PORTACOOL CYCLONE OWNER S MANUAL

Similar documents
PORTACOOL CYCLONE OWNER S MANUAL

PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01, PACCYC02, PACCYC03, PACCYC04, PACCYC06

READ AND SAVE THESE INSTRUCTIONS

PORTACOOL HAZARDOUS LOCATION OWNER S MANUAL PACHZ260AZ, PACHZ270AZ, PACHZ260CZ, PACHZ270CZ

MANUAL CYCLONE OWNER S PORTACOOL PAC2KCYC01, PACCYC02, PACCY110, PACCY120, PACCY130, PACCY160

CLASSIC MANUAL OWNER S PORTACOOL PAC163SVT, PAC161SVT, PAC2K36HPVS, PAC2K361S, PAC2K482S, PAC2K481S

PORTACOOL CYCLONE OWNER S MANUAL PACCY110, PACCY120, PACCY130, PACCY140, PACCY160. * Applies to all 120 and 240V products for global configurations

PORTACOOL ISLANDER OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

PORTACOOL HURRICANE OWNER S MANUAL PACHR370, PACHR360

PORTACOOL OWNER S MANUAL. FOR PAC2K482S, PAC2K363S, PAC2K361S, PAC2K36HPVS, PAC2K24HPVS and PAC163SVT

PORTABLE EVAPORATIVE COOLING UNIT OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Owners Manual For All Electric Models

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

If you have any problems with this product, please call BEFORE returning it to your retailer.

EVAPORATIVE AIR COOLER SERVICE MANUAL

OWNERS MANUAL U.S. Patent 6,223,548 U.S. Patent D 362,905 U.S. Patent 6,502,414

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz

Manual for MC21A SETUP INSTRUCTIONS

Manual update 2016 MC37/MFC3600

Manual for MC37/MFC3600

Manual for MC91 SETUP INSTRUCTIONS

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Operation and Maintenance Manual 120V/60HZ

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

PROFESSIONAL AIR MOVER OWNER S MANUAL

FAN-FORCED UTILITY HEATER

48 MaxxAir Portable Evaporative Cooler Owner s Manual

ELECTRIC FIREPLACE OWNER S MANUAL

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

User s Manual & Operating Instructions

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

EVAPORATIVE COOLER W

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Operation and Maintenance Manual 120V/60HZ

XC Portable Air Conditioning

Zeus Extreme Owner's Manual

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

Introduction. Features. Benefits. Records

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Portable Evaporative Air Cooler Safety & Maintenance Guide User tips and safety instructions

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Stand Fan. English. Owner s Guide. Model F R

Thanks for shopping with Improvements! Evaporative Air Cooler with Adjustable Flow Valve Item #437979

Owner s. 18 Misting MF18W. To view

CIRCULATOR Owner s Manual

User s Manual and Operating Instructions

FM-ME EDGER/SCRUBBER FLOOR MACHINE. Model: PARTS & OPERATING MANUAL

PORTABLE AIR CONDITIONER OWNER S MANUAL

Owner s. Coolerr. comply. To view

Owner s Manual.

With Remote Control. English

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

HI Industrial Utility Heater HI Soleus Air International

6,223,548 FOR ELECTRIC MODELS PAC2K36EP PAC2K48EP

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

High-Velocity Floor Fan

User s Manual and Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

Installation and Maintenance Manual Please retain this manual for future reference.

Xaact Spot. Xaact Hot Spot

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Arctic EVAPORATIVE COOLER USER MANUAL

ULTRASONIC HUMIDIFIER

Instruction Leaflet. Read instructions before operating. Retain for future reference.

PORTABLE AIR CONDITIONER OWNER S MANUAL

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

ELECTRIC STOVE HEATER Models: FS2213B

1 HP Air Mover. Owner s Manual

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

With Remote Control. English. Model

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

Portable Air Cleaner. Owner s Manual. The Science of Clean Air READ AND SAVE THESE INSTRUCTIONS. For Model 1606X Series Air Cleaner JULY

16 OUTDOOR MISTING FAN

Electric Garage Heater

Owner s Manual BONAIRE. Model 3500M, 4200M

ELECTRIC FIREPLACE INSTRUCTION MANUAL. Item No: 050-HA Model No. FP405R-QA

6-Gallon Carpet Extractor Series

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Portable Room Air Conditioner and Heat Pump

model PIVOT HEAT vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Speak your mind

Split Portable Air Conditioner

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

Phoenix AirMAX - Radial Air Mover

Thanks for shopping with Improvements! Deco Breeze 16 Deco Floor Standing Fan - Sutter Item #472969

