Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Similar documents
Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert

Circulation pumps BAFA. Wet rotor circulators. gefördert. Heating Drinking water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate

Pumps. Heating Drinking water Solar Geothermy Condensate

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

UP/UPS-B/UPN Hot Water Service Circulators

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Affordable efficiency!

High-efficiency circulating pumps Heating Air conditioning 50 Hz

HIGH EFFICIENCY CIRCULATORS

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

AHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

Grundfos is pleased to announce the sales release of many exciting new products.

TECHNICAL. Series 18. Pump Packages

CR A-F-A-E-HQQE 3x400/ HZ

Technical Product Guide

Circulation Pump Optima

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

FIL-SPL Flow-through heater for central heating USER MANUAL

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

CR A-F-A-E-HQQE 3x400/ HZ

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Heating Control Danfoss Link & Connect Thermostats

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

ecocirc vario Efficiency is affordable! The revolutionary heating circulator Efficiency at low price:

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

1 Declaration of conformity

Calio-Therm S NC/NCV Type Series Booklet

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

product overview ProControl

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

FHM-Cx Mixing Shunts for Floor Heating

Specially Designed Waste Water & Sewage Pumps

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

SIHI Dry GD S Sizes S450, S650

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

EHH SERIES DRAW THROUGH FAN COILS CFM

Smart temperature control solutions

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

ULTRAFLOW 54 DN

MAGNA3 More than A pump

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

Convertible radiator valve for one-pipe systems, centre distance 35 mm

1592P01. for liquids in piping DN

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Heating and D.h.w. Controller RVL482 Basic Documentation

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

ELECTRIC BOILERS FOR CENTRAL HEATING

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Heat Link. Technical Guide

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Standard. thermostatic valve body without presetting

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Pump Program. fluids gases solids. edur.com. Developed and manufactured in Germany... since 1927

Flush individual room control for floor heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Operating Instructions

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Transcription:

Circulation pumps Wet rotor circulators and accessories eating Drinking water Solar Geothermy Condensate CATALOGUE

alm produces highly-efficient heating circulation pumps alm has been successfully developing and producing heating circulation pumps for over years. It started out manufacturing for renowned OEM customers before electing to develop and produce its own product range in the late s. Its proficiency in the development of innovative, market-oriented products is first and foremost reflected in the more than half a century of company history. Today, in the third generation, the circulation pumps segment plays a major part in the success of the company. This is particularly evident in the high level of creative innovation in recent years, with many new products in the field of high-efficiency pumps. alm places great demand on the quality of its products Modern production facilities and processes are just as much part of the corporate concept as well thought-out quality management. Internal testing facilities and ISO-certified quality management are indispensible factors of success. Long-standing customers value the high demands placed on the quality of the products and the flexibility with which alm meets custom requirements. alm is helping to shape the future as a reliable partner A company is only as good as each of its constituent parts. This is why motivated and experienced employees are a key element of success at alm. Flexibility and expertise head the list of priorities for being a reliable partner to our customers. Together with over employees, alm s objective is to make a lasting contribution to the future with its products. alm high efficiency pumps already fulfil the tightened requirements of the eco-design directive from until. The new EP Optimo features an LED display showing the modes of operation, the pressure head, the total electrical input power as well as error codes. As standard, it is delivered with a plug and with installation length mm also the insulation shell is included in delivery. No insulation shell is offered for mm installation length. For the EP Optimo Basic version, we ommit features such as display, insulation shell and plug but we fit a premounted cable in order to be able to offer a very well-priced model for different applications for which these features are neither required nor necessary. New in the delivery range are condensate pumps for gas and oil condensing boilers called Lift and a complete line of large EP Optimo L+ circulators. With this new high quality line of threaded and flanged circulators the whole replacement and new buildings demand for heating, air conditioning and refrigeration applications can be covered from / m to DN/ m. The new EP Optimo L+ complements the existing low cost series EP Optimo L which have been designed for the main types of applications with head or m. UPA UE EP EP Plus + EP EP Optimo Plus (N) EP BB EP-L EP Optimo L EP Optimo L+

Catalogue valid for EU countries + others ) Contents Page Contact General information Product range eating EP Optimo: igh efficiency pumps with LED display, electronically controlled EP Optimo Basic: igh efficiency pumps, electronically controlled EP Optimo L: igh efficiency pumps with LCD display, electronically controlled EP Optimo L+: igh efficiency pumps with LCD display, electronically controlled Drinking water EP Optimo (N): igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo Basic (N): igh efficiency pumps with stainless steel housing, electronically controlled BUPA (N): Standard circulation pumps for drinking water with stainless steel housing BGPA (N): Circulation pumps for drinking water, with stainless steel housing, pressure head - m Solar EP Optimo Solar: igh efficiency pumps with LED display, electronically controlled EP Optimo L Solar: igh efficiency pumps with LCD display, electronically controlled EP BB: Babelbox BB and EP PWM Geothermy EP Optimo Geo: igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo L Geo: igh efficiency pumps with LCD display, electronically controlled and protected against condensation Condensate Lift: Condensate pump for gas condensing boilers up to kw Lift Basic: Condensate pump for gas condensing boilers up to kw Lift NT: Condensate pump for oil condensing boilers with neutralization tank Accessories/Spare parts Screw connections Flange adaptors for pipe installation (flange) Insulation shell/insulation shell for cold water applications Plug Accessories/Spare parts for condensate pumps ) EFTA (Iceland, Liechtenstein, Norway), Croatia, Switzerland, autonomic areas of EU member states (Faroe Islands, Jersey, Isle of Man, Guernsey, Greenland), Andorra, Monaco, San Marino. Subject to technical changes without notice. Errors and ommissions excepted. The latest versions of our sales, delivery, and payment conditions as well as guarantee terms can be found on the internet at www.halm-pumps.de

