READ AND SAVE THESE INSTRUCTIONS

Similar documents
READ AND SAVE THESE INSTRUCTIONS

PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06

PORTACOOL CYCLONE OWNER S MANUAL

PORTACOOL CYCLONE OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Owners Manual For All Electric Models

PORTACOOL OWNER S MANUAL. FOR PAC2K482S, PAC2K363S, PAC2K361S, PAC2K36HPVS, PAC2K24HPVS and PAC163SVT

PORTABLE EVAPORATIVE COOLING UNIT OWNER S MANUAL

PORTACOOL HAZARDOUS LOCATION OWNER S MANUAL PACHZ260AZ, PACHZ270AZ, PACHZ260CZ, PACHZ270CZ

MANUAL CYCLONE OWNER S PORTACOOL PAC2KCYC01, PACCYC02, PACCY110, PACCY120, PACCY130, PACCY160

CLASSIC MANUAL OWNER S PORTACOOL PAC163SVT, PAC161SVT, PAC2K36HPVS, PAC2K361S, PAC2K482S, PAC2K481S

PORTACOOL ISLANDER OWNER S MANUAL

PORTACOOL CYCLONE OWNER S MANUAL PACCY110, PACCY120, PACCY130, PACCY140, PACCY160. * Applies to all 120 and 240V products for global configurations

If you have any problems with this product, please call BEFORE returning it to your retailer.

Manual for MC91 SETUP INSTRUCTIONS

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Manual for MC21A SETUP INSTRUCTIONS

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

PORTACOOL HURRICANE OWNER S MANUAL PACHR370, PACHR360

Manual for MC37/MFC3600

With Remote Control. English

48 MaxxAir Portable Evaporative Cooler Owner s Manual

Manual update 2016 MC37/MFC3600

Owner s. Coolerr. comply. To view

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Owner s. 18 Misting MF18W. To view

OWNER S MANUAL & WARRANTY

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

O w n e r s M a n u a l

model VH200 vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

USE AND CARE MANUAL HIGH CAPACITY FAN EVAPORATIVE COOLERS CFD4200 CFD4800 SERIES NOTE! NOTE:

1 HP Air Mover. Owner s Manual

model PIVOT HEAT vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

EVAPORATIVE AIR COOLER SERVICE MANUAL

PERSONAL HEATER OWNER S GUIDE

EVAPORATIVE COOLER W

Operation and Maintenance Manual 120V/60HZ

model ATH1 TOWER HEATER OWNER S GUIDE vornado.com READ AND SAVE THESE INSTRUCTIONS

model VMH300 vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Stand Fan. English. Owner s Guide. Model F R

With Remote Control. English. Model

Owner s Manual. For the Fuller Brush PORTABLE CANISTER Vacuum. Model FB-GIM

22In. Oscillating Pedestal Fan. Owner s Manual

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

model IR400 DUAL ZONE INFRARED HEATER OWNER S GUIDE vornado.com READ AND SAVE THESE INSTRUCTIONS

ELECTRIC STOVE HEATER Models: FS2213B

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

model TVH 500 vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

OWNERS MANUAL U.S. Patent 6,223,548 U.S. Patent D 362,905 U.S. Patent 6,502,414

model AVH10 & AVH30 WHOLE ROOM HEATER OWNER S GUIDE vornado.com READ AND SAVE THESE INSTRUCTIONS

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Thanks for shopping with Improvements! Evaporative Air Cooler with Adjustable Flow Valve Item #437979

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295

Xaact Spot. Xaact Hot Spot

ELECTRIC FIREPLACE OWNER S MANUAL

Dayton Electric Infrared Fireplace User Manual

PROFESSIONAL AIR MOVER OWNER S MANUAL

R Series B & T2 Model

HI Industrial Utility Heater HI Soleus Air International

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Operation and Maintenance Manual 120V/60HZ

BLT-999W-2 Item # 60757

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

6-Gallon Carpet Extractor Series

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

YOUR PORTABLE AIR PURIFIER

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

SILVER SWAN S MODEL SSS

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Model 1850F Dehumidifier Installation and Operating Manual

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

IW-25-2 Dehumidifier Installation & Operations. Manual

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Quest Power Electric Heat EHS 31 Pro

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Zeus Extreme Owner's Manual

User s Manual and Operating Instructions

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

High-Velocity Floor Fan

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

PORTABLE DEHUMIDIFIER

FLCH4R Garage and Utility Electric Heater

SSS Intrepid 16 FMS. Manual

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

BIOCIDE ANTIMICROBIAL DRY VACUUM

Instruction Manual Item No.: V~, 60Hz

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Description of the vacuum. (The chances are you re never going to read me) Owner s Manual. models X9 & G9.

