Genesis Touch Installation Readiness

Similar documents
Genesis DM Installation Readiness

Getting Started. Genesis Touch System

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Meet Your Neato Robot

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

Alarm Getting Started

English Français Español Italiano Deutsch... 73

IQ PANEL USER GUIDE SMARTHOME.

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

T1 BEDSIDE MONITOR GUIDELINE

General Skills. yes. Device controls, buttons, indicators, and connectors

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Ion Gateway Cellular Gateway and Wireless Sensors

Halton SAFE / 7.14 user guide and installation instructions

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

IRIS Touch Firmware Enhancements and Additions from Version to Version

CNAP MONITOR 500 HD QUICK GUIDE. This Quick Guide DOES NOT REPLACE the user manual!

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

BeneVision TM80 Telemetry Monitor

English. Meet Your Neato Robot

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Control-R Wi-Fi Module

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

G4S SMARTalarm User Guide

WiFi GSM APP Smart Home Security System

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

wireless. web-based. worthy of the name RACO.

CORAL MANTA User Guide

Before you install ProSeries Express Edition software for network use

ADT Pulse Mobile App Nest Thermostat

APP Function Introduction

Door/Window Sensor. Set-Up Guide

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

PRO Installation. Thermostat Wi-Fi

Added password for IP setup page : Password must be in IP format!

IDoorBell Fon DP68 Quick Installation Guide

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Midco SmartHOME Quick Start Guide. Learn how to protect the things that matter most using this Midco SmartHOME instruction guide.

Laptop / PC Programming Manual

Alarm System SECURE AS 302

Connex Integrated Wall System 2.2 Software Version

IP/Network Doorbell. Quick Installation Guide V3.1

Lyric Gateway. User Reference Guide. Ref: LCP300-L/LCP300-LC /16 Rev A

User Guide English. Manual Version 1.0

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

S6 Titan Security System. Wi-Fi and 3G GSM

Fall Detection and Alert

Wi-Fi 3-IN-1 Trio Sensor

Inactivity Alert Sensor

N-600. Pulse Oximeter Home Use Guide

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

Security GSM Alarm System

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Intelligent Wireless GSM Alarm System

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

FCD-wire Contents. List of Figures

User Manual 561_U. WiFi Thermostat 561. Introduction 10/16

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

Installing ProSeries software for stand-alone use

Ness acomms Install & User Manual

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

Honeywell Total Connect Remote Services

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

WS WEATHER STATION

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0

SIMPLIFIED HOME SECURITY AND CONTROL

2GIG GC3 Security & Automation System. Fingertip Guide

Wise&Cute WSC Series IP Cameras User-Manual

Door/Window Sensor. Set-Up Guide

Quick Start Guide. Wi-Fi Color Touchscreen Programmable Thermostat. RTH9590 Wi-Fi With Voice Control

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

MOBILE CALL GSM Alarm System User s Manual

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

Lyric T6 & T6R Smart Thermostat

Wiring Diagram for Nuheat SIGNATURE, HOME & Element Thermostats

Supervised Security System Owner's Guide

Wireless Weather Station. Table of Contents

Contents. Glossary

Quick Guide for SmartShaker 2

Lynx Touch L5100 Technical Training. WiFi Setup

Cellular Monitoring System

Digital Thermometer with Ice Alert and Clock

S82967 FAQS CONTENTS

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Color Forecast Station. Table of Contents

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Transcription:

Genesis Touch Installation Readiness Step by Step Readiness 1 2015 Honeywell International All Rights Reserved CP412.01

Overview Who should attend this presentation? Installers of Genesis Touch monitors and Telemonitoring clinicians Agenda Review Genesis Touch monitor exterior, i.e. screen, buttons Identify peripherals and review what's new How to check and upgrade monitor software Evaluate transmission options Pair peripherals Advanced settings Questions 2 2015 Honeywell International All Rights Reserved CP412.01

