Installation Instructions DTC-24 SNOw MELTING &

Similar documents
DTC-24 SNOW MELTING & ROOF DE-ICING CONTROLS

THERMAL MANAGEMENT SOLUTIONS

ADDITIONAL INFORMATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

THERMAL MANAGEMENT SOLUTIONS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

flexibility programmed settings.

User manual and installation guide

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SSV-DC user manual. Phason

Static Pressure Control

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

ACS-30-EU-VIA-DU-20-MOD

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

PARAGON Commercial Refrigeration Controls

DS-8C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

Oakton TEMP 9500 Advanced Multiparameter Controller

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

Product Instructions. Basic Digital Snow Melt Control II. Applications. Features. Specifications

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

Warranty Info: ETI s warranty policy can be viewed at:

Programmable Thermostat

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

EC Series Wall Unit Humidifier

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Simple to Set Timer (SST) Frequently Asked Questions

ACS-30-EU-EMDR- 10-MOD

Premier Hazard STC Instructions

MODEL GF PRO AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Polymer solutions Heating mat EM2-CM

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

ECC-1 user manual and installation guide

HT-2 / 9600 Series Control Contents

Centro-Matic Automated Lubrication Systems System Controls

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Climate Cŏntrol Multifunction Hydronic Control Installation and Operation Manual. Uponor Radiant Heating and Cooling Systems

B-40/B-41 Modulating Temperature Controller

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Fluid Cooler Fan and Pump control panel

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Control Panel Checklist

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

Container Refrigeration

TH232-AF-230 Installation Instructions

SAFETY INFORMATION AND WARNINGS

Product Manual SZ1009

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Thermal Stripper, TSFB-125 User Manual

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)


CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

IMPORTANT INSTRUCTIONS READ & SAVE

Water Leak Detector. Installation and Troubleshooting. Overview

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Analog Room Pressure Monitor RPC Series

T600MEP-2 Programmable Economizer Thermostat

1.1 Controller General Information

Automatic Lamp & Mat Heating Control


User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

GUIDE BOOK FROSTIE FROST FIGHTING CONTROLLER

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

IMPORTANT INSTRUCTIONS READ & SAVE

PULSAFEEDER MODEL 3210 MICROPROCESSOR-BASED CONDUCTIVITY CONTROLLER INSTALLATION & OPERATION MANUAL SERIAL #:

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

MODEL URS-1: FACTORY RETROFIT PROGRAM

H&H Asia Group Limited

FPC-02 Series. Installation and Operating manual

IMPORTANT INSTRUCTIONS READ & SAVE

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Marley Collection Basin Heater Circuit

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Transcription:

Installation Instructions SNOw MELTING & ROOF DE-ICING controls R Roof and Gutter De-icing or Snow Melting Control S Roof and Gutter De-icing or Snow Melting Control Contents page Section 1. Overview 1.1 Precautions... 2 1.2 Base model components... 2 1.3 General accessories... 2 1.4 Operation... 2 Section 2. INSTALLING 2.1 Installing the control panel... 3 2.2 Electrical connections... 3 2.3 Electrical connections... 4 2.4 Installing the RG roof sensor... 6 2.5 Installing the MP slab sensor... 7 2.6 Installing the MMP sensor... 8 2.7 Installing the RID... 9 Section 3. PROGRAMMING 3.1 LED display settings...10 3.2 Programming setpoint temps and alarms...11 3.3 LED screen alarm displays and resetting alarms...11 3.4 Locking the keypad...13 Section 4. Testing and trouble shooting 4.1 Maintenance... 14 4.2 System function test... 14 4.3 Trouble shooting and Technical Support... 14 A Roof and Gutter De-icing or Snow Melting Control

Section 1. Overview 1.1 PRECAUTIONS Installation must comply with local electrical codes. All related components and this control should be properly rated for the specified location classification. The control must be installed by a qualified electrician. The control panel enclosure is rated NEMA 4X. 1.2 BASE MODEL COMPONENTS R S A (1) Control Panel (1) Control Panel (1) Control Panel (1) RG Sensor (1) MP Sensor (1) MMP 1.3 GENERAL ACCESSORIES Accessories Product Number RGS* SMP* SMMP* R.I.D. MPSWP-50 MPSW-50 RSW-50 Description Secondary gutter mounted moisture sensor for R or S Seconday slab mounted sensor for S Secondary aerial mounted moisture sensor for A Remote indication and activation timer plenum rated six conductor #22 AWG sensor extension wire non-plenum rated six conductor #18 AWG sensor extension wire RID extension wire * Note: Wire secondary sensors (RGS, SMP, or SMMP) in parallel with primary sensor. Connections to be made in appropriately rated junction boxes. 1.4 OPERATION The is intended to control heating cable in the application of slab snow melting or roof and gutter de-icing. The control panel provides low voltage for an external slab or gutter sensor(s), and/or RID (remote indication and activation timer). The system will activate when the following two conditions are met: 1. The slab/ambient temperature is less than the setpoint temperature [typically 40 o F (4.4 C)]. 2. Snow or moisture is present on the moisture sensor. The system will deactivate when one of the following conditions are met: 3. No moisture is present on the sensor and the countdown timer has finished (preset on time with sensor dry). 4. When ambient or slab temperature exceeds the setpoint temperature. The system remains deactivated until the two activation conditions reoccur. Installation must comply with local electrical codes. All related components and this control should be properly rated for the specified location classification. The control must be installed by a qualified electrician. The control panel enclosure is rated NEMA 4X. 2

