SC-6DS,SC-10DS and SC-16DS DIRECT STEAM CONVECTION STEAMER INSTALLATION OPERATION MAINTENANCE

Similar documents
INSTALLATION & OPERATION MANUAL FOR ELECTRIC COUNTER CONVECTION STEAMERS MODELS VSX3, VSX4 & VSX5

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION AND OPERATION MANUAL ELECTRIC COUNTER CONVECTION STEAMER MODELS: SX-3 SX-5

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMER MODEL: GCX-2 GCX-10

OPERATOR S MANUAL Electric Counter Convection Steamer

OPERATOR S MANUAL Electric Counter Convection Steamer

ECO-JET CONVECTION STEAMER W/TWIN GENERATORS INSTALLATION - OPERATION - MAINTENANCE EJ-10E MODELS

MODEL HC24EA SERIES ELECTRIC COUNTERTOP CONVECTION STEAMERS

BLP-E ELECTRIC FLOOR MODEL BRAISING PAN WITH ELECTRIC POWER TILT INSTALLATION OPERATION MAINTENANCE

INSTALLATION AND OPERATION MANUAL ELECTRIC TILTING SKILLETS MODELS: ETS - 30 ETS - 40

INSTALLATION & OPERATION MANUAL

ST10-2G GAS TWO COMPARTMENT CONVECTION STEAMER WITH TWIN GENERATORS INSTALLATION - OPERATION - MAINTENANCE

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS:

PCE_YBD60-100_IB_WM_ENG_V2_ indd 1

INTEK STEAMER ELECTRIC MODEL XS

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

OWNER'S MANUAL INSTALLATION USER'S GUIDE SERVICE PARTS CONVECTION STEAMER ELECTRIC BOILER

OWNER S MANUAL. Form Number: S-6086 REV: A 07/11

ECO-TECH PLUS ELECTRIC CONVECTION STEAMER INSTALLATION - OPERATION - MAINTENANCE ETP-10E MODEL

INSTALLATION AND OPERATION MANUAL ALL MODELS

STEAMER INSTALLATION AND OPERATION MANUAL MODEL SPG6 FOR SERVICE CALL

INSTALLATION & OPERATION MANUAL

ECO-TECH PLUS GAS CONVECTION STEAMER INSTALLATION - OPERATION - MAINTENANCE MODEL

Cleveland. When You Need a Lot and Need It Fast

KPS-E, KLS-E AND KLT-E SERIES

INSTALLATION AND OPERATION MANUAL DIRECT STEAM COUNTER TILTING KETTLES MODELS: DC - 5 DC - 6 DC - 10 DC - 12 DC - 20

GAS FIRED STEAMER Models SX-34GCR and SX-55GCR

REPAIR MANUAL 24/36CEM24/36/48 24/36/CGM200/250/300

OWNER S MANUAL MODEL A COOKER

Steamer Simply Invent GBv6 27/11/06 18:50 Page C1 SIMPLY INVENTS.

Steamer and Rice Cooker Instruction Manual

max menu start stop FS470 series

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

FOOD STEAMER. HY- 4401DS V~ 50/60Hz 800W HOME ESSENTIALS LIVE COMFORTABLE HOUSEHOLD USE ONLY

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMERS MODELS: GSX-5HE GSX-7HE GSX-10HE GSX-16HE

Owner s Manual For Models #EPC640, EPC650, EPC660, EPC640D, EPC650D & EPC660D

Microwave Grill. Microwave Grill. with Grill Press Lid. OWNER S MANUAL For Model #KK-1502

BDO-100-E Lakeside Avenue, Burlington, Vermont USA Telephone: (802) Fax: (802) PN Rev A (5/14)

Instruction Manual MS-192W

MANUAL A-PLUS STEAM COOKER

SO DIGITAL CONVECTION OVEN with 8 PRE-PROGRAMMED SETTINGS

Express Crock Multi-Cooker

10,000 prize draw. instructions. EXTRA year guarantee FREE rewards gallery. details. Register online now!