Mobile Evaporative Cooler. Use & Care Guide MC18M INDEX

MINI ELECTRIC CONVECTION HEATER

OIL FREE HEATER RADIATEUR SANS HUILE CALEFACTOR SIN ACEITE AQUECEDOR SEM ÓLEO

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Transcription:

PORTACOOL CYCLONE OWNER S MANUAL

TABLE OF CONTENTS READ AND SAVE THESE INSTRUCTIONS CONTENTS: QUICK SETUP GUIDE... page 2 PRODUCT OVERVIEW... pages 3-7 SAFETY INFORMATION... page 8 GENERAL OPERATION... pages 9-10 MAINTENANCE AND STORAGE... page 11 TROUBLESHOOTING... pages 12-13 TECHNICAL SUPPORT AND WARRANTY... pages 14-15 EXPLODED VIEWS... pages 16-20 WIRING DIAGRAM... page 21 FREQUENTLY ASKED QUESTIONS... page 22 STOP DO NOT RETURN! For questions or comments, please call Portacool Customer Service at 936-598-5651.

QUICK SET UP 1 2 3 4 Remove box and palette Position product on level surface Plug into appropriate outlet Fill sump or attach water hose 5 For setup, pads should appear wet before starting the fan. Check the water gauge to monitor water level in tank.the water flow valve on each unit is set at max flow. However, ensure the knob is turned completely to the left before use. Turn to the left to increase water flow. Less water is required for cooling in more humid environments. Fill the tank, then turn on the pump switch and the fan. Models: PAC2KCYC01, PAC2KCYC01A, PACCYC02, PACCYC02A, PACCYC03, PACCYC03A, PACCYC04, PACCYC04A Models: PACCYC06

CYCLONE 3000 OVERVIEW PAC2KCYC01, PAC2KCYC01A Control Panel Adjustable Louvers Adjustable Louvers Water Adjustment Valve Hose Connection 3 Locking Casters Drain Plug Electrical Plug

CYCLONE 3200 OVERVIEW PACCYC04, PACCYC04A Control Panel Adjustable Louvers Adjustable Louvers Hose Connection Water Adjustment Valve Locking Casters Drain Plug Electrical Plug 4

CYCLONE 2000 OVERVIEW PACCYC02, PACCYC02A Control Panel Adjustable Louvers Adjustable Louvers Electrical Plug Water Adjustment Valve 5 Locking Casters Drain Plug Hose Connection

CYCLONE 2200 OVERVIEW PACCYC03, PACCYC03A Control Panel Adjustable Louvers Adjustable Louvers Electrical Plug Water Adjustment Valve Locking Casters Drain Plug Hose Connection 6

CYCLONE 1000 OVERVIEW PACCYC06 Control Panel Adjustable Louvers Manual Water Fill 7 Recessed Casters Drain Plug Water Hose Connection Electrical Cord

SAFETY INFORMATION OPERATION WARNINGS 1) Not intended for use by children 2) Not intended for use by persons with reduced physical, sensory, or mental capabilities 3) Not intended for use by persons with lack of experience and knowledge, unless they have been given instruction and are supervised during operation 4) Children should be supervised to ensure they do not play with the appliance SAFE OPERATION To reduce the risk of electric shock, fire, or injury: Do not operate any product with a damaged cord or plug. Discard product or return to place of purchase for examination and/or repair. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area so it will not be tripped over. Read instructions and labels carefully. Always unplug the electric cord to the Portacool evaporative cooler before performing inspections or repairs. Plug into three-prong grounded GFCI protected electrical receptacle only. Do not step on or roll over power cord with heavy or sharp objects. Do not operate evaporative cooler unless all pads are securely in place. Remove the plug from the electrical receptacle by pulling on the plug and not the cord. Test the GFCI receptacle or breaker monthly to ensure it is functioning properly. Do not operate near open containers of flammable liquids or gases. Ensure evaporative cooler pumps are running continuously to saturate and wet combustible media when used in close proximity to open flame or spark producing activities. A distance of at least 35 feet away from open flame or sparks is recommended to ensure safe operation. Never wash the evaporative cooler cabinet with a garden hose; water may harm the motor and electrical system. If the product is damaged or malfunctions, do not continue to operate it. Refer to the warranty, troubleshooting or FAQ section, call Portacool, LLC, Technical Support at 1-888-266-5243, or email support@portacool.com. 8