Section 2. Installation 2.1 Installing the Control Panel The control panel can be installed outdoors or indoors. Mount the control panel as shown in Detail 1. Attach with #6 screws 6.575 in 3.425 in Detail 1. Installing control panel. 2.2 Electrical Connections 1 INSTALLING 1. Connect THE cord grip or ENCLOSURE 1/2 (13mm) conduit for low voltage wiring to the. SM 7/30/2013 SCALE: 2. Connect NTS1/2 (13mm) conduit in the pre-punched hole on the bottom left and route low voltage wiring to the Power Control Panel with GFPE and 24 VAC/VDC source. Low voltage, class 2 wiring Connections Detail 2. Electrical connections. 2 INSTALLING THE ENCLOSURE SM SCALE: NTS 7/30/2013 3

Mechanical Activation 120 VAC Activation Dry Alarm Contacts 24 VAC Section 2. Installation 2.2 Electrical Connections Plug-In Power Supply RID connection connection Sensor Sensor connector Relay power match relay coil voltage Detail 3. Electrical wiring 3 ELECTRICAL WIRING OF THE SM SCALE: NTS controlling a relay. Dry control contacts Low voltage class 2 Relay coil 7/30/2013 Delta-Therm Controls. Power Panel with GFPE Terminal connections. Low voltage, class 2 wiring TA 1 2 3 4 5 6 7 8 TA1 & 2 Mechanical Activation TA3 & 4 120 VAC Activation TA5 & 6 Dry Alarm Contacts TA7 & 8 24 VAC Common dry contacts for remote alarm indication. RID connection Sensor connection Power Panel with GFPE connection. Detail 4. Electrical connection when Power Control panel with GFPE is switching load. 4

Section 2. Installation 2.3 Electrical Connections WHEN POWER CON- TACTOR PANEL WITH GFPE IS SWITCHING LOAD 1. Connect 1/2 (13mm) conduit for low voltage in the pre-punched hole on the bottom right of the control panel. Plug-In Power Supply RID connection Sensor connection External transformer connection. Dry control contacts Low voltage class 2 Detail 5. Electrical connection when contactor panel is switching load. Detail 5. Electrical wiring when contactor panel is switching load. 5

Section 2. Installation 2.4 INSTALLING THE RG ROOF Sensor 1. Place the RG sensor in the gutter using half of the supplied double-sided adhesive pad, directly under a drip loop. Do not locate the RG sensor under trees, awnings, next to a structure, or in any location which may be blocked from snow. 2. The can be provided with the RG sensor attached to the control panel with approximately 10 (3.04m) of sensor wire. To lengthen or shorten the sensor wire (press on the top of the terminal to release/insert wire): Remove the six conductors of the sensor wire from the terminal block inside the control panel and loosen the sensor wire connector. Gently pull the sensor wire through the wire connector and either cut to length as needed or splice on additional extension sensor wire in an appropriate junction box.* Gently pull sensor wire back through the wire connector and reconnect the six conductors to the terminal block. 3. Wrap the remaining half of the adhesive pad around the Thermistor. The pad should adhere to itself. Stick the thermistor to the upper inside edge of the gutter. Do not allow the thermistor to touch the heating cable or any other heat source. *NOTE: Select appropriate rated wire if exposed to sunlight (UV Inhibited) or route through a plenum air space. DE-ICING CABLE SENSOR Detail 6. Installing the RG sensor in the gutter 6