Digital Pressure Cooker OWNER S MANUAL 6-QUART MODEL: PC-WAL2 8-QUART MODEL: PC-WAL3

INSTALLATION & OPERATING INSTRUCTIONS. for FRESH-O-MATIC MODEL 4000 SERIES

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

OWNER S MANUAL ELECTRIC STEAM-IT STEAM COOKER, STYLE C MODEL ST-E

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

Samson Silent Dehydrator

Cleveland Range REPAIR MANUAL

6 in in USE & CARE ALUMINUM/ALUMINIO PRESSURE COOKER/ / OLLA DE PRESIÓN

INSTALLATION & OPERATION MANUAL

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

OWNER S MANUAL CAPELLA STEAMER

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Operating instructions

OWNER S MANUAL. 6-Quart Digital Pressure Cooker. IMPORTANT: Do Not Use This Power Cooker Until You Have Read This Entire Manual Thoroughly!

I N ST R UC T I ON HEC20 & HEC20D ELECTRIC CONVECTION OVENS MODELS FORM Rev.D (Mar. 2001)

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

CONNECTIONLESS STEAMER

Steambaker DG3 Instruction manual

UNIVERSE PLUS STGL & STGM SERIES

the Steam Zone Instruction Book - BFS800

INSTALLATION AND OPERATION MANUAL ELECTRIC COUNTER TILTING SKILLET MODEL: ECTS-12

Rice Cooker & Food Steamer. Instruction Manual. ARC-700 Series

6 Litre Electric Pressure Cooker

User Manual PKFD08. NutrichefKitchen.com

Thank you for choosing

Owner s Manual For Models #EPC640, EPC650, EPC660, EPC640D, EPC650D & EPC660D

ZEPHAIRE-100-E AND ZEPHAIRE-200-E

Operating and Installation Instructions

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

operator manual FRESH-O-MATIC Model 4000 This document includes:

OWNER S MANUAL ALTAIR II STEAMER

Congratulations... Index

User Manual Steamer KS KT

INSTALLATION AND OPERATION MANUAL ELECTRIC COUNTER TILTING SKILLET MODEL: ACECTS-12

F-T, FT-P, F-L AND F-P SERIES

Upright Freezer 048-GM-48307

EN p Ref. NC /2009 JPM & Associés marketing-design-communication

ommunication 10/2011 eting-design-c mark Ref. NC JPM & Associés

SBF Series ELECTRIC CONNECTIONLESS STEAMER INSTALLATION - OPERATION - MAINTENANCE

MT 25/40 GALLON SERIES

DESIGN CLASS FUNCTION

Operating and Installation Instructions

Operating and Installation Instructions

Owner s Guide Read and Keep These Instructions

Operating and installation instructions Steam oven

6 Litre User s Manual

AMW 450 AMW 460 AMW 461

2 LITER ELECTRIC MULTI-POT. Instruction manual

Contents. 03 Welcome. 04 General Information and Safety Instructions. 05 Description of parts. 06 Instructions. 09 Cooking tips and recipes

MERCHANT POPCORN MACHINE SERVICE MANUAL

ALTAIR II CONVECTION STEAMER INSTALLATION - OPERATION - MAINTENANCE. Altair II-4 Altair II-6 Altair II-8 Altair II-10 Altair II-12 MODELS

Built-in Conventional oven

Руководство пользователя скороварки

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

bc14g combi oven serial numbers with iw/ix/iz/jg/jo

6 Litre User s Manual

Transcription:

SC-6DS,SC-10DS and SC-16DS DIRECT STEAM CONVECTION STEAMER INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802) 864-0183 S00048 Rev 1 C (12/08)

IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. CAUTION: Operating, testing, and servicing should only be performed by qualified personnel. NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs. Intended for commercial use only. Not for household use. This manual should be retained for future reference. 2