GENERAL OPERATION Electrical Connection PRODUCT MUST BE IN UPRIGHT POSITION WITH COOLING PADS INSTALLED! All models utilize a single power cord and control switches. Before connecting the plug to an outlet, ensure there is no standing water where the cord may lie or where the operator is standing. The use of separate multiple outlet devices is not recommended. When making electrical connections, ensure compliance to local and national codes. Use only with GFCI Protected Receptacles. Please refer to the Barcode Product Label on the side of the product for specific electrical requirements. OPERATING PROCEDURES Specifications Each Portacool evaporative cooler has its own set of operational specifications, sizes, weights, voltage frequency, current requirements, etc. Please ask for the specifications for your model from your distributor, check the serial number plate, or visit www.portacool.com for the specifications for your product. Placement of the Portacool Evaporative Cooler There are three primary considerations when deciding where to place the Portacool evaporative cooler. 1) Make sure there is a clear, unobstructed path to provide maximum airflow. 2) If the evaporative cooler is positioned on a raised platform, ensure the platform constructed for holding the product is stable, well constructed, and will not allow the product to tip over and that it allows for the full weight of the evaporative cooler including water in the tank. The product must be level and in the upright position. 9

3) If placed near a wall or other obstruction, position the product a minimum of 3 feet (0.9 meters) from the wall or obstruction with pads facing the wall. This allows the unrestricted flow of warm air to the cooling pad side of the product. When using multiple products in close proximity, be sure to aim the product so the air flows complement each other to achieve maximum cooling capacity. Starting the Pump and Adjusting the Water Flow Once the water tank is full, moving the pump switch to the ON position will turn on the pump. When initially turning on the pump, the level in the water tank will drop suddenly and restart the flow of supply water. This is a normal condition, as the cooling pads require a large amount of water for proper wetting. When the Portacool evaporative cooler is new, the new pads will require an initial breaking-in period. This period is required for the pads to begin readily absorbing water. It may require up to a week to achieve maximum efficiency. It is important to ensure that the spray bar is properly adjusted when first starting the water flow in the Portacool evaporative cooler. Increasing the flow using the water flow valve (see Quick Setup on page 2) makes this adjustment. Proper water adjustment should leave the pads saturated with water, but not flooded. Pads should appear wet. However, cascading amounts of water can actually reduce cooling efficiency. Proper adjustment will prevent problems and increase cooling capacity. When properly adjusted, one or two dry streaks will appear across the pads. When turning the evaporative cooler off at the end of the day or week, the pump should be turned off about 15 minutes before the fan to allow the cooling pads to dry. This will increase the life of the pads. Starting the Portacool Evaporative Cooler COOLING PADS MUST BE INSTALLED AND CASTER LOCKS MUST BE ENGAGED Start the fan by turning the fan switch to the ON position. Step slowly through the speeds allowing the fan to obtain its full speed at the LOW speed before going to HIGH. 10

MAINTENANCE & STORAGE MAINTENANCE 1) Keep the product clean to ensure peak operating performance. 2) The rugged, corrosion-resistant construction ensures low maintenance will be required. However, in dusty or dirty environments, optional filters are available from your distributor or at www.portacoolparts.com. Daily Maintenance The pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the cooling pads to dry out and extend their life. This also helps control the growth of mildew, mold, bacteria, and other odor-causing elements. Weekly Maintenance The product should be shut down and the water tank should be drained once a week. Closing the water flow valve and removing the drain plug will accomplish this. Once the water tank is drained and the power disconnected, the pads may be removed to allow cleaning of the water tank. Dust may collect in the water tank over time. Replace pads in correct airflow direction, referring to the label on the pads. Storage 1) Drain all water from the water tank and wipe clean, ensuring the pads and water tank are completely dry. 2) Roll up the electrical power cord and secure it to ensure it will not be rolled over, tripped over, or caught in equipment. 3) Cover the product completely to prevent dust build-up and store in a dry area. This also helps to prevent damage to the pads. Optional dust covers are available from your distributor or at www.portacoolparts.com. The pump should be turned off approximately 15 minutes before the fan is turned off. This will allow the cooling pads to dry out and extend their life. This also helps control the growth of mildew, mold, bacteria, and other odor-causing elements. 11

TROUBLESHOOTING The Portacool evaporative cooler consists of three systems the fan system, the electrical system, and the water system. It is important to determine with which of the systems the problem is associated. Certain problems may be associated with more than one system. A careful check of all systems should be made to fully understand the extent of the problem. CAUTION DISCONNECT POWER BEFORE REMOVING COOLING PADS FROM THE PRODUCT! NOTICE POWER CORD MAY BE REPLACED ONLY BY THE MANUFACTURER OR QUALIFIED AGENT! Repair and Replacement Procedures Ensure all water is removed from the Portacool evaporative cooler and all power is disconnected. Remove all impediments to access the component you are checking or replacing. REPLACING THE COOLING MEDIA PADS The flap must be removed to allow access to the cooling pads. Start with the center pad, which can be tilted out from the top and lifted out of the drain trough. The two pads to either side of the center pad may then be removed in the same manner. To remove the two outside pads, they must first be pulled sideways toward the center of the Portacool evaporative cooler until they clear the side retainer before removing in the same manner as the other pads. 1) Locate the screw in the rear of the unit on the upper right side of the pad flap. 2) Remove screw and lower pad flap to vertical position. 3) Once the pad flap is moved, grasp the middle pad and tilt out at a 90 degree angle. 4) Pull the pad up to remove from unit. Repeat for other pads. 12

