C13-Series. Unique Solutions for All-Indoor HVAC Projects

Similar documents
C-Series. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV Engineering Guide

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

CoolSpot Engineering Guide

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

OmegaAir. 100% Dedicated Outside Air System (DOAS)

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

Modular Indoor Systems For Effective Environmental Control

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Flexible & Innovative. Cooling Solutions

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

HVAC 101. H V A C S y s t e m s

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons

62DA,DB,DC,DD,DE,DF07-38

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Liebert Mini-Mate2 1 To 8 Tons

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Marvel J MICROPROCESSOR CONTROLLER

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

TECHNICAL SPECIFICATIONS

PACKAGE AIR CONDITIONER

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

50 Series AQUAZONE Water Source Heat Pumps

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

The ultimate fresh air solution.

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

ENGINEERING. Edition No. 13 October 2002

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TM GAS HEATING/ELECTRIC COOLING UNITS

Highly Efficient,Powerful Heating and Cooling.

Split System Heat Pumps

August 15, 2013 Page 1 of 19

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance Line

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

RT-OA TM Rooftop Outdoor-Air (DOAS)

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

GP SERIES Packaged Chillers

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Classic 10. Self-contained and portable, the Classic 10 requires little or no installation, simply roll it in, plug it in and turn it on.

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Transcription:

C13-Series 2 to 10 Tons Horizontal Self-Contained or Split Systems Air-Cooled, Water-Cooled, Chilled Water, Water Source Heat Pump, Air Source Heat Pump Unique Solutions for All-Indoor HVAC Projects

C13-Series Air-Cooled Water-Cooled Water Source Heat Pump Air Source Heat Pump Ultra-Flexible Splittable Indoor Air Conditioning Systems United CoolAir has set the standards for splittable units since 1988. The C13 Series builds on that history by being one of the most versatile horizontal indoor air conditioning systems available today! Roofs on buildings have gotten to be very crowded places for equipment. The IN- DOOR location of the C13-Series provides many freedoms and benefits. Sloped roofs, those with living roofs and the general appearance of structures can be improved with the use of an indoor air conditioner. There is no roof loading to contend with and also no vandalism, storm issues, or roof penatrations. The C13-Series Horizontal air conditioner is designed as a flexible ducted indoor air conditioning system for commercial cooling applications and is ideal for retrofit and renovation projects. It is available in three cabinet sizes with capacities from 2 to 10 tons. An indoor condensing section is standard along with optional air path configurations. Units are manufactured using readily available components, simplifying lifetime maintenance. Other quality features include filter driers, sight glasses and stainless steel sloped evaporator drain pan for positive condensate removal. The splittable design minimizes ductwork by allowing the condensing section installation away from the evaporator (close to an outside wall, air shaft or any location suitable for heat rejection) without the loss of factory charge. FEATURES 2 to 10 tons Air-Cooled, Water-Cooled, Chilled Water, Water or Air Source Heat Pump Single Package or Splittable Premium Efficiency Motors IAQ-Style Double Sloped SS Drain Pan Variable Pitch Drives Allow Adjustable Static Pressure Dual Independent Control Panels (split systems) Functionally Run-Tested Prior to Shipment APPLICATIONS Offices Retail Spaces Schools/Universities Healthcare Buildings Restaurants Historical Buildings Industrial/Manufacturing Remote or Isolated Areas Add-on Spot Cooling Electrical Equipment Rooms Limited Access Areas Offering a Wide Variety of Options for your Unique Application Powder Coated Cabinets Non-Fused Disconnects Electric Heat Freezestat Condensate Pump (externally mounted) Air Side or Water Side Economizers Upgraded Motors, Evaporator or Condenser Double Wall Cabinet Construction Flooded Condenser (Down to -30 F) (Perforated or Solid) Hot Gas Bypass Auxiliary Coils (Steam, Hot Water or Chilled Water) Variable Frequency Drive (Low Ambient) Hot Gas Reheat Steam Canister Humidifier Head Pressure Control Valves Protective Coil Coatings Marvel Microprocessor Controls Drain Pan Overflow Switch BMS Interface 2

Total Installed Cost Advantages Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to-Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3

C13-Series Flexibility and efficiency are paramount in today s buildings. The ability to split air conditioning units, either for final installation or simply to move the unit into location, are assets that are extremely beneficial for historical sites and for renovation or replacement projects. Water-Cooled packaged system, Air-Cooled packaged system and Air-Cooled split system shown Flexibility and efficiency are paramount in today s buildings. The C13-Series can be installed as a single packaged system or the evaporator and condensing section can be split. The units can be ceiling mounted or slab mounted. Being able to tailor the units with a wide range of options and different air path configurations provide additional design and installation flexibility. The heat of rejection can be accomplished with air or water as the transfer medium. Refrigerant Line Lengths up to 250 Equivalent Feet! The ability to split the units, either for installation or simply to move the unit into location, are assets that are extremely beneficial for historical sites and for renovation or replacement projects. Not to scale. For illustrative purposes only. Single Packaged System Split System 4

