ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

Similar documents
ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

ErP OPERATIONS MANUAL FOR СOMMERCIAL CURTAINS PROTON HEAT DOOR C2. Safety precautions Construction and dimensions Technical parameters Installation

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Technical documentation

A tool for professionals.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation DTR

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

USER S MANUAL. VKP Series INLINE FAN

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

MANUAL Air curtain WRM06+ WRM08+ WRM10+ WRM12+

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Series VENTS VUT R WH ЕС

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

LONGONI ENGINEERING SRL

Gas heaters and convectors ROBUR

Centrifugal inline fans

Technical documentation: S1 S2 S3 S4

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Thermal Devices, Inc. Mount Airy, Maryland USA

HI Industrial Utility Heater HI Soleus Air International

BLAST FREEZING ROOMS

Air curtain.

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AXIAL FANS USER S MANUAL

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Industrial Air Heaters

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Main technical datas:

TEVHR. Heat Recovery Ventilator

HEAT RECOVERY VENTILATOR

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

Technology for life. Unit heater LH

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

TopVent Design Handbook

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

ATM Lighting sp. z o.o

ATFLASH. Sensor ATFLASH SENSOR USER GUIDE ATFLASH. Sensor ATFLASH SENSOR USER GUIDE

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

USER'S MANUAL PS

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

VERSO Air Handling Units

40E ELECTRIC FAN HEATER

DanVex AD-200 Adsorption air dehumidifier. Operation manual

VERSO Air Handling Units

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE ELECTRONIC CONTROL

18E ELECTRIC FAN HEATER

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Powrmatic PZN / PZN X Hot Water Heater

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Manual for Ceiling Patio Heater

TTV 4500 / TTV 4500 HP / TTV 7000

DURANGO 12V Heater HF

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Electric Space Heater

Operating Instructions Air Conditioner

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Air handling unit. BlauAir RH USER S MANUAL

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

USER S MANUAL DN-2. Drain pump

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

tungsten Smart-heat electric heater

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

INSTRUCTION MANUAL FOR ROVA-2L/3L ROTARY EVAPORATORS PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Wall Mounted Split Systems

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Transcription:

OPERATIONS MANUAL FOR AIR HEATER PROTON EL ErP 2015 05010416 05022916 PROTON EL Electric heating Safety precautions Construction and dimensions Technical parameters Installation EN RU www.protongroup.org

CONTENTS Operations manual for air heater with electric heating PROTON EL: 1. Introduction... 3. 2. Safety precautions... 4 3. General information... 5 4. Technical characteristics... 6 5. Construction... 7 6. Mounting console... 8 7. Installation... 10 8. Control elements... 11 9. Wiring control elements... 13 10. Reference information... 14 2

1. INTRODUCTION The company PROTON GROUP LLC thanks you for choosing air heaters PROTON. This manual is an integral part of the product and must always accompany it, and should be transferred to the user. To provide proper wiring and application of the unit, please, study this manual thoroughly before installation. We recommend keeping the manual safe in order to address it during operation. The user should strictly follow safety instructions while installing, using and servicing the unit. The access to the unit must be restricted for unauthorized and unqualified personnel. The appropriate training of the maintenance staff should be provided. The manufacturer disclaims any responsibility for damages caused by wrong installation and misuse of the unit. The manufacturer disclaims any responsibility for damages done by people who didn t study the manual. The manufacturer preserves the right to introduce any amendments to the manual without prior notification. The manufacturer preserves the right to alter the construction which doesn t impact its functioning and basic technical parameters. The air heater is intended only and exclusively to be installed and used for purposes which it has been designed. Any misuse or noncompliance with the manufacturer s instructions may lead to property damages, personnel injuries or death. The user has to take measures to eliminate possibilities of misuse of the unit. 3

2. SAFETY PRECAUTIONS Before any actions connected with the air heater, please, study this manual to provide safety. Installation and connection of the equipment to networks must be performed by qualified personnel only, having appropriate access. During installation, start-up, repair and maintenance of the air heater follow the safety rules. Install the unit on a firm base or surface, which can stand its weight. Contacts of a temperature sensor of a fan and protection of the air heater must be connected to a control board and a thermal protection relay for emergency shutdown of power network feeding finned electric heating elements. The electric power network feeding the air heater and control elements must have extra protection against phase failure. Check compliance of parameters of the electrical supply network to the ones indicated on the unit s rating plate before connecting to the power supply. Check grounding. Prohibit the use of the unit without grounding as it may cause property damages, personnel injuries and death. It is forbidden to use the air heater with closed louvers. Ingress of foreign particles and liquids into the unit is forbidden. 4

