SD-06AG Laboratory Scale Spray Dryer

Similar documents
ASSEMBLY & OPERATING INSTRUCTIONS

Powder Technology Division. Niro. Fluidized Spray Dryer FSD

Laboratory Scale Spray Dryer SD-15 Operation Manual

Mini Spray Dryer B-290 Technical data sheet

QAQC LABS ANALYTICAL DRYING

Model KBF 240 Constant climate chambers with large temperature / humidity range

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Industrial peristaltic pumps

The AST Dryer

Industrial peristaltic pumps

UVC/T-AR UVC/T-M-AR UVT-S-AR

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

GRINDING & POLISHING VELOX 402. metkon.com

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T

SPRAY DRYING SYSTEMS INC.

Chemistry diaphragm pumps

Freeze Dry Systems and Accessories

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

PLC Control Touch-Screen

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Fume Extraction Solutions. We care for your working environment.

Innovative cleaning with dry ice: No residue, no chemicals.

Plant growth chambers

DRYING OF MILK SPRAY DRYING

ingersoll rand refrigerated air dryers

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

Mini Spray Dryer B-290 Technical data sheet

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

IB 15/80 Ice Blaster. Innovative cleaning with dry ice: No residue, no chemicals.

Ingersoll Rand. Refrigerated Air Dryers

The Hydrim M2 washer disinfector. Perfectly prepares large volumes of instruments for sterilisation.

Refrigerators & ULT Freezers

From Drops to Powder From a Suspension to a Granulate. Innovative Processing of Fluids in Fluidised Bed Dryers

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

HICOSYS FOR PROCESS CONTROL OF SPRAY DRYERS

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

Ozone & UV & AOP Solutions ADVANCED TECHNOLOGIES

COMPRESSED AIR TREATMENT

Freeze Dry Systems and Accessories

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Freeze Dry Systems and Accessories

Phone: Fax :

Horizontal Disk Mill. Type LME / LMK. The successful disk grinding system sets new standards regarding efficiency and flexibility.

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Large Steam Sterilizers. CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

Section N. Application Information. Thermal Manufacturing Solutions. Extrusion N-1. Injection Moulding N-2 N-3. Other N-4

Oil Mist Separator Unit LGA 600 FUW

ROTARY DRYER CONSTRUCTION

All rights for changes reserved that lead to technical improvement. kolb GmbH 2017

SalvisLab Cleaners Quiet and Efficient - Typical Swiss Precision

UVC/T-M-AR stainless steel UV cabinet

AZTECA A LITRE STERILISER

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

SIZE REDUCTION TECHNOLOGY

ULTIMATE ENERGY SAVING TECHNOLOGY

Advantages / Characteristics

With the world-renowned SIGMA PROFILE

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Laboratory Twin-Screw Kneader Modular design easy to use versatile in application

PROCELL LABSYSTEM. direct pelletization. Glatt. Integrated Process Solutions.

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

DRYMAX Dryers. Dry Air Dryers for Plastic Resin. Technology working for you.

Washer Extractors TWE 10-15

Conveyorised tunnel washers

Installation, Operation & Maintenance Instructions Annealing Ovens TLD models

SMALL SCALE PLANTS. Anhydro Small Scale Plants FOR THE DAIRY, FOOD, CHEMICAL AND PHARMACEUTICAL INDUSTRIES

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

DDM SERIES. Desiccant Dryer Mobile Drying of free-flowing granular plastic materials

Floor model Freeze Dryer

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

ROTATORY EVAPORATOR AND PUMPS

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Drying Cabinet Installation and Operating Manual

OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Introduction to Pharmaceutical Freeze Drying

Fred Castle Way Rougham Industrial Estate Bury St Edmunds Suffolk IP30 9ND United Kingdom

Constant climate chambers

Ingersoll Rand. Refrigerated Air Dryers. mb air systems ltd

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

Oil Mist Separator Unit LGA 600 FUW

Oil-Less Rotary Screw Compressors

SUPREMATouch. Modular Fire & Gas Detection System

LABOKLAV. Autoclaves Made in Germany

Downstream Processing Prof. Mukesh Doble Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 36 Drying

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

DEKO 260 Washer - Disinfector - Dryer

clean and quiet laboratory

Adsorption Air Dryers

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

1 L Rotary Vacuum Evaporator Instruction Manual

Order by phone Order on-line Order by fax Website

Transcription:

