RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Similar documents
1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

ANNUNCIATOR FIXED MODULE

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

July 14, 1999 DF C-100.

DESCRIPTION INSTALLATION

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

* These Remote Mics must be SPRM-GP

June 10, 2002 DF C S2424

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Addressable NAC Output Module D327A

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE BOX

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

ECC-50/100C. Emergency Command Center

Multiple Input and Output Modules

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

SC-6 Six Supervised Control Module

4200 RESCUE ASSISTANCE INSTALLATION GUIDE-OVERVIEW

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

MANUAL RESET ALARM RELEASE

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

The ACM-8R Annunciator Control Module

ECC-50/100(E) Emergency Command Center

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

JDVC Digital Voice Command and Amplifiers Series

Figure 1. Figure 2. See notes 1 and 2 below.

Installation Instructions for W2H Series Signals

MODEL B2 INSTALLATION MANUAL

SAFEPATH Mass Notification System (SPMNS)

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Series DV-100 VoiceLink Operation and Installation Manual

LifeAlarm Fire Alarm Controls

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Booster Power Supply Manual

SP40S-D. Kingfisher Company, inc. Features: Description:

Control Relay Modules

/5121/5122 TrueAlert Power Supply Installation Instructions

RELEASE DEVICE CONTROLS

SAFEPATH DoD facility communications system & expansion options

These instructions detail procedures to follow in order to avoid damage to equipment.

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Annunciator Modules. for Fire Lite Fire Alarm Control Panels. Document # /30/95 Revision:

E3 Series Broadband System

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

F220-B6PS/M. Installation Guide. Addressable Detector Bases

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Autonomous control unit

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

TrueAlert Addressable Notification

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

4100U City and Relay Cards Installation Instructions

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

16 Zone Voice Evacuation VA & PA Sound System

Notification Appliance Circuit Module

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

MMF Six Zone Interface Module

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Pre-Installation Requirements:

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Rev. B. TrueAlert Addressable Controller Application Manual

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Installation Instructions Model SSD-C-REM

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

E3 Series Broadband System

Remote NAC Power Supply D7038

Multi-Application Peripherals and Accessories

R Series Remote Annunciators and Expander Installation and Operation Guide

TrueAlert Addressable Notification Appliances

SP-1000X. Panic Device Power Controller Installation Guide. Rev

IDP-Zone-6 Six Zone Interface Module

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

The System 5000 Operating Manual

AL600ULADA. NAC Power Extender. Installation Guide

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

RMS/RPX Reader. User Manual

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

PN: 51604:A ECN Voice Evacuation Control Panel FIRE COMMAND 25/50X & FIRE COMMAND 25/50XE. Document # /17/02 Rev.

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

Class A and Expansion NAC Modules Installation Instructions

Rev. A. Technical Manuals Online! -

Installation and Operation Guide. EVS-Series. Emergency Voice System. Document: LS SK-E ECN:

Bosch EVAX System - High-rise Applications

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

System Accessories, LCD Annunciators

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

AL800ULADA. NAC Power Extender. Installation Guide

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Transcription:

This product has been certified to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864 9th Edition. The following products have not received UL 864 9th Edition certification and may only be used in retrofit applications. Operation of the RM-1 with products not tested for UL 864 9th Edition has not been evaluated and may not comply with NFPA 72 and/or the latest edition of UL 864. These applications will require the approval of the local Authority Having Jurisdiction (AHJ). AMG-1 Audio Message Generator RM-1 Series Remote s (RM-1, ) Document 51138 Revision B XPIQ Quad Intelligent Audio Transponder The RM-1 Series Remote is compatible with the Digital Voice Command (DVC), XPIQ Quad Intelligent Audio Transponder and AMG-1 Audio Message Generator in all systems that provide a means for remote speaker control through the ACS Series Annunciators. The RM-1 provides remote DVC/XPIQ/AMG message override and/or paging capabilities in these systems. The RM-1 microphone assembly can be installed on the back of an ADP-4 dress panel. The assembly can be installed in a CAB-RM Series cabinet. Output from the RM-1 Series remote microphone is suitable for NFPA Class B operation only. Following is a list of features of the RM-1 Series. Trouble LED Automatic gain control circuit Pluggable terminal blocks Supervised microphone Low level audio (LLA) IN and THRU Form-C trouble contacts Power IN and THRU screw terminals Form-C contacts activated when microphone is in use Power On LED 11/29/05 ECN 05-238 RM1SA.cdr RM1.cdr RM-1 RM1inbox.cdr ADP4RM1.cdr RM-1 on ADP-4 dress panel Figure 1 The RM-1 Series in a CAB-RM or CAB-RMR Document 51138:B 11/29/05 1

