HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Similar documents
Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

For Heavy Duty Commercial and Industrial Environments

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Operating Instructions

DTS Light fittings for explosive atmospheres

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

LED FLOOD LIGHT SOLUTIONS Harsh and Hazardous Products

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

INTRINSICALLY SAFE LIGHTING RANGE

High bay LED lighting fixture

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Ex LED light fittings

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Dräger Polytron 5720 IR Detection of carbon dioxide

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Illumination unit For sight glass level indicator Model LGI

ELECTRICAL EX EQUIPMENT

Dräger Polytron 5720 IR Toxic Gas Detection

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

XLFE-4/1. Borosilicate glass globe

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Dräger Polytron 8310 Stationary gas detector (DSIR)

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ASPECT VISION DELIVERED

IECEx Certificate of Conformity

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Manual Power relay SR853

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Manual Alarm Call Points

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Drive systems for the chemical, oil and gas industry. Electric drives and systems

XEON. High impact resistant body and PC cover. Double layer coating. through wiring. Build-in microwave sensor.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Certification Supplement Manual

D O M E S T I C LED. Lighting C O M M E R C I A L

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

Integrated Solutions Low Voltage Systems

Hazardous Area Products

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

3M Oldham OLCT 100. Description. Fixed Gas Detector

INSTRUCTION & SERVICE MANUAL

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Industrial Hazardous Area Products

Ex Mark:Ex d eb ⅡB T6 Gb

Dräger Polytron 8200 Stationary gas detector (CatEx)

Flow LED robust and streamlined

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Our LED highlights. LED Ex Luminaire 4200, LED Floodlight 5000, LED Multi-Purpose Luminaire 4000

Hazardous Area Portable Fan Heater The Bulldog

Dialight. DuroSite LED Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

Dräger QuadGard Control System

LED Lighting Solutions Engineered for Demanding Environments Appleton LED Luminaires

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

DB4 Range - SPEAKERS - Up to 25 Watts

Dräger Polytron 8100 EC Detection of toxic gases and vapors

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Industrial & Hazardous Area Electrical Equipment

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

A TRADITION OF TRUST.

Earth-Rite II PLUS Static Earthing System

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

CoreLine Waterproof the clear choice for LED

CLEAN ROOM MEDICAL LUMINAIRE

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

A UTO D EALERSHIP L IGHTING

OLC(T) 100 FIXED GAS DETECTOR

ATM Lighting sp. z o.o

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Certification Supplement Manual

Dräger Polytron 8000 Stationary gas detector (EC)

Gas cylinder scale Model GCS-1

INNOVATIVE THINKING HAS MADE US AN INDUSTRY LEADER.

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

ATM Lighting sp. z o.o

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Guide for hazardous areas

Transcription:

HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com

Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting edge lighting solutions to hazardous and marine markets. We understand the unique characteristics of LED technology and have a proven track record, pioneering the world s first Zone 1 LED luminaire; the NexLED back in 2005. As a business we have invested in the development of solid state lighting technologies to provide solutions that meet the exacting requirements of the Oil, Gas & Petrochemical industries. The result is a proven, reliable and complete range of LED luminaires that compliment and enhance our fluorescent and HID products. At the heart of each new design is our underlying philosophy - Quality, Reliability and Low Maintenance. Made in Britain Chalmit products are designed and manufactured in the UK. We are proud to endorse and sustain a great tradition in engineering and innovation.

LED LIGHTING The future of hazardous area lighting is back... HDL106 Newly re-certified and re-tested. When the HDL106 was introduced by Hadar in 2009 it was hailed the future of hazardous area lighting due to its weight and power savings. Well now it s back, together with the added bonus of Chalmit s reputation for quality, reliability and safety. LED technology has revolutionised the market allowing up to 50% power savings compared against conventional HID luminaires. These power saving increase the lifespan of the HDL106 too, it could last over 10 years, even if it was on for 24 hours a day. That s a whopping 87,600 hours of light! The HDL106N has been fitted with a new diffuser, ensuring that impact and IP requirements are satisfied throughout the range. Rigorous in-house and third party testing ensures that each luminaire not only meets, but exceeds Hubbell s, the CSA s and our customers expectations. Find Out More Contact Ken Eddleston, Chalmit Lighting Product Manager E: keddleston@hubbell-scotland.com T: +44 (0)141 810 9668 3