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Transcription:

Owners Manual Port-A-Cool Products and Accessories and Küül Pads Cooling Media are manufactured by Port-A-Cool, LLC P.O. Box 2167 709 Southview Circle Center, TX 75935 Phone 936-598-5651 800-695-2942 www.port-a-cool.com For Models: PAC2KCYC01, PAC2KCYCO1A, PACCYC22050, PACCYC22060, PACCYC22050A and PACCYC22060A PAC-ACC-06 READ AND SAVE THESE INSTRUCTIONS

ITEM# PART # DESCRIPTION ITEM# PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 22 PAD-SCREEN-CYL CYCLONE UNIT PAD SCREEN 2 BLOWER-01 BLOWER HOUSING 23 POLY-FTG-06 90 DEG. FITTING FOR SIGHT TUBE 3 BLOWER-WHL-01 BLOWER WHEEL 24 POWERCORD-01 POWER CORD W / DOME STRAIN RELIEF 4 BONNET-05 BONNET 25 PRES-REG-01 INLET WATER REGULATOR 5 BOX-UL-02 2 SPD UL ELECTRICAL BOX 26 PUMP-BRACKET-04 ALUM. BAR PUMP BRACKET 6 CAPACITOR-02 20uF CAPACITOR 220/60 CYCLONE 27 PUMP-150-3 220/60 CYCLONE PUMP 7 CASTER-3-L 3 LOCKING CASTERS 28 PVC-ADP-01 8 CASTER-3-NL 3 CASTERS 29 RIVET-5/32-02 5/32 LARGE RIVET 9 CLAMP-01 1/2 WIRE SPRING CLAMP 30 S-004 FLOAT BOLT 10 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 31 S-006 TEC SCREW S006 11 CTRL-VLV-BRKT VALVE-01 MOUNTING BRACKETS 32 S-009 10/24 x 3/3 TRUSS HEAD SCREW 12 DRAIN-PLUG-01 DRAIN PLUG 33 S-014 5/16 x 1 TRUSS HEAD SCREW 13 FANGUARDCLIP-01 CLIP 34 S-017 5/16-18 x 1.5 TRUSS HEAD SCREW 14 FLAP-05 FLAP 35 SPRAY-CYC-01 16 SPRAY BAR 15 FLOAT-02 FLOAT VALVE 36 SPRAY-ACC-04 SPRAY BAR CLIP 16 HOSE-FM18 18 FLOAT HOSE 37 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 17 HOSE-FTG-05 SWIVEL HOSE FITTING 38 TROUGH-04 36 PAC TROUGH 18 MESH-PAC-07 CYCLONE MESH PAC 39 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 19 MOTOR-013-08 1/3 HP - 220/60 2SPD MOTOR 40 TUBE-01 PUMP TO SPRAY BAR TUBING 20 PAC-PLB-01 INLET HOSE ADAPTER 41 TUBE-03 SIGHT TUBE 21 PAD6022/26 KUUL PAD SET FOR CYCLONE

