PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

Similar documents
FLASH PAK STERILIZATION CONTAINER SYSTEM

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

Lower Your Costs. Expand Your Flexibility.

Lower Your Costs. Expand Your Flexibility.

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

The Principles, The Process, and The Results:

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Sterling P1500 Washer-Disinf ec t or Acce s s or y Guide

Ultrasonic From delicate microsurgery instruments to heavy duty sets

STERITITE INSTRUCTIONS FOR USE

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Instrument Cleaning Chemistries Automated Washing Process

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

In 2011 JCAHO in standard E.C.6.20; states that all medical equipment is maintained, tested and inspected (2).

Cleaning Verification

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Getinge WD14 Tablo Tabletop washer-disinfector

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

Cleaning and Sterilisation for Burs, accessories and filling material

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

STERIS Instrument Cleaning Chemistries

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

X99 Series. Dental Handpiece. Instruction For Use

Washer Test Kits User Guide

ProFormanceTM Cleaning Verification Products

RANGE STUDY COURSE UNDERSTANDING RANGE: MECHANICAL COMPONENTS. Module 3 LIT Rev. C

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

Getinge 600 series Top-loaded flusher-disinfectors

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Operation Manual NEMA 4X Controls

Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)

PREFERENCE ICC. A Complete System For Efficient Sterilization

Repair Parts List DISHWASHER MODEL NUMBER MDB6100AWW. When requesting service or ordering parts, always provide the following information:

Model: DEDW97FI. Dishwasher details. Read this guide carefully, it is intended to help you operate and maintain your new Dishwasher properly.

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

CLEANING INSTRUCTIONS

Cleaning and Sterilization for Instruments & Posts

THE BASICS OF DECONTAMINATION

AMITY INTERNATIONAL (U.K.)

GETTING STARTED? EASY.

Repair Parts List DISHWASHER MODEL NUMBER MDB4000AWB. When requesting service or ordering parts, always provide the following information:

Repair Parts List DISHWASHER MODEL NUMBER MDB7100AWW. When requesting service or ordering parts, always provide the following information:

MODEL CMA-130VL PARTS MANUAL Rev 1.00

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Washer disinfectors Small - Medium range

PROBLEM CAUSE CORRECTIVE ACTION. Product Service Replace cup. Malfunction of cup. Detergent cup fails to open. Malfunction of relay

Best practices in Cleaning and Safety

Cleaning & Sterilization

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

CLEANING. 3. Clean off the dish tables into the dishwasher. 4. Drain the machine by lifting up the drain lever.

IQ/OQ Protocol Installation Qualification/ Operation Qualification

AUTOMATIC BEDPAN AND URINAL WASHERS MODEL LP/IN90-S/D.T.A SELF-PRODUCED STEAM DISINFECTION

PRO 2000i LOW LEVEL DEPOSITOR

Developing the Solutions For You. Veterinary 2018 VETERINARY PRODUCT CATALOG

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

SKY Stainless Steel Compact Dishwasher. Instructions

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

equipment & tools Professional Cleaning Solutions ProBlendCommercial.com

GETTING STARTED? EASY.

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Flusher disinfectors for hospitals and nursing houses

UW50 UTENSIL/PAN WASHER

The Reliance 400/500 Glassware Washers

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

2015 Myco Industries, Inc Fax:

One Operator Bottling.

Classification of Instruments -

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

STANDARD OPERATING PROCEDURES

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

SERVICE MANUAL DISHWASHERS

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

Operating / User Manual

The future is bright. And clean. And fully automated.

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

Food & Beverage STEWARDING MANUAL CHIEFS MANUAL & SOP S

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

HOT WASHER MODEL NO: KING150

FAVORIT DISHWASHER USER MANUAL

GETTING STARTED? EASY.

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

LABORATORY GLASSWARE WASHER MACHINE

Transcription:

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS Instructions For Use Overview MKT 15-10AECIFU Rev 4/15 1

PURPOSE OF THE PINNACLE AEC TEST The test is to be used to monitor the effectiveness of the washer-disinfector s instrument cleaning cycle when using enzymatic detergent. This test strip is also used to monitor instrument cleaning of ultrasonic cleaners when using enzymatic detergent. Recommended use: Weekly preferably daily The test has not been found to react to wash cycle additives such as rinse aids or lubricants (based on Serim Research testing and commercial use). 2

Do not use the PINNACLE AEC Test for: testing bedpan or cart washers using lower detergent concentrations and/or shorter cycle times plastic ware wash cycles using low temperature settings and/or shorter wash cycles wash cycles using neutral detergents NOT containing enzymes 3

FACTORS INVOLVED IN MECHANICAL CLEANING A large portion of the cleaning action is dependent on the detergent chemistry used. When using neutral enzymatic detergents exposure time as well as the wash temperature plays an important role in the action of the active enzyme on the contaminating soils. 4

HOW TO USE THE PINNACLE AEC TEST Remove a test strip Write date/time, washer ID from bottle and location on strip Insert the strip in a holder 5

HOW TO USE THE PINNACLE AEC TEST Preparation of test - Remove as many Pinnacle AEC test strips from bottle as needed - Write date/time, washer ID and location on strip - Test devices should be used within 8 hours of preparation - Insert test strip in the holder Slide ends of the Pinnacle AEC test strip between the crimped tabs on each end Place the Pinnacle AEC test strip in the channel of the resin holder and snap closed 6

HOW TO USE THE PINNACLE AEC TEST Test Device Components: - Test Strip containing the Indicator Pad and the Internal Color Standard. - Comparison of Indicator color with Internal Standard color determines PASS or FAIL condition - Test Strip Holder with hook to secure test device onto racks or baskets in washer and ultrasonic cleaner. 7

HOW TO USE THE PINNACLE AEC TEST Placement in Washer / Disinfector Test Device has to hang freely, without being obstructed In Baskets Use the hook to attach the PINNACLE test device to the handles or wire openings of baskets Place baskets on middle and bottom rack rack In rare instances, when clogged nozzles or spray arms resulted in increased water pressure from the main spray arm, the indicator pad on a test device placed directly under the main spray arm was removed by the force of water. 8

HOW TO USE THE PINNACLE AEC TEST Placement in Washer / Disinfector Test Device has to hang freely, without being obstructed On Racks Hook the test around the perimeter of the rack, do not obstruct the spray arm movement away from spray arm 9

PROPER PLACEMENT OF PINNACLE AEC TEST DURING USE Incorrect Placement in Washer-Disinfector Test is obstructed 10

PROPER PLACEMENT OF PINNACLE AEC TEST IN ULTRASONIC CLEANERS Hang test around perimeter or place flat in the basket for ultrasonic cleaners do not obstruct test 11

READING THE PINNACLE AEC TEST RESULTS Interpretation of Results: - Remove strip from Holder, ensure that you hold strip PAD SIDE UP! - Interpret the results by comparing the color of the LARGER indicator pad to the smaller internal color standard. PASS: Indicator Pad is lighter than color standard FAIL: Indicator Pad is similar or darker than the color standard 12

Please visit the Central Service Support page on www.serim.com for reference and support material including Reference Guide, Log Sheet and Instructions for Use Diagnosing a Fail test result presentation is also available on the Central Service Support Page Information about the PINNACLE Manual Enzymatic Cleaning Process (MEC) test and other products can be found at www.serim.com 13