TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Similar documents
TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Commercial and Light Industrial Fire Alarm Control Panel

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Conventional Releasing Control Panel

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

Specification/ Data Sheet

30.45 Electric Release PDRP-2001

DS7400Xi Addressable Control/ Communicator

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

TotalPac 3 Deluge, Electric release Self-contained system

FireNET Plus Wiring Instructions

LifeAlarm Fire Alarm Control Panels

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

TECHNICAL DATA. 319a. January 27, 2012

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Instructions for Installation, Operation, Care and Maintenance

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

FireFlex 1230 Self-contained system

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation, Operating and Maintenance Manual

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Release Control Fire Alarm Systems

Electric Release Panel Wiring Tips

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

AL800ULADA. NAC Power Extender. Installation Guide

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DIESEL Engine Fire Pump Controllers Features

good things in small packages

MR-2602 Two Zone Fire Alarm Control Panel

Variable Frequency Drive SERIES MP800 VFD

PSN-1000 & PSN 1000(E) Installation Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Notification Appliance Circuit Module

Across-the-Line SERIES MP300 Combined Manual and Automatic

AL600ULADA. NAC Power Extender. Installation Guide

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Model 17A00 Expansion Enclosure

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Installation Manual Premier 412/816/832. Issue 10

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Soft Start Series MP700 Solid State, Reduced Voltage

1935, Lionel-Bertrand Blvd. Boisbriand, Quebec, Canada J7H 1N8 Tel.: (450) Fax: (450) Toll Free: (866)

FireFlex DUAL Double Interlock, Self-contained system

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

TOTALPAC2 Integrated Fire Protection System

FMR Installation Instructions. Addressable Fire System Controller

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

The supplier and installer of the system should be approved by the local civil defence authority.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

P/N Product Manual. Conventional Fire Alarm/Suppression System

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

MPC-6000 / MPC-7000 / RND-2

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Excel-EN Conventional Fire Control Panel

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

FIRE DETECTION CONTROL PANEL OPERATING & MAINTENANCE MANUAL

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

AND ARCHITECT SPECIFICATIONS

Remote NAC Power Supply D7038

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

System 800 Addressable Fire Detection & Alarm System

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

Transcription:

January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems, MX-1230 Fire Extinguishing System, and MX-200 Fire Extinguishing System. The Model VFR400 is Underwriters Laboratory listed, FM Global approved and complies with UL Standard 864, Ninth Edition, for Local Control Units for Releasing Service. It is designed to be compatible and installed in accordance with the requirements of NFPA 13, NFPA 15, NFPA 16, NFPA 72, and NFPA 2001. The VFR400 is housed in a steel cabinet with removable door and key lock. Standard is red with black and white trim. The panel is available for use with either 120 VAC or 220 VAC for primary power. The cabinet will house up to two (2) 12AH standby batteries, which are capable of powering the unit in excess of 90 hours in the event of an AC power failure. For (2) 18AH batteries, a separate battery box (Part Number 09866) must be used.the VFR400 Release Control Panel can be used with a wide range of compatible initiating devices, such as spot heat detectors, smoke detectors, and linear heat detectors (10,000 ft. - SAFE-FIRE) or (3,500 ft. - Protectowire). A. Features Multi-Hazard Operation Supervised Microprocessor 32 Character Alpha-Numeric LCD Display Custom Banner Message Text Custom Zone Description Text On Board Menu Driven Programming Controls Releasing Circuits Protected from False Activation Four Class B Initiating Circuits Two Class B Supervisory Circuits** Four Class B Output Circuits Programmable Cross Zoning Continuous or Timed Discharge 40 Event History Buffer Walktest with Automatic Time-out Alarm, Trouble, Supervisory Waterflow Relays Optional Class A Output Zone Module 21 Standard Programs in Panel Memory Password Protection for all Programming 24 Hour Clock Supervised Remote Annunciator Output up to three (3) Auxiliary 24 VDC Power (Constant and Resettable) See Installation Manual 21 standard programs-program option for Viking Preaction, Deluge, Surefire Preaction and Firecycle Sprinkler Systems. **Can be used for Supervisory, Tamper, Low Air, High Air, or Abort Switch (Abort switch for MX-1230 or MX-200 Systems). 2. Listings and Approvals UL Listed: Meets UL Standard 864-9th Edition UL Listed: Clean Agent Extinguishing System Unit FM Approved: Deluge Systems, Preaction Systems, Multicycle Systems, Refrigerated Area Sprinkler Systems FM Approved: Control Panel Group 4 FM Approved: Clean Agent Extinguishing System Unit CE Certified 3. Technical Data Specifications: A. Environment Temperature: 32 F to 120 F (0 C to 48 C) Humidity: 93% non-condensing Scan with smart phone to access technical and troubleshooting resources. Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Form No. F_041307 Replaces page 290a-h, dated November 25, 2013. (Changed VK Clean Agent Systems to MX)

