FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

Similar documents
FT14 Ball Float Steam Trap (Screwed)

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

STEAM TRAPS

STEAM - WATER MIXERS ADCAMIX MX20

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

SECTION Pipeline Ancillaries

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

UNIVERSAL STYLE STEAM TRAPS WU450 Series

STEAM EQUIPMENT 4

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Liquid Drainers LIQUID DRAINERS

LIQUIDATOR 450 SERIES

THERMOSTATIC STEAM TRAPS

THERMODYNAMIC STEAM TRAP

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Brazed heat exchanger, XB

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

MFP14 Automatic pumps for condensate and other industrial fluids

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

The right trap for the right application.

1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Inverted bucket steam traps Type OKZ PN6/PN16

CD-33/CD-33S Controlled Disc Steam Traps

Model: 1100 Float-Controlled Condensate Trap, PN 25

TDS Conductivity Probe In-Line conductivity measurement

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

THERMODYNAMIC STEAM TRAPS

Why steam trap survey?

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Economical and simplified solutions that offer quality and optimum steam trap service.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

BK 46. Installation Instructions Steam Trap BK 46

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

Brazed heat exchanger XB

THE THERMOSTATIC STEAM TRAP

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

ESCO. Committed. Group of Companies. to help conserve Steam Energy

STAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012

Pump & Trap Combinations

Hydrocarbon & Chemical Processing Solutions

LIQUIDATOR UMT-TD Series Thermodynamic

BK 45 BK 45-U BK 45-LT BK 46

Hoffman Specialty General Catalog

Pekos Valves stocks on line

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

PCB-10 Condensate Recovery Systems

Installation and Maintenance Manual

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

INSTALLATION, OPERATION

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Steam Traps and Steam Trap Testing

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Temperature controller for steam (PN 25) AVT / VGS - external thread

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Level Electrode NRG Original Installation Instructions English

THERMODYNAMIC STEAM TRAPS

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Brazed heat exchanger, XB

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Inverted Bucket Steam Traps

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Pekos Valves stocks on line

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Operating and installation instructions

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

BOILER HOUSE PRODUCTS GMS

PIP PNE00004 Steam Trap Guidelines

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Installation and Maintenance "L" and "LS" Series

Our Know-How. Your Peace of Mind. Steam Solutions

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

GESTRA. Program for Universal Connections. The Smart Solutions

MFP14 Automatic pumps. for condensate and other industrial fluids

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Transcription:

LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Internal strainer Saturated and superheated steam. LT17-4,5, 10 and 14 DN ½ to DN1 DN15 to DN25 emale screwed ISO7/1 Rp (BS21) langed EN 1092-1/-2 PN16 or ANSI Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17-4,5 : 4,5 bar LT17-10 : 10 bar LT17-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. MODEL LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1,5 2 3 4,5 6 7 8 9 10 12 14 LT17-4,5 15-25 165 205 230 280 330 400 440 535 630 LT17-10 15-25 110 130 150 170 200 250 280 340 400 460 495 520 550 595 LT17-14 15-25 80 100 120 140 150 190 220 260 320 380 400 425 440 480 510 550 IS 1.335 E 12.07

DIMENSIONS (mm) Screwed EN PN16 ANSI 150 DN A B C D 15-1/2" 95 178 23 128 5,2 150 6,7 150 6,2 20-3/4" 95 178 23 128 5,2 150 7,2 150 6,4 25-1" 95 178 23 128 5,2 160 7,7 160 7,3 Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS-400-15 / 0.7040 2 Cover GJS-400-15 / 0.7040 3 *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / 1.4006 5 *Valve AISI 440C / 1.4125 6 *Lever AISI 304 / 1.4301 7 *loat AISI 304 / 1.4301 8 *Air vent Stainless st. (Bimetallic) 9 Bolts Steel 8.8 *Available spare parts. IS 1.335 E 12.07

LOAT AND THERMOSTATIC STEAM TRAPS LT 17 (DN 1 HC DN 25HC) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Internal strainer Saturated and superheated steam. LT17-4,5, 10 and 14 DN 1 HC DN25HC emale screwed ISO7/1 Rp (BS21) langed EN 1092-2 PN16 or ANSI Standard horizontal installation rom left to right LT17 (L-R) Upon request: -horizontal installation with the flow from right to left (R-L) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17HC-4,5 : 4,5 bar LT17HC-10 : 10 bar LT17HC-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. M ODEL S IZE LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1,5 2 3 4,5 6 7 8 9 10 12 14 LT17-4,5 1"-25HC 420 690 900 1070 1250 1450 1700 2010 2400 LT17-10 1"-25HC 360 405 450 530 620 790 880 1100 1250 1500 1600 1700 1750 1800 LT17-14 1"-25HC 270 310 340 395 435 530 600 610 850 990 1100 1190 1240 1300 1350 1380 IS 1.345 E 07.08

Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E G G 25-1" 120 195 80 190 110 9 160 248 11,3 160 248 10,9 On request can be supplied an alternative version DN 32-11/4" with different lengths: A = 190 and = 230 mm Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS-400-15 / 0.7040 2 Cover GJS-400-15 / 0.7040 3 *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / 1.4006 5 *Valve AISI 440C / 1.4125 6 *Lever AISI 304 / 1.4301 7 *loat AISI 304 / 1.4301 8 *Air vent Stainless st. (Bimetallic) 9 Bolts Steel 8.8 10 **Strainer AISI 304 / 1.4301 *Available spare parts ; ** Optional IS 1.345 E 07.08

LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 11/2 2 ; DN 40 50) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17-4,5, 10 and 14 DN11/2 - DN2 ; DN40 DN50 emale screwed ISO7/1 Rp (BS21) langed EN 1092-2 PN16 or ANSI INSTALLATION: Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17-4,5 : 4,5 bar LT17-10 : 10 bar LT17-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. IS 1.355 E 07.08

Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E B B 40-11/2" 210 248 79 208 131 16,9 230 248 20,3 230 248 19,1 50-2" 210 248 79 208 131 17,5 230 248 20,7 230 248 20,5 Vertical Installation (V) IS 1.355 E 07.08

LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 2 HC; DN 50 HC) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17-4,5, 10 and 14 DN2 HC ; DN50 HC emale screwed ISO7/1 Rp (BS21) langed EN 1092-2 PN16 or ANSI Standard horizontal installation rom right to left LT17 (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17HC-4,5 : 4,5 bar LT17HC-10 : 10 bar LT17HC-14: 14 bar CE MARKING (PED - European Directive 97/23/EC) PN 16 Category DN 50 HC 1 (CE Marked) PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. IS 1.533 E 06.10

Screwed DIMENSIONS (mm) EN PN16 ANSI 150 DN A B C D E G G 50-2" 300 250 126 266 140 21,6 230 325 27,8 230 325 27,6 Vertical Installation (V) IS 1.533 E 06.10

LOAT AND THERMOSTATIC STEAM TRAPS LT17LC (1/2-3/4 ; DN15-20) DESCRIPTION LT17LC float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation. MAIN EATURES Modulating discharge. Discharges condensate at steam temperature. Unaffected by sudden or wide load and pressure changes. Excellent air discharge (by thermostatic air vent). OPTIONS: USE: AVAILABLE MODELS: S: CONNECTIONS: INSTALLATION: SLR steam lock release Equalizing plug or vent connection Saturated and superheated steam. LT17LC-4,5, 10 and 14 DN ½ to DN3/4 DN15 to DN20 emale screwed ISO7/1 Rp (BS21) langed EN 1092-2 PN16 or ANSI Standard horizontal installation rom right to left LT17LC (R-L) Upon request: -horizontal installation with the flow from left to right (L-R) -vertical installation with the flow from top to bottom (V) MAX. DIERENTIAL PRESSURE LT17LC-4,5 : 4,5 bar LT17LC-10 : 10 bar LT17LC-14: 14 bar PN16* BODY LIMITING CONDITIONS ANSI 150 ** RELATED TEMP. 16 bar 15,4 bar 100 ºC 15,5 bar 14,6 bar 150 ºC 14,7 bar 13,8 bar 200 ºC 13,9 bar 12,1 bar 250 ºC PMO - Max. operating pressure 14 bar TMO - Max. operating temperature 198 ºC * According to EN1092-2:2000 ; ** Acc. to EN1759-1:2004 Body limiting conditions PN16 or below, depending on the type of connection adopted. Rating PN16 for thread. MODEL LOW RATE CAPACITY IN /h DIERENTIAL P RESSURE (bar) 0,1 0,3 0,5 0,7 1 1,5 2 3 4,5 6 7 8 9 10 12 14 LT17LC-4,5 15-20 120 180 200 240 280 320 360 400 495 LT17LC-10 15-20 55 90 110 130 140 175 190 230 280 300 330 350 390 405 LT17LC-14 15-20 40 60 70 90 100 120 140 155 190 210 220 225 230 260 280 300 IS 1.334 E 06.07

DIMENSIONS (mm) Screwed EN PN16 ANSI 150 DN A B C D 15-1/2" 95 160 23 100 3,5 150 5 150 4,5 20-3/4" 95 160 23 100 3,5 150 5,5 150 4,7 Vertical Installation (V) MATERIALS POS.Nr. DESIGNATION MATERIAL 1 Body GJS-400-15 / 0.7040 2 Cover GJS-400-15 / 0.7040 3 *Gasket Stainless st. / Graphite 4 *Seat AISI 410 / 1.4006 5 *Valve AISI 410 / 1.4006 6 *Lever AISI 304 / 1.4301 7 *loat AISI 304 / 1.4301 8 *Air vent Stainless st. (Bimetallic) 9 Bolts Steel 8.8 *Available spare parts. IS 1.334 E 06.07