SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

Discover a new world of colour

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

For more information on Tarkett go to

Web:

Ceram Guide to Slip Resistance Tests

Slip resistance testing of GRP flooring surfaces for Anglia Composites Ltd

RETAIL CREATIVE FLOORING FOR INSPIRATIONAL SPACES.

Slips: framing the issue

BS EN ISO : 2010

Corporate. Laundry SOP. Document Control Summary

Global Safe Technologies (Australia) Pty Ltd

Flooring accessories in public buildings. Creating inclusive environments for the ageing population, with a focus on stair safety. A discussion paper

SAFEGUARD RANGES SLIP RESISTANT VINYL SHEET SAFEGUARD DESIGN SAFEGUARD R10, R11, R12

Australian/New Zealand Standard

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Masslinn Certified efficacy against dust and germs

Infrastructure Technology

Hygiene cleaning equipment Keeping all equipment clean

Sports flooring - Altro in the sporting arena

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number:

2DAY. express UK CORE COLLECTION TODAY AVAILABLE FROM PARTICIPATING STOCKISTS

FORUM FOG FOOD SERVICE INDUSTRY FATS OILS AND GREASE CODE OF PRACTICE SUPPORTED BY

Made for people. Designed for possibilities. Altro Wood Safety collection Pendulum test PTV year 36 R 10 product guarantee

HOW TO TEST YOUR ECOTILE ESD FLOOR

SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

PERFORMANCE THAT KNOWS NO BOUNDARIES

altro.co.uk Cafés, bars and restaurants: floors and walls guide Designed for possibilities. Made for people.

TERRANOVA GENERAL RUBBER FACTS

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

altro.co.uk Food and drink production: floors and walls guide Designed for possibilities. Made for people.

KPS Petrol Pipe System. Making fuel flow safely.

HARMONI GENERAL RUBBER FACTS

Cleaning and Maintenance Guide.

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

SUPPORTING ARCHITECTS, DEVELOPERS AND BUILDERS EVERY STEP OF THE WAY

Care Home Laundry Construction Guide. Supporting architects, developers and builders Every step of the way. Laundry equipment

BS EN ISO : 2010

SAFETY ACTION NOTICE By arrangement with NSS Health Facilities Scotland

MKN Galley Solutions

Hardware for Sliding Doors & Folding Doors

KoolthermTM. Technical Data. HVAC & Building Services Pipe Insulation

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

Food preparation, cooking and service

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Global innovation in fire fighting

The industry standard. Shrink Tunnels

Electrical Safety Policy and Management System

THE TRUE FIRE SURVIVAL CABLE

MARKET LEADERS IN LARGE SCALE COMMERCIAL CLEANING SERVICES

SIZES AVAILABLE INDUSTRIAL: ARCHITECTUAL STEP NOSINGS

G SYSTEM LAUNDRY SOLUTIONS FOR CARE HOMES. LAUNDRY EQUIPMENT

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

BS EN ISO : 2010

YOUR GUIDE TO UNDERSTANDING CPR

Resin Floor Cleaning Guide

Setting the Standard in Third-party Certification

User Manual for your GEH6017 & GEH9017 Cooker Hood

Slips and falls. OHS Exchange FDF - Willis. better information, fewer accidents. 22 nd September

Farms and Similar Agricultural Facilities

The Unexpected Nature of linoleum

Equipment guide for local exhaust ventilation (LEV)

Always ensure that surfaces that are being disinfected are compatible with the product being used.

Hazard Identification and Risk Assessment Form. Risk Assessment

Gas Safety Devices & Accessories

Mini Guide to hygienic laundry practices. based on the RABC system/en 14065

GUIDE TO CLEANING RESIN FLOORS

Are Your Kitchen Hood Filters Compliant?

FIRST-CLASS IN TRAINS

Dyna-Form Air. Alternating Pressure Relief Overlay System

Panic and Emergency Exit Devices

GENERAL CLEANING AND MAINTENANCE FOR ELEVATOR INTERIORS.

Building Care. The complete range of floor and surface wiping solutions for your business. Chicopee True Confidence. chicopee-americas.

Electrostatic Precipitator

IWAKI HI-CERA PUMPS V

This document is a preview generated by EVS

Controlled Door Closing Devices

Exclusive Distributors for

marmoleum modular tiles planks

Fagerhult The Art of Light

Sargasso Range. A new range of radiant panels for heating commercial applications

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

Installation plan Heat pump dryer PT 8203 SL WP

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

The. Range. Clover s colour-coded system for the easy training of cleaning staff C H E M I C A L S.

cookq90.com All Q90 products carry a comprehensive UK two-year parts and labour warranty.

