PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy

Similar documents
SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER

CHAPTER 3 BASIC STEAM CYCLE

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

POWERENERGY

POWERENERGY

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

MECHANICAL SCIENCE Module 2 Heat Exchangers

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

POWER Selecting Shell Side Design Temperature for Feedwater Heaters

Solution of I Mid Term Steam Engineering 6ME5A

HEAT EXCHANGE INSTITUTE, INC.

Efficient Steam System Design

A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. Heating Equipment and System

Chapter 10 VAPOR AND COMBINED POWER CYCLES

Boiler Basics. Design and operation

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Week 13 Chapter 10 Vapor & Combined Power Cycles

Marine Heat Exchangers SALES SERVICE REPAIR

Silhouette. Feedwater Heater. Boiler Feedwater

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Heat Transfer Equipment

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Heat Transfer Equipment - Heat Exchangers. UAE, Dubai, Cityseason Suites Hotel. Training Course : Training Course For One Week In

Chapter 11. Design of Other BOP

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Alfa Laval spiral heat exchangers

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

2017 FSRUG Thermal Performance Feedwater Heater Troubleshooting FSRUG FWH Troubleshooting 1

Top performance when the going gets tough

Points to be Considered when Purchasing a Steam Jet Vacuum Pump

What to Expect from Your EtaPRO Investment

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Chapter 8. Production of Power from Heat

ALLEGHENY BRADFORD CORPORATION

Secondary Systems: Condensate/Feedwater Cycle

Steam Power Cycles Part II

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Waste-heat recovery: Weighing in the environmental Factor

How is the heat transfer?

Homework #4 (group) Tuesday, 27 by 4:00 pm 5290 exercises (individual) Tuesday, 27 by 4:00 pm extra credit (individual) Tuesday, 27 by 4:00 pm

Innovate & Implement

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Foster Wheeler Condensers and Feedwater Heaters. High Quality Steam Components

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

FOR THE PETROLEUM AND RELATED INDUSTRIES

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

Chapter 2.3: Steam System

Modern Heat Exchanger - A Review

the new standard in Heat Transfer Equipment Century Series Heat Exchangers

LONGONI ENGINEERING SRL

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

LIFE MANAGEMENT OF FEEDWATER HEATERS AT KCPL

Mechanical Engineering Department Sheet (1)

Air-Cooling Evaporators

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

Engineering Thermodynamics. Chapter 7

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

Power Boiler Design, Inspection, and Repair

Deaerator. Specifications

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Understanding Process Vacuum for Process Improvement

PALO VERDE NUCLEAR GENERATING STATION

No matter how adventurous a process engineer may

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

INFINITY FLUIDS CORPORATION

E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)

PIPING SYSTEM EQUIPMENTS

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Heat Transfer Equipment Overview Core COPYRIGHT. Types of Heat Exchangers and Their Common Applications in Oil and Gas Processing Facilities

Boiler. Fire tube Boiler:

LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS

Nuclear Electric Heating

Miniature Hobby Boiler Inspection and Certification Requirements

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

SECTION HEATING BOILER FEEDWATER EQUIPMENT

GESTRA Information A 1.7

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

IN THE PULP AND PAPER INDUSTRY

.005 ATMOSPHERIC DEAERATOR

Thermodynamics: Homework A Set 7 Jennifer West (2004)

OPTIMIZING THE BALANCE-OF-PLANT FOR A CYCLING COMBINED CYCLE OTSG FACILITY Vito Raponi, EIT, CAPM*, Larry Guy, P.Eng.**

Homework Chapter2. Homework Chapter3

Transcription:

