PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Similar documents
PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

TRUSTED PERFORMANCE. Carbon Dioxide Fire Suppression Systems

Hospitals and Major Medical Centers

Safe, Effective, Environment-friendly

Fire suppression systems for server rooms and data centres

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

FIRE SUPPRESSION SYSTEM

How can I protect invaluable assets and the environment from the effects of a fire?

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

BOC FS125 The Fire Extinguishing Solution

CO2 COCO GAS FLOODING SYSTEM

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

KD Innovative extinguishing with Novec TM 1230 by 3M TM

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Certificate of Conformity Certificate num. Registration date Version Valid until

Typical Applications: Excavators Haul Trucks Wheeled Loaders Drag Lines Large Dozers Drills

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Superior by Design The Kidde ADS TM FM-200 System

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

ODS & SGG Alternatives for the Fire Protection Industry 2018

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

HFC-227ea FIRE SUPPRESSION SYSTEM

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

A Guide for Meeting NFPA 10 Subsection

Fire Protection in the Mining Industry. Garry Kwok Board Member

Creating a safer world!

tyco Fire & Safety RESEARCH VESSEL - NEW ORLEANS

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Fire and Extinguishing Tests on Computer Equipment

An Overview of Extinguishing Systems for Computer Equipment

GX-20/FM-200 Fire Extinguishing System

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Mitigating Fire Risks in Mission Critical Facilities

3M Novec Fire Protection Fluid

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

Oxeo extinguishing systems

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

CONSTANT MONITORING OF GASEOUS SYSTEMS

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

SECURITY BLANKET Foam Fire Protection Products

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

What extinguishes fires without pressure peaks?

Welcome to Argonite fire protection from Ginge-Kerr

What is HI-FOG? The natural enemy of fire

Carbon Dioxide Fire Suppression Systems

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Rick Seidel Fike Corporation Regional Sales Manager

automatic FiReFighTing SYSTeMS in PainT booths

Element C3.4 Fire Fighting Equipment

Protection on the move Vehicle Automatic Fire Suppression System (AFSS)

How can you minimize consequential damages in case of a fire?

Twin-Agent Fire Fighting/Securing Systems Specifications

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

MISSION CRITICAL FIRE PROTECTION

THE WORLD LEADER. in special hazard fire suppression solutions

Sinorix Silent Extinguishing Technology protecting the quiet way

fire detection CCTV access control alarms network cabling Camdetech Technologies (Pty) Ltd. Reg. No: 2000 / / 07 COMPANY PROFILE

& Fire Extinguisher Training

Water Mist Fire Suppression

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Engineering Specifications

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

CLEAN AGENTS & CLASS C FIRE HAZARDS

WATER MIST CONVENTION AND EXHIBITION

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

STAT X - SPECIAL HAZARD FIRE PROTECTION

Fire Prevention Systems

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

A safe journey with Dräger CRUISE CATALOGUE

HART XL High Sensitivity Smoke Detection

High flying fire protection HI-FOG for aircraft hangars

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

that sense s of ecurity

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Responsible Care Product Stewardship for Refrigerants

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

COMPANY OVERVIEW IN PURSUIT OF OUR COMPANY GOALS WE ARE COMMITTED TO: - Continual improvement. - Trained and dedicated personnel

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

Making equipment decisions

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Data/ Specification Sheet

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Transcription:

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

D E T E C T - S U P P R E S S - P R O T E C T T H E I N E R G E N C L E A N A G E N T S Y S T E M F R O M A N S U L

INERGEN IS BETTER FOR YOUR PROPERTY Upon discharge, INERGEN instantly floods the room, remaining suspended to suppress fires quickly and effectively. An inert gas mixture, INERGEN is absolutely free of residues and corrosive by-products that may produce further property damage. In performance testing, INERGEN easily exceeded the NFPA Standard 2001 allowance of one-minute discharge, with documented extinguishments of 22 seconds for a Class A fire and 17 seconds for a Class B fire. Reliable and field proven, INERGEN delivers the performance you would expect from the world leader in fire suppression. BETTER FOR YOUR PEOPLE One of the most remarkable aspects of INERGEN is that it is safe for people. Unlike halocarbon (chemical) alternatives, which can create dangerous levels of hydrogen fluoride when in the presence of fire, INERGEN is entirely nontoxic, producing no corrosive decomposition products whatsoever. Plus, because INERGEN will not produce a fog when discharged, escape routes remain visible. With INERGEN, the oxygen level is reduced enough to put out the flames, yet more than enough remains to breathe. In fact, those who breathe normally around INERGEN in extinguishing concentrations receive the same amount of oxygen to the brain as they would in an ordinary atmosphere, vital in cases where immediate evacuation may not be possible. BETTER FOR THE ENVIRONMENT The production of Halon 1301 was banned in 1993, a direct result of its negative effects on the ozone layer. We engineered INERGEN to be environmentally kind from the very start. INERGEN is nonsynthetic, made exclusively of gases we already breathe: nitrogen, argon, and carbon dioxide. Once discharged, it simply returns to the atmosphere in its natural state. And because it poses no ozone depletion or global warming potential, INERGEN will never be subject to future legislative bans.

