SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Similar documents
SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Installation and Maintenance "L" and "LS" Series

Installation and Testing of Inverted Bucket Steam Traps Manual

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Clean Steam Generators

INSTRUCTION MANUAL HS-229G

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

TITAN FLOW CONTROL, INC.

Rada 25R Installation and Maintenance

Design Criteria. Installation

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

TORRID MARINE YACHT QUALITY Since Owner s Manual

Rada 320R Installation and Maintenance

Inverted Bucket Steam Traps

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

Air Pump Up to 800 gallons

Intelligent System Solutions Steam Air Hot Water

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Pressurized Filter Up to 1250 gallons

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Sound Cover [ , , , ]

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

TrueClean ToteCleaner

CD6102 / CD6102 OC / CD6102-2

Service Parts, Kits and Accessories

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

MaxLite LED MICRO-T PANEL

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

INSTALLATION ADJUSTMENT SERVICE

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer

INTERMEDIATE GUIDE BRACKET

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

OPERATIONS MAINTENANCE MANUAL

FLCH4R Garage and Utility Electric Heater

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ion Genesis Pump Controller

Thin Window FAN With Comfort Control Thermostat. Instruction Leaflet. pure indoor living MODEL: BWF0522M-CN

THE THERMOSTATIC STEAM TRAP

INSTRUCTION MANUAL HS-208REVI

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

AeroVent 3X Product Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

MN908 No. 282C Replaces 282B LB7013

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Instruction Leaflet. Read instructions before operating. Retain for future reference.

HotPoly Tote Tank / IBC Heaters (TTH Series)

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS FS SERIES. QuickTrap FS3/FS5/FS5H.

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Duct Mount. Installation Instructions

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

LS205EB INSTALLATION/OWNERS MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

TrueClean ToteCleaner

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

Model OP155 Air Dryer

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

Inline Heater for Solvent or Gas. Installation and Operation Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

Table of Contents Welcome and Thank You Note:

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Corrosion Resistant Fluid and Air Handling Systems.

Expanded Backup Control Installation & Operator s Instruction Manual

Horizontal Bottle Cooler Installation and Operation Manual

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Transcription:

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual 111-EN SH-300 SH-900 SH-1500 SH-1600 SH-1700

Table of Content. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 7 Troubleshooting. 8 Repair Procedure. 9 Warranty Terms 10 2

General Safety Information Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the Armstrong SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Traps. Selection or installation of equipment should always be accompanied by competent technical assistance. We encourage you to contact Armstrong International or your local representative if further information is required. 2017 Armstrong International, Inc. Designs, materials, weights and performance ratings are approximate and subject to change without notice. 3

Product Information 1. Product Information: Bimetallic type steam traps employ the temperature effect of a thermostatic bimetallic element. At start up, the steam traps have the ability to handle large condensate loads while the system is heating up. At this point the bimetallic element is contracted and the valve is fully open removing condensate and non-condensable gases from the system. When the system reaches steam temperature, the high temperature causes the bimetallic element to expand, pulling the valve stem to close the valve. The valve remains closed until enough condensate backs up cooling the bimetallic element. As the bimetallic element cools, the valve slightly opens to pass condensate and vent non-condensable gases. When steam temperature is achieved, the valve closes again. 4

Product Installation 2. Installing a SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Before installation, verify that the maximum allowable pressure/temperature and maximum operating pressure of the trap are sufficient to handle the system design pressure and temperature. This information can be found on the label located on the trap. Steam trap installation is critical from both a performance and maintenance aspect. Installation of the trap is simplified if you follow these guidelines. 1. Before installing the trap, ensure the line is clean. Blow down any strainers ahead of the trap. 2. Install the trap so that it is accessible for inspection and repair, below the drip point and close to the vertical drip leg. 3. For proper operation the trap should be installed in the horizontal line with the domed cap in the up position. 4. What little condensate there is on superheat and high pressure/low load service usually forms in drip legs and in the trap themselves. Therefore, proper piping and drip legs of adequate size and diameter are essential for the successful operation of the Armstrong bimetallic traps, see Chart 2.1 and Figure 2.1. 5. Isolation valves are needed before and after traps. When starting a new trap, be sure to open the valve slowly. 6. Due to the high temperatures of steam, it might be necessary to guard the traps for personnel safety. 7. See Figures 2.1 and 2.2 for complete installation following the above guidelines. Steam Main Drip Leg Wrongly Sized Correctly Sized Figure 2.1 Strainer Table 2.1 Drip leg same as the header diameter up to 4''(100 mm). Above 4''(100 mm), 1/2 header size, but never less than 4'' (100 mm). Drip leg drain valve Figure 2.2 5

2.1. Disassemble/Assemble Procedure for Welding SH-300, SH-900, SH-1500, SH-1600 and SH-1700 If post weld heat treat is required by customers weld procedure. 1. Remove 4 flange bolts and cap. 2. Remove bimetallic element assembly using a 1 (38 mm) open end wrench on hex below the bimetallic elements. 3. Preheat, weld and post weld heat treat per customers weld procedure. 4. Clean gasket surfaces and replace gasket with a new one. 5. Replace bimetallic element assembly using the 1 (38 mm) open end wrench. Torque to 100 to 125 ft-lbs., [136 to 170 Nm]. 6. Replace cap and flange bolts 7. Torque the flange bolts with a 3 or 4 step crisscross pattern to 280 ft-lbs., [380 Nm] for the SH-1500, SH-1600 & SH-1700 and to 90 ft-lbs., [122 Nm] for the SH-900. 6