February 15, 2013 PV Newsletter Monthly Publication from CoDesign Engineering Skills Academy www.codesignengg.com Classification of Shell-and-Tube Heat Exchangers Shell-and-tube heat exchangers can be classified based on construction, or on service. Both classifications are discussed in the paragraphs below. Classification based on construction Fixed Tubesheet A fixed tubesheet heat exchanger (Figure 1) has straight tubes that are secured at both ends to tubesheets welded to the shell. The principal advantage of fixed tubesheet construction is its low cost because of its simple construction. In fact, the fixed tubesheet is the least expensive construction type, as long as no expansion joint is required. Other advantages are that the tubes can be cleaned mechanically after removal of the channel cover or bonnet, and that leakage of shell-side fluid is minimized since there are no flanged joints. Figure 1: Fixed Tubesheet Heat Exchanger A disadvantage of this design is that the since the bundle is fixed to the shell and cannot be removed, the outside of the tubes cannot be cleaned mechanically. Thus, its application is limited to clean services on the shell-side. However if satisfactory chemical cleaning program can be employed, fixed tubesheet construction may be selected for fouling services on the shell-side. In the event of large temperature differential between the tubes and the shell (generally 50 o C for carbon steel), the tubesheet will be unable to absorb the differential stress, thereby making it necessary to incorporate an expansion joint. This takes away the advantage of low cost to a significant extent. U Tube As the name implies, the tubes of a U-tube heat exchanger (Figure 2) are bent in the shape of a U. There is only one tubesheet in a U-tube heat exchanger. However, the lower cost for a single tubesheet is offset by the additional costs incurred for the bending of the tubes and somewhat larger shell diameter (due to the minimum U-bend radius), making the cost of a U-tube heat exchanger comparable to that of the fixed tubesheet heat exchanger. Page 1 of 12

The advantage of a U-tube heat exchanger is that because one end is free, the bundle can expand or contract in response to stress differentials. In addition, the outsides of tubes can be cleaned as the tube bundle can be removed. The disadvantage of U-tube construction is that the insides of the tubes cannot be leaned effectively, since the U-bends would require flexible-end drill shafts for cleaning. Thus U-tube heat exchangers should not be used for services with dirty fluids inside the tubes. Floating Head Figure 2: U-Tube Heat Exchanger The floating head heat exchanger is the most versatile type of shell-and-tube heat exchanger, and also is the costliest. In this design, one tubesheet is fixed relative to the shell, and the other is free to float within the shell. This permits free expansion of the tube bundle, as well the cleaning of both the insides and outsides of the tubes. Thus floating head heat exchangers can be used for services where both the shell-side and the tube-side fluids are dirty - making this the standard construction type used in dirty services, such as in petroleum refineries. There are various types of floating head constructions. The two most common are the pull-through with backing device (TEMA S) and pull-through (TEMA T) designs. These are depicted in Figures 3 and 4 respectively. Figure 3: Pull-through Floating Head Heat Exchanger (TEMA S) The TEMA S design is the most common configuration in the chemical process industries. The floating head cover is secured against the floating tubesheet by bolting it to an ingenious split backing ring. This floating head closure is located beyond the end of the shell and is contained by a shell cover of a larger diameter. To Page 2 of 12

dismantle the heat exchanger, the shell cover is removed first, then the split backing ring, and then the floating head cover, after which the tube bundle can be removed from the floating end. Figure 4: Pull-through Floating Head Heat Exchanger (TEMA T) In the TEMA T construction, the entire tube bundle, including the floating head assembly, can be removed from the stationary end, since the shell diameter is larger than the floating head flange.the floating head cover is bolted directly to the floating tubesheet so that a split backing ring is not required. The advantage of this construction is that the tube bundle may be removed from the shell without removing either the shell or the floating head cover, thus reducing maintenance time. This design is particularly suited to kettle reboilers having a dirty heating medium where U-tubes cannot be employed. Due to the enlarged shell, this construction has the highest cost of all exchanger types. Classification based on service Basically, a service may be single phase (such as cooling or heating of a liquid or gas) or two phase (such as condensing or vaporizing). Since there are two sides to shell-and-tube heat exchangers, this can lead to several combinations of services. Broadly services can be classified as follows: Single-phase (both shell-side and tube-side) Condensing (one side condensing and the other single-phase) Vaporizing (one side vaporizing and the other single-phase) Condensing/ vaporizing (one side condensing and the other vaporizing) The following nomenclature is normally used: Heat Exchanger: Both sides single phase and process streams (as opposed to utility) Cooler: Heater: Condenser: Chiller: One stream a process fluid and the other cooling water or air One stream a process fluid and the other a hot utility such as steam or hot oil One stream a condensing vapor and the other cooling water or air One stream a process fluid being condensed at sub-atmospheric temperature and the other a boiling refrigerant or process stream Page 3 of 12