STATE-OF-THE-ART DETECTION AND CONTROL INERGEN systems combine exclusive AUTOPULSE microprocessor units with highly sensitive smoke, heat and flame detectors, and specialized agent distribution components, designed to detect and suppress a fire even before it reaches the flame stage. The AUTOPULSE units also perform other key functions in case of fire, including sounding alarms, closing doors, and shutting down equipment. In conjunction with manual pull stations, the system provides automatic detection, day and night. FLEXIBILITY IS ALREADY BUILT IN INERGEN agent is stored as a gaseous mixture in DOT-approved steel cylinders filled to nominal capacities of 200 to 435 cu. ft. (5.7 to 12.3 cu. m). Available in four sizes, you can choose to install your cylinders either vertically or horizontally, allowing for a design that requires the fewest number of cylinders and the lowest cost. You then have a choice of setting up your cylinders to open electrically, pneumatically or manually, depending on your need. MAKE ANSUL YOUR FIRE PROTECTION PARTNER THROUGHOUT YOUR BUSINESS From INERGEN automatic detection and suppression systems to a full range of wheeled and portable extinguishers and more, no other fire suppression brand promises the full range of solutions or the quality of ANSUL. And we back all of our products with a worldwide network of factory-trained distributors the largest and best qualified in the industry. APPLICATIONS THAT BENEFIT FROM INERGEN SUPPRESSION SYSTEMS: n AUTOMATED TAPE STORAGE LIBRARIES n COMPUTER AND DATA PROCESSING FACILITIES n CULTURAL AND HISTORICAL SITES n HOSPITAL AND MAJOR MEDICAL FACILITIES n MARINE/OFFSHORE/ NAVAL n MUSEUMS AND ART GALLERIES n POWER GENERATION FACILITIES n TELECOMMUNICATION FACILITIES

EVEN AFTER THE FIRE, YOU RE UP AND RUNNING In minutes, fire and the attempts to put it out can destroy the equipment that keeps your operation in action. And yet, without the right defenses in place those that protect people, property and the environment many businesses are putting themselves at needless risk every day. Others, however, have an INERGEN system at the ready. Created as an ozone-safe replacement for Halon 1301, INERGEN is the nucleus of ANSUL s contemporary approach to fire protection: protect lives, protect property and protect the environment. Clean, non-conductive INERGEN is a natural fire suppression agent particularly suited to areas where damage from conventional agents cannot be tolerated, such as sensitive data storage, information processing and systems operation electronics. In addition, many archival organizations use INERGEN to protect valuable, irreplaceable items such as artwork, historic documents and antiquities. NO OZONE DEPLETION, GLOBAL WARMING POTENTIAL OR ATMOSPHERIC LIFETIME ENTIRELY INERT n SAFE FOR SENSITIVE ELECTRONICS AND IRREPLACEABLE ITEMS ALL- NATURAL n UL/ULC, FM, USCG AND MANY INTERNATIONAL APPROVALS/LISTINGS EVERGREEN DISCHARGE WARRANTY n ENVIRONMENTAL WARRANTY

Head Office Jl. Gunung Sahari Raya No.57 G Jakarta 10610, Indonesia Telp : +62-21 420 9908 Fax : +62-21 424 4318 Email : info@indobara.co.id Sales Office Jl. Gunung Sahari Raya No.51.2 Jakarta 10610, Indonesia Telp : +62-21 420 9033 Fax : +62-21 425 3065 / 420 3454 Email : info@indobara.co.id Branch Office Surabaya Kompleks Mangga Dua Blok AA216/17 Jl. Jagir Wonokromo 100 Surabaya 60244, Indonesia Telp. : +62-31 848 3383 Fax. : +62-31 848 3373 Email : info.sby@indobara.co.id Branch Office Kalimantan Jl. Jend. Sudirman No.379, RT 23, Kelurahan Damai Balikpapan 76114, Kalimantan Timur, Indonesia Telp. : +62-542 731 205 Fax. : +62-542 732 125 Email : info.bpp@indobara.co.id Workshop Jl. Perdatam Raya No.3 Jakarta Selatan 12780, Indonesia Telp. : +62-21 794 7466-9 Fax. : +62-21 794 7470 Email : info.wrk@indobara.co.id Ansul Incorporated One Stanton Street Marinette, WI 54143-2542 800-862-6785 (United States, Canada) 715-735-7411 (International) www.ansul.com Copyright 2008 Ansul Incorporated n ANSUL, INERGEN and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. Form No. F-2006100