Resources to have on hand Genesis Touch monitor with all peripherals Blood Pressure device (Do you have various size options available?) Is this a UA-767PBT-Ci? Or an older model? SpO2 (Oxygen) May be a Contec, Choicemmed or Nonin brand wireless oximeter Scale BT wireless May be HomMed, A&D or NCI Technologies scale Glucose Meter with Adapter (optional) May be a Bayer or J&J model glucose meter Adapter cable will be blue or black, including a card to look up use information Patient use flier Genesis Touch Patient Telemonitoring Instructions (optional). Genesis Touch Getting Started Guide, User Manual Available on the website or from customer service https://www.honeywelllifecare.com/customer-service/genesis-touch-manuals/ 3 2015 Honeywell International All Rights Reserved CP412.01

Genesis Touch Buttons 1. Power button 2. Volume 3. Camera 1 2 3 4 5 6 Inactive buttons, usable or shown only when navigating password protected menus: 4. Return Key Returns to previous screen, step or option. Use to return to Genesis Touch. 5. Home Key If held down while behind password, use return key to go back. 6. Recent Apps Key Display recent apps, close apps or access task manager. 4 2015 Honeywell International All Rights Reserved CP412.01

The Settings Menu and Status Select the Settings icon on the touch screen. You will see the following screen. Select the Status button: 5 2015 Honeywell International All Rights Reserved CP412.01

Status Screen Signal Strength Accessible from the Settings menu without a password, this menu allows you to check common tablet issues. Signal Strength: Use to quickly check the cellular and Wi-Fi reception on site in a patients home and move the tablet for optimal signal strength. The signal strength bars increase in real time. 6 2015 Honeywell International All Rights Reserved CP412.01

Status Screen Remote Configuration Instant remote configuration retrieval with one touch: Use to retrieve a remote configuration on site without a password. It is recommended to use this before making changes to the monitor and syncing with LifeStream. The retrieval option will not be available if a cellular or a Wi-Fi connection is not available. The status of the retrieval displays in real time. 7 2015 Honeywell International All Rights Reserved CP412.01

Upgrading to Genesis Touch v3.2 In most cases, you WILL be eligible to upgrade Upgrades do NOT install automatically. You must initiate the software upgrade. Upgrade while on Wi-Fi in the office before deploying Allow about 10-20 minutes for a complete upgrade. Fuze video visit software also downloads during the upgrade Does your monitor have an A1 or A2 start to the serial number? Go here for upgrade instructions: https://resources.hommed.com/genesis- Touch-Upgrade-Site.html The upgrade checks for the latest version Older monitors with A0 are not upgradeable 8 2015 Honeywell International All Rights Reserved CP412.01

Genesis Touch Peripherals and Vital Sign Entry More Peripherals, More Options Wireless Scales Accuro HRS-305 Scale HomMed Scale A&D UC-355 PBT-Ci Pulse Oximetry Nonin Onyx II 9560 sp02 Contec CMS50E Choicemmed Glucometers Entra Health Systems myglucohealth With an H3 Systems Wireless Adapter: Bayer Contour next EZ Bayer Contour J&J One Touch Ultra J&J One Touch Ultra 2 J&J One Touch Ultra Mini Blood Pressure A&D 767PBT-Ci Patient Entered Allow a patient to report vital signs from their own device with guided user interface screens for: Temperature Blood Pressure Blood Oxygen Blood Glucose INR Peak Flow Heart Rate Weight 9 2015 Honeywell International All Rights Reserved CP412.01

Schedule Readings Select General from the Settings screen. 10 2015 Honeywell International All Rights Reserved CP412.01

Schedule Readings Enter the password 4237. Select the Forward icon. 4237 11 2015 Honeywell International All Rights Reserved CP412.01

Scheduling Days and Times of Readings Select Schedule. 12 2015 Honeywell International All Rights Reserved CP412.01

Scheduling Days and Times of Readings You have the ability to set up a schedule for vitals collection. Select the plus sign. A default schedule appears and you have the ability to edit. Check All: Check days: All days are selected Allows daily customization Select Change Time to set the time of day for readings. Touch the days for which you will set up a scheduled time. 13 2015 Honeywell International All Rights Reserved CP412.01

Scheduling Days and Times of Readings Enter time for vitals/ biometric collection. Select: The Edit Schedule screen appears showing changes. Select: 14 2015 Honeywell International All Rights Reserved CP412.01

