TRUSTED PERFORMANCE. Carbon Dioxide Fire Suppression Systems

Similar documents
Carbon Dioxide Fire Suppression Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Hospitals and Major Medical Centers

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

FIRE SUPPRESSION SYSTEM

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Twin-Agent Fire Fighting/Securing Systems Specifications

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

Inert Gas Fire Extinguishing System

Typical Applications: Excavators Haul Trucks Wheeled Loaders Drag Lines Large Dozers Drills

A Guide for Meeting NFPA 10 Subsection

Protection on the move Vehicle Automatic Fire Suppression System (AFSS)

Specification/ Data Sheet

SECURITY BLANKET Foam Fire Protection Products

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

Data/ Specification Sheet

Engineering Specifications

CORE Protection Fire System Specification

CO2 COCO GAS FLOODING SYSTEM

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Superior by Design The Kidde ADS TM FM-200 System

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

CARBON DIOXIDE CO 2 Industrial fire suppression systems

CleanSpray System Operation

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Fixed Fire Extinguishing Equipment and Systems

Safe, Effective, Environment-friendly

Certificate of Conformity Certificate num. Registration date Version Valid until

CHECKFIRE 210 Detection and Actuation System

Connected: Global protection, all together

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

R-102 RESTAURANT FIRE SUPPRESSION SYSTEM

Badger Universal Control Head

CO 2. fire extinguishing systems

SAFETY THE BEST FOR YOUR EQUIPMENT

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Agent Tanks PCL PCL PCL PCL - 600

CO 2 EXTINGUISHING SYSTEMS

An efficient solution for more comfortable environments

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

How can I protect invaluable assets and the environment from the effects of a fire?

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

Types of Detection. Fusible Link Detection - Most Common

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

An Overview of Extinguishing Systems for Computer Equipment

Fire Suppression Solutions

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

THE WORLD LEADER. in special hazard fire suppression solutions

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

NEOTeCHA Reactor Sampling Type PV

Deluge & Preac tion Systems

SPECIFICATION: ARGONITE Engineered Fire Suppression System

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

HFC-227ea FIRE SUPPRESSION SYSTEM

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

minibrs Toll Free: Compact, powerful system is comfortable, easy to use and requires no containment

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

¼ Dosing and Transfer Pump. Same Great Name. Revolutionary New Design.

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Performance You Demand. Reliability You Trust. QUINCY QSI POWER$YNC SERIES ROTARY SCREW VARIABLE DISPLACEMENT COMPRESSORS HP

COMPANY PROFILE

The leader in gas dehydration & filtration

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

Basic Vehicle Fire Protection Manual

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

TotalPac 3 Firecyle III Deluge Remote controlled system

STAT X - SPECIAL HAZARD FIRE PROTECTION

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation.

Reliance Fire Protection Systems

User manual Flushing device VAS 6337/1a

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Transcription:

TRUSTEDPERFORMANCE Carbon Dioxide Fire Suppression Systems

GETBACKINBUSINESS QUICKLYAFTERAFIRE A fire in your facility is never pleasant. But, it doesn t have to be debilitating. Carbon dioxide, the original clean agent, is still an economical solution, providing automatic or manual protection for Class A, B or C fires. TRIEDANDTRUE The only gaseous agent capable of deep seated Class A hazard protection, versatile CO 2 can flood enclosed areas or discharge directly onto burning surfaces. Intelligent control panels and detectors, such as an AUTOPULSE Control System, offer alarm, auxiliary control and automatic release. To help ensure safety, all personnel must be trained on the CO 2 system and warned not to enter the hazard area during discharge, or until the area is cleared. Your fire protection partner, ANSUL continues to lead the fire suppression industry with a full range of quality solutions and specialized products backed by a worldwide network of the most qualified distributors in the industry. APPROVALS/LISTINGSINCLUDEUL,FMANDUSCG _LESSPOST FIREDOWNTIME HIGHANDLOWPRESSURESYSTEMOPTIONS_WIDESTSELECTIONOFNOZZLESINTHEINDUSTRY 120LB.CYLINDERREDUCESSTORAGEREQUIREMENTS

