Prime Chiller Mini-Chillers

Similar documents
Prime Chiller 1/10th HP Chiller

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Prime Chiller Modular Upgradable Chiller

gamma pond Ultraviolet Sterilizers

nova extreme retrofit High Output T5 Lighting Kit

MIGHTY PRO 1/4 HP CHILLER

Air Pump Up to 800 gallons

16" and 20" Economy Incandescent Full Hoods Owner s Manual

Lighting Placement. Adjusting Mounting Legs

100 Series Maxi Internal Filters

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

Clamp 4W Clamp 8W. Owner s Manual

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

Owner s Manual Compact Fluorescent Lunar Aqualight

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

CHAETOMAX. 2 in 1 Refugium LED. Owner s Manual 1

Installation & Maintenance Guide

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

LINEAR AIR PUMPS INSTRUCTION MANUAL SERIES PRO TM

Manuel Guide Lighting Fixtures

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

aquamanta the experts in aquatic technology

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

Important Safety Instructions 3-4

OmniDry 2.9 Amp Centrifugal Air Mover

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Pressurized Filter Up to 1250 gallons

PROFESSIONAL CURLING IRON with adjustable temperature settings and Auto Shut Off after 60 minutes

Installation Instructions PP-AS20 Anti-Scale System

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Chilller Arctic Instruction Manual

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Heater Upgrade Instructions

HYDROFILL ATO Controller System

Projection Alarm Clock USER GUIDE

SR-60 SR-80 SR-120. Owner s Manual 1

Owner s Manual Hydro-X Vacuum Pac

MiniMax Sump #7304. Owner s Manual 1

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

User s Manual & Operating Instructions


Instruction Leaflet. Read instructions before operating. Retain for future reference.

Register your product within 30 days of purchase to activate its one-year

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

AquaReef Cube. Inspiring Excellence in Fish Keeping!

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Tower Fan MODEL# EE-5607

Quest PowerHeat HFC 100 Pro

20 High Velocity Fan with 135 Tilt Head

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

16 Stand Fan with Remote Control Model No: FS3-40R-30

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

SimplyClear Pressurized Filter Product Manual

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

INSTALLATION AND INSTRUCTION MANUAL

Ozone + UV Sanitation

Owner s Manual. Terpene Trap CF 1000

WA A Aqua Sub Bottom-load Water Cooler

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

SAVE THESE INSTRUCTIONS

PORTABLE DEHUMIDIFIER

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Fold Here. Stamp. Transworld Aquatic Enterprises, Inc 3730 W. Century Blvd #3 Inglewood, CA Phone: (877) JBJLIGHTING.

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

(The chances are you re never going to read me) Owner s Manual. Model S10E.

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Owner s Manual Phoenix Aquadry TX 200

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Stand Fan. English. Owner s Guide. Model F R

Phoenix AirMAX - Radial Air Mover

18 INCHES, OSCILLATING STAND FAN

20 INCH ELECTRIC GRIDDLE

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

A2Z Ozone, Inc. PRODUCT MANUAL

Professional Warming Drawer and Warming Drawer Cabinet

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

E-Flow Pumps. Operating instructions

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Table of Contents Important Safeguards 2 Introduction 3 Installation 4 Operation 5 Cleaning Pattern 5 Automatic Shutoff and Removal 6 Maintenance 6

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Sound Cover [ , , , ]

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

READ AND SAVE THESE INSTRUCTIONS. Vacuum Food Storage System Reference Guide. Space Saving Design.

HI Industrial Utility Heater HI Soleus Air International

Towel Warmer. Luxurious warmth for towels, robes and blankets

20" Air Circulator MODEL: FB50-9HA

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Power Electric Heat EHS 62 Pro

OZX-300ST Ozone Generator

IMPORTANT SAFEGUARDS

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

Whynter Portable Ice Maker 33 lb capacity - White

Thin Window FAN With Comfort Control Thermostat. Instruction Leaflet. pure indoor living MODEL: BWF0522M-CN

Dehumidifiers. Déhumidificateur. Deshumedificador. GEAppliances.com. Safety Instructions... 2, 3. Owner s Manual

Compact Refrigerator. User Manual Model 3590A

(The chances are you re never going to read me) Owner s Manual.

Spa Control System OWNER S MANUAL

Transcription:

Prime Chiller Mini-Chillers Instructions for Model#2680, 2635 Warning and Safety Instructions... Page 2 Chiller Installation... Page 3 Programming Thermostat... Page 4 Warranty... Page 5 EMAIL:INFO@CURRENT-USA.COM

Safety Instructions WARNING To guard against injury, basic safety precautions should be observed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS DANGER To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself. Return the appliance to your retailer or discard the appliance. If the appliance falls into the water, or water drips onto the unit, DON T reach for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately. Always unplug appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug fully and pull out to disconnect. Carefully examine the appliance after replacement. It should not be plugged in if there is water on parts not intended to be wet. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner. If you are using the ultraviolet sterilizer or heater upgrade do not operate the unit without continual water flow. If you are using the heater option ensure that the heater is plugged into the thermostat that is supplied with the water chiller. Exposing chiller/power cords to water may cause electrical short and fire. Do not allow water or salt to come in contact with thermostat or power cords. Do not operate chiller without water flow to the unit. This may cause the evaporator housing to freeze up and result in damage to the unit. SAVE THESE INSTRUCTIONS GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code (NFPA 70), and to provide additional protection from the risk of shock, this unit MUST be connected to a ground fault circuit interrupter (GFCI) outlet at all times. Do not use extension cords. WARNING To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands.