TABLE OF CONTENTS Introduction... 1 How to Safely Operate your new Cyclone unit... 1 Setting up your new Port-A-Cool Cyclone 3000... 2 How to Operate your new Port-A-Cool Cyclone 3000... 3 How to Maintain Your Port-A-Cool Cyclone 3000... 3 How to Maintain the Küül pads media... 5 Replacing Küül pad media... 5 Troubleshooting... 6 ITEM# PART # DESCRIPTION ITEM# PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 22 PAD-SCREEN-CYL CYCLONE UNIT PAD SCREEN 2 BLOWER-01 BLOWER HOUSING 23 POLY-FTG-06 90 DEG. FITTING FOR SIGHT TUBE 3 BLOWER-WHL-01 BLOWER WHEEL 24 POWERCORD-01 POWER CORD W / DOME STRAIN RELIEF 4 BONNET-05 BONNET 25 PRES-REG-01 INLET WATER REGULATOR 5 BOX-UL-02 2 SPD UL ELECTRICAL BOX 26 PUMP-BRACKET-04 ALUM. BAR PUMP BRACKET 6 CAPACITOR-02 20uF CAPACITOR FOR 220/50HZ CYCLONE 27 PUMP-150-3 220-50HZ PUMP FOR CYCLONE 7 CASTER-3-L 3 LOCKING CASTERS 28 PVC-ADP-01 8 CASTER-3-NL 3 CASTERS 29 RIVET-5/32-02 5/32 LARGE RIVET 9 CLAMP-01 1/2 WIRE SPRING CLAMP 30 S-004 FLOAT BOLT 10 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 31 S-006 TEC SCREW S006 11 CTRL-VLV-BRKT VALVE-01 MOUNTING BRACKETS 32 S-009 10/24 x 3/3 TRUSS HEAD SCREW 12 DRAIN-PLUG-01 DRAIN PLUG 33 S-014 5/16 x 1 TRUSS HEAD SCREW 13 FANGUARDCLIP-01 CLIP 34 S-017 5/16-18 x 1.5 TRUSS HEAD SCREW 14 FLAP-05 FLAP 35 SPRAY-CYC-01 16 SPRAY BAR 15 FLOAT-02 FLOAT VALVE 36 SPRAY-ACC-04 SPRAY BAR CLIP 16 HOSE-FM18 18 FLOAT HOSE 37 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 17 HOSE-FTG-05 SWIVEL HOSE FITTING 38 TROUGH-04 36 PAC TROUGH 18 MESH-PAC-07 CYCLONE MESH PAC 39 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 19 MOTOR-013-08 1/3 HP - 220/50HZ 2SPD MOTOR 40 TUBE-01 PUMP TO SPRAY BAR TUBING 20 PAC-PLB-01 INLET HOSE ADAPTER 41 TUBE-03 SIGHT TUBE 21 PAD6022/26 KUUL PAD SET FOR CYCLONE Port-A-Cool Cyclone 3000 Wiring Diagram... 7 Product Warranty... 8 How to Contact Technical Support... 9 Replacement Parts... 10 PAGE 11

INTRODUCTION Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle in action when you step out of a swimming pool or shower and feel immediately cooler as water evaporates from the surface of your skin. Your evaporative cooler works on the same principle. Hot outside air is pulled through water-saturated pads, where the air is cooled by evaporation and then discharged from the cooler. SAFE OPERATION IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of electric shock, fire or injury: Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area where it will not be tripped over. Read instructions and labels carefully. Always unplug the electric cord to your cooler before you work on the cooler. Plug into three-prong grounded GFCI protected electrical receptacle only. Do not operate if there is any damage to the plug or cord. Do not step on or roll over power cord with heavy or sharp objects. Do not operate unit unless all panels are securely in place. Remove the plug from the electrical receptacle by pulling on the plug and not the cord. Test the GFCI receptacle or breaker monthly to ensure it is functioning properly. Do not operate near open containers of flammable liquids or gases. Never wash your cooler cabinet with a garden hose; water may harm the motor and electrical system. If the unit is damaged or it malfunctions, do not continue to operate it. Refer to the warranty, troubleshooting or FAQ section, call Port-A-Cool, LLC, Technical Support at (888) COOL-AIR (1-888-266-5243), or email support@port-a-cool.com. ITEM# PART # DESCRIPTION ITEM# PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 22 PAD-SCREEN-CYL CYCLONE UNIT PAD SCREEN 2 BLOWER-01 BLOWER HOUSING 23 POLY-FTG-06 90 DEG. FITTING FOR SIGHT TUBE 3 BLOWER-WHL-01 BLOWER WHEEL 24 POWERCORD-02 10ft POWER CORD W / DOME STRAIN RELIEF 4 BONNET-05 BONNET 25 PRES-REG-01 INLET WATER REGULATOR 5 BOX-UL-02 2 SPD UL ELECTRICAL BOX 26 PUMP-BRACKET-04 ALUM. BAR PUMP BRACKET 6 CAPACITOR-01 PSU 25-30 CAPACITOR 27 PUMP-CYCLONE CYCLONE PUMP - PEM-020 7 CASTER-3-L 3" LOCKING CASTERS 28 PVC-ADP-01 8 CASTER-3-NL 3" CASTERS 29 RIVET-5/32-02 5/32 LARGE RIVET 9 CLAMP-01 1/2" WIRE SPRING CLAMP 30 S-004 FLOAT BOLT 10 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 31 S-006 TEC SCREW S006 11 CTRL-VLV-BRKT VALVE-01 MOUNTING BRACKETS 32 S-009 10/24 x 3/3 TRUSS HEAD SCREW 12 DRAIN-PLUG-01 DRAIN PLUG 33 S-014 5/16 x 1" TRUSS HEAD SCREW 13 FANGUARDCLIP-01 CLIP 34 S-017 5/16-18 x 1.5" TRUSS HEAD SCREW 14 FLAP-05 FLAP 35 SPRAY-CYC-01 16" SPRAY BAR 15 FLOAT-02 FLOAT VALVE 36 SPRAY-ACC-04 SPRAY BAR CLIP 16 HOSE-FM18 18" FLOAT HOSE 37 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 17 HOSE-FTG-05 SWIVEL HOSE FITTING 38 TROUGH-04 36"PAC TROUGH 18 MESH-PAC-07 CYCLONE MESH PAC 39 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 19 MOTOR-013-07 1/3 HP - 2SPD MOTOR 40 TUBE-01 PUMP TO SPRAY BAR TUBING 20 PAC-PLB-01 INLET HOSE ADAPTER 41 TUBE-03 SIGHT TUBE 21 PAD6022/26 KUUL PAD SET FOR CYCLONE PAGE 1 PAGE 10