HIGHPRESSURECO2SYSTEMS ANSUL High Pressure Carbon Dioxide Systems are especially effective for non-occupied hazards such as semiconductor wet benches, control rooms and paint lines. Whatever the application, from cylinder to nozzle, each system is custom-designed for your specific fire hazards. High pressure systems use individual storage cylinders from 35 lb. (16 kg) to 120 lb. (54 kg) capacity each that can be manifolded together for rapid simultaneous discharge. Cylinder valves can be opened automatically or manually, and either locally or remotely using electric, pneumatic or mechanical valve actuators. Odorizer emits wintergreen scent during discharge Lock-out valve Discharge pressure switch Manifolding allows single or multiple hazard protection from one storage location (selector valves available for multiple hazards) Resettable/stackable electric valve actuator with manual lever release Cylinder valves operate automatically via manifold backpressure Modular mounting bracket design The industry s widest selection of total flood and local application nozzles CO 2 cylinders: 35, 50, 75, 100 and 120 lb. (16, 23, 34, 45 and 54 kg) capacities USCG applications allow only manual or pneumatic actuation systems. Must also haveatimedelayandsiren. Detectionandcontrolsystemavailable (notshown).automatessystemand providesmoreflexibilitytomeetdesign requirementsnecessaryforthehazard.

BULKLOWPRESSURECO2SYSTEMS ANSUL PREFERRED Bulk Low Pressure Carbon Dioxide Systems are ideal for non-occupied fire hazards requiring large amounts of extinguishing agent in a limited space. A single bulk tank can store from 3/4 to 60 tons (680 to 54430 kg) of carbon dioxide, which is maintained in a stand-by fire-ready state. This allows the system to provide effective distribution of agent on demand. Bulk low pressure CO 2 systems offer multiple discharge capabilities between recharges as an economical option. The liquid CO 2 is stored in an ASME-coded pressure vessel equipped with its own refrigeration system. The temperature within the vessel is kept at approximately 0 0 F (-17 0 C) by maintaining the internal pressure near 300 psi (20.7 bar). Valve control is electro-pneumatic or manual. Each master and selector valve assembly consists of either a ball or butterfly valve, a spring return pneumatic valve operator and a three-way electronically operated solenoid valve. A listed and approved releasing control panel is used to provide automatic detection and control. Available nozzles include SR, Orifice, D and Radial (SR is shown) Odorizer emits wintergreen scent during discharge Lock-out valve Discharge pressure switch Manual/automatic selector valve for multiple hazard protection Hose reel station available with 100 or 150 feet (30 or 46 m) of hose Manifold coil refrigeration unit is energy-efficient Bulk storage tank: 3/4 to 60-ton (680 to 54430 kg) capacity Detectionandcontrolsystemavailable (notshown).automatessystemand providesmoreflexibilitytomeetdesign requirementsnecessaryforthehazard.

MINI BULKLOWPRESSURE CO2SYSTEMS Bridging the gap between high pressure cylinders and low pressure bulk tanks, mini-bulk tanks offer capacities of 1,000 and 1,500 lb. (454 and 680 kg). The ANSUL PREFERRED Mini-Bulk Low Pressure Carbon Dioxide Systems were developed to provide an alternative to manifolding high pressure cylinders. The tanks are configured vertically to save valuable floor space: mini-bulk tanks can provide protection for non-occupied total flood, local application hazards, hose reels or custom designs such as inerting or spurt systems. Available nozzles include SR, Orifice, D and Radial (SR shown) Discharge pressure switch Odorizer emits wintergreen scent during discharge Lock-out valve Manual/automatic selector valve for multiple hazard protection Low-cost, high-efficiency cooling system operates at 120 VAC When system is actuated, Automatic Timer Cabinet delays discharge, alerts personnel of pending emission and manages valve operation Exclusive mini-bulk tank design: 1,000 and 1,500 lb. (454 and 680 kg) capacities Detectionandcontrolsystemavailable (notshown).automatessystemand providesmoreflexibilitytomeetdesign requirementsnecessaryforthehazard.