Reboiler: Sources: One stream a bottoms stream from a distillation column and the other a hot utility (steam or hot oil) or a process stream 1. Effectively Design Shell-and-Tube Heat Exchangers by Rajiv Mukherjee *** E N D O F T H E A R T I C L E *** Bonus Article The Power Plant Steam Cycle by Stanley Yokell INTRODUCTION This brief article is based upon the course notes that Carl F. Andreone and the author prepared for the course that we jointly present to power plant engineers for many years. Power plants are designed to produce power at the lowest cost of input energy that will produce the desired output of kilowatts (KWs). Their designs are based upon estimates of the cost of fuel to make the steam that feeds the turbine-generator system and the selling price of the output KWs over the projected life of the plant. Usually the utility owner selects the turbine-generator set and the steam generator needed to supply the steam to the turbine-generator. The AE then optimizes the BOP design. In addition to the building design the BOP design includes the optimization of the main steam condenser, pumps and feedwater heaters. The figures in this chapter use typical data to illustrate the steam cycle. In the basic steam cycle (Fig.1-1) steam exits the steam generator and enters the main turbine at high temperature and pressure. Steam expands through the turbine thus producing usable shaft power that is transferred to the generator to produce output KW. The steam that exits the turbine exhaust is condensed to water in the main condenser. From there it is pumped back to the steam generator. Heat energy is added in the steam generator to produce high temperature high-pressure steam and the cycle repeats itself. The steam cycle efficiency can be improved by raising the feedwater temperature that enters the inlet of the steam generator. The higher the feedwater temperature is raised, the more efficient the cycle will be. To achieve this increase in efficiency heat exchangers (FWHs) are installed in the feedwater flow path between the condenser and the steam generator. (Fig. 1-2) Steam, extracted from the turbine at various pressure levels, is fed to the shell sides of the FWHs to heat the feedwater which flows through the tubes. The improvement in the plant heat rate when additional heaters are placed in the feedwater flow path to increase the feedwater temperature to the steam generator is shown in (Fig. 1-3). Another commonly used method to raise steam cycle efficiency is to take partially expanded steam which is still at relatively high pressure from the turbine and return it to the steam generator to be reheated. This steam is then reintroduced to the turbine at an appropriate lower pressure admission point where its power producing expansion is continued. TYPES OF FWHs Two types of feedwater heaters are in use in most power plants: The direct contact or open type and the shell and tube or closed type. This article deals with the closed feedwater heater type. However, it briefly discusses direct contact type (Deaerators). Page 4 of 12

Deaerators Deaerators heat the feedwater to the saturation temperature of the extraction steam being supplied to the heater. In addition to heating the feedwater the Deaerator removes dissolved gases in the feedwater in order to lower the oxygen content to desired levels to minimize corrosion in the system. It also provides a large storage volume at the suction of the feed pump to provide some cool down time when the plant is tripped to minimize excessive thermal transients in the boiler/steam generator. Closed FWHs The second type of FWH is the closed feedwater heater discussed in the following.. These are arranged in the following broad classifications: Single-Zone Two-Zone Three-Zone Steam condensing only Steam condensing with condensate subcooling, or Steam desuperheating with steam condensing Steam desuperheating, steam condensing, and condensate subcooling. The Heat Exchange Institute (HEI) Closed Feedwater Heater Standards have illustrations of zone arrangements and heater installation positions. Single zone heaters Single zone FWHs usually take extraction steam from the lowest pressure end of the turbine. They are condensing only heaters. Using heaters with a subcooling zone to heat feedwater with extraction steam from the lowest pressure stage of the turbine must be evaluated carefully over the complete anticipated operating range of the plant. The low-load operating conditions often result in such low extraction pressure steam as to make the hydraulics of a subcooling zone marginal. In such cases, an external subcooler might be included in the cycle. Two-zone heaters When extraction steam pressures are higher at all considered loads, a subcooling zone will improve the heat rate. With one exception it is always included. The one exception is when condensate from the heater is pumped forward into the feedwater stream. In this circumstance no subcooling is appropriate because the energy in the condensate is going directly into the feedwater stream. For this exception the location of the pump relative to the heater must be such that it precludes the need for a subcooling zone to protect the pump from flashing condensate at the pump inlet. Three zone heaters In fossil fuel power plants steam leaves the boiler with great amounts of superheat. Consequently even after the steam has been partially expanded in the high pressure stages of the turbine, extraction steam entering the shells of the high pressure heaters can have as much as 100 F to 400 F of superheat. When extraction steam has sufficient amount of superheat, at all loads considered, a three zone heater that includes a DSH zone will be provided. This reduces the amount of steam extraction required to raise the temperature of the feedwater, thereby further improving the heat rate. THERMAL PERFORMANCE The thermal performance of closed feedwater heaters is measured by two values, the TTD and the DCA. Their definitions are repeated here. TTD is the temperature difference between the saturation temperature corresponding to the inlet steam pressure at the shell inlet and the temperature of the feedwater at the tubeside outlet. Page 5 of 12