3. GENERAL INFORMATION ErP 2015 PROTON EL It is an air heater with electrical heating. Usage of PROTON EL is extremely effective in the conditions of no-access to the hot water supply. These models are equipped with the ribbed T(ubular) E(lectric) H(eater)s made of high-alloy stainless steel which ensure high intensity of heat exchange and long-lasting trouble-free work of equipment. Model range PROTON EL 15 heating power 7.5/15 kw PROTON EL 30 heating power 11/19/30 kw Principle of operation The air heaters with IP54 protection are available, which are designed to heat moisture environments (car washes, swimming pools). Applications Warehouses and hangars Production facilities Logistics centers Wholesale and retail premises Parking places Car service centers Sports facilities Airports Car washes Winter gardens and green houses Buildings of worship The unit PROTON EL with electric heating is an element of a heating system. It is designed for heating air and its even distribution in buildings. Its work is based on axial fan functioning, which charges the air and pass it through finned tubular electric heaters. Heated air is supplied into a room and is directed to the working area by directing louvers. 5

4. TECHNICAL CHARACTERISTICS Model range Heating power range TEHs мax. temperature TEHs supply voltage TEHs protection class Max. warm air throw Weight Motor power supply parameters Motor power Nominal current of air heate Noise level kw V/Hz IP m kg V/Hz W А db EL 15 EL 30 Airflow m³/h 5600 6100 Air temperature increase С Number of TEHs pcs Motor protection rating IP 54 54 1 2 2 EL 15 i or EL 30 i. Measurements made at distance of 5 m from the unit. С 7.5/15.0 11.0/19.0/30.0 4.0/8.0 5.4/9.3/14.7 6 150 400/50 400/50 25 34.7 1 230/50 230/50 320 420 24.0 46.0 53 57 9 150 21/54 21/54 29 44.6 1 Dimensions of the air heater PROTON EL 700 580 190 680 150 680 400 6

5. CONSTRUCTION Major components of the air heater PROTON EL Casing The casing consists of metal components dyed by powder paint, galvanized fasteners and structural components. Fan The fan is fixed in a special diffuser on the back of the unit, thanks to which air flow is evenly distributed on the finned tubular electric heaters surface. This provides its most effective application. This solution decreases noise level created by the flowing air. The fan is equipped with a special small grill which protects the heater from falling in of debris, leaves etc. as well as prevents possible personnel injures or death caused by rotating fan s blades. Rated power supply of PROTON EL fans is 230 V/50 Hz. Motor protection grade is IP54. Operating temperature range is from -40 C to +50 C. Finned tubular electric heaters Heating elements are made of high-alloy stainless steel. For better heat extraction, toroid-like coils with width of 10 mm with additional corrugation are added to the heating elements. The frame for mounting elements is made of galvanized steel. Joint boxes are equipped with clamping cables with IP54 protection. Thermal sensors of overheat protection of the finned tubular electric heaters are fastened on their top and bottom sides. Directing louvers They are made of steel and dyed by special paint, and provide minimal air resistance at the outlet from the air heater. Aesthetic look and high protection from corrosion guarantee durability and safety. 7

6. MOUNTING CONSOLE Installation on a mounting console CM 3D Order of installation 6 А М8х16 2 4 3 М8х16 4 3 М8х16 5 1 4 3 B М8х16 4 3 М8х16 М8х16 6 1. Fasten brackets 1 and 2 on the air heater s body using screws 3 and rings 4. Follow the brackets position A, B. 2. Fasten the console under necessary angle (position 5 ) using anchoring screws (are to be bought separately). 3. Install the air heater on the console in the position 1 into the hole on the console (position 4 ). Then putting together holes on the bracket 2 and upper hole on the console 5, fix everything by screws 6. 4. Mount the air heater under necessary angle and fix by screws 6. Attention! Use screws M8x16 to fix the console to the body of the air heater. Noncompliance with this recommendation may cause deformation of the inside elements of the air heater. 8

6. MOUNTING CONSOLE Fastening dimensions of the mounting console CM 3D 9 120 476 30 12 90 670 90 45 Ways of installation with mounting console CM 3D 30 45 On a wall vertically or horizontally, and under angle of 30 or 45. On a wall with bend to the right or left under angle 0 to 90. 90 90 Attention! The air heaters PROTON EL must be installed vertically only. Noncompliance with the minimal distance (0,25 m) from a wall or ceiling will lead to wrong operation of the air heater which, in turn, will influence the useful life of the equipment. 9

7. INSTALLATION Wall mounting Installation on mounting console Distance from a wall, min. Mounting height Distance of air stream 0,25 m 3-8 m up to 29 m 3-8 m 29 m* * directing louvers are installed under angle of 45 The air heaters PROTON EL must be installed vertically only. Recommended distances from walls and ceiling Recommendations of placing units min 0,5 m min 0,25 m Noncompliance with the minimal distance (0,25 m) from a wall or ceiling will lead to wrong operation of the air heater which, in turn, will influence the useful life of the equipment. Examples of placing the equipment which provide even distribution of heat in a building are presented on the illustrations. 10