Service and Maintenance 3. Service and Maintenance Bimetallic type steam traps should be tested at least three times per year. When the bimetallic steam trap is suspected of malfunctioning, it can be checked by observing the discharge of the trap. Normal trap operation would be indicated by: Trap discharging condensate continuously (modulating) Trap discharge in cycles (on-off) All discharges are accompanied by large amounts of flash steam. Do not confuse the discharge of flash steam with live steam loss. If the trap continues to blow live steam, isolate the trap and repair or replace. See disassembly/assembly procedure in Product Installation section for repair. 7

Troubleshooting 4. Troubleshooting Whenever a trap fails to operate and the reason is not readily apparent, the discharge from the trap should be observed. If the trap is installed with a test outlet or discharges to atmosphere, this will be a simple matter - otherwise, it will be necessary to break the discharge connection. 4.1. Cold Trap - No Discharge No condensate or steam coming to trap. Stopped or plugged strainer ahead of trap Broken valve in line to trap Pipeline or elbows plugged Pressure reducing valve out of order Isolation valves are off/closed Caution: Superheated steam is invisible. Do not place objects directly in the path of trap discharge. In a blow through situation a loud roar should be heard even though there may not be visible steam 4.2. Steam Loss If the trap leaks or blows live steam, trouble may be due to any of the following causes: Valve may fail to seat Piece of scale lodged in orifice Worn parts Perceived Troubles: If it appears that steam escapes every time trap discharges, remember that hot condensate forms flash steam when released to lower pressure, but usually condenses quickly in the return line. 4.3. Continuous Flow Trap not up to temperature. Allow more time for condensate removal (on start-up) On large loads the traps is working fine as designed. 8

Repair Procedure 5. Repair of SH-300, SH-900, SH-1500, SH-1600 and SH-1700 5.1. TRAP Caution: Superheat steam is invisible. Take extra precaution while inspecting traps. Caution: Superheat steam is invisible. Take extra precaution while inspecting traps. Isolate the trap Blowdown/bleed off the internal pressure Unbolt and remove the cap Place 1 (38 mm) open end wrench on the hex below the elements and unscrew the assembly Remove the old gasket from the body and cap seating surface Clean or replace the screen Install a new gasket on the body seating surface Install screen Replace the element assembly using a 1 (38 mm) open end wrench on the hex surface. Torque to 100 125 ft-lbs., [136 to 170 Nm]. Reassemble the cap into the body seating surface recess Reassemble bolts and nuts Torque the flange bolts with a 3 or 4 step crisscross pattern to 280 ft-lbs., [380 Nm] for the SH-1500, SH-1600 & SH-1700 and to 90 ft-lbs., [122 Nm] for the SH-900. When starting a trap, be sure to open the isolation valves slowly and check for gasket leaks. 5.2. Repair Parts Cap Body Element Screen Gasket Bolt Set CAP ELEMENT GASKET BOLT SET SCREEN INLET OUTLET BODY Figure 5.1 Repair parts for SH-300/SH-900/ SH-1500/SH-1600/SH-1700 9

Limited Warranty and Remedy 6. Warranty Terms Armstrong International, Inc. or the Armstrong division that sold the product ( Armstrong ) warrants to the original user of those products supplied by it and used in the service and in the manner for which they are intended, that such products shall be free from defects in material and workmanship for a period of one (1) year from the date of installation, but not longer than 15 months from the date of shipment from the factory, [unless a Special Warranty Period applies, as listed below]. This warranty does not extend to any product that has been subject to misuse, neglect or alteration after shipment from the Armstrong factory. Except as may be expressly provided in a written agreement between Armstrong and the user, which is signed by both parties, Armstrong DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. The sole and exclusive remedy with respect to the above limited warranty or with respect to any other claim relating to the products or to defects or any condition or use of the products supplied by Armstrong, however caused, and whether such claim is based upon warranty, contract, negligence, strict liability, or any other basis or theory, is limited to Armstrong s repair or replacement of the part or product, excluding any labor or any other cost to remove or install said part or product, or at Armstrong s option, to repayment of the purchase price. As a condition of enforcing any rights or remedies relating to Armstrong products, notice of any warranty or other claim relating to the products must be given in writing to Armstrong: (i) within 30 days of last day of the applicable warranty period, or (ii) within 30 days of the date of the manifestation of the condition or occurrence giving rise to the claim, whichever is earlier. IN NO EVENT SHALL ARMSTRONG BE LIABLE FOR SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE OR PROFITS OR INTERRUPTION OF BUSINESS. The Limited Warranty and Remedy terms herein apply not withstanding any contrary terms in any purchase order or form submitted or issued by any user, purchaser, or third party and all such contrary terms shall be deemed rejected by Armstrong. 10

Notes 11

Armstrong provides intelligent system solutions that improve utility performance, lower energy consumption, and reduce environmental emissions while providing an enjoyable experience. Armstrong International North America Latin America India Europe / Middle East / Africa China Pacific Rim armstronginternational.com 111-EN 2017 Armstrong International