The following troubleshooting guide is intended to address the most common symptoms which may occur. If you are unable to resolve the issue, please call Technical Support. Turn off all power to the cooler before attempting to troubleshoot any of the following symptoms. SYMPTOM POSSIBLE CAUSES REMEDY Product fails to start or deliver air 1. No electrical power to product 1. Check power A. Circuit breaker tripped A. Reset breaker* B. GFCI tripped B. Reset GFCI* C. Cord(s) unplugged or damaged C. Plug in cord(s) or replace if damaged * If condition persists, call electrician 2. Motor overheated and/or frozen 2. Replace motor Product starts but air delivery inadequate 1. Insufficient air exhaust 1. Open windows or doors 2. Insufficient water pad not wet 2. Check water distribution system A. Cooling pads plugged A. Clean or replace pads B. Dry streaks on pads B. Check water level C. Large dry spots on pads C. Make sure cooler is level, clean spray bar D. Pump not working D. Clean or replace pump E. Loose water connections E. Check for leaks and correct Water draining from cooler 1. Float arm improperly adjusted 1. Adjust float to proper level 2. Seat in float valve leaking 2. Replace float valve 3. Drain bushing/cap not tight 3. Tighten fitting and/or cap Musty or unpleasant odor 1. Stale or stagnant water in sump 1. Drain, flush and clean sump 2. Pads mildewed or clogged 2. Replace pads 3. Pads not completely wet before cooler is turned on 3. Turn on pump before starting fan Knocking, shaking, or rattling sounds 1. Loose parts 1. Check and tighten where needed 2. Blower wheel loose or rubbing 2. Inspect and adjust, or replace Water droplets in the discharge air stream 1. Too much water delivered to the cooling pads 1. Make sure pads are properly positioned in the frames and product is level 2. Outdoor humidity level is too high or it is raining 2. Use cooler as a fan only (turn pump off) or discontinue use of product until 3. Leaking hose outdoor humidity level drops. 3. Tighten connection or replace hose

TECHNICAL SUPPORT TECHNICAL SUPPORT Technical support and service is available directly from your distributor or call Portacool, LLC Technical Support Hot Line at 888-266-5243 for the distributor nearest you. You may also contact the Support Hot Line for consultation on troubleshooting and parts replacement. Please have serial number and model number of product available. WARRANTY AND REPLACEMENT PARTS PORTACOOL Evaporative Cooler Limited Warranty For one (1) year from date of purchase, Portacool, LLC (hereafter Portacool ) warrants any original component part or parts of its Portacool portable evaporative coolers (the Equipment ) that are found, upon examination by factory-authorized personnel, to be defective in material or workmanship, excepting, however, that the following component motors shall be warranted by Portacool for a period of three (3) years from the date of purchase: MOTOR-013-04, MOTOR-010-07, MOTOR-012-06, MOTOR-012-05 and MOTOR-034-01. All transportation charges for shipment of the Equipment and/or its component parts that are submitted for replacement or repair under this warranty must be borne by the purchaser. If the Equipment and/or its original component parts develop a defect covered by this limited warranty within the applicable time periods described above, the same will be repaired or replaced at Portacool s option. In the case of a breach of any implied or written warranty relating to the Equipment and/or its component parts, Portacool shall not be liable for any incidental or consequential damages, and the limits of liability against Portacool for any such breach shall not exceed the cost of replacement or repair of the Equipment. This warranty is void if the Equipment and/or its component parts are found to have been misused, abused, repaired by or tampered with by unauthorized or unqualified personnel. 14