Contact at alm: Sales Mr Robin Pomreinke E-mail: robin.pomreinke@halm.info Phone: + - Fax: + - Order Management Ms Sabrina Wagner E-mail: sabrina.wagner@halm.info Phone: + - Fax: + After Sales Mr Jürgen Albrecht E-mail: juergen.albrecht@halm.info Phone: + - Fax: + - Mr Thomas Müller E-mail: thomas.mueller@halm.info Phone: + - Fax: + Service hotline Phone: + -

General information alm type key EP Optimo -. G Pump types Nominal width pipe connection Pressure head in meters water column Speed switchable or electronically controlled Installation length (mm) Installation options Circulation pumps must be installed with a horizontal shaft. Construction alm circulation pumps are inline wet rotor circulators. They are maintenance-free and fitted with opposite-facing connecting nozzles of the same nominal width. The pump, motor and terminal box comprise one unit and are optimally matched with one another. A stainless steel can separates the rotor chamber and stator winding. It features static seals at both ends. Bearing Both bearings are made of oxide ceramic. This is particularly suitable because of its hardness, surface quality and corrosion resistance. They ensure smooth running and a long service life. Air cavities in the can well are evacuated via the hollow shaft. EEI The benchmark of the most efficient circulators is EEI.. All alm m high efficiency pumps fulfill the requirements for BEST in class.

igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX. EP Optimo XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation + space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps with LED display, electronically controlled EP Optimo series, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ¼........ -.. EP Optimo -. G ¼........ -.. EP Optimo -. G ¼........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ¾ ¼........ -.. EP Optimo -. G ¾ ¼........ -.. EP Optimo -. G ¾ ¼........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. EP Optimo -. G ½........ -.. Constant pressure......... EP Optimo...-.-G Q (m / h)............ EP Optimo...-.-G Q (m / h) EP Optimo...-.-G....... Q (m³ / h)........................ Proportional pressure......... EP Optimo...-.-G Q (m / h)............ EP Optimo...-.-G Q (m / h)....... EP Optimo...-.-G Q (m³ / h)................................. EP Optimo...-.-G Q (m / h)............ EP Optimo...-.-G Q (m / h) EP Optimo...-.-G....... Q (m³ / h)........................ Dimensions Dimension illustration G Type L L L L EP Optimo / L L L L

igh efficiency pumps, electronically controlled EP Optimo Basic series, product group valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Rate of flow: up to. m /h Pressure head: m/ m/ m Control range: - W/- W/ - W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX. EP Optimo Basic XX-. GXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps, electronically controlled Serie EP Optimo Basic, product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ¼........ -.. EP Optimo Basic -. G ¼........ -.. EP Optimo Basic -. G ¼........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ¾ ¼........ -.. EP Optimo Basic -. G ¾ ¼........ -.. EP Optimo Basic -. G ¾ ¼........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. EP Optimo Basic -. G ½........ -.. Constant pressure......... EP Optimo Basic...-.-G Q (m / h)............ EP Optimo Basic...-.-G Q (m / h)... EP Optimo Basic...-.-G.... Q (m³ / h)............. Proportional pressure.. EP Optimo Basic...-.-G Q (m / h)................... EP Optimo Basic...-.-G Q (m / h).................. EP Optimo Basic...-.-G Q (m³ / h)............... EP Optimo Basic...-.-G Q (m / h)................... EP Optimo Basic...-.-G Q (m / h)........... EP Optimo Basic...-.-G....... Q (m³ / h)........................ Dimensions Dimension illustration G Type L L L L EP Optimo Basic / L L L L

igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)