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

Rhyno. Woven Polypropylene Geotextiles. Geosynthetics Limited

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

Transcription:

CASE STUDY CASE STUDY Polysafe Ultima - heavy-duty safety flooring with enhanced slip resistance

POLYSAFE ULTIMA Polysafe Ultima the safety floor designed to suit specification into extremely demanding application areas, offering enhanced slip resistance throughout the guaranteed life of the product. Where is it used? Typically used in busy food preparation areas and commercial kitchens, Ultima is ideal in heavily trafficked areas, where high risks of oil and grease spillages demand a floor that performs day in, day out. In areas where a high number of meals are served each day and the floor is subjected to frenetic use, Ultima is ideal to give user confidence and minimise slip risk in these extremely tough conditions. Polysafe Ultima is a top performer in many heavy-duty commercial areas because of its uniquely engineered surface, with an emboss that facilitates straightforward maintenance. This is combined with a high surface roughness, allowing slip resistance to be maintained in the face of high viscosity contaminants. 4 steps to safety 1. Ultima achieves a result of 40+ on the RRL Pendulum Test in wet conditions using Four S rubber/slider 96, a HSE recommended test for measuring a floor s slip resistance, in-situ. 2. Polysafe Ultima has a unique Surface Roughness, giving typical results of Rz 70µm and therefore suitable for areas encountering oil and grease spillage. Fully compliant with HSE Guidance, Ultima s pendulum and surface roughness results classify the product as low slip potential. Independent test certificates are available from Polyflor on request. 3. Sustainable slip resistance the enhanced level of slip resistance is governed by an increased level of aggregates applied within the product this is from a concentrated amount of coloured quartz, aluminium oxide and silicon carbide, increasing the friction between the foot and floor. Due to these aggregates being applied throughout the full product thickness, this slip resistance is sustainable and can be maintained throughout the guaranteed life of the product, giving that added reassurance over a number of years. It is always advisable to be wary of manufacturers claiming slip resistant performance solely to an R value on the Ramp Test (DIN 51130) and not Pendulum and Surface Roughness tests. The Ramp Test does not give a true reflection of in-situ performance as the procedure can only be undertaken ex-factory and cannot be replicated on-site. 4. Proven cleanability Time and time again, Ultima installations have shown that the flooring in these testing environments can be cleaned without difficulty, using a regular maintenance regime involving a neutral detergent.

CASE STUDY PROJECT: Kitchen area LOCATION: Wrightington Hospital, Wigan, Lancashire FLOORING SUPPLIED: Polysafe Ultima Iron Ore 4340 DATE: January 2007 AREA: 150m 2 Ultimate solution In the kitchen area of the hospital, there is a requirement for large numbers of meals to be prepared for long hours each day, both to hospital café visitors and patients. In this high pressure environment, with lots of movement and turning between work stations, the choice of flooring specified was extremely important in order to minimise the risk of slipping for workers. An initial risk assessment undertaken by the Estates Department identified that due to the various factors such as the type of environment and the likely regular presence of oil and grease contamination, Polysafe Ultima was the ideal specification choice. Offering enhanced slip resistance, being fully HSE compliant and able to cope with the expected levels of spillage, Ultima is tried and tested to give its users confidence in this challenging environment. Kitchen Environment The kitchen area houses a large number of industrial cooking equipment within a relatively confined area, with a variety of grills, fryers and ovens used to create a large number of meals over a 100 per day. Preparation of meals involves a number of staff working quickly at the same time, with the intense daily routines creating plenty of movement over the floor. Oil and grease contamination is a daily occurrence from the fryers and grills and this challenge is dealt with by a combination of good extraction, diligent cleaning and the high surface roughness of Ultima, that gives an enhanced slip resistant surface.

Slip resistance testing at Wrightington Hospital 1. The Munro-Stanley pendulum machine was fitted with an in-date Four S rubber /Slider 96 by a trained operator 2. Check made that the pendulum was level and free from obstruction, ensuring the pendulum arm was free to swing 1 2 3. Pendulum machine calibrated to ensure the reading was zero 4. The slider stroke length was set and prepared with P400 grade paper 3 4 5. Second preparation of the slider undertaken, using pink lapping film 6. The slider length was then set on the floor and a dry test was undertaken 5 6 7. Test repeated but in wet conditions 8. Results recorded and the zero reading was re-checked, prior to the next pendulum swing. Polysafe Ultima received a mean average result of over 40 in the wet 7 8 9. A hand-held Surtronic Duo meter was used to calculate Ultima s surface roughness 10. A mean average surface roughness of over 70 microns was achieved in-situ. This conforms to HSE Guidance on product suitability where contaminants such as oil and margarine are present. 9 10 10