Scheduling Days and Times of Readings Select the key to add more reading times. Select the key. * You can schedule up to four readings in each 24-hour time period. 15 2015 Honeywell International All Rights Reserved CP412.01

Adding and Pairing Peripherals For each Bluetooth peripheral you will use with this monitor, you must first add the peripheral, then pair it to the monitor. Adding a peripheral is the process by which you enable the Genesis Touch to recognize a specific type of peripheral for input. Pairing is a process in which two Bluetooth devices communicate with each other through an established wireless connection. 16 2015 Honeywell International All Rights Reserved CP412.01

Configuring Peripherals From the General Settings screen, select Peripherals. 17 2015 Honeywell International All Rights Reserved CP412.01

Peripherals Screen Select key to add a peripheral. * If peripherals have already been added to this monitor, they will appear here. 18 2015 Honeywell International All Rights Reserved CP412.01

Peripherals Menu Select the type of peripheral you want to add. 19 2015 Honeywell International All Rights Reserved CP412.01

Peripherals Menu: Adding a Pulse Oximeter To add a pulse oximeter, select the key. Devices already added will appear on this screen. Select Pulse Oximeter. The SP02 unit requires a reading to pair. Setup readings are NOT transmitted to LifeStream. 20 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Pulse Oximeter (SpO2) Device Select Device. Off: Peripheral not engaged. Patient: Results can be manually entered by patient. Device: Results will be captured by Genesis Touch monitor. The Acquisition Schedule area appears: 21 2015 Honeywell International All Rights Reserved CP412.01

Pairing the SP02 Device Place the SP02 unit on a finger, and press the power button on the device. Once the SP02 unit is on and reading, select No Device Paired on the tablet. Power Button Pulse Oximeter *Verify that the device is charged prior to pairing. 22 2015 Honeywell International All Rights Reserved CP412.01

Pairing the SP02 Device During pairing, the following screen appears as the tablet searches for the SP02 device. Touch the box to select the oximeter to pair. * If no devices are found, you can touch the Scan button to rescan for an SPO2 device. 23 2015 Honeywell International All Rights Reserved CP412.01

Pairing the SP02 Device A Bluetooth pairing PIN is required for older monitors or monitors that need upgrading. When prompted, enter 0000 for the SP02, then select OK. * Hint: The password for oxygen is zeros: O2 = 0000 24 2015 Honeywell International All Rights Reserved CP412.01

Pairing the SP02 Device When successful, you will see a check mark in the box along with the name and device number. Select the key. Select the schedule you want. 25 2015 Honeywell International All Rights Reserved CP412.01

Peripherals Menu: Adding a Blood Pressure Unit To add a blood pressure unit, select the key. * Devices already added will appear on this screen. Select Blood Pressure Older BP units require a reading to pair. Setup readings are NOT transmitted to LifeStream. 26 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Blood Pressure Unit Select Device. Select No Device Paired. 27 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Blood Pressure Unit Place the Blood Pressure cuff on your arm. Press Start on the Blood Pressure unit. Once the cuff starts inflating, touch Start Pairing on the tablet. * Verify that batteries are installed prior to pairing. 28 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Blood Pressure Unit If a window appears asking for your permission to continue pairing. Select YES. 29 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Blood Pressure Unit Pairing can take over 2 minutes to complete. When the blood pressure reading is complete, remove the cuff. When pairing is complete, a Pairing Succeeded message appears. 30 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Blood Pressure Unit After pairing select: A check mark appears indicating successful pairing. Select the key. 31 2015 Honeywell International All Rights Reserved CP412.01

Notes on the New UA-767PBT-Ci If you have an A&D Blood Pressure Monitor, UA-767 PBT-Ci (shown below) please follow the new pairing directions in the Getting Started Guide to pair your blood pressure unit with your monitor. If you are unsure of the model, check to see that Ci shown below the Blood Pressure Monitor display, as indicated here: You will need to be using Genesis Touch v3.0 or higher. You no longer need to establish a valid blood pressure reading, or connect the blood pressure cuff in order to pair with the monitor. 32 2015 Honeywell International All Rights Reserved CP412.01

