Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

Similar documents
CC Series VACUUM PUMPS

ULTRA LOW TEMPERATURE FREEZER. User Manual

7165 Dust Collector Owner s Manual

KRF15A-03 KRF25A-03 KRF40A-03

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

Tornado Operations & Maintenance Manual

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Multi Wet & Dry Vacuum Rechargeable 10286

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Operating Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

SPECIFICATIONS FEATURES

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

690 and Power Fishing Systems

High Output Vacuum/Pressure Pump

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

PORTABLE DEHUMIDIFIER

OWNER S MANUAL #DC2000B #DC2000BCF

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

OPERATING INSTRUCTIONS

5HP CYCLONE DUST COLLECTOR MANUAL

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Original instructions. Operation Manual & Cautions

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Bench-Top Vacuum Oven with 28 segments programmable controller

GALAXY FLOOR MACHINE

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TABLETOP PTC TOWER HEATER

CV100T Dry Canister Vacuum. Technical Information & Safety Page 3, 4

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

3/4 HP Model Trimmer Operating Instructions

8 lb Lightweight Vacuum Model CK LW 13/1

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Quest 105, Dry155, and 205 Dual

BLAST-IT-ALL BUMPER BLASTER

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

UB20 12V DC. Owner s Manual

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

AZN ATEX INSTALLATION AND MAINTENANCE

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

Quest PowerHeat HFC 100 Pro

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

R 5 Central Vacuum Systems

1 HP Air Mover. Owner s Manual

V-Series. Oil Lubricated Rotary Vane Vacuum Pumps

M Series Fan Filter Units

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Room Air Conditioner Service and Parts Manual

OPERATING INSTRUCTIONS

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

TYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL

CL & CLG Clamp Mount Mixers

ECOPLUS MAG DRIVE UTILITY PUMP INSTRUCTIONS

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

KINNEY OIL MIST ELIMINATORS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

FLOOR RAMMER. Throttle Type. Blows per Minute. (L) Lever Inches 609 mm

18E ELECTRIC FAN HEATER

690 Power Fishing System

PORTABLE HAND POWER THREADER 1/2-2

30-pint Dehumidifier User Guide

Up to 60 Pint Commercial Grade DEHUMIDIFIER

ELECTRIC FLAT PANEL FIREPLACE HEATER

ATD /8 Electric Drill

OWNER S MANUAL (English)

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

INSTALLATION INSTRUCTIONS FOR ACCESSORY COMBUSTION AIR INLET FILTER KIT FOR ULTRA HIGH EFFICIENCY WATER HEATERS (PART# ) KIT CONTENTS:

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

Owner s Manual Window Air Conditioner

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

Model: PC600. Batch: PR3496. POWER:1000W AC V, 50/60Hz For your safety, always read the instruction book carefully before using.

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Model Illustrated DZ400A

Transcription:

As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products not only use less energy, produce less noise and last longer but also to ensure that they have the best design for the environment and for reducing pumped gas pollution. Excellent design and production will bring you more convenience. 1. Pump Use ATD vacuum pumps are designed to obtain vacuum by pumping gas from sealed containers. They are suitable for use with R12, R22 and R134a air conditioning systems, as well as medical appliances, printing machinery and vacuum packing. They can be continuously used at 5 to 40 2. Features Oil Anti-flowback Design The gas inlet is specially designed to prevent the oil from flowing back, preventing the container being pumped as well as the hoses from becoming polluted. Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution. Aluminum Alloy Casing The ATD vacuum pump is manufactured with an aluminum alloy casing. Because aluminum has good heat dissipation qualities, it will help to keep the pump running more efficiently for a longer period of time. Overall Design The electric machinery and the pump are designed to make the product compact and lighter.

