 10.1 45 21,600 17,000 3 4.8 45 26,750 19,500 4.5 10.2 45 29,500 20,600 6 17.2 40 25,000 18,600 3 4.8 40 31,000 21,500 4.5 10.2 40 35,000 23,000 6 17.2 45 34,512 28,430 4 6.4 45 42,872 32,080 6 13.3 45 47,364 33,977 8 22.6 40 39,081 30,341 4 6.4 40 49,981 35,067 6 13.5 40 56,292 37,832 8 22.8 *Note: Please refer to specifications for the full model number when ordering and specifying equipment. Optional Electric Heat (@ 230V) 3.0 kw 5.0 kw 7.0 kw 8

CCP Ceiling-Suspended Air Handler CCP Electrical Specifications (No Electric Heat) CCP Water Connections 09/12 18/24 24/30 36/42/48 Cabinet Cabinet Cabinet Cabinet Chilled Water 5/8" OD 3/4" OD 3/4" OD 7/8" OD Inlet 1/2" ID 5/8" ID 5/8" ID 3/4" ID Chilled Water 5/8" OD 3/4" OD 3/4" OD 7/8" OD Outlet 1/2" ID 5/8" ID 5/8" ID 3/4" ID Hot Water 1/2" OD 1/2" OD 1/2" OD 1/2" OD Inlet 3/8" ID 3/8" ID 3/8" ID 3/8" ID Hot Water 1/2" OD 1/2" OD 1/2" OD 1/2" OD Outlet 3/8" ID 3/8" ID 3/8" ID 3/8" ID Drain Size Fan Motor Min Min Max Volts/Phase/Hertz FLA Volt Ampacity 1 Fuse 1 CCP12 115/1/60 1.4 104 1.8 15 CCP12 208-230/1/60 0.6 197 0.8 15 CCP12 220-240/1/50 0.67 198 0.8 15 CCP24 208-230/1/60 1.1 197 1.4 15 CCP30 208-230/1/60 1.1 197 1.4 15 CCP24/30 220-240/1/50 1.1 198 1.4 15 CCP48 208-230/1/60 1.1/1.1 197 2.5 15 CCP48 220-240/1/50 1.1 198 2.5 15 (1) If electric heaters are installed, use Min Amp and Max Fuse from Heater Option Chart. 5/8" OD 5/8" OD 5/8" OD 5/8" OD 1/2" ID 1/2" ID 1/2" ID 1/2" ID CCP Airflow / Indoor Sound Levels Air Flow Indoor Sound Levels 230V, High Fan Speed, Dry Coil @ 230V High Speed CFM FPM Throw/Ft. (dba) CCP With Electric Heat Options Voltage kw Heater Total Min. Cir. Max. Amps Amps Amps Fuse CCP12 208-230 3 13.1 13.7 17.1 20 CCP12 220-240 3 13.6 14.3 17.8 20 CCP24 208-230 5 21.7 22.8 28.6 30 CCP30 208-230 5 21.7 22.8 28.6 30 CCP24/30 220-240 5 22.7 23.8 29.8 30 CCP48 208-230 7 30.4 32.6 40.8 45 CCP48 220-240 7 31.75 34.0 42.5 45 CCP12 CCP24 CCP30 CCP48 4-Pipe Hydronic Heat Data EWT P. Drop GPM Capacity F Ft H 2 O Shipping Weights CCP12 CCP24/30 CCP48 140 2 14,500 3.4 160 2 22,900 3.4 140 4 27,200 5.2 160 4 43,200 5.2 140 4 29,800 5.2 160 4 47,300 5.2 140 4 40,300 6.1 160 4 64,100 6.1 Shipping Weight Lbs. (kg) 115 (52.2 kg) 135 (61.2 kg) 160 (72.6 kg) CCP12 350 290 12.4 46.3 CCP24 650 430 18.6 50.8 CCP30 800 533 18.6 56 CCP48 1,200 500 19.0 64.2 Fan Operation: Auto-High-Low 9