HOW TO CONTACT TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Port-A-Cool Technical Support Hotline at 888-266-5243 (888-COOL- AID) for the distributor nearest you. You may also contact the Support Hot Line for consultation on parts replacement. Please have serial number and model number of unit available. REPLACEMENT PARTS A. Returned Merchandise Authorization (RMA) Procedures All Port-A-Cool units, parts, or materials being returned to Port-A-Cool, LLC, for warranty replacement or repair require an RMA (Return Merchandise Authorization) number. There are two methods for replacing warranty parts: 1.The distributor can purchase the part with an RMA number and will only be charged for the cost of the part, not for the shipping. When the defective part is returned freight paid, the distributor s account will be credited for the cost of the part. 2.The customer / distributor can call Tech Support to get an RMA number to send the defective part back to Port-A-Cool, LLC. Once the part is received by Port- A-Cool, LLC, a replacement part will be sent at no charge. Information needed to get an RMA number: 1. The UNIT serial number. 2. The UNIT model number (ex. PAC2KCYC01) 3. The part number or description of the part to be replaced. Only major component parts need an RMA number, i.e. fans, motors, pumps, and some plumbing parts. For replacement of small parts, the serial and model numbers are still required, but the parts do not need to be returned to Port-A-Cool, LLC. For warranty replacement parts call Port-A-Cool Technical Support at 1-888-266-5243. FAX: 936-598-1431. Shipping Address Mailing Address: Port-A-Cool, LLC Port-A-Cool, LLC 721 FM 2468 at Henrietta Road P.O. Box 2167 Center, Texas 75935 Center, Texas 75935 SETUP INSTRUCTIONS The Port-A-Cool Cyclone 3000 model is pre-assembled and ready to operate. Simply remove the packaging and then carefully roll the unit from the box. Connecting to water. Move the cooler to an area where it can be filled with water and drained. The cooler should be located on level ground. Figure 1 Connect to a water supply using a commercial grade garden hose (supplied by customer). Simply attach the hose to the adapter located on the left side of the unit (see figure 1). Verify water tight connections by visually examining the hose connection and the drain plug. CAUTION: Water inlet pressure should be limited to a maximum 50 PSI. Connecting to a power supply. When making electrical connections insure that local and national codes are adhered to. Use only with GFCI Protected Receptacles. Please refer to the Barcode Product Label on the side of the unit for specific electrical requirements. LOCATION OF COOLER Always make sure the unit is operated on a level surface. When using the cooler indoors, the best location is near a partially opened window or door where hot outdoor air can be drawn into the unit. The Port-A- Cool Cyclone 3000 is portable, but use caution when rolling the unit to avoid splashing and spilling of water. Cool air can best be directed through the space by using a partly opened window or door, ideally one that is situated on the opposite side of the space from the cooler. This allows the cooled air to be moved through the space and exhausted back outdoors which is critical to proper operation of the cooler. PAGE 9 PAGE 2