ZONE 1/21 LED LIGHTING HDL106N Ex e LED Floodlight The HDL106N is a lightweight and compact Zone 1 floodlight which can be interlinked to provide an effective LED alternative to traditional HID floodlights, up to 250W. With a variety of beam options, extensive ambient range and marine grade construction, this is a global lighting solution to suit any harsh and hazardous application. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDL106N Ex e LED Floodlight Type of Protection ATEX Classification Ex e mb (Increased Safety, Encapsulation) Ex tb (Dust Protected Enclosure) Group II Category 2 GD Area Classification Zone 1 and Zone 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 Certificate Coding Ambient C Enclosure Entry Termination Installation Control Gear Colour Temperature (CCT) Maintenance Ingress Protection Surge Protection Electrical Supply EC Type Examination Certificate - Sira 09ATEX5159X IECEx Certificate of Conformity - IECEx SIR 09.0064X Ex e mb IIC T4/T3 Gb Ex tb IIIC T103 C Db -20 to +50 (T4) / +59.5 (T3) LM6 Aluminium with epoxy powder finish (RAL 7035), and Polycarbonate diffuser 2 x M20 cable entries 3 core 4mm² max. conductor with looping Stirrup mounting bracket Electronic Driver M8 Hex Head and M6 SKT Head IP66/67 4kV line to line, 6kV line to earth Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (6kg per module) lighting solution 4

HDL106N ZONE1/21 HDL 106N Version Voltage Beam Pattern Mount Light (CCT) Cable Entries Other Options 0 24 LEDs N Narrow W Cool White (5700K) 04 RAL 7035 (Grey) 1 48 LEDs M Medium X Warm White (3000K) FG Glass front cover 2 96 LEDs W Wide 3 144 LEDs 4 192 LEDs X Extra Wide 0 M20 5 M25 H 100-254V AC L 18-54V AC/DC* H Horizontal Mount [single unit] V Vertical Mount [multiple units] C Ceiling Mount *Upper ambient becomes +55 C Typical ordering reference: HDL106N1HWHW004 250 135 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 5

ZONE 1/21 LED LIGHTING HDL106NE Ex e LED Floodlight The HDL106NE is a distinctive Emergency LED luminaire allowing up to four modules interlinked, providing an effective and efficient alternative to traditional battery-backed luminaires. With a variety of beam options available, and integral battery backup allowing for either 90 minutes or 3 hours battery duration, this is a flexible solution for any Emergency or Escape to Sea application. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDL106NE Ex e LED Floodlight Type of Protection ATEX Classification Ex e mb (Increased Safety, Encapsulation) Ex tb (Dust Protected Enclosure) Group II Category 2 GD Area Classification Zone 1 and Zone 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 Certificate Coding EC Type Examination Certificate - Sira 09ATEX5159X IECEx Certificate of Conformity - IECEx SIR 09.0064X Ex e mb IIC T4 Gb Ex tb IIIC T103 C Db Ambient C -20 to +50 Enclosure Entry Termination Installation Control Gear Colour Temperature (CCT) Maintenance LM6 Aluminium with epoxy powder finish (RAL 7035), and Polycarbonate diffuser 2 x M20 cable entries 4 core 4mm² max. conductor with looping Stirrup mounting bracket Electronic Driver M8 Hex Head and M6 SKT Head Emergency Duration 90mins (100%) or 3hrs (50%) Ingress Protection Surge Protection Electrical Supply IP66/67 4kV line to line, 6kV line to earth 100-254V AC 50/60Hz Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (9kg per module) Emergency lighting solution 6

HDL106NE ZONE1/21 HDL 106N Version* Beam Pattern Light (CCT) Cable Entries Other Options E EM (48 LEDs) N Narrow W Cool White (5700K) 0 M20 04 RAL 7035 (Grey) ES EM/Std (96 LEDs) M Medium X Warm White (3000K) 5 M25 FG Glass front cover SES Std/EM/Std (144 LEDs) W Wide X Extra Wide *For alternative arrangements please contact Chalmit Internal Sales. Typical ordering reference: HDL106NESWX004 250 205 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 7