Slide-in Label A slide-in label (part number 51146) is provided with each RM-1 Series assembly. Enter the location of the microphone speakers on this label along with any instructions for speaker activation, then slide it into the label slot at the bottom of the assembly. (See Figure 2) INSTALLATION For a custom professional appearance, generate this label with Notifier s LabelEase in Magni Fire Version 3.0 or higher. RM1lbl.cdr Figure 2 Slide-in Label 1. Be sure all power is removed before installing the. Knockouts 2. Pull the required wiring into the CAB-RM cabinet through the knockouts provided. 3. Attach wiring to the pluggable terminal blocks and plug onto the board. Attach grounding wire provided to the screw on the back wall of the cabinet with the washer and nut supplied. (See Figure 3). Attach the other end of the grounding wire to TB1 Earth on the. 4. Carefully slide the board into the cabinet until it rests in the slots on the back wall of the box (See Figure 4a). 5. Secure the in the cabinet with the two self-tapping screws provided (See Figure 4b). Figure 3 Attaching Grounding Wire to Cabinet RM1GRNDG.cdr CABRM1SA.cdr Slots CABRMOPN.cdr Screw Holes Figure 4a Figure 4b Figure 4 Installing the 2 Document 51138:B 11/29/05

ADP-4 Dress Panel Installation of the RM-1 The RM-1 mounts to the back of an ADP-4 dress panel inside an ADP-4 compatible cabinet that has a minimum depth of 3.75 in. ( 9.53 cm). It can be mounted in any of the four positions on the dress panel, with the following exceptions: Do not mount the RM-1 in front of an AA-100/AA-100E or AA-120/AA-120E amplifier; there is not enough room to shut the door of the cabinet if it is placed in front of one of these audio amplifiers. Do not mount the RM-1 in the first position to the right of an AA-30/AA-30E amplifier; there is not enough room for the RM-1 wiring in this position. An RM-1 can fit only in the far right position of a row if an AA-30/AA-30E is in the far left position of the same row. However, an RM-1 can fit into either of the two left positions of the row if the AA-30/AA-30E is in the far right position of that row. RM1ADP4a.cdr RM1ADP4.cdr Figure 5 RM-1 Installation Installation Steps: 1. Be sure all power is removed before installing the RM-1. 2. Attach wiring to the pluggable terminal blocks. Plug terminal blocks onto the RM-1 board. 2. Place the RM-1 onto the top and bottom studs of one of the positions on the ADP-4 dress panel. 3. Fasten with the standoffs provided. Document 51138:B 11/29/05 3

CONNECTIONS Connector To next RM-1 Compatible, Regulated, Power- Limited Power Supply UL/ULC- Listed for Fire Protective Signaling Use (See TB1- Power Supply Termination Points below) FORM-C Trouble Contacts FORM-C Contacts [ [ Earth DC Common THRU +24V THRU DC Common IN +24V IN Normally Open (closed in Trouble) Common Normally Closed (open in Trouble) Normally Open (closed when microphone is activated) Common Normally Closed (open when microphone is activated) Power ON LED Trouble LED LOW LEVEL AUDIO INPUT Twisted Shielded Cable to next amplifier or RM Twisted Shielded Cable from AMG Shield THRU - THRU + THRU Shield IN - IN + IN RM-1 LOW LEVEL AUDIO OUTPUT Twisted Shielded Cable Shield OUT - OUT + OUT Figure 6 Wiring TB1 - Power Supply Termination Points The RM1-SA must be powered through the FACP for which it is supplying audio. Power must come from the DVC when connected to the DVC, from the XPIQ-RMI when connected to the XPIQ, and from the MPS-24 when connected to the AMG. Power supplied must meet the following requirements: 20 ma primary, non-fire alarm current 66 ma when microphone is activated 20 ma secondary, non-fire alarm current. The secondary source for this power supply must be capable of supplying power for 24 hours or 60 hours (as required by NFPA-72) followed by 15 minutes of continuous microphone use. TB2 - Trouble Contacts These contacts transfer when trouble is detected; either when DC power has been removed or the microphone has been disconnected. The trouble contacts must be monitored by the FACP. Refer to the FACP manual for trouble contact monitoring information. TB3 - FORM-C Push-To-Talk Contacts Auxiliary contacts transfer when the microphone switch is pressed, and may be used to support ancillary functions. Do not exceed the contact ratings. All wiring must be installed in conduit and must remain within the room. TB4 - Low Level Audio IN and THRU TB4 is a dry contact relay: common, non-supervisd, with a contact rating of 2A, 30VDC. The recommended wiring is a 14-18 AWG twisted pair wiring. The cable from the DVC/AMG low level audio output is connected at the IN terminals of TB4. Cable connected to the THRU terminals passes the signal on to another, amplifiers, or back to the DVC or AMG (Class A wiring). Terminals on TB4 are not interrupted by use of the RM-1 microphone. Twisted shielded cable must be used for TB4 connections. TB5 - RM-1 OUTPUT TB5 is power-limited and supervised by its host, with an output signal strength of +12Vp-p maximum. The recommended wiring is a 14-18 AWG twisted pair wiring. Maximum impedance is 66 ohms. Distance is based upon impedance. The RM-1 output terminals provide the low level audio DVC/AMG signal from the LOW LEVEL AUDIO IN terminals unless the RM-1 microphone is activated by the push-to-talk button. When the microphone switch is pushed, the RM-1 microphone signal interrupts the signal from the LOW LEVEL AUDIO IN terminals and replaces it with the low level audio signal from the RM-1 microphone. Twisted shielded cable must be used for TB5 connections. LED 1 - This green LED will light when the RM-1 is powered. LED 2 - This yellow LED will light when the microphone is disconnected. RM1board.cdr 4 Document 51138:B 11/29/05