Each mini-bulk tank is equipped with a low-cost, high-efficiency, air-cooled refrigeration unit. The refrigerant media, R134a, is environment-friendly and is very efficient in this application. Most system components are interchangeable between the mini-bulk system and the larger bulk storage tank system. The system control valves operate on 24 VDC, which is compatible with most approved releasing panels. Mini-bulk tanks can be filled in place or can be removed for remote filling. When filling in place from a standard delivery truck, fill connectors can be extended to an area outside the building. The storage tanks are provided with skid-mounted bases for easy handling with a forklift. CHOOSE TO PARTNER WITH THE EXPERIENCE AND EXPERTISEOFANSUL Make ANSUL the exclusive fire protection brand throughout your business. From carbon dioxide fire suppression systems to extinguishers and agents, no one else promises the full range of solutions and quality of ANSUL. Plus, all products are backed by a network of factory-trained distributors the largest in the industry. Choose to protect people and assets with the name you know. Choose ANSUL. ANSULCARBON DIOXIDEFIRE SUPPRESSION SYSTEMS HAVE BEENPROVEN EFFECTIVEIN NUMEROUS NON OCCUPIED APPLICATIONS: _COMMERCIALAND INDUSTRIALFRYERS _DIPTANKS _ELECTRIC GENERATORS _ELECTRIC GENERATINGEQUIPMENT _ELECTRICALPANELS _MARINEAPPLICATIONS (CARGOHOLDS,PAINT LOCKERS,ENGINEROOMS,SCR ROOMS,SNUFFINGSYSTEMS, ETC.) _SPRAYBOOTHS _WASTEDISPOSAL EQUIPMENT _GASTURBINES _COALSILOS _HAZARDOUSMATERIAL STORAGE _QUENCHTANKS _SEMICONDUCTOR WETBENCHES _COMPUTERROOM SUBFLOORS _NON OCCUPIED CONTROLROOMS _COATINGOPERATIONS _PAINTLINES _WAVESOLDER MACHINES _MACHININGOPERATIONS _HOSEREELSTATIONS _TRANSFORMER VAULTS _DUSTCOLLECTORS _PRINTINGPRESSES _INERTINGSYSTEMS

Head Office Jl. Gunung Sahari Raya No.57 G Jakarta 10610, Indonesia Telp : +62-21 420 9908 Fax : +62-21 424 4318 Email : info@indobara.co.id Sales Office Jl. Gunung Sahari Raya No.51.2 Jakarta 10610, Indonesia Telp : +62-21 420 9033 Fax : +62-21 425 3065 / 420 3454 Email : info@indobara.co.id Branch Office Surabaya Kompleks Mangga Dua Blok AA216/17 Jl. Jagir Wonokromo 100 Surabaya 60244, Indonesia Telp. : +62-31 848 3383 Fax. : +62-31 848 3373 Email : info.sby@indobara.co.id Branch Office Kalimantan Jl. Jend. Sudirman No.379, RT 23, Kelurahan Damai Balikpapan 76114, Kalimantan Timur, Indonesia Telp. : +62-542 731 205 Fax. : +62-542 732 125 Email : info.bpp@indobara.co.id Workshop Jl. Perdatam Raya No.3 Jakarta Selatan 12780, Indonesia Telp. : +62-21 794 7466-9 Fax. : +62-21 794 7470 Email : info.wrk@indobara.co.id Ansul Incorporated One Stanton Street Marinette, WI 54143-2542 800-862-6785 (United States, Canada) 715-735-7411 (International) www.ansul.com Copyright 2007 Ansul Incorporated 9 ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates. Form No. F-2007054