RETURNS Returned Merchandise Authorization (RMA) Procedures All Portacool evaporative coolers, parts, or materials being returned to Portacool, LLC for warranty replacement or repair require an RMA (Return Merchandise Authorization) number. Warranty parts can be replaced by: 1. The distributor can purchase the part with an RMA number and will only be charged for the cost of the part, not for the shipping. When the defective part is returned freight paid, the distributor s account will be credited for the cost of the part. 2. The defective part need to be returned to Portacool, LLC, labeled with the RMA number within 90 days of receipt of replacement parts. 3. The customer / distributor can call Tech Support to get an RMA number to send the defective part back to Portacool, LLC. Once the part is received by Portacool, a replacement part will be sent at no charge. Information needed to get an RMA number: 1. The product serial number or manufacturer date code 2. The product model number (ex. PAC2K363S) 3. The part number or description of the part to be replaced Only major component parts need an RMA number, i.e. fans, motors, pumps, and some plumbing parts. For replacement of small parts, the serial and model numbers are still required, but the parts do not need to be returned to Portacool, LLC. For warranty replacement parts call Portacool Technical Support at 1-888-266-5243. FAX: 936-598-1431. Shipping Address Mailing Address: Portacool, LLC Portacool, LLC 721 FM 2468 P.O. Box 2167 Center, Texas 75935 Center, Texas 75935 To expedite your request, please submit the RMA form found on our website at info.portacool.com/returnshold 15

CYCLONE 1000 PARTS PACCYC06 PACCYC06 Revised 02/24/15 9 ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 1 ACCDOOR-C1-714 WATER FILL DOOR 22 PUMP-CYC-3 CYCLONE PUMP -OK4000 2 ACCFRM-C1-715 FILL DOOR FRAME 23 S-003 5/16-18 x1/2 TRUSS HEAD SCREW (2EA) 24 34 26 17 3 BLOWER-WHL-2CW CYCLONE 2000 BLOWER WHEEL - CW 24 S-007 5/16-18 x 3/4 TRUSS HEAD SCREW (16EA) 18 33 6 35 32 4 BLWEHSG-C1-7162 BLOWER HOUSING 25 S-011 #8 x 9/16 WASHER HEAD SCREW 5 BLWRCVR-C1-7163 BLOWER HOUSING COVER 26 S-818-58PPH 8-18 x 5/8 PAN HEAD SCREW (24EA) 17 19 30 10 8 17 36 14 6 BOX-UL-02 1 & 2 SPEED ELECTRICAL BOX 27 S-1016-1PPH 10-16x1 PHILLPS SELF-TAP SCREW (12EA) 7 CASTER-3-NL 3 NON-LOCKING CASTER 28 SGTFRM-C1-711 SIGHT GLASS FRAME FOR CYCLONE1000 8 CLAMP-01 1/2 WIRE TUBING CLAMP 29 SGTGLS-C1-719 SIGHT GLASS W/EXTERNAL FRAME 23 31 8 20 9 COVER-C1-716 TOP TRAY COVER, CYCLONE1000 30 SPIN-FTG-02 1/4 SPIN FITTING FOR 16 UNIT 10 CTRL-2SPD-01 2-SPEED SWITCH SET 31 SPLASHGUARD-C1 SPLASH GUARD CYCLONE1000 2 26 1 25 28 23 16 11 29 27 7 37 4 3 25 5 8 26 25 25 15 39 36 21 25 26 25 26 13 11 CYCLONE-H-10 CYCLONE 1000 HOUSING (BLACK) 32 SPRAY-ACC-01 #012 NYLON CLIP 12 DRAIN-PLUG-01 1/4 NPT PLUG #P-28 33 SWITCHPL-2SPD-T SWITCH COVER PLATE - 2SPD(TPI) 13 FLOAT-CYC-717 FLOAT FOR CYCLONE1000 34 TRAY-ACC-C1 BOTTOM DRIP TRAY CAP/COVER 14 FRNTPNL-C1-7112 FRONT PANEL, WITH LOUVERS 35 TRAY-C1-713 DRIP TRAY WITH CAP/VALVE 15 HOSE-FTG-09 1/2 BARB FLOW RESTRICTOR 36 TOG-BOOT-01 BLK RUBBER TOGGLE-SWITCH BOOT 16 MOTOR-017-01 CYCLONE 1000 2-SPEED MOTOR (B-O) 37 TUBE-01 1/2 ID SOFT PLASTIC TUBE 17 MTR-BRKT-C1 BLOWER HOUSING SUPPORT BRACKET 38 WASHER-04 5/16 LOCK WASHER 18 MUC-ACC-02 CHRISTMAS TREE FASTENER (5EA) 39 FLOAT-CYC-03 FLOAT VALVE FOR CYCLONE UNITS 19 PAD-BRACKET-C1 PAD RETENTION BRACKET 40 PAC-PLB-01 INLET HOSE ADAPTER 12 23 38 22 20 PADMF4022/G 4 x12 x22 MICROFLUTE 45/46 21 POWERCORD-02F 10 POWER CORD WITH BRASS NUT/WASHER 16