DCA is the temperature difference of the shellside drains at the shell outlet and the temperature of the cold feedwater at the tubeside inlet. Selecting the TTD The TTD of feedwater heaters without DSH zones is always a positive value. The turbine manufacturer s initial heat balance kit usually suggests a TTD of +5 F, which is the basis for the turbine-generator KW output rating. However, based on plant economics, heater optimization studies usually result in specifying +2 F TTD for horizontal heaters without DSH zones. The same approach can be expected with heaters that are installed in the vertical head up orientation. But, because a liquid level is maintained in the bottom of the shell in vertical head down heaters in order to maintain a liquid seal above the subcooling zone, it is generally not recommended that the TTD in these instances be less than +5 F. When DSH zones are included in the FWH design, the TTD is usually specified in a range of 0 F to -3 F, depending on the amount of superheat available in the entering steam at all operating loads considered. A conservative guideline based on design point basis steam extraction conditions is as follows: Suggested TTD, F ( C) Amount of Superheat available, F (~ C) 0 (0) 150 200 (65 95) 1 (1.8) 200 250 (95 120) 2 (3.6) 250 300 (120 150) 3 5.4 >300 (>150) Top heater TTD Unlike the other heaters in the system, selecting the top heater TTD requires considering the effect on turbine KW output. If the steam flow capacity in the cycle is constant, as in a fossil fueled unit where the main steam valve and the turbine design limit the amount of steam that can flow to the turbine, lowering the TTD will result in power generation losses while improving the heat rate. The optimal TTD strikes a balance between loss of power and lowered fuel costs associated with the lowered TTD. When the steam flow capacity in the cycle is heat input limited, as in a nuclear unit where the heat input to the steam generator is held constant for optimum fuel economy, then the most power generation at the lowest heat rate is achieved by providing the lowest practical TTD. Selecting DCA Most DC designs follow the recommendations in the HEI Standards for Closed Feedwater Heaters. The HEI standard recommends that the DCA not be +10 F ( +18 C). DCA temperatures based on heater optimization studies range from +15 F ( +37 C) to as low as +8 F ( +14.4 C). The lower DCA can usually be justified in large nuclear plant FWHs because the cascading drain flows contain considerable available heat. Low pressure vertical head down FWHs that have large amounts of cascading drains and do not include a DSH zone will tend go to +15 F (37 C) DCA to minimize the dead surface outside the DC zone. Effects of TTD and DCA on Cycle Performance Except for the highest-pressure heater a decrease in the TTD of a particular heater primarily affects two heaters. As the TTD decreases, the extraction steam flow to the subject heater increases, as does the rise in feedwater temperature. The resulting increase in duty requires more extraction steam. The lower flow through the next turbine stage tends to decrease power output. There is an increase in feedwater inlet temperature to the next higher-pressure heater, decreasing extraction flow to that heater. This results in increasing the amount of steam available between the two extraction points. The expansion of this additional steam at higher pressure and temperature produces a net improvement in cycle efficiency, with no change in cycle heat input. Page 6 of 12

