JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Similar documents
Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

CAUTION. No-Load Performance, Controls in Normal Position

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Bottom Mount Refrigerator---Technical Information

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Bottom Mount Refrigerator Technical Information

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

Image Key Part Number Description Substitution Qty.

FOR SERVICE TECHNICIAN S USE ONLY

Image Key Part Number Description Substitution Qty.

FOR SERVICE TECHNICIAN S USE ONLY

SERVICE NOTEBOOK BUILT-IN REFRIGERATOR VCSB481 / VCSB482

Fast Track Troubleshooting

Fast Track Troubleshooting

3. OPERATING INSTRUCTIONS & INSTALLATION

Fast Track Troubleshooting

Fast Track Troubleshooting

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Side-by-side combined refrigerator-freezer

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

KM-630MAH KM-630MWH KM-630MRH

Ice Maker (Fresh Food Compartment)

Fast Track Troubleshooting

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

4. ALIGNMENT AND ADJUSTMENTS

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

2010 Whirlpool 26 SXS Refrigerators

Product Information and Technical Guide

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

KM-61BAH KM-101BAH KM-151BAH

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

T-32-TS Touchscreen Thermostat. Installation Manual

Smart Temp. ApolloP/n Installation Manual. Version 1.0

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM-500MRH SERVICE MANUAL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Service Documentation

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

TECHNICAL SERVICE GUIDE

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Fast Track Troubleshooting

REACH-IN SAFETEMP (-AAC)

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Product Information and Technical Guide

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

rlrm MOflel S DE-BY-SIDE REFRIGERATOR Always consult the Use & Care Guide for more operating information.

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

User s Manual

TECHNICAL SERVICE GUIDE

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

User Guide ems25plus. Page 1. Normal operation. Product interface

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Product Information and Technical Guide

2 INSTALLATION OPERATION FUNCTIONS SAFETY Compressor Compartment... 10

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Service Documentation

Air Conditioning Operation and Troubleshooting Matt Dunham

INSTALLATION INSTRUCTIONS

Hoshizaki America, Inc.

Peachtree City is home office for America located about 30 miles south of the Atlanta airport this is were all KM cubers as well as Flakers are built.

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

Service Step by Step Trouble-Shooting Check-List

HPXA19. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Prodigy Flaked and Nugget Ice Machines Technical Review

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Upright S-Series. hoshizakiamerica.com

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

G&F Manufacturing Service Manual Version 2.0 April 2010

Prodigy Plus - D Series Cuber Technical Review

MACH N-407 Heat Pump Air-Cooled Chiller

Scotsman Technical Training. CU50 Cube Ice Machine

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Heat Pump Defrost Board Replacement Kit

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Installation Instructions

Transcription:

Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. Refer to Service Manual 16025629 for installation, operating, disassembly, icemaker, testing, and troubleshooting information. CAUTION All safety information must be followed as provided in Service Manual 16025629! servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires Kw/24 hr ±0.4 No-Load Performance, Controls in Normal Position Percent Run Time ±10% Cycles/24 hr ±25% Refrigerator Center Compartment Average Food Temperature ±3 F Freezer Compartment Average Food Temperature ±3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 20 cu ft 1.1 1.7 2.4 35 53 65 39 33 25 38 38 38 0 0-2 Evaporator Outlet ±3 F Evaporator Inlet ±3 F Temperature Relationship Test Chart Suction Line ±7 F Average Total Wattage ±10% Suction Pressure ±2 PSIG Head Pressure ± 5 PSIG Ambient F 70 90 70 90 70 90 70 90 70 90 70 90 20 cu ft -20-17 -20-17 85 105 135 140 0 0 83 135 January 2005 1 16025982