Section 2. Installation 2.5 INSTALLING THE MP SLAB Sensor The MP sensor is mounted flush with the heated surface in an area most indicative of snow conditions. Do not locate the MP sensor under trees, awnings, where cars are parked, next to a structure, or in any location which may be blocked from snow. The can be provided with an MP sensor. Attach to the control panel with approximately 10 (3.04m) of sensor wire. To lengthen or shorten the sensor wire (press on the top of the terminal to release/insert wire): Remove the six conductors of the sensor wire from the terminal block inside the control panel and loosen the sensor wire connector. Gently pull the sensor wire through the wire connector and either cut to length as needed or splice on additional extension sensor wire in an appropriate junction box.* Gently pull sensor wire back through the wire connector and reconnect the six conductors to the terminal block. *NOTE: Select appropriate rated wire if exposed to sunlight (UV Inhibited) or route through a plenum air space HEATING CABLE SENSOR PROBE 3/4" CONDUIT HEATING CABLE Detail 7. Plan view of a slab sensor. PAVING MATERIAL SENSOR PROBE SENSOR FINISHED SURFACE BASE Detail 8. Side view of slab sensor. LEVELING BLOCK (IF REQUIRED) 3/4" CONDUIT 7

Section 2. Installation 2.6 INSTALLING THE MMP SENSOR 1. Place the MMP sensor in the gutter or an area most indicative of snow conditions. Do not locate the MMP sensor under trees, awnings, next to a structure, or in any location which may be blocked from snow. The MMP sensor can be attached to a junction box using the supplied.75 (19.05 mm) PVC conduit connector. 2. The can be provided with the MMP sensor attached to the control panel with approximately 10 (3.04m) of sensor wire. To lengthen or shorten the sensor wire (press on the top of the terminal to release/insert wire): Remove the six conductors of the sensor wire from the terminal block inside the control panel and loosen the sensor wire connector. Gently pull the sensor wire through the wire connector and either cut to length as needed or splice on additional extension sensor wire in an appropriate junction box.* Gently pull sensor wire back through the wire connector and reconnect the six conductors to the terminal block. *NOTE: Select appropriate rated wire if exposed to sunlight (UV Inhibited) or route through a plenum air space. Detail 9. Installing the MMP sensor at roof level. 8

Section 2. Installation 2.7 INSTALLING THE RID 1. Drill a hole for cord grip or a.5 (12.7mm) conduit fitting in the enclosure. 2. Install low voltage three conductor cable or the.5 (12.7mm) conduit from the to the RID junction box. 3. Install a low voltage three conductor cable or three insulated wires (22 awg minimum) from the to the RID via the conduit. 4. Connect the red, green, and black wires of the RID to the R (red), G (green), and B (black) terminals of the via the three installed conductors. NOTE: The RID indicates de-icing/snow melting system activation and can communicate with the to switch on the de-icing/snow melting system via the approximate 75 minute or 5 hour timer setting with the jumper on the back of the RID. If the de-icing/snow melting system is activated by the sensor communicating with the, the RID cannot override the to switch the de-icing system off. Low voltage, class 2 wiring RG SENSOR R.I.D. TIMER ON RID connection Sensor connection SYSTEM ON DELTA-THERM START TIMER RESET Sensor and RID wiring Detail 10. Installing the RID. 9

Section 3. Programming 3.1 LED DISPLAY SETTINGS The banner heading Delta-Therm Corp Heat Trace CTL is displayed after applying power to the control panel. After the banner heading is displayed the LED screen will display the temperature as detected by the RTD and the control panel setpoint temperature. If the keypad is locked-out, move the red dipswitch on the inside enclosure door into the enable position. FACtory Default Settings: Setpoint Temperature = 40 F With sensor dry continue: 2 hrs. Temperature cannot be set lower than 0 F. Delta-Therm Corp CTL Detail 11. Display message upon first applying power to the control panel. This will display for a few seconds only. Temperature 80F Setpoint= 40F Temperature 80F sensor= wet Detail 12. Default display message, temperture as detected by the RTD and control panel setpoint. After a few seconds the display will switch setpoint = 40F to display sensor = wet or dry. 10

Section 3. Programming 3.2 PROGRAMMING SETPOINT TEMPERATURE and count down timer There are three dual purpose selector push-buttons: ENTER/MENU, YES/arrow pointed up (referred to as YES/up ), and RETURN/arrow pointed down buttons (referred to as RETURN/down ). The parameters can be accessed in the following order: 1. To access parameters: Press the ENTER/MENU button for up to 4 seconds and the LED screen will display: Set-up & reset. Remove finger and wait for the Setpoint=40F message to display. Set-up & reset Detail 13. The set-up and reset message will display after pressing and holding the ENTER/MENU for approx. four seconds. 2. To enter or change the setpoint temperature: Press YES/up arrow button and the LED screen will display: Setpoint = 40F (Setpoint = 40F is the default setting). Temperature cannot be set lower than 0 F. 3. Press the YES/up arrow button to raise the setpoint temperature. Press the RE- TURN/down arrow button to lower the setpoint temperature. 4. When the LED screen displays your setpoint temperature press the ENTER/MENU button and With sensor dry continue: 2hrs. will display. Setpoint= 40F Detail 14. Press the YES/up arrow button to raise setpoint temperature. Press the RETURN/down arrow button to lower setpoint temperature. Press ENTER/MENU button to move on to next parameter. 11