At the highest-pressure heater, a decrease in heater TTD has a somewhat different effect. When the turbine steam flow is constant, the lower flow through the next turbine stage will decrease the power output. However, since the feedwater temperature to the economizer is higher and the reheater duty is lower, the lower heat input to the boiler will have to be evaluated against the KW output loss to determine the optimal TTD. Except for the highest-pressure heater a decrease in the DCA of a particular heater actually affects three heaters. The extraction steam flow to a particular heater will decrease slightly as the duty in the DCA zone increases and warmer feedwater enters the condensing zone. Not as much steam is extracted from the turbine, which increases the power output. The additional steam flow within the next turbine stage results in a small increase in the extraction pressure of the subject heater thereby slightly increasing the feedwater outlet temperature. The higher feedwater inlet temperature to the next higher-pressure heater results in lowering the extraction steam flow to that heater. At the same time, the cooler drains are cascaded to the next lower pressure heater, slightly increasing the extraction load. The net effect to the cycle is an increase in output and cycle efficiency because expansion of more steam at higher pressure and temperature produces more work. Note that there will be no change in heat input. Lowering the DCA of the highest-pressure heater will slightly reduce the amount of steam extraction to the heater with a corresponding slight increase in the power output. The reheater duty will increase slightly, however the slightly higher feedwater temperature resulting from the same type of extraction pressure increase discussed above may or may not overcome this deficit which will impact the heat input to the boiler. It is cycle-dependent still the net effect is improved cycle efficiency and output. Effects of TTD and DCA on Performance Lowering either the TTD or DCA will increase cycle efficiency. The increase will usually be manifested either by an increase in power output, a decrease in heat input, or a combination of the two. In the special case of the highest pressure heater the decrease in power output resulting from a lowered TTD must have a more than compensating decrease in heat input in order to be acceptable. The TTD and DCA represent cost factors that affect the ability of a feedwater heater design to save fuel or to produce more power. When applied, the design may be charged or credited with a performance dollar value that may be used to optimize the heater performance parameters. In addition, the tubeside pressure drop must be considered in the overall heater performance cost because it determines the cost of pumping power used to force the feedwater through the heaters. The value of the pressure drop cost and the way it is calculated is cycle dependent. Feedwater pumps that feed heaters located between the main condenser and the Deaerator are usually motordriven. The pumping costs will be costs of the difference in auxiliary power used by the condensate pumps to overcome the feedwater heater pressure drop. For the heaters between the Deaerator and the steam generator it will consist of the cost difference brought about by the added extraction steam required by the main feed-pump turbine to overcome the feedwater heater pressure drop. With feedwater reheat cycles that do not have a Deaerator the condensate pump supplies the necessary net positive suction head (NPSH) for the intermediate pressure feed-pump and/or the high-pressure feed-pump. Combining the costs associated with heat input, power output, and pressure drop allows a total performance evaluation to be made of the performance parameters of a specific heater. Effects of TTD and DCA on Heater Size The improvement of feedwater heater TTD and DCA will result in an increase in the heat transfer area required to meet the increased duty. If the space is available, the heater diameter can be held unchanged and the tube length allowed to increase to accommodate the increase in heat transfer surface required. This will result in an Page 7 of 12