OPERATING INSTRUCTIONS Make sure the two locking casters have been locked to prevent the cooler from moving before turning on the fan. Turn on the water supply to the cooler. The hose connection to the float valve provides an automatic method of refilling the water supply as water is evaporated. For best results, turn the pump on a few minutes before turning on the blower fan. This allows the cooling pads to pre-wet for best efficiency. Whenever possible operate the blower fan at low speed for maximum cooling. When cooling is not required you can operate the unit as a fan only by turning on the blower fan and leaving the pump turned off. WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device. CYCLONE UNIT MAINTENANCE & STORAGE At the end of the week or at a scheduled time, the unit should be shut down and the sump tank should be drained. To drain, remove small drain plug in the rear of the unit. Replace securely when finished. Once the sump is drained and the power disconnected, the pads may be removed to allow inspection of the sump tank. Assuming that the Port-A-Cool Cyclone 3000 unit is in a dusty environment, dust will collect in the sump tank over time. This debris and any remaining water may be vacuumed out using a wet/dry shop vacuum and wiped clean with a cloth. Also, inspect and clean the Inlet Strainer located on the pump. Replace pads in correct airflow direction, referring to label on the pads. Storage. Storage of the Port-A-Cool Cyclone 3000 unit is very simple. 1) Drain all water from the sump tank and clean as above, ensuring that the pads and sump are completely dry. CYCLONE LIMITED WARRANTY 1-YEAR LIMITED WARRANTY Port-A-Cool, LLC, Center, Texas, extends this limited warranty to the original purchaser of a Port-A-Cool Cyclone Evaporative Cooler operated under normal conditions within the continental United States. I. One Year Coverage applies to all components and accessories furnished by Port-A-Cool, LLC. At our option, we will exchange or repair any part which fails due to non-conformance of material or workmanship during the first year from the date of initial purchase. II. What this warranty does not cover: a. This warranty does not cover any failure or damage resulting from unauthorized modification or service; or from the use of products or replacement parts other than those from Port-A-Cool, LLC; including, but not limited to, motors and pumps. b. This warranty does not cover any damage or malfunction unless caused by a non-conformance in material or workmanship. Damage or malfunction which is not covered by this warranty includes, but is not limited to, water damage to the motor, abuse, misuse, alteration, improper installation / maintenance / operation, and transportation damage. c. Mineral accumulations, dirt, and dust on the pad are not defects and are excluded from this warranty. Refer to the owners manual supplied with your cooler for maintenance instructions to help minimize these conditions. d. This warranty does not cover the cost of a service call at the site of installation to diagnose cause of trouble, the cost of labor to install the part, or mileage allowance to or from the site. Port-A-Cool, LLC does not pay freight or postage on any exchange. e. This warranty does not cover evaporative coolers installed and operated outside the continental United States. III. Do not use cooler cleaners, cooler treatments, or other additives in this evaporative cooler. The use of any of these products will void your warranty and may impair the life of your evaporative cooler. IV. To obtain service under this warranty, contact the dealer where you purchased your evaporative cooler. As a final step, if you cannot locate your dealer, contact Technical Support, Port-A-Cool, LLC, P.O. Box 2167, Center, Texas 75935. Include your name, address and ZIP code, the model number and serial number of your evaporative cooler, date of installation and a description of your problem, or call 1-888-COOLAID or visit www.port-a-cool.com. This warranty is the only warranty extended by Port-A-Cool, LLC, to suppliers and/or purchasers of this evaporative cooler. Port-A-Cool, LLC disclaims all other warranties, express or implied, that arise by the operation of the law, except that implied warranties of merchantability or fitness for a particular purpose are limited to the duration of the warranty period. Port-A-Cool, LLC shall not be liable for any incidental or consequential damage which may have resulted from any alleged breach or warranty. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the limitations or exclusions stated above may not apply to you. This warranty gives you specific legal rights and you may have other rights, which vary from state to state. Since Port-A-Cool, LLC, follows a policy of continuous product improvement; it reserves the right to change design and specification without prior notice or liability. PAGE 3 PAGE 8