ZONE 2/22 LED LIGHTING HDL206N Ex e LED Floodlight The HDL206N is an outstanding luminaire allowing up to four modules interlinked, providing an effective and efficient replacement for conventional high power HID floodlights, up to 250W. With multiple beam options available, and a wide ambient range, this is a truly universal solution for all Zone 2 applications. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDL206N Ex e LED Floodlight Type of Protection ATEX Classification Ex e mb (Increased Safety, Encapsulation) Ex tb (Dust Protected Enclosure) Group II Category 3 GD Area Classification Zone 2 and Zone 22 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 Certificate Coding Ambient C Enclosure Entry Termination Installation Control Gear Colour Temperature (CCT) Maintenance Ingress Protection Surge Protection Electrical Supply EC Type Examination Certificate - Sira 11ATEX4314X Ex e mb IIC T4/T3 Gc Ex tb IIIC T103 C Dc -20 to +50 (T4) / +59.5 (T3) LM6 Aluminium with epoxy powder finish (RAL 7035), and Polycarbonate diffuser 2 x M20 cable entries 3 core 4mm² max. conductor with looping Stirrup mounting bracket Electronic Driver M8 Hex Head and M6 SKT Head IP66/67 4kV line to line, 6kV line to earth Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (6kg per module) lighting solution 8

HDL206N ZONE 2/22 HDL 206N Version Voltage Beam Pattern Mount Light (CCT) Cable Entries Other Options 0 24 LEDs N Narrow W Cool White (5700K) 04 RAL 7035 (Grey) 1 48 LEDs M Medium X Warm White (3000K) FG Glass front cover 2 96 LEDs W Wide 3 144 LEDs 4 192 LEDs X Extra Wide 0 M20 5 M25 H 100-254V AC L 18-54V AC/DC* H Horizontal Mount [single unit] V Vertical Mount [multiple units] C Ceiling Mount *Upper ambient becomes +55 C Typical ordering reference: HDL206N1HWHW004 250 135 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 9

ZONE 2/22 LED LIGHTING HDL206NE Ex e LED Floodlight The HDL206NE is a compact Emergency LED luminaire allowing up to four modules interlinked, providing an effective and efficient replacement to traditional battery-backed luminaires. With its lightweight construction, and variety of beam options already available, the addition of an integral battery makes this is a global solution for any Zone 2 application. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDL206NE Ex e LED Floodlight Type of Protection ATEX Classification Ex e mb (Increased Safety, Encapsulation) Ex tb (Dust Protected Enclosure) Group II Category 3 GD Area Classification Zone 2 and Zone 22 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 Certificate Coding EC Type Examination Certificate Sira 11ATEX4314X Ex e mb IIC T4/T3 Gc Ex tb IIIC T103 C Dc Ambient C -20 to +50 Enclosure Entry Termination Installation Control Gear Colour Temperature (CCT) Maintenance Ingress Protection Surge Protection Electrical Supply Aluminium Alloy with epoxy powder finish 2 x M20 cable entries 3 core 4mm² max. conductor with looping Stirrup mounting bracket Electronic Driver M8 Hex Head and M6 SKT Head IP66/67 4kV line to line, 6kV line to earth Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (9kg per module) Emergency lighting solution 10

HDL206NE ZONE 2/22 HDL 206NE Version* Beam Pattern Light (CCT) Cable Entries Other Options E EM (48 LEDs) N Narrow W Cool White (5700K) 0 M20 04 RAL 7035 (Grey) ES EM/Std (96 LEDs) M Medium X Warm White (3000K) 5 M25 FG Glass front cover SES Std/EM/Std (144 LEDs) W Wide X Extra Wide *For alternative arrangements please contact Chalmit Internal Sales. Typical ordering reference: HDN106NEMW004 250 205 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 11

INDUSTRIAL SAFE AREA LED LIGHTING HDN106N LED Floodlight The HDN106N is an outstanding luminaire, with a variety of beam options to suit any industrial application. Up to four modules can be interlinked to increase the output without impacting on the product performance, and provide an effective replacement for conventional HID floodlights, up to 250W. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDN106N LED Floodlight Ambient C -20 to +55 Enclosure LM6 Aluminium with epoxy powder finish (RAL 7035), and Polycarbonate diffuser Entry 2 x M20 cable entries Termination 3 core 4mm² max. conductor with looping Installation Stirrup mounting bracket Control Gear Electronic Driver Colour Temperature (CCT) Maintenance M8 Hex Head and M6 SKT Head Ingress Protection IP66/67 Surge Protection 4kV line to line, 6kV line to earth Electrical Supply Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (6kg per module) lighting solution 12

HDN106N INDUSTRIAL SAFE AREA HDN 106N Version Voltage Beam Pattern Mount Light (CCT) Cable Entries Other Options 0 24 LEDs N Narrow W Cool White (5700K) 04 RAL 7035 (Grey) 1 48 LEDs M Medium X Warm White (3000K) FG Glass front cover 2 96 LEDs W Wide 3 144 LEDs 4 192 LEDs X Extra Wide 0 M20 5 M25 H 100-254V AC L 18-54V AC/DC H Horizontal Mount [single unit] V Vertical Mount [multiple units] C Ceiling Mount Typical ordering reference: HDN106N1HWHW004 250 135 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 13