CASE STUDY Slip resistance and in-situ HSE Compliance In order to demonstrate the slip resistance claims made on the Ultima product are sustainable in use at the hospital and adhere to HSE Guidance, an exercise was undertaken to test the floor in-situ, using the methods favoured by the HSE the RRL Pendulum wet test and Surface Roughness test. These tests were carried out by a trained operator in strict adherence to the BS 7976 standard, using the protocols described in the UK Slip Resistance Group Guidelines 2005. Tested after a busy period of food preparation, the floor area was swept and then tested, before the daily maintenance regime had been undertaken. The area was then cleaned and the tests repeated. Firstly, the RRL Pendulum test was carried out in the wet condition, using a Four S rubber/slider 96 and using the recommended slider preparation techniques. A mean average result of over 40 was achieved after 5 swings of the pendulum had been undertaken, both before and after the floor was cleaned by hospital staff. A surface roughness meter was also used on the floor surface to determine the micro roughness of the flooring, with a mean value of several peak to valley measurements being electronically calculated on the floor surface. In both tests before and after cleaning, the mean average of the top three results gave readings of over 70 microns to meet HSE Guidelines. This means that the flooring has sufficient roughness to lower the slip potential in the presence of highly viscous contaminants commonly found in the kitchen, such as olive oil, cooking stock and margarine. Using these slip test results in conjunction with each other, it can be shown that the floorcovering is fully HSE compliant and has sustainable slip resistance in use. According to HSE classifications, Polysafe Ultima is therefore positioned as low slip potential. Cleaning The kitchen at Wrightington Hospital is maintained in a traditional manner, with the daily use of a mop and bucket system. This involves the use of neutral detergent diluted with water to the recommended levels. On a weekly basis, maintenance is also undertaken via a mechanical scrubbing machine. Polysafe Ultima does not require any special maintenance regime, although a dedicated cleaning procedure needs to be in place. For further cleaning guidance and recommended maintenance products, contact Polyflor s Customer Technical Services Team on 0161 767 1912. Alternatively, maintenance sheets are available directly from the Polyflor website on: www.polyflor.com. The Ultimate Solution We selected the flooring based on HSE recommendations and are extremely pleased with its performance. Brian Porter, Estates Manager, Wrightington Hospital.

Summary As has been shown at Wrightington Hospital, Polysafe Ultima is the complete flooring solution. For areas where the outcome of a risk assessment demands a floorcovering that can cope with exacting conditions and frequent, high viscosity contaminants, Ultima is the answer to retain underfoot safety and lower slip potential. Ideally placed as a tough performer within the safety flooring market, Ultima s sustainable slip resistant surface gives extra durability for years of performance and a complete piece of mind specification. The Colours Iron Ore 4340 w/r 4640 Mortar 4360 w/r 4600 Why Ultima? Sustainable slip resistance 40 RRL Pendulum wet test (Four S rubber /Slider 96) assured throughout the guaranteed life of the product Surface roughness typical result of over Rz 70µm to deal with oil and grease spillages Simple maintenance Bluestone 4390 w/r 4910 Pearl Granite 4330 w/r 4670 Flexible for ease of installation, coving and welding can be seam-welded to achieve an impervious and hygienic finish 10 year assurance of product performance, independently assessed by the British Board of Agrément Aurora Grey 4290 w/r 4610 Baltic Green 4350 w/r 4350 w/r = weld rod Useful references for further reading Assessing the slip resistance of flooring HSE Information Sheet, 2007 Taking Slips and Trips Seriously Paul Beaumont, HSC Slips and trips: The importance of floor cleaning HSE Information Sheet Slips and Trips 2 Slips and trips: Summary guidance for the catering industry HSE Information Sheet Catering Sheet No 6 Preventing slips in the food and drink industries technical update on floor specifications HSE Information Sheet Food Sheet No 22 Preventing slips and trips in kitchens and food service HSE Information Sheet Catering Sheet No 6 (revised) Preventing slip and trip incidents in the education sector HSE Information Sheet Education Sheet No 2 (revised) Slips and trips in the health services HSE Information Sheet Health Services Sheet No 2 UK Slip Resistance Group (UKSRG) Guidelines, 2005 Health Technical Memorandum 61 : Flooring Department of Health All HSE Guidance is available on: www.hse.gov.uk/slips/information.htm