AMG-1 APPLICATIONS In these applications, the will normally require an annunciator programmed to activate the desired speaker zones. An announcement made through an microphone will be heard only when the speakers associated with the RM-1 output have been previously activated. Refer to the specific fire alarm control panel manual, voice alarm manual, transponder manual or annunciator manual applicable to your system for information on installing and mapping annunciators. Note that these applications do not apply to the DVC. Cascade Configuration #1 Note: Dotted lines indicate shielding in this figure. #2 AMG-1 Optional Class A return Class B wiring only #3 #1 AA-30 AA-30E AA-30 AA-30E #2 #3 To other AA-100/AA-100E AA-120/AA-120E RM1APP2.cdr Figure 7 RM-1 Series Application - Cascade Configuration Figure 7 illustrates a typical configuration where the low level audio source signal or the microphone signal is passed from one remote microphone to another through the audio amplifiers in between. In this configuration, when more than one remote microphone is in use at the same time, the microphone farthest from the AMG-1/AMG-1E has priority over any that are closer to the AMG-1/AMG-1E. For example, when microphone #3 is in use, its signal is sent to audio amplifier #3 and to any remote microphones and audio amplifiers that follow. Activating microphone #1 does not change this; microphone #1 does not override microphone #3. Document 51138:B 11/29/05 5

Branch Configuration To other RM-1 branch configurations Note: Dotted lines indicate shielding in this figure. BRANCH 2 Class B Only Supervised and Power Limited To other amplifiers Optional Class A Low Level Audio Return AA-30 AA-30E AA-100/AA-100E AA-120/AA-120E BRANCH 1 Class B Only Supervised and Power Limited Low Level Audio Riser To other amplifiers AA-30 AA-30E AA-100/AA-100E AA-120/AA-120E RM1APP1.cdr AMG-1 Figure 8 RM-1 Series Application, Branch Configuration Figure 8 illustrates a typical RM-1 Series configuration, with the low level audio source signal being passed from remote microphone to remote microphone using the LLA IN and THRU connections of TB4. Each then passes the low level audio source signal or the microphone signal on to audio amplifiers using the LLA OUT connections of TB5. In this configuration, the in Branch 1 communicates its microphone signal only to the audio amplifiers in Branch 1. A message generated through the microphone in Branch 1 will not be passed along to Branch 2 or any other branches. Likewise, the in Branch 2 will not communicate its microphone signal to Branch 1 or any other branches. 6 Document 51138:B 11/29/05

PTT Push-to-talk Switch Power Voltage Regulator Power ON LED Trouble LED Trouble Contacts (Normal state shown) PTT (Push-to-talk) (Inactive state shown) Low-level Audio IN and THRU Low-level Audio OUT RM1A.cdr Figure 9 Block Diagram Specifications: Power Requirements: 20 ma primary, non-fire alarm current 66 ma when microphone is activated 20 ma secondary, non-fire alarm current 17 V - 26.4 V Operating Voltage Relay Contact Ratings, Resistive Trouble Contacts Push-to-Talk Contacts 2 A 30 VDC 0.5 A 125 VAC 2 A 30 VDC 0.5 A 125 VAC Document 51138:B 11/29/05 7

Application Example Speaker Zone Wiring to Eliminate Acoustic Feedback Between RM-1 and Nearest Speakers. Decreasing acoustic coupling between microphone and speaker normally eliminates the acoustic feedback. This is done by locating the speaker away from microphone and/or selecting lower power tap on the speaker. In situations when these methods do not guarantee desirable results it may be necessary to disconnect local speaker(s) during local page by using PTT contacts on the RM-1. In order to do this follow these steps: 1. Create separate speaker zone for speaker(s) in the same location where RM-1(SA) is. 2. Connect speaker zone wiring as shown in Figure 10. Figure 10 Speaker Zone Wiring 8 Document 51138:B 11/29/05