MULTIKWIK SEWER SYSTEMS MULTIKWIK WC PAN CONNECTORS

Similar documents
Agrément Certificate 92/2841 website: Product Sheet 1

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

PTSPAS Product Assessment Certificate in accordance with Equivalent Scheme MCHW SHW Volume 1 Clause and

Regulations, Legislation and Byelaws

Loss Prevention Standard

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Loss Prevention Standard

NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM NAYLOR METRODRAIN TWINWALL HIGHWAY DRAINAGE SYSTEM 150 MM TO 750 MM PIPES AND COUPLERS

European Technical Assessment ETA-14/0176

Standards and third party certification

Certificate No: EWS534

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Loss Prevention Standard

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Australian/New Zealand Standard

DVS HOME VENTILATION SYSTEMS. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 375 [2014]

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

ACCREDITATIONS. MEMBERSHIPS & AWARDS. Quality counts, don t settle for anything less... BSI Kitemark for energy rated windows

Technical Bulletin CE marking: from 1st July 2013

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Testing coated fabrics

Microgeneration Certification Scheme: MCS 008

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Guidance Note No 19/1. CE Marking windows and doorsets

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Australian/New Zealand Standard

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

GASTEC QA. Approval Requirements 69-1

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Hardware for Sliding Doors & Folding Doors

Australian/New Zealand Standard

Electrical Safety Policy and Management System

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Fire Performance of external thermal insulation for walls of multistorey buildings

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08

Australian/New Zealand Standard

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Kenya s Official Distributor of GutterFlow Products

GASTEC QA. Approval Requirements 31-1

Installation and Servicing Instructions

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Mechanically operated locks and locking plates

CE marking & your legal obligations

Fire prevention and protection

AS/NZS 4012:1999 AS/NZS

Consumer unit replacement in domestic and similar premises

EN transition from BS 1387 Structural & Conveyance Business

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

Fire prevention and protection

Electrical Safety Policy

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

GASTEC QA. Approval Requirements 136

HVCA. Guide to Good Practice. Heating and Ventilating Contractors Association. Mothballing and Re-commissioning of Buildings SFG30

Controlled Door Closing Devices

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Water Supply (Water Fittings) Regulations 1999

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

volume 11 environmental assessment section 2 environmental impact assessment Part 4 ha 204/08 scoping of environmental impact assessments

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

Australian/New Zealand Standard

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Building Investigation & Testing Services

FINAL DRAFT FprEN

WORLDWIDE CABLE EXPERTS

This document is a preview generated by EVS

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

General safety precautions English

Design & Construction Standards, Revised January

CE MARKING OF WOOD-BASED PANELS

This document is a preview generated by EVS

WC2 & WC3 Installation & Maintenance Instructions

Australian/New Zealand Standard

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Record of Amendments. Version Date Amendment Section/page affected

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

AS/NZS :2016

SUMET09 Maintain electrical systems and equipment (SQA Unit Code- H956 04)

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

volume 11 environmental assessment section 2 environmental impact assessment Part 2 ha 202/08 environmental impact assessment

AS/NZS :2008

SUMET05 Install and connect electrical cables, conductors, wiring systems and equipment

Transcription:

DHM Plastics Ltd Dickley Lane Lenham Maidstone Kent ME17 2DE Tel: 01622 858888 Fax: 01622 858725 e-mail: info@multikwik.com website: www.multikwik.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 88/2107 Product Sheet 1 This Agrément Certificate Product Sheet (1) relates to a range of Multikwik WC Pan Connectors, for use with British and European Standard WC pans and pipes. (1) Hereinafter referred to as Certificate. CERTIFICATION INCLUDES: factors relating to compliance with Building Regulations where applicable factors relating to additional non-regulatory information where applicable independently verified technical specification assessment criteria and technical investigations design considerations installation guidance regular surveillance of production formal three-yearly review. MULTIKWIK SEWER SYSTEMS MULTIKWIK WC PAN CONNECTORS KEY FACTORS ASSESSED Gas and watertightness the products will have adequate gas and watertightness (see section 6). Resistance to chemicals the products will have adequate resistance to chemicals (see section 7). Durability the products will have a life expectancy in excess of 30 years (see section 9). The BBA has awarded this Certificate to the company named above for the products described herein. These products have been assessed by the BBA as being fit for their intended use provided they are installed, used and maintained as set out in this Certificate. On behalf of the British Board of Agrément Date of Second issue: 4 September 2013 Brian Chamberlain Claire Curtis-Thomas Originally certificated on 31 October 1988 Head of Approvals Engineering Chief Executive The BBA is a UKAS accredited certification body Number 113. The schedule of the current scope of accreditation for product certification is available in pdf format via the UKAS link on the BBA website at www.bbacerts.co.uk Readers are advised to check the validity and latest issue number of this Agrément Certificate by either referring to the BBA website or contacting the BBA direct. British Board of Agrément tel: 01923 665300 Bucknalls Lane fax: 01923 665301 Watford e-mail: mail@bba.star.co.uk Herts WD25 9BA 2013 website: www.bbacerts.co.uk Page 1 of 7