Chiller installation Pre-Installation Before removing your Prime Chiller from the box, please note any exterior shipping damage to the box. It is strongly recommended to keep the box and packaging material in the unlikely event there is shipping damage or service is required. Remove the chiller from the box and inspect thoroughly for any signs of damage, even if the box does not show damage. If you notice any damage (cracked or bent cover, damaged condenser fins, etc.) please stop and contact your dealer immediately. Installation 1. Remove accessories and plumbing fittings for inlet and outlet. 2. Slide chiller from box and inspect for damages. 3. Place chiller in desired location. Make sure the chiller is placed on a firm, level surface in a location that has plenty of ventilation and will not be exposed to salt or saltwater. The requirements for ventilation are: a) Back/Sides: Condenser (radiator) requires at least 24 clearance to allow air into the chiller. b) Front: Requires at least 24 clearance to allow for proper air flow. c) Chiller must not be placed in a closed closet or cabinet. d) The warm air from the chiller must be completely evacuated from the chiller location. A fan may be necessary to draw warm air away from the chiller. The maximum operating temperature is 95 F. 4. Assemble the water inlet and outlet to the chiller. Ensure the seal ring is properly seated. 5. Connect external flexible hoses to the inlet and outlet. After connecting hoses, tighten the metal screw clamps to ensures hoses do not disconnect when in use. 6. Before turning on chiller, ensure the following: a) Flow water through the chiller for approximately 30 minutes to ensure there is no water leakage. b) Make sure the pump will operate normally without any blockage. c) Make sure the chiller is plugged into a GFCI protected 110V power outlet. 7. Set the temperature controller to the desired temperature as instructed next.

programming thermostat CHILLER TEMPERATURE ADJUSTMENT 1. Plug the chiller into the GFCI protected outlet. The power switch will come on and the digital controller with display the actual water temperature. The POWER light will illuminate. 2. Press SET to set the desired temperature. Press > to increase temperature and press < to decrease temperature. The default temperature differential is 2 F, therefore the chiller will begin to operate at a temperature that is 2 F less than the actual water temperature. 3. The digital display will resume showing the water temperature after a 5 second delay. The chiller will then enter a delayed start-up mode, which lasts 2-3 minutes, after which will begin normal operation. 4. Setting the temperature differential (Model : a) Press SET for ten seconds. The letter d will jump on the digital display indicating that the adjusting function is in a ready state. b) Press the > or < to adjust the starting temperature differential. The differential can be adjusted from 2 F to 3 F or 4 F. Heater control system 1. The Prime chiller features an external heater port that allows any 110V submersible aquarium heater up to 300 watts to be controlled by the chillers temperature controller. It is recommended to set both the temperature controller on the heater and on the chiller to the same temperature. 2. Install the submersible heater into the sump or aquarium. Ensure that a drip loop is in place so that water cannot drip into the heater port. 3. Plug the heater into the port on the back of the chiller. The default temperature differential is 2 F, therefore the heater will begin to operate at a temperature that is 2 F lower than the set water temperature.

Warranty Current USA, Inc. One-Year Limited Warranty Current USA, Inc. warrants this product against defects in materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase. Light Bulbs carry a 3 month warranty. Note: Current-USA, Inc. One-Year Limited Warranty does not cover damage caused by the following: Improper installation, saltwater corrosion, and electrical surges. If you discover a defect, Current USA, Inc. will, at it s option, repair or replace the product at no charge to you, provided you return it during the warranty period. It is required that you present this warranty card and a copy of the bill of sale as proof of original purchase date, in the event the product needs repairs, within the warranty period. Please see your dealer for return options. This warranty applies only to products by or for Current USA, Inc. that can be identified by trade name, or logo affixed to them. Current-USA, Inc. does not warrant any products that are not Current-USA, Inc. products. This warranty does not apply if the product has been damaged by accident, abuse, misuse or misapplication or if the product has been modified without the written permission of Current-USA, Inc.; or if any Current-USA, Inc. logos have been removed or defaced. THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. Current USA, Inc. SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF EQUIPMENT AND PROPERTY, AND ANY COSTS OF RECOVERING ANIMALS, PLANTS, TANKS OR OTHER AQUARIUM RELATED ITEMS AND/OR EQUIPMENT. Current USA, Inc. IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY, OR REPLACEMENT OF EQUIPMENT OR PROPERTY, OR ANY COSTS OF RECOVERING OR REPRODUCING ANY EQUIPMENT, ANIMALS OR PLANTS USED OR GROWN WITH Current USA, Inc. PRODUCTS. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied warranties, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary form jurisdiction to jurisdiction.