CYCLONE 3000 PARTS PAC2KCYC01 PAC2KCYC01A 24 16 14 REVISED 02/16/2015 ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 18 PAC-PLB-01 INLET HOSE ADAPTER 4 2 BLOWER-01 BLOWER HOUSING 19 PAD6022.5/26 KUUL PAD SET FOR CYCLONE 3 BLOWER-WHL-01 BLOWER WHEEL 20 POLY-FTG-06 90 DEG. FITTING FOR SIGHT TUBE 5 11 25 29 10 28 4 BONNET-05 BONNET 21 POWERCORD-02F 10ft POWER CORD W / DOME STRAIN RELIEF 5 BOX-UL-02 2 SPD UL ELECTRICAL BOX 22 PUMP-BRACKET-#4 ALUM. BAR PUMP BRACKET 6 CAPACITOR-01 PSU 25-30 CAPACITOR 23 PUMP-CYC-3 CYCLONE PUMP - OK400 33 7 CAPBOOT-01 WATER PROOF BOOT FOR CAPACITOR 24 S-006 TEC SCREW S006 31 30 20 22 10 12 33 32 19 8 CASTER-3-L 3" LOCKING CASTERS 25 S-009 10/24 x 3/3 TRUSS HEAD SCREW 9 CASTER-3-NL 3" CASTERS 26 S-014 5/16 x 1" TRUSS HEAD SCREW 10 CLAMP-01 1/2" WIRE SPRING CLAMP 27 S-017 5/16-18 x 1.5" TRUSS HEAD SCREW 13 11 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 28 SPRAY-CYC-01 16" SPRAY BAR 21 27 34 20 15 18 23 12 CTRL-VLV-BRKT-1 VALVE-01 MOUNTING BRACKETS 29 SPRAY-ACC-04 SPRAY BAR CLIP 13 DRAIN-PLUG-01 DRAIN PLUG 30 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 14 FLAP-05 FLAP 31 TOG-BOOT-01 RUBBER TOGGLE SWITCH BOOT (2) 15 FLOAT-CYC-03 FLOAT VALVE FOR CYCLONE UNITS 32 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 26 9 2 3 16 LOUVERS-CYC-16 CYCLONE 3000 LOUVER W/MESH 33 TUBE-01 PUMP TO SPRAY BAR TUBING 17 MOTOR-013-07 1/3 HP - 2SPD MOTOR 34 TUBE-03 SIGHT TUBE 1 8 17 7 6 17

CYCLONE 2000 PARTS 24 Revised 02/04/2015 PACCYC02 4 PACCYC02A 26 13 9 26 22 25 15 10 18 19 5 31 11 30 28 ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 1 BLOWER-02 BLOWER HOUSING - CYCLONE2000 17 MOTOR-016-01 CYCLONE2000-2SPD MOTOR 2 BLOWER-WHL-2CW CYCLONE2000 BLOWER WHEEL (PART 1) 18 PAC-PLB-14 INLET HOSE ADAPTER 3 BLOWER-WHL-3CCW CYCLONE2000 BLOWER WHEEL (PART 2) 19 PAD6019/22 KUUL PAD SET FOR CYCLONE2000 4 BONNET-06 22.5" EXTRUDED BONNET-CYCLONE2000 20 PUMP-BRACKET-5 PUMP MOUNT BRACKET 5 BOX-UL-02 1 & 2 SPD UL ELECTRICAL BOX 21 PUMP-CYC-3 CYCLONE PUMP - OK400 6 CAPACITOR-04 RUN CAPACITOR FOR CYCLONE2000 22 S-002 TEC SCREW S006 7 CASTER-3-L 3" LOCKING CASTERS 23 S-007 10/24 x 3/3 TRUSS HEAD SCREW 8 CASTER-3-NL 3" CASTERS 24 S-011 5/16 x 1" TRUSS HEAD SCREW 9 CLAMP-01 1/2" WIRE SPRING CLAMP 25 SPRAY-CYC-02 SPRAY BAR 29 8 16 27 12 14 20 21 9 13 10 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 26 SPRAY-ACC-01 SPRAY BAR CLIP 11 CTRL-VLV-BRKT VALVE-01 MOUNTING BRACKETS 27 SPIN-FTG-02 SPIN FITTING FOR 16" UNIT 12 DRAIN-PLUG-01 DRAIN PLUG 28 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 13 FLAP-CYC-2 FLAP/SPLASHGAURD-CYCLONE2000 29 TOG-BOOT-01 RUBBER TOGGLE SWITCH BOOT (2) 14 FLOAT-CYC-03 FLOAT VALVE 30 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 23 7 15 LOUVERS-CYC-11 LOUVER W/MESH - CYCLONE2000 31 TUBE-01 PUMP TO SPRAY BAR TUBING 16 POWERCORD-02F 10ft POWER CORD W / DOME STRAIN RELIEF 17 1 2 3 6 18