Notes on the New UA-767PBT-Ci After you insert four AA batteries in the blood pressure unit, wait approximately two minutes until you do not see Pr displayed on the blood pressure unit screen. Or, if you plan on pairing the unit to the Genesis Touch immediately, press the round start button on the Blood Pressure unit to bypass this timeout sequence and continue. 1. When you are ready to begin, press and hold the Start button until upr is displayed on the blood pressure monitor. 2. Press Start button while upr is displayed. 3. The Blood Pressure monitor will display END and turn off. You have now prepared your blood pressure monitor for pairing by clearing any previous settings. You are clear to begin pairing. 4. If err10 or err11 is displayed, try steps 1-3 again. More information is available in the Genesis Touch Getting Started Guide. 33 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Scale Select Device. The Acquisition Schedule area appears. Select No Device paired. 34 2015 Honeywell International All Rights Reserved CP412.01

Pairing the Scale Monitor is searching. All powered Bluetooth scales in range appear. Find the correct serial number for the scale you want to pair and touch the box to select. * If no scales are found on the initial scan, you can use the Scan button to search again. 35 2015 Honeywell International All Rights Reserved CP412.01

Pairing the H3 Systems Adapter 1. Press the Settings button on the Genesis Touch: 2. From the Settings Window, select General Settings: 3. Type password 4237 and tap the forward button: 4. From the General Settings window select Peripherals: 5. From the Peripherals window, tap the Plus Sign: 6. From the Select Peripheral window, tap Glucometer: 7. From the Glucometer window, tap the Device button: 36 2015 Honeywell International All Rights Reserved CP412.01

Pairing the H3 Systems Glucose Adapter 1. With your H3 Adapter in front of you and near the Genesis Touch, hold down the red button on the front of the adapter for 5 seconds. 2. You will see a solid red light turn on: 5 sec. 3. Wait 5 seconds and tap the No Device Paired box to pair: 4. You will see a spinning circle as the Genesis Touch looks for the Adapter. You will see the following when the adapter has been located: 5. Tap the red box to pair the device. You will see the following screen when complete: Tip: Wait a few seconds after the red light has appeared on the H3 adapter. Press the scan button if you need more time to search for the adapter: 37 2015 Honeywell International All Rights Reserved CP412.01

Patient Entered Peripherals All Peripherals have the option of Patient entered. The Thermometer only has the Patient option. Select Patient mode Then set the Schedule. No pairing is required. The Tablet is now configured for the patient to manually enter their temperature. This process is the same for all Patient entered options. 38 2015 Honeywell International All Rights Reserved CP412.01

Enable/Disable Spoken Vitals From the Settings Screen select Device. Touch Spoken Vitals. A check mark indicates that spoken vitals is enabled. No check mark indicates that spoken vitals is not enabled. Select the side. key which may be at the bottom or on the 39 2015 Honeywell International All Rights Reserved CP412.01

Installing in the patient home Now the easy part ; Installing the monitor in the patient home. Once you have all the equipment paired, installation involves: Setting up the monitor in an accessible location, Making sure the scale is on a firm surface within 30 feet of the monitor Verify cellular or Wi-Fi connectivity from the Status Screen. The monitor will need to remain connected to electricity. The Oximeter does NOT need to stay connected. Once fully charged after 4-5 hours, you may disconnect this peripheral. Recharge if needed. The blue light indicates the oximeter is completely charged while plugged in. The light turns off when unplugged. 40 2015 Honeywell International All Rights Reserved CP412.01

Installing in the patient home (Cont.) Have the patient do a complete set of vitals so they can experience everything including touching Vitals Now to get started. Have the monitor in a quiet area away from distractions or loud noises Have the patient answer questions using the Yes/No keys Explain concept of more today than a normal day. Proper SpO2 placement; warm hands; Wear O2 or not? Proper BP cuff placement; hose is over the artery, no talking, bare arm or light clothing Wait for the scale to prompt stepping on the scale stand still until prompted to step off. Call your LifeStream clinician to verify the Vitals were received. Review the patient instructions and collect signatures as identified by your company. 41 2015 Honeywell International All Rights Reserved CP412.01