Release Control Panel 290b January 16, 2014 B. AC Power Universal Input 120VAC, (60 Hz, 165VA) or 220VAC, (50 Hz, 185VA) 15 Amp Branch Line overcurrent protection required. System trouble is generated if voltage drops below 102V. C. Visual Indicators: (Visible with door OPEN): 33 LEDs for common signal and zone annunciation 32 Character Alpha-Numeric Liquid Crystal Display (LCD) D. LCD: Displays prompts for programming system. Condition or status information is not shown. E. Control Buttons: Scroll Up, Buzzer Silence Signal Silence - Momentary, silences signaling circuits Buzzer Silence - Momentary, silences the trouble buzzer and outputs programmed as supervisory bell or trouble bell. System Reset - Momentary, resets all alarm circuits if condition has been corrected, removes power from initiating device circuits. Program Switch F. Initiating Device Circuits: 4 Class B (Class-A Module available) (all values nominal) Entire system is power limited, current limited to protect two wire detectors Capacity, two wire detectors (per zone) 25-0.1 ma type; or 20-0.12 ma type at 24 VDC Line resistance - 100 ohms max. (except with linear heat detection - max. 700 ohms) Override of signal silence for waterflow application, if desired End-of-Line Resistance - 5.1K ohms Normal standby current - approximately 4.0 ma Trouble-Low current - approximately 3.3 ma Alarm - approximately 10 ma Maximum Impedance for Alarm - 1400 ohms Ground also causes trouble and ground indicator to come on (no zone indication on ground) Ripple Voltage - 0.4VDC Max operating voltage range - 22.5 VDC to 25.9 VDC G. Output/Releasing Circuits: (All values nominal) The indicating circuits of the VFR-400 are Non-coded. This allows the use of visual and audible appliances on the same circuit. Notification Appliance Circuits (Class B), reverses polarity on alarm (optional Class A Module is available) Current limited 24VDC regulated, rated 1.0 Amp continuous max. (2.5 Amps total for all outputs combined Including Auxiliary Devices and RA-4410-RC) End-of-Line Resistance - 5.1K ohms Ripple Voltage - 0.3V For outputs programmed as RELEASING: maximum allowable line resistance = 1 divided by current draw of solenoid (In Release Mode - Requires End-of-Line diode assembly wired series for supervised circuit) All outputs are 24VDC, with range of 16VDC - 33VDC (Note: Release circuits kick out at <20 VDC) H. Dedicated Supervisory Initiating Circuit: Supervisory includes any of the following: Supervisory Tamper Low Air High Air Abort (MX-1230 and MX-200) One Class B/Initiating Device Circuit, latching Power limited End of Line resistance 5.1K ohms Resistance 100 ohms max. Increase in resistance causes supervisory trouble and system trouble Decrease in resistance causes supervisory signal Ripple Voltage - 0.1VDC I. Low/Missing Battery: Causes battery and system trouble if battery falls below 22 volts. Battery circuit is fused and reverse polarity protection is provided.