SD-06AG Laboratory Scale Spray Dryer

SD-06AG Laboratory Scale Spray Dryer INTRODUCTION The LabPlant SD-06AG Laboratory Scale Spray Dryer is the result of 30 years of continuous development in the field of laboratory scale spray drying systems. The unit is self contained and supplied complete and ready for immediate operation. All major components are housed within a stainless steel cabinet and the unit can be used on a bench top or with an optional stainless steel stand. The SD-06AG only requires connection to a 13 amp, 220/240 V, 50 Hz power supply (Other Power Requirements Available) and provision for exhausting the evaporated moisture to atmosphere or to an existing extraction system. TECHNIQUE A menu driven microprocessor controller allows the selection of inlet temperature, airflow, automatic de-blocker frequency and pump speed. The controller features an RS 232 output for connection to a PC or datalogger and software allows the control and monitoring of all functions and printing of results. The self-priming peristaltic pump delivers the sample liquid from a container through a small diameter jet into the main chamber. At the same time an integral compressor pumps air into the outer tube of the jet which causes the liquid to emerge as a fine atomised spray into the drying chamber. Heated air is blown through the main chamber evaporating the liquid content of the atomised spray. The solid particles of the material, which are normally in a free flowing state, are then separated from the exhaust air flow by a cyclone and collected in the sample collection bottle. The exhaust airflow is directed through a flexible 50 mm diameter hose direct to atmosphere or to an existing extraction system. APPLICATIONS Spray drying can be used in a wide range of applications where the production of a free-flowing powder sample is required. This technique has successfully processed materials in the following areas: SD-06AG Main unit on stand. ADVANTAGES Almost all other methods of drying e.g. the use of Ovens, Freeze Dryers or Rotary Evaporators produce a soft mass of material often described as a cake. This cake then requires further processing (grinding, filtering etc.) and the resulting material is often of very irregular particle size and shape. The Spray Drying process usually produces a free flowing powder sample of a spherical nature and can produce very fast results from a small liquid sample. Beverages Flavours and Colourings Milk and Egg Products Plant and Vegetable Extracts Pharmaceuticals Heat Sensitive Materials Plastics Polymers and Resins Perfumes Ceramics and Advanced Materials Soaps and Detergents Blood Dyestuffs Foodstuffs Adhesives Oxides Textiles Bones, Teeth and Tooth Amalgam and many others. Most solutions and suspensions can be spray dried providing that the resulting product has the characteristics of a solid material. The Spray drying process usually produces a free flowing powder sample.

CONTROLS AND FUNCTIONALITY The unit is designed to ensure that all functions are simple to select and adjust, to quickly achieve the optimum conditions for Spray Drying. Using a clear LCD display, which is protected to IP65, the operator can control the following functions : Inlet temperature Airflow volume Pump speed De-blocker frequency SD-06AG Control panel screens. Start screen. CONSTRUCTION A robust chemically resistant 316 grade stainless steel cabinet houses all mechanical and electrical components necessary to perform the spray drying process. All clamps and fittings are designed to allow assembly and removal of the glass components in only a matter of seconds. The rear of the cabinet includes an inlet filter designed to remove 99.99% of air laden particles ensuring that the drying air does not include contaminants. A specially designed stainless steel support stand is available where bench space or height restrictions are a consideration. TWO FLUID NOZZLE The stainless steel spray assembly consists of an inner tube for the liquid sample leading to a small diameter jet. An outer tube directs the supply of compressed air to the nozzle and the close tolerance gap between the nozzle and the jet ensures a fine vaporised spray. The SD-06AG is supplied as standard with 0.5 mm jet and other sizes are available as accessories. The spray assembly incorporates an automatic de-blocking device that prevents the jet nozzle from becoming blocked. The de-blocking needle is activated by an integral compressor. De-blocking is sometimes necessary with materials which may solidify or when large particles in suspension cause blockages in the jet. Temperature selection. TECHNICAL INFORMATION Pump speed selection. Unit operational. End of process. Evaporation rate of water at inlet temperature of 250ºC using Standard Chamber Air inlet temperature range Drying air throughput /HR Heater capacity Compressor Sample feed Jet de-blocking Spray system Spray/hot air flow Power supply Dimensions Unit Weight *without jet assembly Approximately 1500 ml/hour 40ºC to 250ºC Variable from 39 to 70 m# 3 kw 2.0 m#/hr @ 2.0 bar / 1.7 m# @ 4 bar Peristaltic pump with flow rate variable up to 32 ml/min (2.0 l/hr) Integral 2.3 bar compressed air supply with variable de-blocking plunger frequency 2 fluid nozzle with standard 0.5 mm jet and options of larger diameters Downward co-current 220/240 V - 50/60 Hz - 13 amps (Other Power Requirements Available) 1110* x 825 x 600 mm (H x W x D) 80 KG We reserve the right to change information given without prior notice.

SD-06AG Glassware. SD-06AG Components. ORDERING INFORMATION SD-06AG Spray Dryer SD-06AG complete 220/240 V - 50/60 Hz (Other Power Requirements Available) Complete with all parts necessary for spray drying including blower, heater, heater control, exhaust temperature indicator, spray system with 0.5 mm jet, spray atomiser compressor, auto jet de-blocking system with compressor, 215 mm OD x 500 mm long main chamber, cyclone and all glassware. LabPlant UK Limited Design & production by

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.