TABLE OF CONTENTS DESCRIPTION PAGE Important Notes 2 1.0 Service Connections 4 2.0 Installation Instructions 5 3.0 Operating Instructions 8 4.0 Periodic Maintenance 9 5.0 Troubleshooting 9 6.0 Cooking Chart 10 3

16.75 [425] 25 [635] 55.5 [1410] SC-6DS 68.50 [1740] SC-10DS 67 [1702] SC-16DS 33 [838] 1.0 SERVICE CONNECTIONS ELECTRICAL CONNECTION: 1/2" conduit connection to controls. 120VAC-60Hz-1PH 2 AMPS DRAIN: 2" IPS piped to open floor drain. No Solid Connection. COLD WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kpa). S STEAM SUPPLY: 3/4" IPS for in coming steam at 80 lbs./hr. @ 10 psi. (36 kg/hr @ 69 kpa) min. 100 psi (690 kpa) maximum supply pressure DIMENSIONS ARE IN INCHES [MM] 2 [51] 2.75 [70] 3.5 [89] 0 [0] 1.5 [38] 24 [610] 15.25 [387] 0 [0] 2.5 [64] 10 [254] S 9.5 [241] S 28 [711] 20.5 [521] S 18 [457] SC-6DS & SC-10DS 17 [432] 8.75 [222] 6 [152] SC-16DS 5.75 [146] 0 [0] REAR FLANGED FOOT DETAIL 2 EQUALLY SPACED Ø7/16" [11mm] HOLES ON 2.5 [63] B.C. SC-6DS & SC-10DS TOP VIEW SC-16DS TOP VIEW 4

2.0 INSTALLATION INSTRUCTIONS Ideally an exhaust system should be located directly above the appliance to exhaust steam and heat generated by the appliance. 1. Set the unit in place and level using a spirit level. 2. Ascertain that a floor drain (open gap) is convenient to the appliance drain. 3. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet. 4. Remove appliance and drill holes in locations marked on floor and insert proper anchoring devices. 5. Set unit back in position and re-level left to right and front to back. 6. Bolt and anchor appliance securely to the floor. 7. Seal bolts and flanged feet with Silastic or equivalent compound. 8. Make service connections as indicated. WARNING: Electrical and grounding connections must comply with applicable portions of the National Electrical Code and/or other local electrical codes. WARNING: Disconnect electrical power supply and place a tag on the disconnect switch to indicate that you are working on the circuit. Use copper wire suitable for at least 200 degrees Fahrenheit (90 degrees Celsius). The steamer must be grounded. The wiring diagram is located on the inside right hand panel as you face the steamer. 5

INFORMATION TO STEAM FITTER 1. Each cooking compartment requires approximately 1 BHP (34.5 lbs of steam per hour) to operate satisfactorily. 2. Assuming availability of 30 psi supply steam pressure immediately to the appliance, then pipe sizes of ½" or 3/4" or 1" will deliver respectively 90, 165 or 385 lbs. of steam per hour to the appliance Heat Exchanger. From the foregoing to use ½" pipe line would most likely prove inadequate. An extremely important consideration is the pressure drop that will occur through the steam supply line from its point of origin to the appliance. The greater the length of piping and number of valves and elbows, the greater will be the pressure losses. Consider a pressure drop of 1 (one) psi for each straight length of pipe equivalent to 120 diameters of that pipe. Thus, a 1" pipe having a straight length of 120" (10 feet) is equivalent to 120 diameters of that pipe and will have a pressure loss of 1 psi through that pipe. Example: 10 p.s.i. Supply Pressure 120 Diameters of 1 pipe Equivalent to 120 (10 ft) 9 p.s.i. Available Pressure Note, in 3/4" pipe size, that a Standard 90º Elbow and Angle Valve and a Globe Valve are equivalent to 1.8 feet, 10 feet and 18 feet respectively of straight pipe. Similarly, in a 1" pipe size, a standard 90º Elbow and Angle Valve and a Globe Valve are equivalent to 2.2 feet, 12 feet and 23 feet respectively of straight pipe. Example: 20 GLOBE VALVE 40 PSI SUPPLY 3 1 PIPE 90 ELBOW 17 10 32 PSI 6