C13-Series Physical Data Tons 2 3 4 5 6 8 10 Air-Cooled Total (a) BTUH 24,490 36,920 46,280 58,620 75,840 90,395 115,350 Sensible (a) BTUH 17,460 26,650 34,560 42,550 55,290 67,690 89,400 Heating Capacity 47 DB / 43 WB 23,410 34,200 42,760 57,800 72,055 84,740 106,600 17 DB / 15 WB 14,940 22,650 27,635 37,345 44,845 55,682 72,320 Condenser Air CFM 1600 2000 2500 2900 4000 5200 5000 Std. ESP 0.25 Evaporator Supply Air CFM 800 1200 1600 2000 2400 3200 4,000 (Air- or Water-Cooled) Std. ESP 0.25 Water Cooled Total (a) BTUH 25,210 37,910 48,350 61,675 78,260 94,535 128,370 Sensible (a) BTUH 17,800 27,030 35,465 43,785 56,440 69,335 95,320 Heating Capacity 28,880 44,500 54,665 71,700 89,130 108,845 143,750 Estimated Weights (b) Air-Cooled 725 730 1,055 1,075 1,575 1,610 1,720 Water-Cooled 580 590 860 885 1,190 1,260 1,290 Dimensions (Inches) (e) Length aircooled 55 61 70-1/2 89 Length watercooled (c) 83 91 113-1/2 117 Width (d) 59 67 73-1/2 83 Height 23-1/8 26-1/8 33-1/8 Available Voltages 208/230-1-60 208/230-3-60 460-3-60 575-3-60 (a) Capacities are gross values and are not adjusted for motor heat. (b) Net Operating weight is for basic unit only. Options will add weight. (c) Length is for basic water-cooled unit. Actual length may be more dependent upon options selected. (d) Allow 36 clearance on each side. (e) Refer to United CoolAir s website at www.unitedcoolair.com for specific unit detail drawings. 5

C13-Series Reliable State-of-the-Art Control Solutions The C13-Series system controls can be as simple as a wall mounted thermostat (programmable or non-programmable) up to a full featured microprocessor. The unit application will typically dictate what type of control is required. United CoolAir offers two levels of microprocessor controls for this system Marvel J and Marvel S. Both of these can be interfaced with Building Management Systems (BMS) such as BACnet, ModBus or LonWorks. If desired or required, up to 16 units can be networked together through a single wall display. The Marvel J provides the entry level of microprocessor control. This is useful where a standard thermostat simply is not enough, but only a few options need to be controlled or reported. The Marvel S is a medium capacity controller that is full featured. This means it has more abilities to receive inputs from various sensors and to output more signals to control devices within the system. The sophistication is also expanded by Providing signals for modulating valves, not just an On / Off signal. Marvel J Marvel S Entry Level Basic System Temp / Humidity Control Up to 2 Stages of Heat/Cool 2 Temp/Humidity Sensors 2 Modulating Analog Outputs Can be Password Protected Auto Daylight Savings Built In Help Menus Fan Status, Cooling Stages, and Heating Stages Loss of Airflow On Screen Displays of Demands Medium Capacity Full-Featured System Additional Inputs / Outputs Up to 3 Stages Compressors and 4 Stages Heat Electronic Modulating Hot Gas Valves Suitable for Heat Pump Systems J S Marvel BMS Marvel BMS 6

Mercedes Benz C13-Series Case Study Long Beach, CA United CoolAir s C13 Horizontal Ducted In-Door System Solves Historic Building Requirements. United CoolAir s C13 versatility for retrofit and renovation projects provides an all indoor solution when there is no option for installation on the roof or ground mounted equipment. Due to zoning restrictions pertaining to alterations of historical structures, no equipment could be mounted on the buildings exterior. Mercedes Benz had acquired a historical location in Long Beach, CA. Due to unprecedented growth for luxury cars in southern California. The long standing historic DC Jets facility was selected spanning 1.1 million square feet and home to Douglas Aircraft and eventually Boeing who both produced aircraft for the military and commercial industries. This historic location at Conant Street and Lakewood Boulevard opened in 1941. Mercedes Benz will utilize the facility as a vehicle preparation center, which will be responsible for ensuring Mercedes-Benz cars are ready to be shipped to various dealerships throughout the USA. This is one of only three facilities in the United States. This newly renovated facility including United CoolAir equipment will employee an estimated 200 employees. The use of the C13 was paramount in the design of the HVAC equipment. Because the city of Long Beach designating this historical site there were certain restrictions on the renovation for Mercedes. First, there was no ability to place equipment on the massive roof. Secondly, the face of the building could not have any equipment on the exterior. It was determined that a C13 ducted horizontal unit would be installed indoors. The contractor was able to duct the condenser air out the side of the building through a louver. 24 C13 air source heat pumps were installed providing cooling and heating to a variety of spaces from offices to training bays for factory training for Mercedes technicians. Tonnage ranged from 3 to 8 tons and all had airside economizers as well. A challenging historic landmark was exactly what the C13 was designed to solve. Not only did the C13 solve the problem presented it will also be easier to service inside the building envelope, be protected from the outdoor environment and provided a complete solution utilizing one product. NOTABLE CLIENTS CVS Rite Aid Gap Store Sirius XM TTC (Canadian Subway) DC Metro Sikorsky Nordstrum PayPal Starbucks Visit www.unitedcoolair.com or call the factory at 717-843-4311 for more information 7

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons OmegaAir Vertical 100% Outside Air, 1-15 Tons OmegaAir Horizontal, 100% Outside Air, 1-15 Tons Special Configuration Engineered to Order LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. Authorized Distributor: FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2015. All rights reserved. Manufacturer reserves the right to make changes without notice. 10.2-SB (0117)