Component Specifications Component Compressor run capacitor Specifications all parts 115VAC/60HZ unless noted Volt... Capacitance... Compressor BTUH... Watt... Current Lock rotor... Current Full load... Resistance Run windings... Resistance Start windings... Electric damper control Thermistor Condenser motor Evaporator fan motor Maximum closing time Temperature Rating RPM Temperature 77 F... 36 F... 0 F... Rotation (facing end opposite shaft) RPM Watt... Current... Rotation (facing end opposite shaft) RPM Watt. Note: Fan blade must be fully seated on shaft to achieve proper airflow. Overload/Relay Ult. trip amps @ 158 F (70 C)... Close temperature... Open temperature... Short time trip (seconds)... Short time trip (amps @77 F (25 C).. Thermostat (Defrost) Volt... Watt... Current... Resistance across terminals: Above 42 F ±5... Below 12 F ±7... Evaporator heater Volt... Wattage... Resistance... 220 VAC 15 µfd ± 10% 905 BTUH 60 Hz / 153 watts 19.0 amps± 15% 1.26 amps± 15% 3.33 ohms± 15% 4.28 ohms± 15% 36 seconds 20 F- 110 F 1 Resistance 10,000 ohms± 1.8% 29,500 ohms± 1.0% 86,300 ohms± 1.8% Clockwise 1120 RPM 3.4 watts±15%@115vac 0.085 amps± 15%@115VAC Clockwise 2800 RPM 6.0 ±15% watts@115 VAC 2.67 amps± 15% 142 F ±9 284 F ±9 10 seconds ±5 11 amps ±2amps 120/240 VAC 495 watts 5.8/2.9 amps 56 K ohms Open Closed 115 VAC 450 ±5% watts @ 115VAC 29 ±5% ohms Control board Volt... 120VAC, 60 HZ See Control board troubleshooting section Water Valve Watts... Brown side 35w,Yellow side 20w Light switch / Interlock Type.. Volt Current.. SPDT NO/NC 125/250 VAC 8/4 amps 16025982 2 January 2005

Programming Mode: NOTE: The Program Code is located on the Serial Plate on this unit after the word Code. 1. Open the Fresh Food door and press and hold the Keypad 2. Press and hold Freezer Temperature Down Keypad. 3. Release the Keypad and wait 3 seconds. 4. The control will display PE to indicate the programming mode. Freezer Order Replace. Refrigerator Fast Ice Reset Filter Vacation Mode Temp Alert Max Cool 5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more. 6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate. Freezer PE0 Fast Ice Order Reset Filter Replace Vacation Mode Temp Alert Max Cool Refrigerator 000 NOTE: If the Program CODE is correct, the Programming Mode is exited by closing the Refrigerator door(s). 7. Press the Refrigerator Temperature UP Keypad or Refrigerator Down Keypad to change the digit value with each key press. 8. The decimal point indicates the selected digit. Press the Freezer Temperature UP Keypad to select the next digit. 9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN Keypad until the Program CODE begins flashing indicating it has been saved. NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by closing the Refrigerator door(s). If the new code is incorrect this process should be repeated after closing the Refrigerator door(s). The Programming mode can be exited at any time by closing the Refrigerator (s) or will exit if unattended for four minutes. Defrost Operation: The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. January 2005 3 16025982

Forced Defrost Mode: The forced defrost function is performed using the Freezer display and Refrigerator keypad. Enter the Forced Defrost Mode by performing the following sequence of events: 1. Open the Fresh Food door and press and hold the Keypad 2. Press and hold Refrigerator Temperature Down Keypad. 3. Release the Keypad Freezer Order Replace and wait 3 seconds. FD appears in left display. Refrigerator. Fast Ice Reset Filter Vacation Mode Temp Alert Max Cool 4. Press the Refrigerator Down Keypad again. SH appears in right display. 5. Press again to force defrost Fd and SH will flash in display indicating unit is in defrost. Service Test Mode: The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode by performing the following sequence of events. 1. Open the Fresh Food door and press and hold the Keypad 2. Press and hold Refrigerator Temperature UP Keypad. 3. Release the Keypad Freezer Order Replace and wait 3 seconds. Refrigerator. Fast Ice Reset Filter Vacation Mode Temp Alert Max Cool 4. Press the Refrigerator UP Keypad again. 5. Display will show 001 in left display and numeric or dashes in right display. 6. Press Freezer Up Keypad and Freezer Down Keypad to toggle through Service Test numbers. Service Test 101 Defrost Heater & Defrost Circuit Press the Refrigerator Up Keypad and Refrigerator Down Keypad to energize or de-energize the Defrost circuit. The display will read OFF when de-energized OP when energized with open defrost thermostat and CL when energized with closed defrost thermostat. Service Test 102 Compressor / Condenser Fan Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Compressor/Condenser fan On and Off. Service Test 111 Fresh Food Fan (if equipped) Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Fresh Food Fan On and Off. NOTE: Display will show state OFF or DC voltage. 16025982 4 January 2005