igh efficiency pumps with LCD display, electronically controlled EP Optimo L series, product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L -. G ½ -......... -.. EP Optimo L -. G ½ -......... -.. EP Optimo L -. G ¼ -......... -.. EP Optimo L -. G ¼ -......... -.. EP Optimo L -. G - - DN......... -.. EP Optimo L -. G - - DN......... -.. EP Optimo L -. G - - DN......... -.. EP Optimo L -. G - - DN......... -.. Proportional pressure Constant pressure EP Optimo L...-. G EP Optimo L...-. G EP Optimo L...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure EP Optimo L...-. G EP Optimo L...-. G step EP Optimo L...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group Insulation shell included in delivery + lected power values (-% of maximum curve). The display shows alternately head, flow rate and power consumption. In cases of disturbances the icon SERVICE lights and additional error codes shown on the display enable a rapid troubleshooting. DIP switches located in the Circulator terminal box can be used optionally for locking against unauthorized adjustment and/or for an activation of the night setback mode. Materials Component Material Material no. Pump housing Grey cast iron, KTL EN-GJL- Impeller Plastic with fiberglass PSU-GF Shaft Stainless steel. Bearing /Graphite Can Stainless steel. Insulation shell Polypropylen Rate of flow: to m /h depending on model Pressure head: m/ m/ m/ m/ m Control range: to W depending on model Media temperature: - C (non freezing) to + C Installation length: to mm depending on model Circulator connection: ½ and (thread)/dn + + + (flange) Protection class: IP Insulation class: F Nominal pressure: PN Control Internal: External: pc + pv + Eco Mode + fixed rpm analogue - V Start/Stop (bridged terminal ex works) Omnibus fault message: Selector switch, potential free. Product features igh-efficiency wet running circulator with integrated automatic modes and additional eco mode for additional savings of approx. % compared to the best proportional pressure control. Convenient operation with multi-knob and dip switch. Optional night mode and locking against unauthorized adjustment. Clear display of function, setting and operating status via backlit icons and LCD display. Connection possibility of external control (- V, start / stop signal) and omnibus fault indication. Numerous integrated additional functions (autom. air ventilation, soft-start/inrush current limitation, anti blockage function, electronic motor protection against thermal overload). igh-quality manufacturing and standard insulation shells. Use The wet-running high-efficiency circulators EP Optimo L+ have an electronically commutated synchronous motor with permanent magnet rotor and a continuously variable differential pressure control. They are designed for use in circulating systems with variable or constant flow. The inline pump housings are resistant to corrosion by a cathodic electrodeposition coating. The EP Optimo L+ are designed for a static operating pressure of bar. Main areas of use eating, air conditioning/refrigeration, solar, heat pumps and industrial facilities as dual pipe system boiler and primary circuit single pipe system storage loading circuit panel systems like underfloor heating Flow media heating water as per VDI. pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components. media with a max. viscosity of mm /s. operating data must be checked above % glycol. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C (non-freezing) to + C Ambient temperature To avoid condensation on the pump housing, the media temperature should always be equal to or higher than the ambient temperature (see table). Otherwise, as well as for temperatures from - C to + C, we recommend using a diffusion-tight insulation shell (see accessories). Ambient temperature Media temperature min. Media temperature max. C C C c C C C C C C C C C C C C C C Motor protection An external motor protection is not required. The integrated electronic motor protection automatically reduces the power at overload. Simultaneously, a warning appears on the display. Minimum inflow pressure To avoid cavitation noise and circulator damage the following minimum inlet pressure must be maintained at the pump suction nozzle. The values apply up to m above sea level. Otherwise, a surcharge of. bar per m time should be added. Media temperature < C > C bis < C Minimum inflow pressure, bar, bar Sound pressure level The sound pressure level is db (A). Controls function With the multi-function button, all settings can be made easily and quickly. The multifunction button consists of an outer dial for the selection of the desired mode and the power set values, and an internal activation pushbutton for the programming start and for the confirmation of the selected mode or the power set point. Lit symbols in the motor cap indicate which mode has been active or selected. By pressing the activation pushbutton for more than seconds, the pump is reset to factory default settings. LED segments located around the outer dial show blue enlightened for the se-

igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group Model Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L+ -. G " ½"......... -. EP Optimo L+ -. G " ½"......... -. EP Optimo L+ -. G " ½"......... -. EP Optimo L+ -. G " ½"......... -. EP Optimo L+ -. G ¼" "......... -. EP Optimo L+ -. G ¼" "......... -. EP Optimo L+ -. G ¼" "......... -. EP Optimo L+ -. G ¼" "......... -. EP Optimo L+ -. G ¼" "......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. EP Optimo L+ -. G......... -. Performance curves EP Optimo L+ -. G and Eco Mode [m] Eco Mode [m] Constant pressure and Proportional pressure Δp-v Δp-c EP Optimo L+ -. G and Eco Mode [m] Eco Mode Constant pressure and Proportional pressure [m] Δp-v Δp-c / - / / - / / - / / / / / / EP Optimo L+ -. G and Eco mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / - / - / / / / - / - / / / / EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / - / / - / / - / / / / / /

igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / / / / - / - / / / - / - / / EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / / / - / - / / / - / - / / EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / - / / / / - / - / / / / / EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / - / - / / / / / / - / - / EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode [m] Δp-v Δp-c [m] Eco Mode [m] Δp-v Δp-c / / - / / / / / - / / / / /

igh efficiency pumps with LCD display, electronically controlled EP Optimo L+ series, product group EP Optimo L+ -. G EP Optimo L+ -. G and Eco Mode Constant pressure and Proportional pressure [m] Eco Mode and Eco Mode [m] / / / / - / - EP Optimo L+ -. G Constant pressure and Proportional pressure Eco Mode Constant pressure and Proportional pressure / / / / - / / - / / Δp-v Δp-c / / [m] - / - Eco Mode [m] Δp-v Δp-c / / and Eco Mode [m] / / EP Optimo L+ -. G and Eco Mode [m] / Δp-v Δp-c [m] Eco Mode Constant pressure and Proportional pressure [m] Δp-v Δp-c Dimensions (Flange Dimensions in mm) Combination PN Dimension illustration PN Flanges ØD Øk n x d ØD Øk n x d DN x Ø x Ø DN x Ø x Ø DN x Ø x Ø DN x Ø x Ø Dimension (Circulator dimensions in mm) F (mm) EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G EP Optimo L+ -. G Dimension illustration (Threaded version) A F B R/G E E (mm) Dimension illustration (Flange version) A F G B DN E D (mm) D C (mm) C B (mm) D A (mm) C Model

igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Insulation shell With installation length mm included in delivery. valid for all alm m igh efficiency pumps Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo XX-. NXXX. EP Optimo XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box + automatic adjustment to pressure conditions stainless steel pump housing pre-mounted, screwable angle entry-plug compact design optical fault indication optical display control mode Use The electronically controlled EP Optimo (N) high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating systems as well as drinking water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or drinking water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use drinking water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps with LED display and stainless steel housing, electronically controlled EP Optimo (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo -. N ½........ -.. EP Optimo -. N ½........ -.. EP Optimo -. N ½........ -.. EP Optimo -. N ½........ -.. EP Optimo -. N ¾ ¼........ -.. EP Optimo -. N ¾ ¼........ -.. EP Optimo -. N ½........ -.. EP Optimo -. N ½........ -.. Constant pressure......... EP Optimo...-.-N Q (m / h)............ EP Optimo...-.-N Q (m / h)............. Proportional pressure......... EP Optimo...-.-N Q (m / h)............ EP Optimo...-.-N Q (m / h)...................... EP Optimo...-.-N Q (m / h)............ EP Optimo...-.-N Q (m / h)............. Dimensions Type L L L L EP Optimo (N) // Dimension illustration G L L L L

igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length:, and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Basic XX-. NXXX. EP Optimo Basic XX-. NXXX Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw convenient operation valid for all alm m igh efficiency pumps + space-saving axially integrated terminal box automatic adjustment to pressure conditions stainless steel pump housing pre-mounted cable ( m) compact design Use The electronically controlled EP Optimo Basic (N) high efficiency wet rotor circulators with permanent magnet technology are designed for use in heating systems as well as drinking water systems with variable or constant rate of flow. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or drinking water systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Flow media drinking water up to a temperature of C and a degree of hardness of d (temporary hardness) heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. Main areas of use drinking water systems Materials Component Material Material no. Pump housing Stainless steel. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps with stainless steel housing, electronically controlled EP Optimo Basic (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Basic -. N ½........ -.. EP Optimo Basic -. N ½........ -.. EP Optimo Basic -. N ½........ -.. EP Optimo Basic -. N ½........ -.. EP Optimo Basic -. N ¾ ¼........ -.. EP Optimo Basic -. N ¾ ¼........ -.. EP Optimo Basic -. N ½........ -.. EP Optimo Basic -. N ½........ -.. Constant pressure......... EP Optimo Basic...-.-N Q (m / h)............ EP Optimo Basic...-.-N Q (m / h)............. Proportional pressure......... EP Optimo Basic...-.-N Q (m / h)............ EP Optimo Basic...-.-N Q (m / h)...................... EP Optimo Basic...-.-N Q (m / h)............ EP Optimo Basic...-.-G Q (m / h)............. Dimensions Type L L L L EP Optimo Basic (N) / Dimension illustration G L L L L

Standard circulation pumps for drinking water with stainless steel housing BUPA (N) series, T product group Rate of flow: up to. m / h Pressure head: up to m Media temperature: + C to + C Installation length:, and mm Threaded connection:, ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box Use The BUPA (N) series circulation pumps are wet rotor circulators designed for use in drinking water systems with constant or weakly variable flow rates. They feature a corrosion-resistant pump housing in stainless steel and are thus suitable for use in drinking water circulation systems. Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller PSU - GF Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Bearing plate Stainless steel. Media temperature < C C C Minimum inflow pressure. bar. bar. bar Can Stainless steel. Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Sound pressure level The sound pressure level is < db (A) Flow media Only for drinking water up to a temperature of C and a max. degree of hardness of d (temporary hardness).

Standard circulation pumps for drinking water with stainless steel housing BUPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ¾ ¼......... - BUPA -. N ¾ ¼......... - BUPA -. N ¾ ¼......... - BUPA -. N ½......... - BUPA -. N ½......... - BUPA -. N ½......... -. BUPA...-. N. BUPA...-. N.......... Q (m / h) Q (m / h)........... BUPA...-. N..... Q (m / h)......... Dimensions Type L L L L BUPA (N) // Dimension illustration G L L L L

Circulation pumps for drinking water with stainless steel housing, pressure head - m BGPA (N) series, T product group Rate of flow: up to. m /h Pressure head: up to m Media temperature: + C to + C Installation length: mm Threaded connection: ¼ and ½ Protection class: IP Insulation class: Nominal pressure: PN Control: -step switch with manual speed selection Product features manual start-up feature space-saving axially integrated terminal box pump housing in stainless steel Use The BGPA (N) series circulation pumps are wet rotor circulators designed for use in drinking water systems with a flow rate of > m /h. They feature a corrosionresistant housing in stainless steel and are thus designed for use in drinking water circulation systems. Ambient temperature To avoid the build-up of condensation, the ambient temperature must always be lower than the media temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Materials Component Material Material no. Pump housing Stainless steel. Impeller Polypropylene (PP - GF ) Speed switching The respective speed is set via a rotary switch integrated in the axial terminal box. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Shaft Bearing Media temperature < C C C Minimum inflow pressure. bar. bar. bar Bearing plate Brass. Can Stainless steel. Sound pressure level The sound pressure level is < db (A) Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Flow media Only for drinking water up to a temperature of C and a max. degree of hardness of d (temporary hardness).