CYCLONE 2200 PARTS PACCYC03 13 24 Revised 02/25/15 24 PACCYC03A 26 22 4 ITEM# PART # DESCRIPTION ITEM# PART # DESCRIPTION 1 BLOWER-02 BLOWER HOUSING - CYCLONE2000 16 MOTOR-016-01 CYCLONE2000-2SPD MOTOR 2 BLOWER-WHL-2CW CYCLONE2000 BLOWER WHEEL (PART 1) 17 PAC-PLB-14 INLET HOSE ADAPTER for CYCLONE2000 3 BLOWER-WHL-3CCW CYCLONE2000 BLOWER WHEEL (PART 2) 18 PAD6019/22 KUUL PAD SET FOR CYCLONE2200 4 BONNET-06 22.5 EXTRUDED BONNET-CYCLONE2000 19 POWERCORD-02F 10ft POWER CORD W / DOME STRAIN RELIEF 15 26 9 25 5 BOX-UL-02 1 & 2 SPD UL ELECTRICAL BOX 20 PUMP-BRACKET-6 PUMP MOUNT BRACKET-CYCLONE2000 6 CAPACITOR-04 RUN CAPACITOR FOR CYCLONE2000 21 PUMP-CYC-3 CYCLONE PUMP - OK400 27 5 10 17 30 9 11 29 18 7 CASTER-3-L 3 LOCKING CASTERS 22 S-002 #8 x 3/4 TEK SCREW 8 CASTER-3-NL 3 CASTERS 23 S-007 5/16-18 x 3/4 TRUSS HEAD SCREW 9 CLAMP-01 1/2 WIRE SPRING CLAMP 24 S-011 #8 x 9/16 WASHER HEAD SCREW 10 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 25 SPRAY-CYC-02 SPRAY BAR FOR CYCLONE2000 20 11 CTRL-VLV-BRKT VALVE-01 MOUNTING BRACKETS 26 SPRAY-ACC-01 SPRAY BAR CLIP 12 DRAIN-PLUG-01 DRAIN PLUG 27 SWITCHPL-2SPD-T 2 SPEED SWITCH PLATE 28 19 8 7 12 14 21 9 13 13 FLAP-CYC-2 FLAP/SPLASHGAURD-CYCLONE2000 28 TOG-BOOT-01 RUBBER TOGGLE SWITCH BOOT (2) 14 FLOAT-CYC-03 FLOAT VALVE 29 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 15 LOUVERS-CYC-11 LOUVER W/MESH - CYCLONE2000 30 TUBE-01 PUMP TO SPRAY BAR TUBING 23 16 19 1 2 3 6

CYCLONE 3200 PARTS 14 PACCYC04 4 Revised 02/25/15 PACCYC04A ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 1 BASE-CYCLONE CADDY FRAME 18 PAC-PLB-14 INLET HOSE ADAPTER 25 28 2 BLOWER-01 BLOWER HOUSING 19 PAD6022.5/26 6 x12 x22 KUUL PAD FOR CYCLONE 16 29 32 3 BLOWER-WHL-01 BLOWER WHEEL 20 POLY-FTG-06 90 DEG. FITTING FOR SIGHT TUBE 4 BONNET-05 BONNET 21 POWERCORD-02F 10ft POWER CORD W / DOME STRAIN RELIEF 24 10 34 12 32 19 5 BOX-UL-02 2 SPD UL ELECTRICAL BOX 22 PUMP-BRACKET-#4 ALUM. BAR PUMP BRACKET 6 CAPACITOR-01 PSU 25-30 CAPACITOR 23 PUMP-CYC-3 CYCLONE PUMP - OK400 7 CAPBOOT-01 WATER PROOF BOOT FOR CAPACITOR 24 S-006 TEC SCREW S006 31 30 5 11 22 10 8 CASTER-3-L 3 LOCKING CASTERS 25 S-009 10/24 x 3/3 TRUSS HEAD SCREW 9 CASTER-3-NL 3 CASTERS 26 S-014 5/16 x 1 TRUSS HEAD SCREW 10 CLAMP-01 1/2 WIRE SPRING CLAMP 27 S-017 5/16-18 x 1.5 TRUSS HEAD SCREW 21 23 11 CTRL-2SPD-01 2-SPEED SWITCH ASSEMBLY 28 SPRAY-CYC-01 16 SPRAY BAR 12 CTRL-VLV-BRKT-1 VALVE-01 MOUNTING BRACKETS 29 SPRAY-ACC-04 SPRAY BAR CLIP 9 8 27 8 1 9 20 33 17 13 15 14 18 13 DRAIN-PLUG-01 DRAIN PLUG 30 SWITCHPL-2SPD 2 SPEED SWITCH PLATE 14 FLAP-05 FLAP 31 TOG-BOOT-01 RUBBER TOGGLE SWITCH BOOT (2) 15 FLOAT-CYC-03 FLOAT VALVE FOR CYCLONE UNITS 32 TUBE-01 PUMP TO SPRAY BAR TUBING 16 LOUVERS-CYC-16 CYCLONE 3000 LOUVER W/MESH 33 TUBE-03 SIGHT TUBE 17 MOTOR-013-07B 1/3 HP - 2SPD MOTOR (BO) 34 VALVE-01 PUMP TO SPRAY BAR CONTROL VALVE 27 26 7 3 2 6 20