Regulations In the opinion of the BBA, Multikwik WC Pan Connectors, if installed, used and maintained in accordance with this Certificate, will meet or contribute to meeting the relevant requirements of the following Building Regulations (the presence of a UK map indicates that the subject is related to the Building Regulations in the region or regions of the UK depicted): The Building Regulations 2010 (England and Wales) (as amended) Requirement: H1 Foul water drainage The products will meet this Requirement. See sections 6 to 8 of this Certificate. Regulation 7 Materials and workmanship The products are acceptable. See section 9 and the Installation part of this Certificate. The Building (Scotland) Regulations 2004 (as amended) Regulation: 8(1)(2) Fitness and durability of materials and workmanship The products are acceptable. See sections 8 and 9 and the Installation part of this Certificate. Regulation: 9 Building standards applicable to construction Standard: 3.7(b) Wastewater drainage The products will meet the relevant requirements of this Standard, with reference to clause 3.7.1 (1)(2). See sections 6 to 8 of this Certificate. Standard: 7.1(a)(b) Statement of sustainability The products can contribute to meeting the relevant Requirements of Regulation 9, Standards 1 to 6 and therefore will contribute to a construction meeting a bronze level of sustainability as defined in this Standard. (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). The Building Regulations (Northern Ireland) 2012 Regulation: 23(a)(i)(b)(i)(ii) Fitness of materials and workmanship The products are acceptable. See section 9 and the Installation part of this Certificate. Regulation: 80(a)(i)(b) Sanitary pipework The products will meet the requirements of this Regulation. See sections 6 to 8 of this Certificate. Construction (Design and Management) Regulations 2007 Construction (Design and Management) Regulations (Northern Ireland) 2007 Information in this Certificate may assist the client, CDM co-ordinator, designer and contractors to address their obligations under these Regulations. See section: 3 Delivery and site handling (3.1) of this Certificate. Additional Information NHBC Standards 2013 NHBC accepts the use of Multikwik WC Pan Connectors, when installed and used in accordance with this Certificate, in relation to NHBC Standards, Chapter 8.1 Internal services. Page 2 of 7

Technical Specification 1 Description 1.1 Multikwik WC Pan Connectors (see Figure 1) are moulded from white EVA (ethylene vinyl acetate) copolymer. The socket and spigot on connectors, Size Nos 1, 2, 1 (offset), 1/14, 21/90, 31/90 and 21/104, are fitted with elastomeric sealing rings. Figure 1 Multikwik connectors assessed (showing normal seal positions) 1.2 The spigot ends of these fittings, and of the extension piece (Ext A), are multi-finned. The latter does not have a socket end, connection being made with a suitable connector. 2 Manufacture 2.1 The connector bodies are produced by injection moulding and the sealing rings by injection moulding or by heated compression moulding. 2.2 As part of the assessment and ongoing surveillance of product quality, the BBA has: agreed with the manufacturer the quality control procedures and product testing to be undertaken assessed and agreed the quality control operated over batches of incoming materials monitored the production process and verified that it is in accordance with the documented process evaluated the process for management of nonconformities checked that equipment has been properly tested and calibrated undertaken to carry out the above measures on a regular basis through a surveillance process, to verify that the specifications and quality control operated by the manufacturer are being maintained. 2.3 The management system of DHM Plastics Ltd has been assessed and registered as meeting the requirements of BS EN ISO 9001 : 2008 by BSI (Certificate FM 30637). 3 Delivery and site handling 3.1 Connectors are packed in polythene bags, with a sachet of lubricant and a leaflet or label bearing the connector size number, fitting instructions and the BBA identification mark incorporating the number of this Certificate. 3.2 Connectors should not be allowed to come into contact with mineral oil, grease, putty or any compound containing mineral oil or grease, and should be protected from direct sunlight and naked flames. Assessment and Technical Investigations The following is a summary of the assessment and technical investigations carried out on Multikwik WC Pan Connectors. Page 3 of 7

