ORENA BRAND CONVENTIONAL (ORENA Brand) CE

Similar documents
PSN-1000 & PSN 1000(E) Installation Manual

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

30.45 Electric Release PDRP-2001

TECHNICAL DATA OBSOLETE

Addressable Fire Alarm Control Panel

FA-101U Fire Alarm Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

good things in small packages

Conventional Fire Alarm System Product Range Guide

Intelligent addressable fire alarm control panel

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Multiple Input and Output Modules

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AND ARCHITECT SPECIFICATIONS

MPC-6000 / MPC-7000 / RND-2

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Agent Release Control Panel

Installation, Operating and Maintenance Manual

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

FireNET Plus Wiring Instructions

SECTION FIRE ALARM SYSTEMS

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Excel-EN Conventional Fire Control Panel

Signature Series Auto-Sync Output Module (CC1S)

Conventional Fire Alarm Systems

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

io64 Intelligent Life Safety System

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

IGD.CO.UK

DS7400Xi Addressable Control/ Communicator

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

AL800ULADA. NAC Power Extender. Installation Guide

Model 17A00 Expansion Enclosure

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

intelligent solutions

Remote NAC Power Supply D7038

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

AL600ULADA. NAC Power Extender. Installation Guide

Addressable and Conventional Fire Protection

Solution F2. Fire Alarm Control Panels one step ahead.

Conventional Releasing Control Panel

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

ELECTRONIC SOUNDER STROBE Model : AVD-C407

AND ARCHITECT SPECIFICATIONS

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MR-2602 Two Zone Fire Alarm Control Panel

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Multiplex Eight Input Remote Modules

Touch Screen 1 loop Addressable Fire Alarm Panel

Fire Product Catalog

ACP10 & ACP50 Security Systems

Commercial and Light Industrial Fire Alarm Control Panel

Specification/ Data Sheet

Intelligent Single Loop Fire Alarm Control Panel

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

LifeAlarm Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Electric Release Panel Wiring Tips

System 800 Addressable Fire Detection & Alarm System

Vista-128FB System Design Sheet

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Wireless Fire & Security Solutions. Fire Product Showcase

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

INTELLIGENT FIRE ALARM CONTROL PANEL

5000 INSTALLATION GUIDE

Battery charger modules

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

QS1 Intelligent single loop life safety control panel

The complete conventional fire warning system

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

Vista-10SE System Design Sheet

The ACM-8R Annunciator Control Module

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Transcription:

ORENA BRAND CONVENTIONAL (ORENA Brand) CE ODH02E 2 Zone Conventional Control Panel Zone Capacity: can be connected with 20 fire detectors and infinite manual call points Using environment: Temperature: 0 C~50 C Related Humidity: 95% (40±2 C) Dimensions: 370mmx240mmx60mm ODH04E 4Zone Conventional Control Panel Zone Capacity: can be connected with 20 fire detectors and infinite manual call points Using environment: Temperature: 0 C~50 C Related Humidity: 95% (40±2 C) Dimensions: 370mmx240mmx60mm ODH08E 8 Zone Conventional Control Panel Zone Capacity: can be connected with 30 fire detectors and infinite manual call points Using environment: Temperature: 0 C~50 C Related Humidity: 95% (40±2 C) Dimensions: 265 335 87mm (length width depth ODH16E 16 Zone Conventional Control Panel Zone Capacity: can be connected with 30 fire detectors and infinite manual call points

Using environment: Temperature: 0 C~50 C Related Humidity: 95% (40±2 C) Dimensions: 265 335 87mm (length width depth OT302 Conventional Smoke Detector Operating Voltage: DC20V~DC28V Standby current: 70μ A Alarm current: 20mA (connect to DC24V and 1k resistor in series) Dimensions: Diameter 100mm Height 51mm (with base) Weight: 142g (with base) OT303 Conventional Heat Detector Operating Voltage: DC20V~DC28V Standby current: 70μ A Alarm current: 20mA (connect to DC24V and 1k resistor in series) Dimensions: Diameter 100mm Height 51mm (with base) Weight: 142g (with base) OT303 Conventional Heat Detector J-SJP-M-1 Manual Call Point Operating Voltage: DC24V / AC220V Standby Current: 0 ma Maxim Current: 5 A Contactor Capacity: DC24V/1A Contactor Resistance: 0.1 ohm Operating Environment: Temperature: 10 C~+50 C Related Humidity: 95% (40±2 C) Conventional Sounder Strobe H-SGB ORENA BRAND ADDRESSABLE Particulars (ORENA Brand) CE OZH100 ( Addressable Fire Alarm Control Panel ) 1 loop 252 address points w/o battery Primary Power Supply: 120V or 220VAC 50/60Hz Standby Batteries: DC24V 2.2AH sealed rechargeable batteries Power Supply Output: 24VDC @ 3.0 Amps (2.5 Amps available for system power) Display: 4 lines x 22 characters LCD (88 characters total) LC loops: class A, "style 6 or 7" or class B, "style 4" Devices per loop: 252 sensors & modules&call points Operation Temperature: 10 C~+50 C Related Humidity: 95% (40±2 C) Dimensions (D * W * H): 60 370 240mm Weight: 3.5Kg