Circulation pumps for drinking water with stainless steel housing, pressure head - m BGPA (N) series, T product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. BGPA -. N ¾ ¼......... - BGPA -. N ¾ ¼......... - BGPA -. N ¾ ¼......... - BGPA -. N ¾ ¼......... - BGPA -. N ½......... - BGPA -. N ½......... - BGPA -. N ½......... - BGPA -. N ½......... - BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) BGPA...-. N Q (m / h) Dimensions Type L L L L BGPA (N). Dimension illustration G L L L L

igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Insulation shell With installation length mm included in delivery. + Rate of flow: up to. m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Solar XX-. GXXX. EP Optimo Solar XX-. GXXX valid for all alm m igh efficiency pumps Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Solar high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in solar systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps or solar systems), best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use solar systems Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps with LED display, electronically controlled EP Optimo Solar series, S product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Solar -. G ½........ -.. EP Optimo Solar -. G ½........ -.. EP Optimo Solar -. G ¼........ -.. EP Optimo Solar -. G ¼........ -.. EP Optimo Solar -. G ½........ -.. EP Optimo Solar -. G ½........ -.. EP Optimo Solar -. G ¾ ¼........ -.. EP Optimo Solar -. G ¾ ¼........ -.. EP Optimo Solar -. G ½........ -.. EP Optimo Solar -. G ½........ -.. Constant pressure......... EP Optimo Solar...-.-G Q (m / h)............ EP Optimo Solar...-.-G Q (m / h)............. Proportional pressure......... EP Optimo Solar...-.-G Q (m / h)............ EP Optimo Solar...-.-G Q (m / h)...................... EP Optimo Solar...-.-G Q (m / h)............ EP Optimo Solar...-.-G Q (m / h)............. Dimensions Dimension illustration G Type L L L L EP Optimo Solar / L L L L

igh efficiency pumps with LCD display, electronically controlled EP Optimo L Solar series, S product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: + C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Solar high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use solar systems Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: + C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A)

igh efficiency pumps with LCD display, electronically controlled EP Optimo L Solar series, S product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Solar -. G ½ -......... -.. EP Optimo L Solar -. G ½ -......... -.. EP Optimo L Solar -. G ¼ -......... -.. EP Optimo L Solar -. G ¼ -......... -.. EP Optimo L Solar -. G - - DN......... -.. EP Optimo L Solar -. G - - DN......... -.. EP Optimo L Solar -. G - - DN......... -.. EP Optimo L Solar -. G - - DN......... -.. Proportional pressure Constant pressure EP Optimo L Solar...-. G EP Optimo L Solar...-. G EP Optimo L Solar...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure EP Optimo L Solar...-. G EP Optimo L Solar...-. G step EP Optimo L Solar...-. G step LOW Q (m / h) LOW Q (m / h) step Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

EP BB Babelbox BB and EP PWM, S product group Supply voltage: V Power input:. W Signal input leading edge: - V Signal input trailing edge: - V Signal input wave packet: - V, z Signal input power consumption:. ma PWM output: V DC, ma Frequency: z Ambient temperature: C to + C Cable connection input: x M Dimensions: x x mm Weight:. kg Use The Babelbox BB is designed for use in heating systems in which an on-site controller pulses a standard pump via the power line and this pump is to be replaced by a high-efficiency pump. igh-efficiency pumps do not react to a pulsed power line and therefore cannot simply substitute for a standard pump. Interposing the Babelbox BB solves this issue while retaining the control functions of the system. Mode of operation The BB automatically detects if an on-site controller is pulsing the power line via a wave packet or is outputting leading or trailing edge voltage. The BB converts this into a PWM signal which is identified by the alm PWM pump. Just like the standard pump previously, its power is also then controlled. An integrated LED shows the presence of voltage from the on-site controller. Main areas of use All applications in which a standard pump controlled externally by the power line is to be replaced by a high-efficiency pump. Return flow boost Solar installation Differential temperature controlled underfloor heating Storage charging circuit Freshwater station (suitability should be checked with the manufacturer due to the highly sensitive controlled system) Installation Stable cable bushings and elevator terminals enable easy installation. The BB must be connected to V voltage, with the PWM pump and the pulsed power line. Fully automatic detection of the input signal means no further settings need be adjusted. Motor (high efficient ECM technology) Power supply nominal: - V, - z Power consumption: Version m (- W); Version m (- W) Power consumption stand-by PWM:. W PWM connection PWM input: Frequency f nominal: Voltage U nominal: Power PWM to V: Power PWM to V: Insulation voltage optocoupler: - z - V max. ma max. ma VRMS (T ein / T pwm ) x Standards //EG, //EG, //EG EN -, EN --, EN -:+A:, EN -:+A.+A: EN -:, EN --:, EN, EN --, EN --, EN -, EN - The Babelbox BB solution! It was previously not possible to replace standard heating pumps driven by wave packet, leading or trailing edge control with high-efficiency pumps. For the first time, this can now be done with the Babelbox BB. Fully automatic signal detection! Typical high-efficiency pumps require a V constant voltage supply. If, however, a high-efficiency pump is connected to a variable power voltage supply (solar controller, freshwater station controller, charging controller etc.), it reacts neither to a wave packet nor leading edge control as desired. This is where the Babelbox BB from alm comes in. It independently and fully automatically detects which signal is being output by the controller of the standard pump and converts it into a PWM signal which can be understood by the high-efficiency pump, controlling the latter in just the same way as the previously installed standard pump. The voltage supply for the high-efficiency pump itself comes from a separate V connection.