Troubleshooting Don't hesitate to call. We're here for you 24/7 There is no charge for calling Technical Support Many problems can be resolved during the call. Call 1-888-353-5404 and Dial 1 for Technical Support Tips When Calling.. Call when you first sense that you may be spinning your wheels. Be Prepared. We re probably going to ask for the serial number of the monitor and/or the peripheral that is misbehaving. We may ask you to do something you ve already tried (like turn it off and back on.) Sometimes we need to get the equipment back to a known starting point to troubleshoot most efficiently. It is very likely we have seen your issue before and know how to approach a problem you might run into. 42 2015 Honeywell International All Rights Reserved CP412.01

Questions I have older peripherals and I need to order a new Genesis Touch. Are those old peripherals compatible? Yes, the Genesis Touch is backward compatible with older Honeywell-approved patient monitoring peripherals. The pairing procedure may be different however. If you are using an older A&D blood pressure cuff, you have to take a valid reading in order to pair it. The newer A&D blood pressure cuff will pair even with no cuff attached. What is in a Glucometer kit? You may order either a Bayer or J&J Wireless Glucometer Kit from your sales representative. A kit includes a Bluetooth adapter, a folded card of patient instructions and a card that links you to a website to access installation information. Order the glucometer from the glucometer manufacturer (preferably all from the same source), and test the glucometer on a Genesis Touch pairs successfully prior to deploying. Purchase two AAA batteries per glucometer adapter. It is recommended to use a highcapacity battery type. Always change batteries before redeploying. 43 2015 Honeywell International All Rights Reserved CP412.01

Questions Which cellular provider works with the Genesis Touch? Verizon Wireless provides cellular service if a Wi-Fi service cannot be used at the monitoring site. If using video it is preferred to purchase an expanded cellular data plan from Honeywell due to improved quality and reliability this can provide. Go to our Customer Service website for a link to a Verizon cellular coverage map: https://www.honeywelllifecare.com/customer-service/ How far can peripherals be placed from the Monitor? Up to 30 feet away as long as there aren t walls or other things in between the monitor and the peripheral. Consider the patients ability to get to the peripherals and place in a convenient place, with all peripherals near the monitor. Since the monitor screen remains lit as a clock, it is preferred to place the monitor wherever a patient may check the time frequently, such as the kitchen table. I ve disconnected the Contec oximeter as indicated, but how long should I expect the battery to last? According to the manufacturer, a charged battery will last up to about 300 readings when fully charged, or for approximately 10-months of daily readings. Leaving the oximeter plugged in and charging may harm the battery life. 44 2015 Honeywell International All Rights Reserved CP412.01

Additional Information Be aware that Bluetooth pairing can be lost on the new A&D Blood Pressure monitor (UA-767 PBT-Ci) if the patient holds the button too long (about 5 seconds), or it is inadvertently pressed during transit. Other than approved Honeywell peripherals, it is not recommended to have many Bluetooth devices in one room. Un-pair all new A&D devices before pairing for deployment. If the tablet has been on the shelf for a while, test the communications before taking it to the patient s home. If it doesn't transmit, contact Tech Support with the serial number of the tablet for a reset of settings on the Verizon network. If one of the volume buttons is inadvertently held down when powering up, the monitor will go into a System Recovery or Boot screen. Follow the on screen instructions to either restart or cancel or call Tech Support. This is most likely to happen if you use an external case on the tablet. If the monitor gets through the boot process, but does not automatically launch the Genesis Touch application, try restarting the monitor. If unsuccessful, call Tech Support 45 2015 Honeywell International All Rights Reserved CP412.01

Wrap up Questions? Genesis Touch Upgrades Must initiate the upgrade. Upgrade available on A1, A2 units. Go to Settings > About to check current monitor version Make sure the Genesis Touch is connected to a Wi-Fi network before upgrading. You will be notified via email of any Genesis Touch monitoring software updates. Resources: The Honeywell website has all the resources we have referenced, including these slides: https://www.honeywelllifecare.com/lifestreamservices/clinical-support/ If you have not registered, do so today as this is only available to our current customers The Genesis Touch manuals, guides and videos are all available at the website Contact your clinical consultant for more info. Customer Service 1-888-353-5404 Webinar Registration: https://resources.hommed.com/lifestreamuniversitysignup.html 46 2015 Honeywell International All Rights Reserved CP412.01