Service Test 112 Freezer Fan Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Freezer Fan On and Off. NOTE: Display will show state OFF or DC voltage. Service Test 121 Damper Operation Press the Refrigerator Up Keypad and Down Keypad to toggle Damper (OP) open and (CL) closed. NOTE: If damper is opening or closing it will not allow you to toggle damper and beep. Display will show state CL or OP if Damper is in the process of closing or opening. Service Test 131 (3) Bottom Freezer Mullion Heater (if equipped) Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Mullion Heater Off and On. Service Test 141 Fresh Food Thermistor Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 143 Machine Compartment Thermistor Will Show Machine Compartment Temperature or, OP open thermistor or SH shorted thermistor. Service Test 151 Fresh Food State Will show state of Fresh Food. OP (open) CL (closed). NOTE: By pushing fresh food door switch you can toggle state from OP (open) to CL (closed). Service Test 152 Freezer Food State Will show state of Freezer. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle state from OP (open) to CL (closed). Service Test 161 Cube Dispenser (if equipped) Display shows the state of the Cube Dispenser (ON or OFF). NOTE: By pushing Actuator pad you can control state of cube dispenser without opening Ice Chute door. Service Test 162 Crusher Dispenser (if equipped) Display shows the state of the Crusher Dispenser (ON or OFF). NOTE: By pushing Actuator pad you can control state of Crusher dispenser without opening Ice Chute door. Service Test 163 Water Dispenser (if equipped) Display shows the state of the Water Dispenser (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can control state of Water dispenser. January 2005 5 16025982

Service Test 164 Ice Chute Dispenser (if equipped) Display shows the state of the Ice Chute dispenser OP open or CL closed. NOTE: By pushing Actuator pad you can control state of Ice Chute Dispenser. Service Test 165 Dispenser Lamp (if equipped) Display shows the state of the Dispenser Lamp (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can control state of dispenser lamp. Service Test 171 Actuator Pad (if equipped) Display shows the state of the Actuator Pad (ON or OFF). Service Test 172 Sports Fill (if equipped) Display shows the state of the Sports Fill (ON or OFF). Service Test 173 Ambient Light (if equipped) Display shows light sensor measurement (Hi or Lo). Night light will turn on light sensor measures Lo. By changing the sensor s exposure to ambient light you can control the sensor measurement. Service Test 174 Water Actuator Bottom Mount Internal Dispenser (if equipped) Display shows the state of the Water Valve (ON or OFF). NOTE: By pushing Water Actuator you can control state of Water Valve On or Off. Service Test 175 Dispenser Line (if equipped) Display shows the state of the Dispenser Line (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can change state of Dispenser Line. Service Test 181 Keypad Operation Display shows a numeric or letter display indicating the last key pressed. NOTE: Refrigerator Up/Down keypads have no effect when pressed and Freezer Up/Down keypads remain operational. Service Test 182 LED Indicator Operation Press the Refrigerator Up Keypad to show operation of LED Indicators. All LED Indicators will flash. Press twice and LED will stop flashing. Service Test 191 Ice Maker Water Valve Display shows the state of the Ice Maker Water Valve (ON or OFF). 16025982 6 January 2005

Service Test 201 Mullion Heater Override (if equipped) Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Mullion Heater from cycling on with compressor (Off position) to 100% operation (On Position). Service Test 202 Default Defrost Operation Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Defrost Operation from normal adaptive defrost (Off position) to minimum time between defrosts (On position). Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual temperature (Off position) showing temperature set points only (On position). Service Test 211 Fresh Food Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Fresh Food Temperature plus or minus in 1 F increments up to ± 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test 212 Freezer Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Freezer Temperature plus or minus 1 F in increments up to ± 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test 221 Reset Default Settings Press the Refrigerator Up Keypad and Down Keypad to force to def (default factory settings). January 2005 7 16025982

Wiring Diagram 12923201 16025982 8 January 2005