INDUSTRIAL SAFE AREA LED LIGHTING HDN106NE LED Floodlight The HDN106NE is a distinctive Emergency LED luminaire allowing up to four modules interlinked, providing an effective and efficient replacement to traditional battery-backed luminaires. With a wide ambient range and multiple beam options available, this is a truly global industrial solution for any application where Emergency lighting is required for a period of 90mins or 3hrs. MADE IN BRITAIN International Approvals Mounting Options Floodlight. Pendant. Bulkhead. High Bay. Pole/Column. Road Lighting. Standard Specification HDN106NE LED Floodlight Ambient C -20 to +55 Enclosure LM6 Aluminium with epoxy powder finish (RAL 7035), and Polycarbonate diffuser Entry 2 x M20 cable entries Termination 3 core 4mm² max. conductor with looping Installation Stirrup mounting bracket Control Gear Electronic Driver Colour Temperature (CCT) Maintenance M8 Hex Head and M6 SKT Head Ingress Protection IP66/67 Surge Protection 4kV line to line, 6kV line to earth Electrical Supply Features Instant on crisp white light output Highly Energy Efficient Modular design allowing up to four interlinked luminaires, each providing a delivered output > 5000lm 80,000 maintenance free hours at 25 C Lower power consumption than HID lamps Lightweight (9kg per module) lighting solution 14

HDN106NE INDUSTRIAL SAFE AREA HDN 106N Version* Beam Pattern Light (CCT) Cable Entries Other Options E EM (48 LEDs) N Narrow W Cool White (5700K) 0 M20 04 RAL 7035 (Grey) ES EM/Std (96 LEDs) M Medium X Warm White (3000K) 5 M25 FG Glass front cover SES Std/EM/Std (144 LEDs) W Wide X Extra Wide *For alternative arrangements please contact Chalmit Internal Sales. Typical ordering reference: HDN206NEMW004 250 205 175 306 180 50 50 30 100 265 Product design and specifications are subject to change without notice. Please check the Chalmit website for latest specifications. www.chalmit.com 15

Hubbell Harsh & Hazardous Extreme environments demand superior performance, which is why you will find Hubbell products and systems installed in some of the most arduous and safety critical locations worldwide. The Hubbell Harsh & Hazardous group combines dedicated, market leading brands within the Hubbell portfolio to provide a complete package for companies operating in some of the toughest environments on the planet. We are committed to providing quality products and services that will meet and exceed your expectations. Our principal activities include the design and manufacture of rugged and hard wearing products. These include telephones and communication products, lighting, control gear and electrical connection products, all designed to operate primarily in extreme outdoor, hazardous and corrosive areas. Our Brands All of our brands are long established and well respected businesses within each of their industries. Our primary industry sectors include: Oil & Gas, Petrochemical, Industrial, Marine, Military, Transport and Commercial. Corporate Information Hubbell Incorporated HQ is based in Connecticut, U.S.A. and you can find out more information about the Hubbell Group on our corporate website at www.hubbell.com 16

Contact Details United Kingdom Chalmit PO Box 5575 Glasgow G52 9AP UK Tel: +44 (0) 141 882 5555 Fax: +44 (0) 141 883 3704 Email: info@chalmit.com Middle East Building No. 5EA Office No. G03 Dubai Airport Free Zone (DAFZ) PO Box 23529 Dubai UAE Tel: +971 (0)4 609 1222 Email: middle-east@chalmit.com Asia Pacific 130 Joo Seng Road #03-02 Olivine Building Singapore 368357 Tel: +65 6282 2242 Fax: +65 6284 4244 Email: asia-pacific@chalmit.com Korea 512 Hyosung Intellian 681-3 Deungchon Dong Kangseo-Ku Seoul 157-030 Korea Tel: +82 2 2063 3719 Fax: +82 2 2603 7386 Mob: +82 10 9977 6349 Email: korea@chalmit.com China Room H/I 18F No. 728 Pudong Avenue Shanghai International Ocean and Finance Building Shanghai 200120 P.R. China Tel: (86 21) 3392 6550 ext. 318 Fax: (86 21) 3392 6551 Mob: +(86 139) 1829 4175 6349 Email: china@chalmit.com www.chalmit.com CH_HDL106_V1_DECEMBER 2017