Easy to start, Faster to pump The starter design makes the ATD vacuum pump easy to start even in lower temperatures. This feature allows higher efficiency and faster pumping. Low Noise and Vibration An elastomeric coupling insert between the motor and module results in extremely quiet and smooth operation. 3. Product Illustration

4. User s Manual Examine the oil-level before using to make sure the oil-level is not lower than the oil-level line in the sight glass. DO NOT RUN PUMP WITH LOW OIL LEVELS. Add oil to bring it up to the oil level line. This pump uses high-speed vacuum oil HFVM200 or equivalent. Connect the container to be pumped to the gas inlet. The hose should be short, sealed and free of dust, dirt and heavy condensation. Check for leaks before operating pump. Take off the exhaust cap, plug in the power supply and turn the switch to the on position. Unplug the vacuum pump, remove the connecting hoses and cover the exhaust cap and oil plug after using. 5. Cautions Don t pump flammable, explosive or poisonous gases. Don t pump gas that can corrode metals and exert chemical charges. Don t pump gas containing any dust or moisture. The temperature of the pumped gas shouldn t be over 80 and the room temperature should be around 5 to 40 Don t use vacuum pump as a compression pump. Pump cannot be run without oil The operating voltage is between 110V to 115V, 60Hz. You must use a grounded

outlet. When unplugging the pump, pull the plug. Don t unplug unit by pulling on the wire. Keep electrical cord free from all shop equipment, and do not let pump hang by power cord Don t use damaged plug or outlet. Don t plug or pull out the plug with wet hands. Don t plug unit in, unplug unit or use switch if there are any flammable or explosive gases present. Always Unplug unit before disassembling. 6. Installation When in use, the pump should be horizontal and should be positioned where it is dry, ventilated and free of dust and other contaminants. In order to ensure proper air flow, you must maintain a clearance around the pump of at least 5 cm (2 inches). To permanently mount the vacuum pump, remove the rubber pads from the bottom of the base, and use the existing threaded holes to mount unit. Connect with M4x12 screw and M4 nut. When permanently mounting this pump, be sure to maintain proper clearances around the unit, especially at the air intake in the end of the vane shell. If a special electromagnetic valve is needed, it can be installed on the gas inlet. 7. Troubleshooting

Problem Possible Cause Correction Low Degree of Vacuum 1. Lack of oil 2. Oil is not clean 3. The oil inlet is blocked 1. Add oil to above the oil level line 2. Change the oil 3. Clean the oil inlet or clean the filter 4. The hoses or gas inlet are 4. Check the connecting pipes clogged 5. Get suitable pump for your 5. The pump is not suitable for application your application Oil Leaks 1. The oil seal is damaged 1. Change oil seal 2. The housing gasket is loose 2. Change the housing gasket or worn out Oil Spray 1. Too much oil 1. Oil to the oil-level line 2. The pressure at the gas inlet 2. Change to a bigger pump is too high or it has pumped too much Starting 1. The oil temperature is too low 1. Start the pump several times to try Difficulty 2. Electrical malfunction to heat the oil 3. Foreign matter is in the pump 2. Check and have it fixed 3. Check and remove it 8. Maintenance Keep the pump clean and prevent foreign matter from entering. Keep the oil filled to the full level. Don t let pump run without oil. Keep the oil clean. If the oil becomes dirty, muddy, or water or other volatile substance gets in, it will affect the performance of the pump and the oil should be replaced. Before replacing the oil, start the pump and have it run for about 30 minutes to make the oil thin. Stop the pump and drain the oil from the oil drain plug. At this time, open the gas inlet to release any pressure inside the pump. This will allow the oil to drain more freely. After making sure the pump is clean, put the drain plug back in

and then fill the pump oil to the oil-level. To store the pump when not in use for long periods of time, cover the oil cap and exhaust cap and store it in a dry place. Repair of pump should only be done by experienced repair facilities. 9. Technical Specifications Model: ATD-3425 Model Power Supply: 110V 60HZ Free Air Displacement: 5 CFM Number of Stages: 1 Stage Ultimate Vacuum: 180 Micron Rotating Speed: 1720 r/min Motor: 1/3 HP Weight: 14 KGS