Design Considerations 4 General 4.1 The Multikwik WC Pan Connectors covered by this Certificate are satisfactory for the following purposes (see also Table 1): Size Nos 1, 1 (offset) and 21/104 for use with WC pans with S or P traps to BS EN 997 : 2012, BS EN 33 : 2011 and BS EN 37 : 1999 Size Nos 1/14, 2, 21/90 and 31/90 for use with WC pans to BS EN 33 : 2011, BS EN 37 : 1999, BS 5504-1 : 1977 and BS 5504-2 : 1977. Table 1 Application details Size No Description Outside diameter of WC pan spigot (mm) Part No 1 Straight connector 108 114 (1) MKS1 2 Straight connector 97 108 (2) MKS2 1 18 mm Offset 108 114 (1) MK01 21/90 Short 90 bend 97 108 (2) MKB2190 31/90 Long 90 bend 97 108 (2) MKB3190 21/104 104 bend 97 108 (2) MKB21104 1/14 14 bend 97 108 (2) MKB114 Ext A Extension piece MKEA (1) WC pans to BS EN 33 : 2011, BS EN 37 : 1999 and BS EN 997 : 2012. (2) WC pans to BS EN 33 : 2011 and BS EN 37 : 1999. (3) WC pans to BS EN 33 : 2011, BS EN 37 : 1999 and BS EN 997 : 2012 up to 111 mm outside diameter pan spigot and BS EN 33 : 2011 and BS EN 37 : 1999. 4.2 All the connectors are for use in providing a flexible link from the spigot, within the tolerance range of outside diameters given in Table 1, to soil pipes 110 mm PVC-U to BS EN 1401-1 : 2009 and BS EN 1329-1 : 2000, 102 mm clay to BS 65 : 1991 and 102 mm cast iron to BS EN 877 : 1999 + A1 : 2006 and BS 437 : 2008. 4.3 The extension piece (Ext A), when used with connectors covered by this Certificate, provides a suitable means of bridging a gap of up to 200 mm between the appropriate connectors and the soil pipe. Under no circumstances should the extension piece (Ext A) be connected directly to the WC pan. 5 Practicability of installation The products are designed to be installed by a competent general builder, or a contractor, experienced with this type of system. 6 Gas and watertightness Joints from WC pans to connectors and from connectors to soil pipes will remain watertight and gastight under conditions of deflection, partial withdrawal and thermal movement in excess of those likely to occur in practice. 7 Resistance to chemicals The effluent and cleaners normal to WC systems will not affect the materials used for the connectors or the sealing rings. 8 Maintenance The WC pan can be removed, without damage to pan or connector, to enable pipe blockages to be cleared or the pan to be renewed. 9 Durability There will be no significant deterioration of the connectors or sealing rings under normal service conditions. In the opinion of the BBA, the connectors will have a life expectancy in excess of 30 years. Page 4 of 7

Installation 10 Procedure 10.1 Installation must be in accordance with the manufacturer s fitting instructions, supplied with every connector. Only the recommended lubricant, supplied with the product, should be used. 10.2 The soil pipe must be reasonably clean and smooth on the inner surface. The connector socket is pushed fully home onto the pan spigot. If necessary, the soil pipe is lubricated and the connector spigot pushed into it. Lubricant must never be applied to the pan spigot. 10.3 For clay and cast-iron pipes, where the internal diameters of these pipes are still within the relevant British Standard range of tolerances, but greater than 102 mm or significantly less than 102 mm such that the connections will be difficult to make, other fittings are available from the manufacturer, but these have not been assessed by the BBA. 10.4 If difficulty is encountered in fitting the connector, it may be immersed in hot water (maximum 60 C) to soften the material. 10.5 It is essential that the sealing rings are in the positions shown in Figure 1 and that the fins take up the positions shown in Figure 2, to produce a good seal between connector and soil pipe. Figure 2 Position of seals when correctly installed Technical Investigations 11 Tests Tests were carried out to determine: wall thickness to BS 5627 : 1984 ease of installation air and watertightness when correctly installed in accordance with BS 5627 : 1984 degree of misalignment to cause leakage air and watertightness after maximum compression set, likely to occur in use, had been induced in the sealing ring. 12 Investigations 12.1 Regular factory inspections have been carried out to ensure that quality is being maintained. 12.2 A user survey was carried out to evaluate performance in use. 12.3 An examination was made of data relating to: material properties dimensional accuracy chemical resistance practicability of installation durability. Page 5 of 7