CASE STUDY Technical Specification The table below details the technical properties of Polysafe Ultima. Gauge 2.5 mm Roll Size 2m x 20m = 40m 2 Product Weight 3000g/m 2 General Performance EN 13845 ASTM F1303 Agrément G5ws Use Area Classification 23, 34, 43 Reaction to Fire EN 13501-1 Class Bfl-S1 EN ISO 9239-1 8kw/m 2 EN ISO 11925-2 Pass ASTM E648 Class 1 05 Enhanced Slip Sustainable wet slip resistance* EN 13845 ESf RRL Pendulum Test 40 (wet test - 4S Rubber/Slider 96) Surface roughness Rz 70µm (Typical result) AS/NZS 4586 R11 The slip resistance is assured throughout the guaranteed life of the product, with strict adherence to HSE Guidelines Abrasion Resistance EN 13845 50,000 cycles EN 649 Group T VOC Emissions AgBB VOC test: Pass (Low result) Agrément Assurance Polysafe Ultima has been independently assessed by the British Board of Agrément and product performance is assured for at least 10 years in recommended use areas. With proper maintenance, the appearance, colour and slip resistance will be retained during this period Resistance to Chemicals Polysafe Ultima has good resistance to dilute acids and alkalis. The Polyflor Technical Information Manual provides a general guide. Chemical resistance charts by shade are available on request Hygiene Contains antimicrobial agents. This product has been independently tested and results demonstrate that it inhibits the growth of MRSA on the flooring. An effective cleaning regime is however, the most important defence against infection Electrical Behaviour EN 1815 This product does not accumulate static charges above 2kV and is classified as antistatic. For specialist applications where there is a requirement to dissipate the electrostatic charge, see the Polyflor ESD product ranges Customer Support For information regarding handling and installation, adhesives, maintenance, applications and chemical resistance, consult Polyflor Customer Technical Services on +44 (0)161 767 1912 or e-mail tech@polyflor.com. *For clarification regarding slip resistance, consult Polyflor Customer Technical Services.

FalckDesign AB PO Box 10251, SE-434 23 Kungsbacka, Energigatan 9, Sweden Tel: +46 (0) 300 15820 E-mail: info@falckdesign.com James Halstead Flooring New Zealand Ltd PO Box 98943 SAMC, 11 Dalgety Drive, Wiri, Auckland, New Zealand 2104 Tel: 0800 425 783 E-mail: sales@halstead.co.nz objectflor Art und Design Belags GmbH Wankelstraße 50, 50996 Köln, Germany Tel: +49 (0) 2236 966 330 E-mail: info@objectflor.de Polyflor Australia Pty Ltd 59-65 Wedgewood Road, Hallam, Vic 3803, Australia Tel: 1800 777 425 E-mail: sales@polyflor.com.au Polyflor Canada 500 College Avenue West, Guelph, Ontario N1G 1T5, Canada Tel: +1 519 763 3088 E-mail: acrawford@polyflor.ca Polyflor Ireland Unit 106, Millennium Trade Park, Ballycoolin, Blanchardstown, Dublin 15 Tel: +353 (1) 864 9304 E-mail: tmockler@polyflor.com Polyflor Middle East Level 14, Musallah Towers, Bur Dubai, PO Box 71862, Dubai, UAE Tel: +971 4 397 2485 E-mail: espm@eim.ae Polyflor Nordic Kjelsåsveien 168 B, N-0884 Oslo, Norway Tel: +47 23 00 84 00 E-mail: firmapost@polyflor.no Polyflor Polska Ul Gronowa 22/506, Poznan 61-680, Poland Tel: +48 61 820 3155 E-mail: polyflor@polyflor.com.pl Poly Sales Africa (Pty.) Ltd PO Box 3967, Edenvale 1610, South Africa Tel: (27) 011 609-3500 E-mail: info@polyflor.co.za Polyflor Contract Ltd Office 12, Business centre "Strela", d. 113, liter B, Ligovskiy pr., St.Petersburg, Russia. Tel: +7 812 333 06 33 E-mail: sales@polyflor.ru Polyflor Hong Kong Room 2409, 24th Floor, New York Life Tower, Windsor House, 311 Gloucester Road, Causeway Bay, Hong Kong Tel: +852 2865 0101 E-mail: anthonylam@polyflorhk.com For details on distribution for other countries, as well as up to date product and technical information, please visit WWW.POLYFLOR.COM POLYFLOR LTD. PO BOX 3 RADCLIFFE NEW ROAD WHITEFIELD MANCHESTER M45 7NR UK TEL: +44 (0)161 767 1111 UK SALES DIRECT: +44 (0)161 767 1122 UK SAMPLE REQUESTS: +44 (0)161 767 2551 EXPORT SALES DIRECT: +44 (0) 161 767 1913 TECHNICAL SUPPORT: +44 (0) 161 767 1912 UK FAX: +44 (0)161 767 1128 EXPORT FAX: +44 (0)161 767 1166 E-MAIL: INFO@POLYFLOR.COM WEBSITE: WWW.POLYFLOR.COM LIT165/JULY 08