OZH4800E ( Addressable Fire Alarm Control Panel ) 4 loop 768 address points w/o battery Primary Power Supply: 120V or 220VAC 50/60Hz Standby Batteries: DC24V 4AH sealed rechargeable batteries Power Supply Output: 24VDC @ 5.0 Amps (4 Amps available for system power) Display: 15 lines x 40 characters LCD (600 characters total) SLC loops: 2, 4, 6 or 8 (class A, "style 6 or 7" or class B, "style 4") Devices per loop: 192 sensors & modules Addresses per panel: 1536 max. Communication Port: RS232/RS485 Operation Temperature: 10 C~+50 C Related Humidity: 95% (40±2 C) Dimensions (D * W * H): 110 335 435mm Weight: 16Kg. OT502 Addressable Smoke Detector Operating Voltage: DC20V~DC30V Standby current: 0.35 ma Alarm current: 2 ma Wiring: Non-polarized 2 bus lines Address range: 1~192 Dimensions: Diameter 100mm Height 51mm (with base) Weight: 138g OT503 Addressable Heat Detector Operating Voltage: DC20V~DC30V Standby current: 0.25 ma Alarm current: 2 ma Wiring: Non-polarized 2 bus lines Address range: 1~192 Dimensions: Diameter 100 mm Height 38 mm Weight: 125g OA510 Addressable Manual Call Point Operating Voltage: Two-wire bus, DC20V~DC28V, non-polarity Standby Current: < 0.25mA Alarm Current: < 2mA Range of the Address: 1~192 Contact Capacity: DC24V/1A Operating Environment: Temperature: 10 C~+50 C Related Humidity: 95% (40±2 C) Dimensions: Diameter 130 mm Height 49 mm Weight 150g

OS531 Addressable Horn Strobe Operating Voltage: DC18V~DC26V Alarm current: 80 ma Sound Level: 90dB Flashing Times: 40 per minute EDWARDS BRAND CONVENTIONAL (Edwards Brand) UL SFP-302G-2 Edwards Control Panel for Fire Alarm System 2 Zones w/battery SFP-502G-2 Edwards Control Panel for Fire Alarm System 5 Zones w/battery SFP-1004G-2 Edwards Control Panel for Fire Alarm System 10 Zones w/battery Edwards Conventional Smoke Detector (721UT) Edwards Conventional Smoke Detector (721U) Edwards Conventional Smoke Detector (281BPL) Edwards Conventional Manual Pull Station (270ASPO)

Edwards Conventional Alarm Bell MB624 EDWARDS BRAND ADDRESSABLE (Edwards Brand) UL QS4-5-G-2) addressable fire alarm control panel 4 loops with 4 built in systems relays, 14 line (224 character) backlit LCD Display, 6 amp power supply, charger & maintenance free rechargeable batteries components are: (1 ) FAP with 5 option card gray enclosure, 230V ( 3 ) Signature Loop Intelligent Controller ( 2 ) Battery 12AH, 12 Volt cells IO Series (IO500G-2) addressable fire alarm control panel 2 loops with 4 built in systems relays, 4 line (80 character) backlit LCD Display, 6 amp power supply, charger & maintenance free rechargeable batteries components are: (1 ) FAP with 5 option card gray enclosure, 230V ( 1 ) Expansion Loop for 0500 Systems ( 2 ) Battery 12AH, 12 Volt cells EST3 Fire Alarm Control Panel complete with power supply charger, sealed lead acid maintenance free rechargeable batteries to power the system for 24 hours standby and 30 minutes alarm conditions, includes; (1) Central Processor Module (1)RS232 Communication Card (2) Single Loop SIGA data Controller (1) Liquid Crystal Display Module (1)12 switch, 12 yellow, 12yellow Ctrl Display Module (1) Primary Power Supply 230V (1) Seven Space Chassis with rails (2) Blank LRM Filter

(1) White Backbox with 7x LRM Spaces No Door (1) White Door Asembly for 3-CAB7 (1) Battery Cabinet (2) Battery 12v @ 24Ah Addressable Photoelectric Smoke Detector (SIGA-PS) w/ SIGA-SB base Addressable Photoelectric Heat Detector (SIGA-HRS) w/ SIGA-SB base Addressable Manual Pull Station-Double Action, 1-stage (SIGA278) Addressable Temporal Horn Strobe 24V (757)