Bibliography BS 65 : 1991 Specification for vitrified clay pipes, fittings and ducts, also flexible mechanical joints for use solely with surface water pipes and fittings BS 437 : 2008 Specification for cast iron drain pipes, fittings and their joints for socketed and socketless systems BS 5504-1 : 1977 Wall hung WC pan Wall hung WC pan with close coupled cistern Connecting dimensions BS 5504-2 : 1977 Wall hung WC pan Wall hung WC pan with independent water supply Connecting dimensions BS 5627 : 1984 Specification for plastics connectors for use with horizontal outlet vitreous china WC pans BS EN 33 : 2011 WC pans and WC suites Connecting dimensions BS EN 37 : 1999 Pedestal WC pans with independent water supply Connecting dimensions BS EN 877 : 1999 Cast iron pipes and fittings, their joints and accessories for the evacuation of water from buildings Requirements, test methods and quality assurance BS EN 997 : 2012 WC pans and WC suites with integral trap BS EN 1329-1 : 2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Unplasticized poly(vinyl chloride) (PVC-U) Specifications for pipes, fittings and the system BS EN 1401-1 : 2009 Plastic piping systems for non-pressure underground drainage and sewerage Unplasticized poly(vinyl chloride) (PVC-U) Specifications for pipes, fittings and the system Page 6 of 7

Conditions of Certification 13 Conditions 13.1 This Certificate: relates only to the product/system that is named and described on the front page is issued only to the company, firm, organisation or person named on the front page no other company, firm, organisation or person may hold or claim that this Certificate has been issued to them is valid only within the UK has to be read, considered and used as a whole document it may be misleading and will be incomplete to be selective is copyright of the BBA is subject to English Law. 13.2 Publications, documents, specifications, legislation, regulations, standards and the like referenced in this Certificate are those that were current and/or deemed relevant by the BBA at the date of issue or reissue of this Certificate. 13.3 This Certificate will remain valid for an unlimited period provided that the product/system and its manufacture and/or fabrication, including all related and relevant parts and processes thereof: are maintained at or above the levels which have been assessed and found to be satisfactory by the BBA continue to be checked as and when deemed appropriate by the BBA under arrangements that it will determine are reviewed by the BBA as and when it considers appropriate. 13.4 The BBA has used due skill, care and diligence in preparing this Certificate, but no warranty is provided. 13.5 In issuing this Certificate, the BBA is not responsible and is excluded from any liability to any company, firm, organisation or person, for any matters arising directly or indirectly from: the presence or absence of any patent, intellectual property or similar rights subsisting in the product/system or any other product/system the right of the Certificate holder to manufacture, supply, install, maintain or market the product/system actual installations of the product/system, including their nature, design, methods, performance, workmanship and maintenance any works and constructions in which the product/system is installed, including their nature, design, methods, performance, workmanship and maintenance any loss or damage, including personal injury, howsoever caused by the product/system, including its manufacture, supply, installation, use, maintenance and removal any claims by the manufacturer relating to CE marking. 13.6 Any information relating to the manufacture, supply, installation, use, maintenance and removal of this product/ system which is contained or referred to in this Certificate is the minimum required to be met when the product/system is manufactured, supplied, installed, used, maintained and removed. It does not purport in any way to restate the requirements of the Health and Safety at Work etc. Act 1974, or of any other statutory, common law or other duty which may exist at the date of issue or reissue of this Certificate; nor is conformity with such information to be taken as satisfying the requirements of the 1974 Act or of any statutory, common law or other duty of care. British Board of Agrément tel: 01923 665300 Bucknalls Lane fax: 01923 665301 Watford e-mail: mail@bba.star.co.uk Herts WD25 9BA 2013 website: www.bbacerts.co.uk Page 7 of 7