January 16, 2014 Release Control Panel 290c Material Standards: Enclosure Dimensions: 18.50 x 14.68 x 4.75 Finish: Red Baked Enamel Housing: 18 gauge steel Battery - Sealed Lead Acid Type Ordering Information: VFR400 Panel Part Number 14152 for Preaction Systems VFR400 Panel Part Number 14152-1 for Clean Agent Systems and Preaction Systems A. Modules and Accessories CA2Z MODULE (CLASS A INITIATING DEVICE CIRCUIT): (Viking Part Number 14155 - See Figure 5) Converts two Class B initiating device circuits to two Class A circuits. CAM2 MODULE (CLASS A INDICATING APPLIANCE CIRCUIT): (Viking Part Number 14156 - See Figure 6) Converts indicating appliance circuit from Class B to Class A. One model CAM (Class A Module) is required for each circuit. (DO NOT use this on an output programmed as TROUBLE BELL.) ARM-1/ARM-2 MODULE (AUXILIARY RELAY MODULE): (Viking Part Number 14157 - [Arm-1 is (4) Pole] and Viking Part Number 14158 [Arm-2 - is (2) Pole] - See Figures 7 & 8) Activated by 24VDC Indicating and/or Releasing, polarity reversing circuits. The module provides a non-supervised DPDT Relay that can be used for fan shutdown, door release, elevator recall, etc. RA-4410-RC (REMOTE ANNUNCIATOR): (Viking Part Number 14154 - See Figure 4) Connects to RS-485 & 24VDC terminals. Provides 33 LEDs for each zone in alarm supervisory, or trouble, each output activated or in trouble, AC power, Power trouble, System trouble, Ground fault, Supervisory, Supervisory trouble, Alarm, Alarm silence and Pre-discharge/Discharge. The annunciator also has a trouble buzzer and a lamp test / trouble silence switch. B. Additional Accessories and Relays MR-101/T SPDT Relay Module: (Viking Part Number 14159) MR-201 DPDT Relay Module: (Viking Part Number 14160) MR801/T SPDT Relay w/led Indicator: (Viking Part Number 14161) ELOD Resistor/Diode: (Viking Part Number 14162) ELOR Resistor: (Viking Part Number 14163) Trim Bezel for Panel: (Viking Part Number 14177 - See Figure 9) Batteries (2 required) 12VDC 8 AMP (Viking Part Number 07920) 12VDC 12 AMP (Viking Part Number 07921) 12VDC 18 AMP (Viking Part Number 09867) 4. Installation Refer to VFR400 Installation and operation Manual and Panel wiring diagrams for appropriate installation and programming requirements. All appropriate installation standards and buildings codes must be followed as required by the Authority Having Jurisdiction. 5. operation Refer to the appropriate Viking sprinkler system data sheets for sprinkler system operational information and proper wiring diagram and required program. 6. Inspection, Test and Maintenance Any system maintenance that involves placing a control valve or detection system out of service will impair the fire protection capabilities of that system. Prior to proceeding, appropriate impairment procedures per NFPA 25 shall be followed with the notification of all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected areas. Failure to follow these instructions could cause improper system operation, resulting in serious personal injury and/or property damage. The building owner is responsible for maintaining the fire protection system and devices in proper operating condition. The Viking VFR400 Release Control Panel must be kept free of foreign matter and environmental conditions that could impair its operation. Refer to VFR400 Installation and Operation Manual for appropriate testing procedures.

Release Control Panel 290d January 16, 2014 For minimum maintenance and inspection requirements, refer to NFPA 72 and NFPA 25. In addition the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. 7. AVAILABILITY & SERVICE The Viking VFR400 Multi-Hazard Release Control Panel is available through a network of domestic and international distributors. See the Viking web site or contact The Viking Corporation for the closest distributor. 8. GUARANTEES For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Figure 1 - Inside Panel Assembly Table 1 - Replacement Parts ITEM no. PART NUMBER DESCRIPTION no. req d. Notes 1 14153 Mother Board Assembly 1 Included 2 14163 5.1 KΩ End of Line Resistor 10 Included Not Shown 14162 End of Line Diode Assembly 2 Included 3 07920 12 VDC 8 Amp Battery 2 07921 12 VDC 12 Amp Battery 2 09867 12 VDC 18 Amp Battery 2 Two Batteries Required

January 16, 2014 Release Control Panel 290e Inside Panel Assembly Figure 2 VFR400 Dimensions Figure 3 RA-4410-RC (Remote Annunciator ) Viking Part Number 14154 Figure 4

Release Control Panel 290f January 16, 2014 CA2Z Module (Class A Initiating Device Circuit) Viking Part Number 14155 Figure 5 CAM2 Module (Class A Initiating Appliance Circuit) Viking Part Number 14156 Figure 6

January 16, 2014 Release Control Panel 290g ARM-1 Module (Auxiliary Relay Module) Viking Part Number 14157 Figure 7 ARM-2 Module (Auxiliary Relay Module) Viking Part Number 14158 Figure 8

Release Control Panel 290h January 16, 2014 Trim Bezel for Panel Viking Part Number 14177 Figure 9 Form No. F_041307 Replaces page 290a-h, dated November 25, 2013. (Changed VK Clean Agent Systems to MX)