8. CONTROL ELEMENTS ECOMATIC PRO ECOMATIC PRO is a control element with help of which advantages of heating and ventilation systems become more noticeable and perceivable as its use provide comfortable inside temperature and significant energy savings due to fast response of the system to changes of climatic conditions in a room. Using PROTON PRO you increase equipment lifetime protecting it from functioning under alarm mode. DEL 550 Control board Protection devices and controls must be always applied for proper use of equipment powered by electric network. The control board DEL 550 has been developed ad hoc for the electric heater EL with single-phase three-speed AC-motor and programmable controller RTS 30. Using this equipment the following options are available: programming by week mode 5+1+1; setting certain temperatures by day/night; connection of the groups of finned tubular electric heaters (finned TEHs) depending on temperature (automatic mode); choice of fan speed (manual mode). For convenient running, the board has operation and alarm light indicators. The control board is placed in plastic casing with IP54 protection and has a transparent door with additional gasket. You can see signals of operating/alarm statuses through the door that increases ease of use. Provides control over Single-phase three-speed AC-motor. Finned TEHs: PROTON EL 15 2х7,5 kw; PROTON EL 30 1х11 kw, 1х19 kw. Control signals RTS 30 Programmable сontroller (is in set with the control board DEL 550). Fire-protection alarm dry contact. Thermal protection of finned TEHs. Thermal protection motor. External thermal sensor NTC 65 (is in set with control board DEL 550). More information about ECOMATIC PRO you can receive on demand. 11

8. CONTROL ELEMENTS RTS 30 Programmable сontroller (is in set with the control board DEL 550) RTS 30 is a programmable controller of temperature and fan s rotation speed. Programmable temperature mode with accuracy of up to 0,5 C. Automatic or manual mode of control over fan revolution speed. Week programmability by day/night, working days (days off). Remote controller RC 30 (option). Connection of temperature sensor(-s) NTC 65 (option). High level of energy savings. Reduction of the noise level NTC 65 External thermal sensor (is in set with the control board DEL 550) The sensor is designed to fix temperature in a room and transfer data to a controller. The sensors have IP65 construction, that allows to apply them in industrial buildings (dusty, moist, explosive environments). High accuracy. Ability to connect a group of large buildings. Ability to use in explosive buildings. More information about ECOMATIC PRO you can receive on demand. 12

9. WIRING CONTROL ELEMENTS 1 2 TP TP 1.1 1.2 L 1 L 2 L 3 PE L 1 L 2 L 3 PE PE LO ME HI N DEL 550 3 X1 X2 PE L1 L2 L3 N 2 4 6 2 4 6 6 4 2 PE PEPE N 1 2 3 4 7 8 9 101112131415 K2M K3M K1M 4 PE L 1 L 2 L 3 N 3~400 V/50 Hz «Dry contact» of 5 6 fire-proof main DC NTC 65 10 11 NTC 65 8 7 1 2 3 4 5 6 7 8 9 Key to the diagram 1 2 3 4 5 6 7 8 junction box of a group of finned TEHs of the unit junction box of a fan control board DEL 550 power supply (distributor or main switch) 3~400 V/50 Нz «dry contact» of fire protection remote switching on/off RTS 30 programmable controller (is in set with the control board DEL 550) External thermal sensor NTC 65 (is in set with the control board DEL 550) 13 Notes RTS 30 The use of regulators of fan rotation speed is strictly prohibited.

10. REFERENCE INFORMATION Table of pressure calculation on a wire depending on its section Material of the conductor copper: Section of current conducting core, mm 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 2 Material of the conductor copper Voltage, 220 V Voltage, 380 V Current, A Power, kw Current, A Power, kw 19.0 4.1 16.0 10.5 27.0 5.9 25.0 16.5 38.0 8.3 30.0 19.8 46.0 10.1 40.0 26.4 70.0 15.4 50.0 33.0 85.0 18.7 75.0 49.5 115.0 25.3 90.0 59.4 135.0 29.7 115.0 75.9 175.0 38.5 145.0 95.7 215.0 47.3 180.0 118.8 260.0 57.2 220.0 145.2 300.0 66.0 260.0 171.6 Material of the conductor aluminum: Section of current conducting core, mm 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 2 20.0 28.0 36.0 50.0 60.0 85.0 100.0 135.0 165.0 200.0 230.0 Material of the conductor aluminum Voltage, 220 V 4.4 6.1 7.9 11.0 13.2 18.7 22.0 29.7 36.3 44.0 50.6 19.0 23.0 30.0 39.0 55.0 70.0 85.0 110.0 140.0 170.0 200.0 Voltage, 380 V Current, A Power, kw Current, A Power, kw 11.6 15.1 19.8 25.7 36.3 46.2 56.1 72.6 92.4 112.2 132.0 Data is presented as a reference. For calculations for actual projects address to specialists. 14

FOR NOTES 15

Service department In case of any failures in operation of equipment address the authorized support centers of the Manufacturer. For information about support centers and procedure of claim submission contact Manufacturer s service department: PROTON GROUP LLC 03680, Ukraine, Kyiv, 3, Nesterova str. Tel.: +380 (44) 537 0930 Fax: +380 (44) 537 0903 E-mail: service@proton.kiev.ua www.protongroup.org www.protongroup.org