WCP High Wall Air Handler 2-Pipe Chilled Water - Optional Electric Heat Installed near the ceiling, circulates conditioned air smoothly while providing high efficiency conditioning for desired room comfort. 9,000-30,000 Btuh Capacities 208-230V/1/60Hz Standard 115V/1/60Hz Available 220-240/1/50Hz Available Three Chassis Sizes: 12 - (~9/12k Btuh) 18 - (~15/18k Btuh) 30 - (~24/30k Btuh) Adjustable, Plastic Discharge Air Grille Field-Installed Condensate Pump (Optional) 2-Pipe Applications allow for Optional E-Boost Electric Heat: 3kW - 9/12/15/18k Btuh 5kW - 24/30-5kW 24 Vac Remote Thermostat Configuration, Standard Unit Mount Controls Option Infrared Handheld Remote Control Available Washable Return Air Filter(s) WCP 2-Pipe Cooling Performance (High Fan) Cooling Capacity All Capacities Based on High Speed Fan and 80 F Dry Bulb / 67 F Wet Bulb Entering Air Temperature * Entering Dry Bulb Air Temperature Total Sensible Flow Pressure Capacity Capacity Rate Drop ( F) at 50% RH Btuh Btuh GPM Ft. H 2 0 45 7,375 6,732 1 0.8 45 10,801 8,272 2 3.8 WCP12 45 13,270 9,279 3 8.0 40 8,387 7,189 1 0.8 40 12,481 8,950 2 3.9 40 15,643 10,304 3 8.1 45 15,624 13,477 2 4.4 WCP18 45 19,761 15,367 3 9.1 40 17,724 14,379 2 4.5 40 23,073 16,763 3 9.3 45 20,563 17,564 3 2.3 45 29,031 21,178 6 8.3 45 32,320 22,539 9 17.7 WCP30 40 23,600 18,887 3 2.4 40 34,400 23,423 6 8.4 40 38,790 25,351 9 17.9 *Note: Please refer to specifications for the full model number when ordering and specifying equipment. Optional Electric Heat (208/230V) 3.0 kw 5.0 kw 10

WCP High Wall Air Handler WCP Electrical Specifications Fan Motor Total Min Min Max Volts/Phase/Hertz FLA H.P. AMPS Volt Ampacity 1 Fuse 1 WCP12A 115/1/60 0.64 0.03 0.64 104 0.8 15 WCP12A 208-230/1/60 0.34 0.02 0.34 197 0.43 15 WCP12F 220-240/1/50 0.34 0.02 0.3 197 0.43 15 WCP18A 115/1/60 1.2 0.083 1.2 104 1.5 15 WCP18D 208-230/1/60 0.56 0.07 0.56 197 0.7 15 WCP18F 220-240/1/50 0.56 0.07 0.56 197 0.7 15 WCP30A 115/1/60 1.2 0.083 1.2 104 1.5 15 WCP30D 208-230/1/60 0.56 0.07 0.56 197 0.7 15 WCP30F 220-240/1/50 0.56 0.07 0.56 197 0.7 15 (1) If electric heaters are installed, use Min Amp and Max Fuse from Heater Option Chart. WCP With Electric Heat Options Voltage kw Heater Total Min. Cir. Max. Amps Amps Amps Fuse WCP12 230 3 13.1 13.4 16.7 20 WCP12 240 3.2 13.6 13.9 17.4 20 WCP18 230 3 13.1 13.6 17 20 WCP18 240 3.2 13.6 14.2 17.7 20 WCP30 230 5 21.7 22.3 27.9 30 WCP30 240 5.4 22.7 23.3 29.1 30 Shipping Weights Shipping Weight Lbs. (kg) WCP12 85 (38.6 kg) WCP18 115 (52.2 kg) WCP30 115 (52.2 kg) WCP Water Connections Small Cabinet Medium Cabinet Large Cabinet 12 18 30 Chilled Water 5/8" OD 3/4" OD 3/4" OD Inlet 1/2" ID 5/8" ID 5/8" ID Chilled Water 5/8" OD 3/4" OD 3/4" OD Outlet 1/2" ID 5/8" ID 5/8" ID Drain Size 5/8" OD 5/8" OD 5/8" OD 1/2" ID 1/2" ID 1/2" ID WCP Airflow / Indoor Sound Levels Air Flow Indoor Sound Levels 230V, High Fan Speed, Dry Coil @ 230V High Speed CFM FPM Throw/Ft. (dba) WCP12 310 960 16 48 WCP18 600 1412 26 51 WCP30 750 1400 25 54 Fan Operation: Auto-High-Low 11

Presents Chilled/Hydronic Ductless Air Handlers For complete product information, please refer to individual unit specifications, installation and operation manual, and other product literature found on www.enviromaster.com. Due to on-going product development, specifications are subject to change without notice. Contractor Assistance: 800.325.5479 2201 Dwyer Avenue Utica, New York 13501 Phone: 800.325.5479 Web: enviromaster.com PN 240010214 Rev. C 7/15