CAUTION: DISCONNECT POWER BEFORE REMOVING COOLING PADS FROM THE PORT-A-COOL unit!! 2) Roll up the electrical power cord and secure it to ensure that it will not be rolled over, tripped over or caught in equipment. NOTICE: POWER CORD MAY BE REPLACED ONLY BY THE MANUFACTURER OR QUALIFIED AGENT!! 3) Cover the Port-A-Cool Cyclone 3000 unit completely to prevent dust build-up and store in a dry area. This also helps prevent damage to the pads. Optional dust covers are available from your distributor. CYCLONE UNIT OPERATION WARNING 1) not intended for use by children 2) not intended for use by persons with reduced physical, sensory or mental capabilities 3) not intended for use by persons with lack of experience and knowledge, unless they have been given instruction and are supervised during operation 4) children should be supervised to ensure that they do not play with the appliance Control Panel Water Adjustment Valve Electrical Plug Locking Casters PAGE 7 PAGE 4

KÜÜL PAD MAINTENANCE Periodic draining of the pump will help reduce the build-up of calcium deposits on the pad and pad frame. Periodic cleaning of the pads will also help increase the life of the pads and the cooling performance of the cooler. Do not attempt to clean the pads while they are installed in the pad frames or in the cooler. They must be completely removed from the cooler (see Küül Pad Replacement on this page) and then can be hosed off and lightly brushed to remove or reduce the calcium build-up. Pads must be replaced, though, if the calcium build-up starts to completely block air passages through the pad. KÜÜL PAD REPLACEMENT The cooling pads should be changed at least every two years. Check and clean them at the beginning of the season. The pads may need to be replaced more frequently depending on local conditions and the maintenance schedule followed. Replace cooling pads as follows: CAUTION - DISCONNECT POWER BEFORE PERFORMING THIS OPERATION!! The flap must be removed to allow access to the cooling pads. Start with the center pad, which should be tilted out from the top and lifted out of the drain trough. The two pads to either side of the center pad may then be removed in the same manner. Should you desire to remove the two outside pads, they must first be pulled sideways toward the center of the Port-A-Cool Cyclone 3000 unit until they clear the side retainer. They may then be removed in the same manner as the other pads. TROUBLESHOOTING The following troubleshooting guide is intended to address the most common symptoms which may occur. If you are unable to resolve the issue, please call Technical Support. Turn off all power to the cooler before attempting to troubleshoot any of the following symptoms. SYMPTOM POSSIBLE CAUSES REMEDY Unit fails to start or deliver air 1. No electrical power to unit 1. Check power A. Fuse blown A. Replace fuse* B. Circuit breaker tripped B. Reset breaker* C. GFCI tripped C. Reset GFCI* D. Cord(s) unplugged or damaged D. Plug in cord(s) or replace if damaged * If condition persists, call electrician 2. Motor overheated and/or frozen 2. Replace motor Unit starts 1. Insufficient air exhaust 1. Open windows or doors but air delivery inadequate 2. Insufficient water pad not wet 2. Check water distribution system A. Cooling pads plugged A. Clean or replace pads B. Dry streaks on pads B. Check water level C. Large dry spots on pads C. Make sure cooler is level, clean spray bar D. Pump not working D. Clean or replace pump E. Loose water connections E. Check for leaks and correct Water draining from 1. Float arm improperly adjusted 1. Adjust float to proper level cooler 2. Seat in float valve leaking 2. Replace float valve 3. Drain bushing/cap not tight 3. Tighten fitting and/or cap Musty or unpleasant odor 1. Stale or stagnant water in sump 1. Drain, flush and clean sump 2. Pads mildewed or clogged 2. Replace pads 3. Pads not completely wet before 3. Turn on pump before starting fan cooler is turned on Knocking, shaking or 1. Loose parts 1. Check and tighten where needed rattling sounds 2. Blower wheel loose or rubbing 2. Inspect and adjust, or replace Water droplets in the 1. Too much water delivered to the 1. Make sure pads are properly positioned discharge air stream cooling pads in the pad frames and that the unit is level. 2. Outdoor humidity level is too high 2. Use cooler as a fan only (turn pump off) or it is raining or discontinue use of cooler until outdoor humidity level drops. PAGE 5 PAGE 6