21 WIRING DIAGRAM

FREQUENTLY ASKED QUESTIONS Q. WHAT ASSEMBLY IS REQUIRED? A. None. Portacool Cyclone units are ready to use right out of the box. Q. HOW DO I PREPARE MY PORTACOOL PRODUCT FOR STORAGE? A. Drain the product, dry out the pads, cover the product, and store in a dry place. Q. I JUST RAN THE COOLER FOR THE FIRST TIME AND THERE S AN UNPLEASANT ODOR! A. The pads, located in the back of your Portacool product, have never been wet before. The resin in the pads will emit an odor the first time you wet them that lasts approximately one to three weeks. Keep the product in an open area until the odor goes away or put a capful of laundry softener directly in the tank in the bottom of your product. After approximately two weeks of operation, the odor should disappear. Q. MY PORTACOOL PRODUCT ISN T PUTTING OUT ANY COOL AIR. A. First, make sure the water source and electricity source are connected and working. Second, check to see if the pads are damp. If not, adjust the water flow with the water adjustment valve. Third, make sure there is water in the tank. It should be allowed to fill before you turn the pump on. Q. WHAT IS THE BEST ENVIRONMENT TO PRODUCE THE MOST COOL AIR? A. For optimum performance, the temperature should be 85 F or higher and the relative humidity should be below 75%. However, Portacool products will reduce the temperature in almost any environment, making it more pleasant. Q. HOW OFTEN DO PADS HAVE TO BE REPLACED? A. Depending on the quality of maintenance and frequency of use, pads typically last up to five years. MISTING SYSTEMS? A. Misting units spray a shower of water into the air that will collect on people, objects, equipment, floors, etc. Portacool products use the process of evaporation to produce cooler air, but do not discharge a mist. Q. WHERE CAN I BUY REPLACEMENT PARTS? A. Replacement parts may be purchased from any Portacool product distributor or directly from Portacool Parts/Technical Support department. You may also visit www. portacoolparts.com to order online. Q. WHAT IS THE AMOUNT OF MOISTURE PRODUCED? A. An increase in humidity of approximately two to five percent is produced, depending on the temperature and humidity of the environment. This increase is not noticeable in a ventilated area where the air produced by the unit is exhausted. Q. HOW LONG WILL THE WATER SUPPLY LAST IN THE TANK? A. With no direct water source available, the water will evaporate in a filled water tank within two to 10 hours of operation, depending on the water capacity of the product, ambient conditions, temperature, and humidity. A water source for refilling the tank is recommended by the manufacturer. Q. WHERE ARE THE MODEL AND SERIAL NUMBERS FOUND? A. The model number can be found on a metal plate on the outside of the product. Model numbers begin with the letters PAC. Serial numbers are all-digits. Q. WHAT IF MY QUESTIONS AREN T ANSWERED HERE? A. Our Tech Support staff is available 8 a.m. to 5 p.m. Central Time, Monday though Friday at 1-888-COOL-AID or you can e-mail them at support@portacool.com. Q. WHAT IS THE DIFFERENCE BETWEEN EVAPORATIVE COOLING AND

The manual is available in other languages. To download a digital copy, please visit www.portacool.com. CUSTOMER SERVICE CONTACT 1-936-598-5651 1-800-695-2942 ORDERS@PORTACOOL.COM TECHNICAL/PARTS CONTACT 1-936-598-5651 1-888-COOLAID SUPPORT@PORTACOOL.COM VISIT PORTACOOL.COM OR CALL 1-936-598-5651 FOR MORE INFORMATION El manual está disponible en otros idiomas. Para descargar una copia digital, por favor visite www.portacool.com. Le manuel est disponible en d autres langues. Pour télécharger une copie numérique, se il vous plaît visitez www.portacool.com. والدليل هو متاح في اللغات الأخرى. لتحميل نسخة رقمية يرجى ز يارة www.portacool.com MANR0002 Portacool, LLC Manufacturer of Portacool portable evaporative coolers and KÜÜL Pads evaporative media 709 Southview Circle Center, Texas 75935 936-598-5651 www.portacool.com www.kuulpads.com