Total of above = 20 + 2.2 + 3 + 2.2 + 17 + 23 + 10 + 2.2 = 79.6 feet. Since each 10 feet is equivalent to 1 psi pressure loss, 79.6 feet is equivalent to approximately 32 psi from an original Boiler supply of 40 psi. It is suggested that, wherever possible, the steam supply line to the appliance is a separate line from the steam source. If the appliance must be supplied from a line supplying other appliances, the pipe sizes and pressure will have to be verified. Further, during idle periods, when the steam in the supply line is not in use, water will form from condensed steam in the supply line. It is advisable to prevent water pockets from forming in the steam line and impeding the steam flow when it is required. Therefore, the steam supply line should be installed level or run slightly downwards towards the appliance. Install a Ball Float Trap near the appliance to drain out water (condensed steam) from the line to assure clean dry steam to the appliance. 1 2 3 INLET TO HEAT EXCHANGER TO DRAIN 7

3.0 OPERATING INSTRUCTIONS CAUTION: Live steam and accumulated hot water in the compartment may be released when the door is opened START-UP Start-up procedures for the steamer must be completed once daily prior to operation. 1. Turn on the water and steam supply to the appliance. 2. Open the cabinet door and turn the power switch to ON. A pilot light comes on indicating the appliance is ready to begin operation. With the READY pilot on, preheat each steamer compartment for one minute when the steamer is to be fist used for the day or whenever the compartment is cold. OPERATION 1. With cooking compartment preheated and ready pilot light on, place pans of food to be cooked into compartment and shut door. 2. Set timer to cooking time desired. Cooking cycle may be interrupted at any time by opening door and resumed again by closing door. 3. When buzzer sounds, it indicates the end of the cooking cycle and that no more steam is entering the compartment. Cooking pilot light will go off and ready pilot light will come on. Buzzer must be shut off by turning the timer to its off position. CAUTION: An obstructed drain can cause personal injury or property damage. Frequently check that the compartment drain and plumbing is free of all obstructions. Never place food containers, food or food portion bags in the cooking compartment in such a way that the compartment drain becomes obstructed. Each compartment is equipped with a removable drain screen. Frequently check the drain screen for accumulation of food particles. Should food particles accumulate against, or clog the drain screen, remove it, clean it thoroughly and then replace it in its original position. SHUT DOWN 1. To shut down cooking compartment, set timers to their OFF position and leave doors slightly open. 2. At the end of the day, open the door of the cabinet base and turn off power switch. Turn off external steam supply valve. 8

4.0 PERIODIC MAINTENANCE Never spray water into electric controls. CLEANING 1. Keep exposed cleanable areas of unit clean at all times. 2. Thoroughly wash oven cavities, door liners, and pan racks at the end of each day or as required with a mild detergent and water to prevent bacterial growth and odors. 3. Remove drain screens from inside compartment drains. Using a plastic bottle brush and mild detergent, clean inside the drain opening ensuring there is no food residue or blockage. Clean the drain screen and replace in its original position. 4. Wash gasket sealing surface with mild detergent to remove harmful food acids and rinse. 5. Keep all exposed cleanable areas of unit clean at all times. DO NOT GET WATER IN ELECTRICAL BOX OR ANY ELECTRICAL COMPONENTS. ADJUSTMENTS At least twice a year have an authorized service person clean and adjust the unit for maximum performance. 5.0 TROUBLESHOOTING DOOR LEAKS 1. Check for damage to door gasket. 2. Gasket may be adjusted if necessary by turning the screws in the gasket plate counter clockwise. WATER ACCUMULATES IN THE COMPARTMENT 1. Compartment drain screen clogged. Remove and clean thoroughly and then replace. 9