Appendix Additional information about Genesis Touch v3.2 47 2015 Honeywell International All Rights Reserved CP412.01

Genesis Touch Telemonitor v3.2 Tablet Enhancements The latest in device technology includes a larger screen, better video quality, and faster operating speeds to improve data transmissions times. Monitor size increase from 7 to 8 Front-facing 1.3 megapixel camera Double the processing power and more internal memory Status screen enables a patient to immediately install an updated configuration if requested by the clinician, and displays 4G radio reception for installers to troubleshoot technical issues. Education Simplified education improves patient comprehension, and clarifies when a response is required during the monitoring process. Improved suggested health tips Simplified language to a 6 th -grade reading level Addition of glucose education to a vitals acquisition Language Support Canadian-French language support, in addition to existing Spanish and English options, reduces the effect of language barriers across a diverse population. 48 2015 Honeywell International All Rights Reserved CP412.01

Genesis Touch Telemonitor v3.2 Expanded Disease Management Protocols Diabetes management tools provide clinicians with more efficient workflows for monitoring their diabetic population and drive compliance with care plans, while enabling individuals to more easily control their illness. Automatically send glucose readings to the Genesis Touch through wireless connectivity to the most widely used glucometer brands. Readings may now also be entered manually. Bayer Johnson & Johnson Entra Health Systems myglucohealth Diabetes-specific education and question sets assists clinicians with evaluating their patients health and helps individuals better understand their diagnosis. Collect Additional Biometrics Collect an expanded range of biometric data for a more complete view of patient health. Peak Flow Blood Glucose and INR have now been added with manual entry; Wireless Bluetooth Blood Glucose vital signs entry has also been added. This is in addition to: Blood Oxygen; Heart Rate; Temperature; Weight, Blood Pressure An additional scale, the A&D UC-355PBT-Ci, features automatic on/off, a wider surface area for stability and a 550lb limit. 49 2015 Honeywell International All Rights Reserved CP412.01

Wireless Glucometers Device Bayer Contour next EZ Bayer Contour J&J One Touch Ultra, Ultra 2, Ultra Mini Entra Health Systems MyGlucoHealth Key Features No set-up No coding needed Easy-to-read display Evaluates sample multiple times Identify trouble spots with HI/LO target range 7-, 14- and 30-day averages Affordable, commonly used meter No set-up, 5-sec test time Identify trouble spots HI/LO target range Pre-meal and post-meal markers Eliminate inaccurate test results 7-, 14- and 30-day averages Large screen with back light to read results day or night Add meal flags to link the effects of food on results 7, 14, and 30-day averages to see your trends. Large memory and download port Short 3 second test Smallest blood sample size (0.3mL) Automatic coding of test strips Extensive Support 2000 test battery life Easy to pair and transmit Glucometer Adapters Order the Bayer H3 Adapter Kit from Honeywell Order the J&J H3 Adapter Kit from Honeywell All Glucometers must be ordered from the manufacturer or a retailer. Glucometer Order the current version of the glucometer from the manufacturer or retailer: https://www.bayerdiabetesstore.com/ Order the current version of the glucometer from the manufacturer or retailer: http://www.onetouch.com/ Order directly from Entra Health Systems at: http://store.myhealthpoint.co m/collections/my-gluco-health 50 2015 Honeywell International All Rights Reserved CP412.01

A&D Scales A&D 321PBT (click to go to A&D scale page) Press blue button to turn on, automatic off. Order from Honeywell 450 lb weight capacity 12.3 x12.6 x1.4 Includes four attachable feet for carpet use, optional carpet tray through A&D. A&D 355PBT-Ci (click to go to A&D scale page) Step on instant on, automatic off. Order from A&D: http://www.andonline.com/ 550lb weight capacity 14 x16.4 x1.5 larger size Comes with carpet tray Displays measurement in 10ths while the Genesis Touch displays full/half units. 51 2015 Honeywell International All Rights Reserved CP412.01