Section 3. Programming 3.2 PROGRAMMING SETPOINT TEMPERATURE and count down timer 5. To enter the countdown time: After the With sensor dry continue: 2hrs. is displayed you can change the count down timer setting from 0 hours to 24 hours. Press YES/ up arrow button to raise the count down timer up to 24 hrs. Press the RETURN/down arrow button to lower the count down timer down to 0 hrs. Press ENTER/MENU button to accept the new time duration. With sensor dry continue: 2 hrs. Detail 15. Press the YES/up arrow button to raise the Count Down Timer up to 24 hours. Press the RETURN/down arrow button to lower the Count Down Timer down to 0 hours. Press ENTER/MENU button to move on to next parameter. 6. The LED screen will display System Reset?. Press the RETURN/down arrow button to save the settings. System Reset? Detail 16. When the System Reset? message is displayed, press the RETURN/ down arrow button to save settings. 12

Section 3. Programming 3.3 LED screen alarm displays and resetting alarms The Sensor wire fail message will display if either of the blue or black sensor wires are open, the sensor heater fails, or the red and green sensor wires are shorted. Please refer to Section 4.3 Trouble shooting and technical support. Sensor wire fail Detail 17. The Sensor wire fail message. 3.4 LOCKING THE KEYPAD A red dipswitch, labeled enabled/disabled input, is located on the inside of the enclosure door. Move the dipswitch into the left position to enable the keypad. Move the dipswitch into the right position to disable the keypad. 13

Section 4. Trouble-Shooting And Technical Support 4.1 MAINTENANCE Clean the surface of the sensor before the start of each heating season with a brush or other means to remove dirt, grime, leaves, or debris that obstructs contact with snow or ice. Perform the system function check before the start of each heating season. 4.2 system function test 1. Confirm all wiring is complete per wiring diagrams. 2. Ensure that power wiring will not be applied to any snow melting cable that is not embedded in concrete, asphalt, or in a crushed rock bed under pavers. Ensure that all the roof and gutter de-icing cable is terminated per manufacturer s instructions. 3. Apply 24 VAC or 24 VDC to the. The Delta-Therm Corp, Control banner will be briefly displayed. 4. The display will show the temperature at the sensor and alternate the temperature setpoint with the moisture status of the sensor. 5. To test the system you 1) raise the temperature setpoint above the temperature shown for the sensor. The maximum settable temperature is 100 F for warm weather testing. 2) Set the sensor dry countdown to 0 as detailed in the programming instructions. 6. Pour water on the sensor, the display will show Moisture Sensed, System On, and alternate with the temperature and setpoint screen. 7. This activation will close the dry control contacts on the circuit board. This can be used as a single pole switch for the coil voltage on a contactor or relay. Verify the power controlling device has been activated. 8. Dry the sensor to deactivate the system. Confirm the power controlling device has also deactivated. 9. Re-enter set-point and the sensor dry countdown timer. 10. If using an RID device, confirm system activation and deactivation using the RID up/ down toggle switch and LED indicator lights. 4.3 TROUBLE-SHOOTING AND TECHNICAL SUPPORT Display does not turn on Keypad does not respond Sensor is dry though display says wet or sensor is wet though display says dry Air temperature is different than shown on display Sensor wire fail shown on display does not activate power panel RID control is not shown on display System operates after snow is removed - Check 24 vac or vdc voltage at terminals - Check connector on display - Check connector wiring - Check for damage - Check enable/disable switch - Check connector wiring - Check sensor wiring/splices - Replace sensor - Sensor in direct sunlight - Sensor is showing slab temperature - Sensor is in contact with warm object - Incompatible sensors used - Temperature accuracy is less below 30 F - Check splices and wire for damage - Replace sensor - Check wiring - Check power panel is operational - control contacts are dry, to be used as a single pole switch - Only shown when control is not controlling the power panel - Reduce countdown timer appropriately For additional Trouble-Shooting Procedures, please contact Delta-Therm Technical Support for Trouble-Shooting Manual. If you have any questions or comments about these instructions, or your installation please call Delta-Therm between the hours of 8:00 a.m. - 5:30 p.m. CST, Monday through Friday at 1-800-526-7887. 14 C_DTC24_1308_II