RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Similar documents
RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

SIGMADEK, LTD. FIRE TEST REPORT

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

We Identify and S.T.O.P. Your Noise Problems

ENGINEERING EVALUATION

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Fire Performance of Translucent Systems

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

Refrigerating Appliance DOE Test Report

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

GUARDIAN FIRE TESTING LABORATORIES, INC.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Declaration of Conformity

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

BCTC CARPET TECHNICAL CENTRE

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Report of Surface Burning Characteristics Test on Acoustical Panel

Refrigerating Appliance ErP Test Report

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

Abrasion Resistance of Fluoropolymer and polyester Coatings

Materials Testing by Gregory Havel

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

Acoustical Surfaces, Inc.

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

Classification of Fire Performance of Wall and Ceiling Lining Materials

Review Fire Test Report

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

FLASHLIGHT ANSI STANDARDS

BS EN : 2001 & IEC :2000

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

NF X : Parts 1, 2, 3, 4 & 5

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly


BS EN ISO : 2010

Food Service Technology Center

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

Southern California Gas Company Customer Programs Department

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Public Comment No. 2-NFPA [ Section No ]

SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 *

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61(67): Annex 1: Part 2

This document is a preview generated by EVS

Test Report. Appliance EMF Testing

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Transcription:

REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A. Via Ghiarola Nuova 258 41042-Fiorano Modenese Italy PRODUCT EVALUATED: Laminam 3+ Porcelain Tile with Fibreglass Backing EVALUATION PROPERTY: Surface Burning Characteristics Report of testing Laminam 3+ porcelain tile with fibreglass backing for compliance with the applicable requirements of the following criteria: ASTM E84-12a, Standard Test Method for Surface Burning Characteristics of Materials This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 1

Report No. 100900037COQ-002 Page 2 of 12 1 Table of Contents PAGE 1 Table of Contents... 2 2 Introduction... 3 3 Test Samples... 3 3.1 SAMPLE SELECTION... 3 3.2 SAMPLE AND ASSEMBLY DESCRIPTION... 3 4 Testing and Evaluation Methods... 4 4.1 TEST STANDARD... 4 5 Testing and Evaluation Results... 5 5.1 RESULTS AND OBSERVATIONS... 5 6 Conclusion... 6 APPENDIX A Data Sheets...4 Pages REVISION SUMMARY

Report No. 100900037COQ-002 Page 3 of 12 2 Introduction Intertek Testing Services NA Ltd. (Intertek) has conducted testing for Laminam S.P.A. to evaluate the surface burning characteristics of Laminam 3+ porcelain tile with fibreglass backing. Testing was conducted in accordance with the standard methods of ASTM E84-12a, Standard Test Method for Surface Burning Characteristics of Materials. This evaluation began October 9, 2012 and was completed the same day. 3 Test Samples 3.1. SAMPLE SELECTION Samples were submitted to Intertek directly from the client and were not independently selected for testing. The sample materials were received at the Evaluation Center on September 18, 2012. 3.2. SAMPLE AND ASSEMBLY DESCRIPTION Upon receipt of the samples at the Intertek Coquitlam laboratory, they were placed in a conditioning room where they remained in an atmosphere of 23 3 C (73.4 5 F) and 50 5% relative humidity. The sample material was described by the client as 3mm thick Grés porcelain with a 0.4mm thick fiberglass backing, and was identified as Laminam 3+. The tiles measured 24 in. wide by 5 ft. and 10 ft. lengths and had a light brown coloured porcelain face. For each trial run, two 10 ft. long and one 5 ft. long by 24 in. wide sample tiles were butted together and placed on the upper ledge of the flame spread tunnel to form the required 24 ft. sample length, with the porcelain face oriented toward the flame. A layer of 6 mm reinforced cement board was placed over top of the samples, the tunnel lid was lowered into place, and the samples were then tested in accordance with ASTM E84-12a.

Report No. 100900037COQ-002 Page 4 of 12 4 Testing and Evaluation Methods 4.1. TEST STANDARD The results of the tests are expressed by indexes, which compare the characteristics of the sample under tests relative to that of select grade red oak flooring and inorganic-cement board. (A) Flame Spread Classification: This index relates to the rate of progression of a flame along a sample in the 25 foot tunnel. A natural gas flame is applied to the front of the sample at the start of the test and drawn along the sample by a draft kept constant for the duration of the test. An observer notes the progression of the flame front relative to time. The test apparatus is calibrated such that the flame front for red oak flooring passes out the end of the tunnel in five minutes, thirty seconds (plus or minus 15 seconds). (B) Smoke Developed: A photocell is used to measure the amount of light, which is obscured by the smoke passing down the tunnel duct. When the smoke from a burning sample obscures the light beam, the output from the photocell decreases. This decrease with time is recorded and compared to the results obtained for red oak, which is defined to be 100.

Report No. 100900037COQ-002 Page 5 of 12 5 Testing and Evaluation Results 5.1. RESULTS AND OBSERVATIONS (A) Flame Spread The resultant flame spread classifications are as follows: (Classification rounded to nearest 5) Laminam 3+ Porcelain Tile with Fibreglass Backing Flame Spread Flame Spread Classification Run 1 2 0 Run 2 0 0 (B) Smoke Developed The areas beneath the smoke developed curve and the related classifications are as follows: (For smoke developed indexes 200 or more, classification is rounded to the nearest 50. For smoke developed indexes less than 200, classification is rounded to nearest 5) Laminam 3+ Porcelain Tile with Fibreglass Backing Smoke Developed Smoked Developed Classification Run 1 14 15 Run 2 14 15 (C) Observations Surface ignition occurred at 223 and 250 seconds.

Report No. 100900037COQ-002 Page 6 of 12 6 Conclusion The Laminam 3+ porcelain tile with fibreglass backing, submitted by Laminam S.P.A., exhibited the following flame spread characteristics when tested in accordance with ASTM E84-12a, Standard Test Method for Surface Burning Characteristics of Materials. Laminam 3+ Porcelain Tile with Fibreglass Backing Flame Spread Classification Smoked Developed Classification Run 1 0 15 Run 2 0 15 The conclusions of this test report may not be used as part of the requirements for Intertek product certification. Authority to Mark must be issued for a product to become certified. INTERTEK TESTING SERVICES NA LTD. Tested and Reported by: Greg Philp Technician Building Products Reviewed by: Kal Kooner, P.Eng. Manager Building Products

Report No. 100900037COQ-002 Page 7 of 12 APPENDIX A DATA SHEETS

Report No. 100900037COQ-002 Page 8 of 12 ASTM E84-12a DATA SHEETS Run 1

Report No. 100900037COQ-002 Page 9 of 12 ASTM E84-12a DATA SHEETS Run 1

Report No. 100900037COQ-002 Page 10 of 12 ASTM E84-12a DATA SHEETS Run 2

Report No. 100900037COQ-002 Page 11 of 12 ASTM E84-12a DATA SHEETS Run 2

Report No. 100900037COQ-002 Page 12 of 12 REVISION SUMMARY DATE PAGE(S) SUMMARY October 10, 2012 All Original Issue Date