EP BB Babelbox BB and EP PWM, S product group Type Connection pipe Threaded connection Installation length (mm) P (W) In (A) Weight (kg) Product no. EP BB -. G " ½"........ -. EP BB -. G " ½"........ -. EP BB -. G ¼" "....... -. EP BB -. G ¼" "....... -. EP BB -. G ½" "........ -. EP BB -. G ½" "........ -. EP BB -. G " ½"........ -. EP BB -. G " ½"........ -.......... EP PWM...-.-G Q (m / h)................ EP PWM...-.-G Q (m / h).,.....,.......

igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Insulation shell With installation length mm included in delivery. Rate of flow: up to. m / h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: and mm Threaded connection:, ½ and Protection class: IP Insulation class: F Nominal pressure: PN Control: pc + pv + fixed rpm EEI:. EP Optimo Geo XX-. GXXX. EP Optimo Geo XX-. GXXX valid for all alm m igh efficiency pumps + Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Product features manual start-up feature smooth running very low energy consumption integrated night economy feature air-vent screw LED display convenient operation space-saving axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing pre-mounted, screwable angle entry-plug compact design Use The electronically controlled EP Optimo Geo high efficiency wet rotor circulators with LED display and permanent magnet technology are designed for use in heating and cold water circulation systems with variable or constant rate of flow. The motor integrity offers a sealed winding protection from ingress of condensation. The cataphoretic coated pump housing is stainless. Mode of operation p control When thermostatic valves in systems with a long main supply heating pipe (likely for radiator systems) close, the total flow drops. This results in lower pipe resistance in this main pipe, which means the pump has to create lower head. Using proportional pressure mode PP ( ) is the best setting for such heating systems, as here the pump decreases head at lower flow. If the main supply heating pipe has not to be taken into consideration, because it is short or has its own pump (likely for underfloor heating systems with in mixing units integrated pumps) or heating pumps, best mode to go with is constant pressure mode CP ( ). In such heating systems, it is important always to have constant pressure for the radiators or ufh-circuits, as the pressure loss in the main pipe is not considered and all other consumers are installed in parallel, which does not influence the maximum pressure loss. Integrated night economy feature When the automatic night economy feature is activated, the circulation pump switches between normal mode and economy mode (characteristic curve MIN). The flow temperature is detected by a temperature sensor, the pump reacts accordingly. For this, it is necessary for the circulation pump to be installed in flow. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Sound pressure level The sound pressure level is < db (A) Choice of control characteristic You can set different control modes via the potentiometer on the axial terminal box. Proportional pressure ( ), fixed speed ( ) and constant pressure ( ) can be adjusted continuously variable. The display indicates power consumption in [W] watts. Once the potentiometer is turned, the display first indicates mode of operation (PP, SC, CP), then value of set head in [m] meters. At the factory setting the potentiometer is in mode PP. Main areas of use eating, air-conditioning and industry systems as dual pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material no. Pump housing Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel.

igh efficiency pumps with LED display, electronically controlled and protected against condensation EP Optimo Geo series, G product group Type Connection pipe Threaded connection Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo Geo -. G ½........ -.. EP Optimo Geo -. G ½........ -.. EP Optimo Geo -. G ¼........ -.. EP Optimo Geo -. G ¼........ -.. EP Optimo Geo -. G ½........ -.. EP Optimo Geo -. G ½........ -.. EP Optimo Geo -. G ¾ ¼........ -.. EP Optimo Geo -. G ¾ ¼........ -.. EP Optimo Geo -. G ½........ -.. EP Optimo Geo -. G ½........ -.. Constant pressure......... EP Optimo Geo...-.-G Q (m / h)............ EP Optimo Geo...-.-G Q (m / h)............. Proportional pressure......... EP Optimo Geo...-.-G Q (m / h)............ EP Optimo Geo...-.-G Q (m / h)...................... EP Optimo Geo...-.-G Q (m / h)............ EP Optimo Geo...-.-G Q (m / h)............. Dimensions Type L L L L EP Optimo Geo / Dimension illustration G L L L L

igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Insulation shell included in delivery. + Rate of flow: up to m /h Pressure head: m/ m Control range: - W/- W Media temperature: - C to + C Installation length: mm (thread)/ mm (flange) Threaded connection: ½ and (thread)/dn and DN (flange) Protection class: IP Insulation class: F Nominal pressure: PN EEI:. EP Optimo L XX-. GXXX. EP Optimo L XX-. GXXX Control: Internal: External: pc + pv + fixed rpm digital: PWM (characteristic lines for heating and solar per VDMA device paper ) frequency f nominal: - z voltage U nominal: - V power I: ma analogue: - V with cable break detection power I: ma impedance: kohm Omnibus fault message: Selector switch, potential-free, power max. A/ VAC Power supply for external unit: Voltage DC V, power max. ma Product features LCD display manual start-up feature smooth running very low energy consumption air-vent screw collective fault signal convenient operation axially integrated terminal box automatic adjustment to pressure conditions cataphoretic coated pump housing Use The electronically controlled EP Optimo L Geo high efficiency wet rotor circulators with LCD display and permanent magnet technology are designed for use in heating systems with variable or constant rate of flow. The cataphoretic coated pump housing is stainless. Main areas of use eating, air-conditioning and industry systems as dual pipe system single pipe system underfloor heating boiler/primary circuit storage charging circuit solar systems and heating pumps Materials Component Material Material No. Pump body Grey-cast iron. Impeller Polyamide (PA - GF ) Shaft Bearing Bearing plate Stainless steel. Can Stainless steel. Flow media heating water as per VDI pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of mm²/s operating data must be checked above % glycol Temperature range Ambient temperature: C to + C Temperature class: TF Media temperature: - C to + C Ambient temperature To avoid condensation forming in the terminal box and stator, the media temperature must always be the same or higher than the ambient temperature. Ambient temp. Media temp. min. Media temp. max. Motor protection External motor protection is not required. Minimum inflow pressure Please determine the minimum inflow pressure for corresponding temperature from the following table. Media temperature < C > C Minimum inflow pressure. bar. bar Controls Function You can make adjustments with the integrated control keys at the front. The LCD display shows the total electrical input power as a numeric value in [W] watts. Different icons at the top of the display show the function, setting and the modes of operation. Sound pressure level The sound pressure level is < db (A)

igh efficiency pumps with LCD display, electronically controlled and protected against condensation EP Optimo L Geo series, G product group Type Connection pipe Threaded connection Flange Installation length (mm) Voltage (V) P (W) In (A) Weight (kg) Product no. EEI EP Optimo L Geo -. G ½ -......... -.. EP Optimo L Geo -. G ½ -......... -.. EP Optimo L Geo -. G ¼ -......... -.. EP Optimo L Geo -. G ¼ -......... -.. EP Optimo L Geo -. G - - DN......... -.. EP Optimo L Geo -. G - - DN......... -.. EP Optimo L Geo -. G - - DN......... -.. EP Optimo L Geo -. G - - DN......... -.. Proportional pressure Constant pressure EP Optimo L Geo...-. G EP Optimo L Geo...-. G EP Optimo L Geo...-. G step step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Proportional pressure Constant pressure EP Optimo L Geo...-. G EP Optimo L Geo...-. G step EP Optimo L Geo...-. G step step LOW LOW Q (m / h) Q (m / h) Q (m / h) Dimensions Type L L L L EP Optimo L (thread) EP Optimo L (flange). Dimension illustration L L L L A

Condensate pump for gas condensing boilers up to kw Lift series, K product group Use The Lift condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x mm (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Product features fully automatic condensate pump delivered completely ready for connection Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media condensates with a p and a C max temperature. condensates with a p over have to be neutralized. condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Switching points Alarm max. mm Start +/- mm Stop +/- mm extremely quiet and vibration free very compact and space-saving construction fully encapsulated pump unit (IP ) resistant to water jets from any direction pump unit also suitable for use in external tank (tank height min. mm, max. mm) integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift m l/h kw incl. pressure hose ( m, Ø x mm) -

Condensate pump for gas condensing boilers up to kw Lift Basic series, K product group Use The Lift Basic condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift Basic condensate pump is designed for gas condensing boilers up to kw. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For very acidic condensate (p < ), for the use of low-sulfur heating oil and for installations/systems with over kw, it is compulsory according to ATV- DVWK-A in Germany to install a neutralization system (see condensate pump Lift NT resp. additional neutralization tank NT). Complementary municipal or other national regulations must be observed where necessary. For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Tank: ABS plastic, max.. l/. Gal Condensation drain: nozzles for hose connection Ø x mm Discharge hose: included in the scope of delivery Weight:. kg Main areas of use gas condensing boilers oil condensing boilers air-conditioning systems refrigerators, refrigerated cabinets, refrigerated counters* dehumidifiers, evaporators *) not suitable for splash water Flow media condensates with a p and a C max temperature. condensates with a p over have to be neutralized. condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C Product features fully automatic condensate pump delivered completely ready for connection extremely quiet space-saving construction housing made from ABS plastics is resistant to condensate integrated check valve for discharge hose condensation discharge hose ( m, Ø x mm) included in delivery pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) pre-mounted alarm cable (. m) incl. wall mounting Delivery program Lift Basic Q (l/h) Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift Basic m l/h kw incl. pressure hose ( m, Ø x mm) -

Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Electrical connection: V, / z Input power: W Alarm contact: max. V, A (resistive load), NO normally open/nc normally closed Protection class: IP Medium: condensate p, temperature C max Rate of flow: max. l/h Pressure head: max. m Noise level: max. db [A] Dimensions: x x m (L x W x ) Condensate supply: Ø mm Condensate suction head: mm Neutralization tank: ABS plastic,. l/. Gal, incl. neutralization granulate ( kg) Condensation drain: nozzles for hose connection Ø x mm Weight:. kg Schematic sketch Lift NT ose nipple suitable for PVC hose, nominal width mm ose length cm Condensate intake Filter Granular Product features fully automatic condensate pump delivered completely ready for connection, incl. neutralization tank noise-reducing electronic controls with follow-up time to reduce switching frequency space-saving construction integrated collection/neutralization tank, incl. first fill with neutralization granulate ( kg) sufficient for about months for systems up to kw upstream suction filter as well as check valve for discharge hose connection for discharge hose (Ø x. mm) Flow direction Main areas of use gas condensing boilers oil condensing boilers Sieve insert with filter Float switch Alarm float switch Flow media condensates produced in gas and oil condensing boilers with a C max temperature. condensates with oil residues from oil condensing boilers must be cleaned with activated carbon (extension kit) if necessary. Temperature range Media temperature: + C to + C Ambient temperature: + C to + C pre-mounted power cable (. m) incl. shockproof plug overflow protection through separate float potential-free alarm connection (NO normally open/nc normally closed) Use The Lift NT condensate pump is a fully automatic unit for the extraction of condensate, produced in gas/oil condensing boilers, air-conditioning systems, refrigerated counters and dehumidifiers incl. collection/neutralization tank. It can be used anywhere where a condensate disposal through gravity is not possible or where there is no direct drain. The Lift NT condensate pump is designed for gas and oil condensing boilers up to kw. It is extensible for systems up to kw with additional accessories NB and NT. The housing is made from ABS plastic and is therefore resistant to acidic condensate (p ). For the use in oil condensing boilers we recommend the additional use of an extension kit with activated carbon (see accessories for condensate pumps). Lift NT,,,,,,, Q (l/h)

Condensate pump for oil condensing boilers with neutralization tank Lift NT series, K product group Delivery program Type Max pressure head Max rate of flow For condensing boilers up to Remarks Product no. Lift NT m l/h kw incl. neutralization tank incl. first fill with neutralization granulate - Connection alarm cable Electronic circuitry Lift NT N L PE L N PE NO C NC Changeover contact Relay A/ V ohmic load Terminal NO-C: normally open contact NC-C: normally closed contact L N PE Consumer Connection example for potential-free contact Cable length m Lift NT

Accessories/Spare parts for circulation pumps Z product group Screw connections without picture Type Product no. Description Grey cast iron connection G -. set c.i. connection Rp ½ x G Grey cast iron connection G ¼ -. set c.i. connection Grey cast iron connection G ½ -. set c.i. connection Rp x G ½ Grey cast iron connection G -. set c.i. connection Rp ¼ x G Brass connection G -. set brass connection Rp ½ x G Brass connection G ¼ -. set brass connection Rp ¾ x G ¼ Brass connection G ½ -. set brass connection Rp x G ½ Flange adaptors for pipe installation (flange) Type Product no. Description FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm FA - flange adaptor grey-cast iron (PN) incl. screws + seal, DN, mm Insulation shell/insulation shell for cold water applications Type Product no. Description WDS A - Insulation shell for EP Optimo (Basic) with installation length mm WDS B - Insulation shell for EP Optimo L with installation length mm WDS C / - Insulation shell for EP Optimo L+ with connection G ½ and WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -./. - Insulation shell for EP Optimo L+ -./. WDS C -./-./. - Insulation shell for EP Optimo L+ -. and -./. WDS C -./. - Insulation shell for EP Optimo L+ -./. WDS C -. - Insulation shell for EP Optimo L+ -. WDS C -. - Insulation shell for EP Optimo L+ -. KDS C -// -// - Insulation shell for cold water applications for EP Optimo L+ -././. and -././. KDS C -. - Insulation shell for cold water applications for EP Optimo L+ -. Plug Type Product no. Description Plug complete -- Plug for series EP complete incl. Socket on motor side without picture Socket only - Socket on motor side for plug for series EP Further accessories and spare parts on request.

Accessories/Spare parts for condensate pumps Z product group Maintenance kit for Lift NT Type Product no. Description Maintenance kit for Lift NT - Maintenance kit for Lift NT for the yearly maintenance consisting of neutralization granulate ( kg), replacement filter sieve with fleece, replacement filter element for suction filters. Extension kit oil condensing boilers Type Product no. Description Extension kit oil condensing boilers - Extension kit for Lift NT for oil condensing boilers consisting of activated carbon filter and sieve. NT Type Product no. Description NT - Additional collection/neutralization tank with granulate ( x kg) for neutralization capacity kw, filter sieves (x) and connection/ nozzle for the connection to the Lift NT. Condensate supply opening Ø mm/condensate supply height mm. NG Type Product no. Description NG - Refill pack neutralization granulate ( kg) Alarm plus Type Product no. Description Alarm plus - Audio and visual fault indicator for the alarm output of the condensate pump ( V, / z) for the connection to the condensate pump with alarm relay output, x x mm (L x W x ), input power. W, IP, ambient temperature + C to + C. Further accessories and spare parts on request.

Your representative: Product no. --EN-EU Version. (/) alm Pumpen + Motoren Gmb Silcherstrasse - Baltmannsweiler, Germany Postfach Baltmannsweiler, Germany Tel: + - Fax: + Email: info@halm.info Web: www.halm-pumps.de +