6.0 COOKING CHART The following table lists suggested cooking times and weights. These times, which will vary depending on initial product temperature, size, shape, etc., are approximate and should be adjusted to suit your operation. PRODUCTS TO BE COOKED IN SOLID PANS Product Timer Setting in Minutes Weight Per Pan Eggs, Scrambled 10-12 8 Dozen Rice, Long Grain (Cover with 4 cups water/lb) 25 2 Lb Pasta (Place perforated pan inside solid pan, cover pasta with cold water) Spaghetti - Regular/Vermicelli Macaroni - Shells/Elbows Noodles - ½" Wide Lasagna Noodles 12-15 15-18 12-15 15-18 Frozen Casseroles, Lasagna 35 Full Pan Meat Loaf, 3 - Each 40 1 Beef Ground Chuck Slices as Purchased 20-25 35-40 10 Lb 10 Lb Shrimp, Frozen, 10 Shrimp per Lb 5 4 Lb Beans Baked Refried 9 9 10 Lb Can 10 Lb Can Canned Vegetables 6 10 Lb Can Prunes, Dried 12-15 10

PRODUCTS TO BE COOKED IN PERFORATED PANS Product Timer Setting in Minutes Weight Per Pan Clams Frozen Fresh, Cherrystone 10-12 5-6 3 Dozen 3 Dozen King Crab, Frozen Claws Legs 4 4-6 2 ½ Lb 4 ½ Lb Lobster Tail, Frozen Lobster, Live, 10" - 12" 6 5 10 Lb 4 Per Pan Salmon Fillets, Frozen, 8 oz Each 5 7 ½ Lb Scallops, Fresh 4 3 Lb Scrod Fillets, Fresh 3-5 4 Lb Eggs Hard Cooked Soft Cooked Soft Yolk for Caesar Salad 15 9-10 6-8 4 Dozen 4 Dozen 4 Dozen Chicken, Breasts, Legs, Thighs 20 1 Turkey, Frozen Breasts (2) Cut length wise 90 55 6-7 Lb Ea. 20-2 Corned Beef 40-75 6-8 Lb Hot Dogs or Wieners 3 80-100 Count Asparagus Spears Frozen Fresh 10-12 5 3 Dozen Beans Green, 2" Cut, Frozen/Fresh Lima, Frozen Baby Lima, Frozen 6 8 5 Broccoli Spears, Frozen Spears, Fresh Flowerettes, Frozen 8 6 6 4 Lb 11

PRODUCTS TO BE COOKED IN PERFORATED PANS Product Timer Setting in Minutes Weight Per Pan Brussel Sprouts, Frozen 6 Cabbage, Fresh, 1/6 Cut 8 Carrots Baby Whole, Frozen Crinkle Cut, Frozen Sliced, Fresh Cauliflower, Flowerettes Frozen Fresh Celery, 1" Diagonal Cut 7 Corn Yellow Whole Kernel, Frozen Cobbettes, Frozen Corn-On-Cob, Fresh 8 7-8 11 6 7-8 5 8 16-18 10-12 16-18 7 Lb 4 Lb 9 Lb 4 Lb 27 Ears 80 Ears 18 Ears 54 Ears Peas, Green 6 Potatoes, Whole Russet 55 10 Lb Spinach Chopped, Frozen Defrosted Fresh Cut Squash, Acorn, Halves 25 10 Halves Zucchini, Slices 8 10 Lb Frozen Mixed Vegetables 6-7 Fruit, Blanch for Peeling Grapefruit Oranges Pineapple, Whole for Cutting 4 COOKING HINTS Where possible, spread food out evenly in pans. Do not allow food to protrude above pans, since this will interfere with steam circulation between pans in the compartment. Always preheat compartments for satisfactory results. When time does not allow for defrosting of frozen vegetables, such as loose-pack peas, corn diced carrots, etc., they may be cooked at once provided just half of the suggested portions in the cooking chart are used. 17 5 3 3 6 Lb 6 Lb 2 Lb 12