increase in tubeside pressure drop. If the length becomes too long, the diameter can be increased to accommodate more tubes to satisfy the increased heat transfer surface requirements. This will result in lower tubeside pressure drop. Effects of Tube Size and Material on Heater Size With a given length restriction smaller diameter tubes will accommodate more heat transfer surface in a given shell diameter. This will result in an increase in tubeside pressure drop. The tubeside pressure drop in a heater can be lowered by using larger diameter tubes. This will require a larger shell diameter than would be required for an equal surface area of smaller diameter tubes. When considering prices when buying FWHs keep in mind that longer is less expensive for designs that satisfy the performance requirements. Tube materials with low thermal conductivity characteristics, such as austenitic stainless steels, require more heat transfer surface than ones with high thermal conductivity such as ferrous and non-ferrous tubes to satisfy the performance requirements Effects of TTD and DCA on Heater Cost Any decrease in either TTD or DCA will cause an increase in heat transfer area, with an attendant increase in cost. The lowering of the TTD from +5 F (9 C) to +2 F (3.6 C) in a heater without a DSH zone will increase the cost by about 25%. This is usually acceptable based on plant economics. The lowering of the TTD from 0 F to -3 F( +37 C) in a heater with a DSH zone will increase the cost by approximately 5-10% per degree in this range. The incremental cost of a lower DCA is generally unacceptable when lowering the DCA below the 15 F to 10 F (27 to 18 C) range. Base loaded plants will optimize with +10 F(18 C), while cycling plants will probably settle at +15 F (27 C), as well as in vertical head down heaters without a DSH zone. A large plant of about 1000 megawatts (MW) or more, may be able to justify +8 (14.4 C)F. Feedwater Heater Optimization With all of the above costs and physical limitations either known or easily calculable, optimal values of TTD and DCA can be assigned that represent the best choice of heaters for a particular cycle. The procedure is to optimize the TTD and DCA separately for each heater. This must be done several times for a given cycle to ensure that convergence has been achieved at all heaters. Occasionally, the optimal value(s) for a given heater will change as a result of the optimization of an adjacent heater. Consideration must be given to physical constraints. If the length of an optimized heater is too great, it will have to be resized with a lower tubeside velocity. This would make the heater diameter larger while decreasing its length. It would not be the lowest cost heater but it would be the best choice, all things considered. Capitalized performance costs are combined with estimated capital costs in the pre-bid stage to arrive at the lowest total evaluated costs (Fig.1-4). The heaters can then be specified with the optimized TTD and DCA values. Page 8 of 12

Figures Page 9 of 12

Page 10 of 12

Sources: 1. The Choice Of Terminal Temperature Difference for Closed Feedwater Heaters in a Steam Cycle, P.A. D Errico and C.F. Andreone, IEEE/ASME JPGC, Oct. 1989 2. HEI, Standards for Closed Feedwater Heaters, 8 th Ed., The Heat Exchange Institute, Cleveland, Ohio *** E N D O F T H E A R T I C L E *** About CoDesign Engineering: CoDesign Engineering specializes in the core business of providing training and consultancy for design and fabrication of ASME code pressure vessels, and the ecosystem that includes piping, welding, valves, geometric dimensioning and tolerancing, process improvement, and engineering management. Some of the training courses (lasting from two days to five days) that we provide include: Design and Fabrication of ASME Section VIII, Div. 1 Pressure Vessels Design and Fabrication of ASME Section VIII, Div. 2 Pressure Vessels Shell & Tube Heat Exchangers - Thermal and Mechanical Design ASME Section IX - Welding Technology Engineering Management We also provide several one-day workshops: Know Your Power Piping Know Your Process Piping Know Your ASME Section VIII Pressure Vessel Code Know Your Shell & Tube Heat Exchangers A to Z of Pressure Vessels Transitioning to ASME Section VIII, Div. 2 Our trainings can be offered at most cities in India and in US. Please contact info@codesignengg.com for the training calendar and rates. Visit our website www.codesignengg.com for contents of the courses. Page 11 of 12

Did you like this article? I would request you to provide me your feedback on the article in this newsletter (and the previous newsletters as well). I would also request you to send me email addresses for your acquaintances that would benefit by receiving this newsletter. If you would like to contribute articles, please let me know. Finally, if you would like the newsletter to be sent to a different email address, or not receive it at all, kindly email me at ramesh.tiwari@codesignengg.com. Ramesh Tiwari holds a Master s degree in Mechanical Engineering from Clemson University in South Carolina, and is a registered Professional Engineer from the state of Maryland in the United States. He has over 22 years of experience designing pressure vessels, heat exchangers and tanks. Ramesh is a member of ASME Section VIII Subgroup on Heat Transfer Equipment, and member of ASME B31.1 IWG for Power Piping. He is also an approved pressure vessel instructor at National Thermal Power Corporation (NTPC), a premier thermal power generating company in India. Disclaimer: I feel it is necessary to place a disclaimer statement to protect myself, the contributors and the newsletter. The information provided in this newsletter is for educational purpose only. As a qualified engineer, I take this opportunity to remind all potential users that it is YOUR responsibility to ensure that all designs are verified, and that such designs comply with the current editions of the relevant codes. I accept no liability for any loss or damage which may result from improper use of information in this newsletter. Page 12 of 12